Loading...
HomeMy WebLinkAboutAPPROVED, PlansCool and Cobb Engineering Company __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ 203 W. Main St. Avon Park, FL 33825 Office: (863) 657-2323 Fax: (863) 657-2324 Contractor: Alpha Foundations Date: 4/5/2021 Job: Caroline Sundin Location: 8102 Kenwood Rd. Fort Pierce, FL 34951 PILING DESIGN ANALYSIS The load requirements for the pilings designed to assist in supporting the identified areas of the subject residence were determined. The selected piling locations and the specific piling are identified on the Pier Identification and Location Plan attached. The calculated total loads on the piles in the specific loc ation, including both dead and live loads are documented in the attached table which is designated as Attachment “A”. Based on the total load requirements for each of these piles, the X9K5 driver is to be employed. The X9K5 torque driver should be employed with a selected gauge pressure of _1,000_ psi, which will provide pile capacity, including the 2 to 1 safety factor, of _29,000___ lbs. which is greater than the maximum calculated total load of _10,500___ lbs. which occurs on the pile identified as no. _1__. Based on this analysis, the use of the X9K5 torque driver for the piles with a specific gauge pressure of _1,000___ psi and a minimum depth of 10’ is approved and certified as meeting all of the requirements of the Florida Building Code 20 20 7th Edition, and good engineering practice. This is not to be the primary support structure, but a supplement support to assist in support of the weight of the structure, which will reduce the total pressure on the existing soils. After completion of installation, Cool and Cobb Engineering Company shall be supplied with a drilling log of the location and depths of each pile installed so they can evaluate the installation and prepare the “As Built” drawings. General Notes: 1.All piles to be installed in accordance with ICC ES AC 358 2.A log of each pile to be kept by Contractor n oting depth and final torque installed for each pile. 3.Minimum pile depth to be 10’-0” 4.All pile calculations are based on a maximum spacing of 7’-0”. 5.Helical piles installed less than 48” apart are to be battered 10° away from each other. 6.This design is based on the loads of the structure placed on the shallow soils under the structure. 7.No deep soils geotechnical testing information was provided for this design. 8.This design does not address any possible sink hole activity as defined in Florida Statute § 627.706. 4/5/2021 Carl Cool P.E. State of Florida Professional Engineer No. 16921 Job Details Alpha Foundation Specialists, Inc. 66 Industrial Park Monticello FL 32344 Job Location 8102 Kenwood Rd Fort Pierce FL 34951-1300 Page 2/7 3-25-213-25-21 Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825 Carl E. Cool, P.E. PE# 16921 4/5/2021 1 5 6 3 7 8 2 4 Date: Job: Location: PILE NO. 1 10,500 lbs 2 10,500 lbs 3 10,500 lbs 4 10,500 lbs 5 10,500 lbs 6 10,500 lbs 7 10,500 lbs 8 10,500 lbs 10,500 lbs Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825Carl