HomeMy WebLinkAboutProduct Approval (4) MIAMI•DADE NHAMI-DARE COUNTY � et �C� �49fi� RODUCT CONTROL SECTION f �e �, F t� U SO 4 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATIDEPARTMENT OF REGULATORY ON DIVISION IC RESOURCES'(REA�R) y / �I T,(786 3 15--2 9 Florida F 86)315 2599 L U C E� C O U ll�l 7 1f www.miamidade.Lov/buildin� NOTICE OF ACCEPTANCE (NOA) E.S.Windows,LLC L�U , 3550 NW 49`b Street Miami,FL 33142 SCOPE: ILpy This NOA is being issued under the applicable rules and regulations govern�t e `bf construction materials. The documentation submitted has been reviewed and accepted by Miami Dade County RER—Product Control Section to be used in Miami—Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Section (In Miami Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested-for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction.RER reserves the right to revoke this acceptance if it is determined by Miami—Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series"EL-150"Aluminum Fixed Windows—L.M.I. APPROVAL DOCUMENT: Drawing No.W16-70,titled"ES-EL150 Fixed Aluminum Wdw. (L.M.1)", sheets 1, 2,2.1, 3, 3.1, 4 and 5 through 9 of 9, dated 11/13/16,with revision C dated 06-22-20,prepared by Al-Farooq Corporation, signed and sealed by Jalal Farooq,P.E.,bearing the Miami Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami Dade County Product Control Section. NIISSILE IMPACT RATING:Large and Small Missile Impact Resistant. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, Barranquilla, Colombia, model/series, and following statement: "Miami Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.17-1218.12 and consists of this page 1 and evidence pages E-1,E-2,E-3 and E-4, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. NOA No.20-1223.01 MIAMI•DADE COUNTY Expiration Date: May 18,2022 Approval Date: April 22,2021 r4/15/21 Page 1 E.S.Windows,LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 16-0617.05) 2. Drawing No.W16-70,titled"ES-EL150 Fixed Aluminum Wdw. (L.M.1)", sheets 1 through 9 of 9, dated 11/13/16,with revision B dated 12/07/17,prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad,P.E. (Submitted under NOA No. 17-1218.12) B. TESTS 1. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC, TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 along with marked-up drawings and installation diagram of aluminum fixed window, prepared by Blackwater Testing, Inc., Test Report No. BT-ESW-16-004, dated 11/14/16, and revised on 05/10/17, signed and sealed by Constantin Bortes,P.E. (Submitted under NOA No. 16-0617.05) 2. Test reports on: 1)Large Missile Impact Test per FBC,TAS 201-94 2)Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of aluminum fined window, prepared by Blackwater Testing, Inc., Test Report No. BT-ESW-17-012, dated 05/10/17, signed and sealed by Constantin Bortes,P.E. (Submitted under NOA No. 16-0617.05) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 51b Edition (2014),dated 11/16/16 and revised on 12/21/16,prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad,P.E. (Submitted under NOA No. 16-0617.05) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). 