Loading...
HomeMy WebLinkAboutEngineering James Philip Drago, Registered Architect 333 NE 24 h St,Boca Raton,Florida 33431.........Seal#AR009780 (561)361-7161 office (954)275-8834 cell (561) 361-8096 fax "WINDOW / DOOR REPLACEMENT LETTER" Date: April 13, 2021 Project: Huff Door/Window Replacement Address: 10044 S Ocean Drive, #208,Jensen Beach,FL 34957 ------------------------------------------------------------------------------------------------- Dear: St Lucie County Building Official(s), I (James Drago, Registered Architect) have conducted a review of the proposed design pressures (PSF)for the above Commercial Property location to replace the doors and windows shown on the attached Floor Plan. Below 30'component height are as follows: (See attached Floor Plan for specific door and window size and design pressures) • ZONE 4 --46.7/-61..-1 • ZONE S --46.7/ -112.4 • Zone 5 is defined as 5.8'of building wall from building corners. Zone 4 is defined as all other wall space. Design pressures calculated with • II occupancy category • 16o mph ultimate design wind speed • D asce exposure category • 1 wind directionally factor (Kd) • 1 . topographical factor(Kzt) • 58'_min. (least)building dimension • 1or1' mean roof height, mrh • _ 9 9 elevation of installation • Flat (<10 deg) roof slope Therefore,please accept this letter as a formal certification that to the best of my belief and professional judgment that the proposed design pressures (PSF)to replace the doors and windows installation will meet (or exceed)the minimum requirements set forth by the 202o Florida Building Code—Building, 7th Edition. Thank you in advance for your assistance in this matter. James Drago, C Digitally signed by James �Drago,Architect AR00097 0 Architect Date:,2021.04.2712:2124.,- A aJ� '` ARCHITECT SEAL• R0009780 4 -04 00' James Philip Drago, Registered Architect AR#009780 MAY" 2021 1 r�r 0.„ WNDW 6-37"x 51" _ (46.7/-61.3) FROMPM . _ �_. WNDW S-37"x 51 = (46.7<-61.3) WNDW 1 -37"x 51" _ (46.7/-61.3) SGD 4- 72"x 80" _ (44.1/-59.0) SGD 1 - 72"x 80 = 44.1 /-59.0 ( ) 1 4; SGD 3 -107"x 80" _ (42.6/-57.7) M M M PO II Il II c 00 M M7 CM N N M HUFF DOOR/WINDOW REPLACEMENT 10044 S. OCEAN DRIVE#208,JENSEN BEACH,FL 34957 SPECIFIC DESIGN PRESSURES FOR LISTED UNITS IN ZONE 4 _ y t+-u L 1E1 �fPS MMAWRTY im' 'J' WINDOWS DOORS Window/Door Schedule New Appkox Opening Roam/Designation Impact Shutte Existing Remar Id# Size (WXH) Window Location Type Mass r Shunter ks 1 3-+ X S7 $a�.dr'+Dart V, ( Q,I+ 2 X 6 0 I#'z 5406 3 x S'I 4 � -x �c-( {Wi A RW 5 �-x s t t..iu 4.4. 'S 4 B B fl Iv p2a M gyp,(r�►�1 Itz 9 '4-K 5~ Qxac M w3 sil 11 12 13 14 IS 15 1 17 ss 19 20 21 22 f z,3 4 . 24 25 —_.