E. Cool, P.E. PE# 16921 Cool and Cobb Engineering Company Maximum Total Load on Pile: 4/5/2021 4/5/2021 Caroline Sundin 8102 Kenwood Rd. Fort Pierce, FL 34951 Attachment "A" Total Load on Pile (Live Load + Dead Load) TOTAL CALCULATE LOAD X9K5 Torque Chart (Tons) 1 3 2 Differential Torque in ft-lb Ultimate Safety Factor of 3 Safety Factor of 2 Flow Rate RPM's Pressure PSI Tons Tons Tons GPM 800 PSI 2575 9.3 3.1 4.6 20 GPM 14.9 RPM 900 PSI 2898 10.4 3.5 5.2 22 GPM 16.4 RPM 1000 PSI 3221 14.5 4.8 7.2 25 GPM 18.7 RPM 1100 PSI 3543 15.9 5.3 8.0 1200 PSI 3865 17.4 5.8 8.7 1300 PSI 4187 18.8 6.3 9.4 1400 PSI 4509 20.3 6.8 10.1 1500 PSI 4832 21.7 7.2 10.9 1600 PSI 5154 23.2 7.7 11.6 1700 PSI 5476 24.6 8.2 12.3 1800 PSI 5798 26.1 8.7 13.0 1900 PSI 6120 27.5 9.2 13.8 2000 PSI 6442 29.0 9.7 14.5 2100 PSI 6764 30.4 10.1 15.2 2200 PSI 7086 31.9 10.6 15.9 2300 PSI 7408 33.3 11.1 16.7 2400 PSI 7730 34.8 11.6 17.4 2500 PSI 8053 36.2 12.1 18.1 2600 PSI 8375 37.7 12.6 18.8 2700 PSI 8697 39.1 13.0 19.6 2800 PSI 9019 40.6 13.5 20.3 2900 PSI 9341 42.0 14.0 21.0 3000 PSI 9663 43.5 14.5 21.7 Motor Mount: SAE "CC" 4 Bolt K=9 Motors: 315.0cc Bi-Directional Speed Max. System Pressure: 3,000 PSI Max. Torque:287 Output Shaft: 2-1/2" Hex Shaft 288 Design Tons Safety Factor Pounds Torque Factor Torque in ft-lb. 7.5 2 15 30000 9 3333.333333 Torque in ft-lb. Torque Factor Pounds Safety Factor Design Tons 4081 9 36729 18.3645 1 18.3645 K=10 K=8 K=7K=9 Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825 Carl E. Cool, P.E. PE# 16921 4/5/2021 EXISTING STRUCTURE CAP PLATE (FS288C) BRACKET (FS288BL2) BRACKET HARDWARE SEE NOTES TEMPORARY EXCAVATION 30" EXTERNAL SLEEVE (FS288ES30) HP288 OR HP287 PIER SHAFT COUPLER VERTICAL2.0° BRACKET DETAIL PROJECT DETAIL 11850 Valley Ridge Drive, Papillion, NE 68046 Phone: 800-281-8545 Document #:All dimensions are in inches and are for reference only. Ó SUPPORTWORKS Ò, INC. AR-HPBR-288-BL2 Assembly - Ø2-7/8" Helical Pier Bracket - Low Profile 2 01/06/20 1 1 1:10 NOTES: 1. MINIMUM MATERIAL REQUIREMENTS: BRACKET WELDMENT - ASTM A572 GRADE 50 EXTERNAL SLEEVE - Fy = 50 ksi, Fu = 62 ksi CAP PLATE - ASTM A572 GRADE 65 BRACKET HARDWARE - (2) - Ø 3 4" x 16" LONG GRADE B7 - Fu = 125 ksi ALL-THREAD ROD WITH NUTS (HWTR-S210-Z-075-16 & HWH8N-Z-075) OPTIONAL BRACKET HARDWARE - (2) - Ø3 4" x 16" LONG AISI 1045 - Fu = 120 ksi CONTOUR (COIL) THREAD ROD WITH NUTS (HWCR-S250-Z-075-16 & HWCN-Z-075) 2. ALL WELDING TO BE IN ACCORDANCE WITH AWS D1.1 LATEST ISSUE WITH E70-XX MIN ELECTRODE. 3. BRACKETS, CAPS, AND SLEEVES ARE AVAILABLE AS EITHER PLAIN STEEL OR HOT-DIP GALVANIZED IN ACCORDANCE WITH ASTM A123. A "-G" IS ADDED TO THE END OF THE PART NUMBER TO DESIGNATE PART AS HOT-DIP GALVANIZED. 4. BRACKET HARDWARE IS PROVIDED AS ELECTROZINC PLATED IN ACCORDANCE WITH ASTM B633. 5. THIS DOCUMENT IS MEANT TO SERVE AS A GENERAL DESCRIPTION FOR THE PRODUCTS SHOWN FOR SUBMITTAL PURPOSES. MORE DETAILED MANUFACTURING DRAWINGS ARE AVAILABLE UPON REQUEST. 6.75 14.00 6.007.254.00LIFT8.18Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825 Carl E. Cool, P.E. PE# 16921 4/5/2021