1VIanuel Perez, Product Control Ex r NOA No.20- 23.0 Expiration Date: May 18, 2 Approval Date: April 22,2021 E-1 n1 E.S.Windows,LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's(CONTINUED) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America,Inc.for their "Trosifol®Ultraclear,Clear,and Color PVB Glass-Interlayer"dated 01/19/17, expiring on 07/08/19. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America,Inc.for their "SentryGlas®(Clear and White) Glass Interlayers"dated 06/25/15, expiring on 07/04/18. 3. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company(MA) for their"Saflex CP-Saflex and Saflex HP Composite Glass Interlayers with PET Core"dated 06/19/14, expiring on 11/11/18. 4. Notice of Acceptance No. 14-0423.16 issued to Eastman Chemical Company(MA) for their"Saflex HP Clear or Color Glass Interlayers"dated 06/19/14, expiring on 04/14/18. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 6t1 Edition (2017), and of no financial interest, dated 11/08/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad,P.E. G. OTHERS 1. Notice of Acceptance No. 16-0617.05,issued to ES Windows,LLC,for their Series "EL-150"Aluminum Fixed Window-L.M.I., approved on 05/18/17 and expiring on 05/18/22. Manuel Per6P .Product Control ExNOA No.20-Expiration Date: May 1 Approval Date: April 22,2021 E-2 -J E:S.Windows,LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No.W16-70,titled"ES-EL150 Fixed Aluminum Wdw. (L.M.I)", sheets 1,2, 2.1,3, 3.1,4 and 5 through 9 of 9, dated 11/13/16,with revision C dated 06/22/20, prepared by Al-Farooq Corporation, signed and sealed by Jalal Farooq,P.E. B. TESTS 1. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6) Safety Performance Test;(class A)per ANSI Z97.1 along with marked-up drawings and installation diagram of a series EL-150 aluminum fixed window,prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-12002,dated 04/30/20, signed and sealed by Idalmis Ortega,P.E.. 2. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6) Safety Performance Test, (class A)per ANSI Z97.1 along with marked-up drawings and installation diagram of a series EL-150 aluminum fixed window,prepared by Fenestration Testing Laboratory, Inc.,Test Report No. FTL-11035, dated 04/30/20, signed and sealed by Idalmis Ortega,P.E. 3. