Plans Examiner Review Form
Contractor Florida Breeze Mechanical License # CAC1814113 Building Plan # 1916'CALI.3.5 TON Home Address (Street or Lot#, Block, Subdivision) Winter Design Conditions Outdoor temperature 42 OF Indoor temperature 70 OF Total heat loss 33384 Btu/h Summer Design Conditions Outdoor temperature 90 OF Indoor temperature 75 OF Grains difference 61 A Gr @ 50 % Rh Sensible heat gain 28259 Btu/h Latent heat gain 74.87 Btu/h Total heat gain 35747 Btu/h Heating Equigment Data Equipment.type Heat pump Furnace, Heal.pump, Boiler, etc, Model R4H442(A,G)'KP** Heating output capacity 41000 Btu/h Heal pumps -capacity at winter design outdoor conditions Auxiliary heat output capacity Btu/h Design airflow 1022 CFM External Static Pressure (ESP) 0.33 IWC Component Pressuie Losses (CPL) 0,25 IWC Available Static Pressure (ASP) 0.079 IWC ASP = ESP - CPL Contractor's Printed Name Kristin Kelly Contractors Signature rA14Z] Form RPER 1.01 8 Mar I.0 Header Irifomiation REQUIRED ATTACHMENTS' ATTACHED Manual Jt Farm: (and supporting worksheets):. Yes, No.� or MJ]AE Form= (and supporting worksheets): Yet No X OEM performance data (heating; cooling, blower): Yes I@ No Q Manual D Friction Rate Worksheet: Yes O No.© Duct distribution system sketch; Yes Q No'0 .11%A f l a awl lst.f ucnun inrormanon Building Orientation (Front d or-fia cos North North, East, West, South, Northeast, Northwest, Southeast, Southwest Number of bedrooms 4 Conditioned. floor area 1.916 Sq Ft Number of occupants 5 Windows Eave overhang depth Ft Roof 1 Internal shade F— Blinds, drapes, etc Eave Depth Window, Number of skylights 0 Equipment type Heat pump Air Conditioner, Heat pump, etc Model R4H442(A,G)KP** Sensible cooling capacity 30573 Btu/h Latent cooling capacity 8062 Btu/h Total cooling capacity 38636 Btu/h Longest supply duct: 10 Ft Longest return duct Ft Total Effective Length (TEL)14 Ft Friction Rate: I 1 0.56 lWC Friction Rate = (ASP ■ 100)+TEL Heating CFM 1352 1 CFM Cooling CFM_j3Z2A CFM Duct Materials *Used (circle) Trunk Duct: Duct board •Flex, Sheet metal, Lined sheet metal, Other (specify) Branch Duct uct board -lex Sheet metal, Lined sheet metal, Other (specify) Date 1 2/2.9/2020 : If abridged version of M--- - -- -.• • •� +�••�� nyaunnen�s pnnfec from approved ACOA software vendors, see list on p6ge'2 of instrudlons. - anual J is used for load `calculation, then verify'residence meets -requirements, see AbridgedEdition Checklist an page' 13 of instruct Form generated byACCA-approved Manual J Eighth Edition Verslori 2 Elite Software Rhvac program. Air Conditioning Contractors of America Manual S (Redidendai Equipment Selection) Project Information Name: • City: State: Altitude: Altitude Altitude Adjustment 1.00 .:uuung uesign mformation Outdoor Design. Temp:F 91 OF db Outdoorbestgn Temp: F437 OF db lndoor;Design Temp: =OF db Manual J Load Calculations Total Load Sensible Latent SHR Heat Loss 35747 28259E 7488 .0:791 Summer (Winter 50 I %RH 63 OF wb Airflow Calculations Design TD for Airflow 19 Design Sensible CFM 1352 OEM Information Manufacturer: COMFORTMAKER Furnace Model #: AFUE:� Coil or Fan -Coil Model #: FXM4X42'•AL Condenser Model#: R4H442(A,G)KP*' SEER: 14.0 HSPF: 8.20 (A) Manufacturer's Cooling Performance Data Entering Coil Temperature = 75 (F db) Lower Return Air CFM (F wb) Outdoor Total BTUH Temperature = Sensible BTUH 95 (F db) Latent BTUH SHR Rated CFM @ Rated RA Temperature 65 38;209 27,270. 10,939 0.7137 Rated CFM @ Design RA Temperature 1225 63 37,711 2ti,842 8;869 0.7648 Rated CFM @ Rated RA Temperature E 36,963 31,200 5,763 0.8441 toj tnanuracturers uoogng rerrormance Data Higher Return Air Entering Coil Temperature = 75 (F db) CFM (F wb) Outdoor Temperature = Total BTUH Sensible BTUH 95 (F db) Latent BTUH SHR Rated CFM @ Rated RA Temperature 65 41,344 29,628 11,716 0.7166 Rated CFM @ Design RA Temperature 1575 63 .40,258 32,028 8,230 0.7956 Rated CFM @ Rated RA Temperature 60 38,628 35,628 3,000 0.9223 rvtanutat.-turerS..00ung venormance Data (Interpolated) Design Return Air Outdoor Temperature = 95 (F db) CFM (F wb) Total BTUH . Sensible BTUH Latent BTUH SHR 29,999 8;637 0.7765 Excess Latent Capacity Calculation +1 574 Capacity @ Design CFM / RA (F wb) 1352.1 63 38,636 30,573. 8,062 F5.7911 Equipment Capacity as a % of Design F 168.68% 108.19% 107.67% Manufacturers Heat Pump Data Capacity Capacity Balance Supplemental @ 47 OF db @ 17 OF db Point. Heat Required 41,790 24,580 -25.8 -1587 Manufacturer's Furnace Data Input Output Desired Calculated