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6) Safety Performance Test, (class A)per ANSI Z97.1 along with marked-up drawings and installation diagram of a series EL-150 aluminum fixed window,prepared by Fenestration Testing Laboratory, Inc.,Test Report No. FTL-11027, dated 04/23/20, signed and sealed by Idalmis Ortega,P.E. Manuel Perez,P.E: Product Control Exa r NOA No.20-1 23.0 Expiration Date: May 18, 2 Approval Date: April 22,2021 E-3 E.S.Windows,LLC . NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED (CONTINUED) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 51 Edition (2014), dated 11/16/16,revised on 12/21/16, and updated on 11/09/20 to comply with FBC 71h Edition(2020),prepared by Al-Farooq Corporation, signed and sealed by Jalal Farooq,P.E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 19-0305.02 issued to Kuraray America,Inc.for their "Trosifol®Ultraclear,Clear and Color PVB Glass Interlayers"dated 05/09/19, expiring on 07/08/24. 2. Notice of Acceptance No. 18-0725.11 issued to Kuraray America,Inc.for their "Kuraray SentryGlas®XtraTm(SGXTM)Clear Glass Interlayer"dated 05/23/19, expiring on 05/23/24. 3. Notice of Acceptance No. 20-0622.03 issued to Eastman Chemical Company(MA) for their"Saflex Storm-Saflez and Saflex HP Composite Glass Interlayers with PET Core"dated 08/06/20,expiring on 12/11/23. 4. Notice of Acceptance No.20-0622.02 issued to Eastman Chemical Company(AIA) for their"Saflez HP Clear or Color Glass Interlayers"dated 08/06/20, expiring on 04/14/23. F. STATEMENTS 1. Statement letter of conformance,complying with FBC 6th Edition (2017),with FBC 7th Edition(2020),and of no financial interest,dated November 09,2020,issued by Al- Farooq Corporation,signed and sealed by Jalal Farooq,P.E. 2. Proposal No. 18-0784 issued by the Product Control Section, dated June 29, 2018, signed by Manuel Perez,P.E. 3. Proposal No. 19-1230 issued by the Product Control Section,dated November 18, 2019, signed by Manuel Perez,P.E. G. OTHERS 1. Notice of Acceptance No. 17-1218.12, issued to ES Windows,LLC,for their Series "EL-150"Aluminum Single Fixed Window—L.M.I., approved on 02/08/18 and expiring on 05/18/22. Manuel Perez,P.E:: Product Control Ex n r NOA No.20- 23.0 Expiration Date: May 18,' 2 Approval Date: April 22,2021 E-4 a � 60" l� WINDOW WIDTH WINDOW WIDTH 9� r I ' to 7 8' 48" 56 7/8" 56 / WINDOW WIDTH ^m D.L.OPG. D.L. OPG. O H m 12" 12" 44 7/8" 6" MAX. MAX. 6"MAX.EA MAX, HEAD/SILL A HEAD HD/SILL A HEAD D.L.OPG.72e fY a .�.^ CORNERS 4 SILL CORNERS 6 SILL O g o I MAX HEAD/SILL 7 SIIALLD "Ids CORNERS I C Mo V zi I; II ;I I; II ;1 p• 01 0 5 it ii li s it ii li ____ Q 2 a K o c� it ii 4 it �� C i it H �, tE OEM o I� II 4 0 ao 11 II II II d .+Z�M ME J = n 0 0 _ II 11__==11 o O o IIry 11 ^O d IIiy II m 3 n O Z II I II _ N Z I II 1n O N-4 II II II II 11 II '� I II 11 -a v I II I I 11 I II II _ jl II II 11 II II I! II II � � I I I II I II II II---JL---II --- r--- --�r--- M w J �W Q f5 FALSE MUNTINS B m B B w 3 (SURFACE APPLIED) 4 e i¢ 6 u v 4. `}'M m MAY BE USED TYPICAL ELEVATION TYPICAL ELEVATION TYPICAL ELEVATION In FLANGE FRAMES FLANGE FRAMES WITH FLUSH ADAPTER FLANGE FRAMES WITH FIN ADAPTER w U)0 R to WINDOWS WITH FIN FRAME ADAPTERS LIMITED TO w lyl M GLASS TYPES 'A'. 'Ai','B', 'DI' &'Ei' ONLY ES—EL150 DAYLITE OPENINGS FIXED ALUMINUM WINDOW D.L.O. HEIGHT WINDOW HEIGHT — 3.125" DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE D.L.O. WIDTH = WINDOW WIDTH — 3.125" r «'a CHARTS SHOWN ON SHEETS 3 AND 3.1. REQUIREMENTS OF THE 2017 (6TH EDITION)/2020 (7TH EDITION) FLORIDA B R Q BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE WINDOWS WITH GLASS TYPES AAA', 'BB' & 'AAi' 'COMPLY g g 01 COMBINATIONS OF FIX./FIX. OR FIXED WITH OTHER DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPUED PRODUCT LOADS WITH REQUIREMENTS OF ANSI Z97.1. WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USING TO THE BUILDING STRUCTURE. MIAMI—DADE COUNTY APPROVED MULLIONS IN BETWEEN. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE I THESE WINDOWS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. o RIM WILL APPLY TO ENTIRE SYSTEM. MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. !!SHUTTERS ARE NOT REQUIRED. o A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. PRODUCT REVISED t11111111�T c<m u ffi ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON-COMPRESSIBLE. BWldieg 1 Bewith the Florida ♦♦♦♦♦N //,���' MATERIALS INCLUDING BUT NOT UMITED TO STEEL/METAL SCREWS,THAT NOA-llo. d 20.1223.01 `♦♦��?;• pEN3F• !�' y •I o COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE fu Iretfon Date- 5/18/2022 REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE &ADOPTED STANDARDS. No.81223 THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY Mlem do Produe trol OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR yy q y WATER INFILTRATION RESISTANCE ETC. r'© 1 6 "D v ST OF� drawing no. CONDITIONS NOT'SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED'BY BUILDING OFFICIAL. �i�.`1•'•. ORIDP;.•'�,®� V1116-70 DESIGN LOADS SHOWN ARE BASED ON 'ALLOWABLE STRESS DESIGN (ASP)'. '/,4!�/�B®�fAib.��♦♦ / //Tryi 1i111♦ sheet 1 of 9 Al 1/8"HEAT STREN'D.GLASS 3/16" HEAT STREN'D. GLASS �V 0 r 090"Interloyer 090"Interlayer � l 7rosifol PV13 7rosifol PVB By OR Kuroroy America, Inc.' BByR'Kuromy America, Inc.' Z m m 3 q N J 090'Interlayer 090"Interlayer 0 q n Sent las SentryGlas I- i a OR Ku gray America, Inc.' BR'Kuraray Ameries, Inc.' 4. U 090'Interlayer 090 Interlayer t� Saflex Clear And Color Glass Saflex Clear And Color Glass a µIuI By 'Eastman Chemical Co: By'Eastman Chemical Co.' 0 p w OR OR 075"Interlayer 075"Interloyer N Saflex CP With PET Core Saflex CP With PET Core 0911 By 'Eastman Chemical Co.' By'Eastman Chemical Co.' C'R—a� o paaos 3/16"HEAT STREN'D.GLASS 0 0 m 1/4'HEAT STREN'D.GLASS In 0.N V1 z SILICONE 16" AIR SPACE CONSISTING OF: m SIUCONE OOWSIL 795 M2 DOWSIL 795 M2 j� I: DOWSIL 983IL I!I DOWSIL 983 cs II DOWSIL INSTANT GLAZE III _ SPAC�` z N n I! DOWSIL INSTANT GLAZE III I i! 'HEUMA' LOW PROFILE ALUMINUM SPACER J �S Ij) ii !i BY 'LINGERMANN GMBH' Q m :. AROUND THE PERIMETER OF THE GLASS. PERIMETER SEALANT: o o SILICONE m E7 w O DOWSIL 791 ° AT 1/4 POINTS ON LITES MD AT 1/4 POINTS ON LRES GE 2000 M3 WIDER THAN 36'ONLY }+ m WIDER THAN 36`ONLY 0 GLASS TYPE 'A' 3 GT.eSs TYPE 7/16"OVERALL LAM.GLASS 7/16"OVERALL LAM. GLASS Z U 1/8"TEMP.GLASS 1/4"TEMP.GLASS 5/32"TEMP. GLASS 5/16"AIR SPACE 5/16"AIR SPACE 5/16"AIR SPACE w N ur 1/8" HEAT STREN'O. GLASS 5/32"HEAT STREN'D. GLASS 1/8"HEAT STREN'D. CLASS F, a. 090'Interlayer 0 Z 3 iO 090"Interlayer 090"Interloyer 0 7rosifol PVB 7rosifol PVB 7rosifol PVB 3r Z N By Kuraray America, Inc.' w o By'Kuraray America, Inc.' By'Kuraray America, Inc.' OR 0 ."'. OR OR 090"Interloyer 090"Interlayer 090"Interloyer w W M SentryGlas SentryGlas By'KGlas BR'Kuraray America,Inc,' BBy IKuraroy America, Inc.' By Kuroroy America, Inc.' R I 090"Interloyer 090"Interloyer 090"Interlayer Saflex Clear And Color Glass Saflex Clear And Color Glass Saflex Clear And Color Glass By'Eastman Chemical Co.' By'Eastman Chemical Co.' By Eastman Chemical Co.' OR OR OR 075"Interlayer 075• Interlayer 075" Interlayer Saflex CP With PET Core Saflex CP With PET Core Saflex CP With PET Core c"� B Eastman Chemical Co.- B 'Eastman Chemical Co.' SILICONE By Eastman.Chemical Co.' c y' Y DOWSIL 791 PRODUCT REVISED 1/4"HS. GLASS 5/32'HEAT STREN'D. GLASS (1/8"x 1/16') 1/6"HS. GLASS as compTng with the Florida m Building odde SILICONE SILICONE NOBrNo. 20-1223.01 �3 DOWSIL 795 w DOWSIL 795 SILICONE Irotlon Date• 5/18/2022 DOWSIL 983 m -DOWSIL 983 DOWSIL 795 Q���� i m DOWSIL INSTANT GLAZE III i DOWSIL INSTANT GLAZE III z N By races c e M2 i a g M2B Mlam pads Produgt'Co trot ° I iI I q li � III ;i II t`11111 I11/l/// � �a m o I E4 E4 AT 1/4 POINTS AT 1/4 POINTS AT 1/4 POINTS M4 ALL SIZES M4.'ALL SIZES M4 ALL SIZES 0 1 202 •L. j $ v 5 DECCJ 1 L ti7 ® . ,STATE OF drawing no. GLASS TYPE 'Ai' GLASS TYPE 'Di' GLASS TYPE TV W�6-70 7/8'OVERALL iNSUL.LAM.GLASS 7/8"OVERALL INSUL. LAM. GLASS 7/8"OVERALL INSUL,LAM.GLASS // t�\�\` SheaL Q °f 9 GLAZING OPTIONS f' Jt �i 1/8' NEAT BTREN'D. GLASS 1/8"HEAT SIREN-D. GLASS 3/16"HEAT STREN'D.GLASS 3/16"HEAT STREN'D.GLASS 090'Interlayer 090"Interlayer 090"Interlayer .090"Interlayer h J. SentryGlas .SentryGlas SentryGlas SentryGlas p q' By Kuraray America, Inc.' By'Kuraray America, Inc.' By'Kuraray America, Inc.' _ By 'Kuraray America, Inc.' �' 2 04 1/4"HEAT STREN'D.GLASS 1/4"HEAT STREN'D. GLASS 3/16"HEAT STREMD.GLASS 3/16"HEAT STREN'D.GLASS O 0 G`0 0 F C m SILICONE 0.l" m SILICONE m SILICONE = m SILICONE z IWu ut DOWSIL 795 M?A DOWSIL 795 M2 ' DOWSIL 795 M2A DOWSIL 795 O C �. V gar N II, C a¢ 8 I. p a. p a: o oZ o E7 c E7A E7 E7A Z O— AT 1/4 POINTS ON UTES AT 1/4 POINTS ON LITES AT 1/4 POINTS ON UTES AT 1/4 POINTS ON UTES J 0 m_ LI M3 WIDER THAN 36'ONLY M3 WIDER THAN 36"ONLY M3 WIDER THAN 36"ONLY M3 WIDER THAN 36"ONLY Q OMif LA TYPE 'AA' GLASS TYPE 'BB' 7/16"OVERALL LAM.GLASS 7/16"OVERALL LAM.GLASS g m 3 I M 0 ,a 3 � o Z J �W Q 0 X O O)j7 n 1/8"TEMP. GLASS O Z 3_j m W.. 5/16"AIR SPACE Z m J c W 0_Mj 1/8"HEAT STREN'0. GLASS I fA Ln W LIIM .090"Interlayer SentryGlas SILICONE By'Kuraray America,Inc.' DOWSIL 791 (1/8'X 1/4") 1/4"HS.GLASS s SILICONE z m DOWSIL 795 _ g u N M28 II cs I I, f 5/16" AIR SPACE CONSISTING OF: ,y SPACER PRODUCT REVISED H° o HELIMA' LOW PROFILE ALUMINUM SPACER as,complying with the Florida o BY TINGERMANN GMBH' eullalzCode `t11LL1LLiAAAAA w E4A qT 1/4 POINTS AROUND THE PERIMETER OF THE GLASS. NOA-No. 20.1223.01 ``�����.• P� �� m S� Expiration Data• 5M 812022 �$�:'VCEN3�c'•, T o 0 M4 ALL SIZES PERIMETER SEALANT: SILICONE GLASS TYPE 'AAi' DOWSIL 791 13y: j 7/8"OVERALL INSUL.LAM.GLASS GE 2000 Miami do Produ troi Rb.Bi223 ear:= m DEC 0 1202" AV sr '" drawn v no. GLAZING OPTIONS r> DESIGN LOAD CAPACITY - PSF DESIGN LOAD CAPACITY -PSF WINDOW WINDOW FLANGE FRAMES, FLUSH FRAMES,:FIN FRAMES FLANGE FRAMES, FLUSH FRAMES, FIN FRAMES WIDTH WIDTH GLASS TYPE GIASS TYPES CUSS TYPE GLASS TYPES ; f- -� M WINDOW DIMS, 'A' 'B',W.'Di',TV � WINDOW DIMS. 'A' '11%'A1','Di',TV WIDTH HEIGHT EXT.(+) INT.(-) W.(+)" 1NL(-) WIDTH HEIGHT EM.(+) INT.(-) EXT.(+) INT.(-) Z n zd 30' 60.0 80.0 80.0 80.0 30' 60.0 80.0 80.0 80.0 I 36" 60.0 80.0 80.0 80.0 36" 102" 60.0 72.9 80.0 80.0 0 42" 48" 60.0 68.6 80.0 BO.0 42" 60.0 64.8 80.0 80.0 z I I 0 0 N V v 48' 60.0 60.0 80.0 80'0 30' 60.0 80.0 80.0 80.0 �uN 54' 60.0 60.0 80.0 80.0 36` 10B" 60.0 72.0 80.0 80.0 L J O 60` 60.0 60.0 80.0 80.0 42" 60.0 63.8 80.0 80.0 0 (19 30" 60.0 80.0 80.0 80.0 30' 60.0 80.0 80.0 80.0 C r 114' WINDO,�WIDTN WINDOW_WIDTH 0,O 0 m 36" 60.0 80.0 80.0 8 ..0 36' 60.0 71.3 80.0 80.0 II- _'ll 0 aC D o 42' 54" 80.0 68.6 60.0 80.0 30" 120" 60.0 80.0 80.6 80.0 0- - r'---- , 0 o b 9 48" 60.0 60.0 80.0 80.0 36" 60.0 70.6 80.0 Sam + Z 0 54' 53.3 53.3 71.1 71.1 12 N 60' 53.3 53.3 71.1 71.1 30" 60.0 80.0 80A 80.0 9 336• 60.0 80.0 80.0 80.0 DESIGN LOAD CAPACITY - PSF 42' 60" 60.0 68.6 80.0 80.0 FLANGE FRAMES, FLUSH FRAMES. FIN FRAMES 48' 60.0 60.0 80.0 80.0 GLM'TYPE GLASS TYPES WINDOW �----����� _� WINDOW WIDTH 1 1 WIND01 1 v n 54' 53.3 53.3 77.1 71.1 WINDOW DIMS.. 'A 'B','Ai','D!','EI' I � 60' 48.0 48.0 64.0 64.0 WIDTH HEIGHT EXT.(+) 1NT.(-) EXT.(+) 1NT.(-) 0 30' 60,0 80.0 80.0 80.0 19-1/8` 60.0 80.0 80.0 80.0 I I I 3 36' 60.0 80.0 80.0 80.0 26-1/2" 60.0 80.0 80.0 80.0 42' 66' 60.0 68.6_ 80.0 _ 80.0 37• 26" 60.0 80.0 80.0 80.0 Z U 48" 60,0 60.0 80.0 80.0 48" 60.0 80.0 80.0 80.0 ; 3 3 - ...I t LLI 54" 53.3 53.3 71.1 71.1 53-1/8" 60.0 00.0 80.0 80.0 Laf J < J 60" 1 48.0 48.0 64.0 64.0 19-1/8° 60.0 80.0 80.0 80.0 0 (6 t-n w 30' 60.0 80.0 80.0 80.0 26-1/2" 60.0 80.0 80.0 80.0 60.0 B0.0 80.0 80.0 37• 38-3/8" 60.0 77.8 80.0 B0.0 WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH x CI`l M m 42"36" ------ �{ z 42' 72• 60.0 68.6 80.0 00.0 48' 60.0 75.0 80.0 80.0 _ __ v�i Z 48" 60.0 60.0 80.0 80.0 53-1/8` 60.0 75.0 80.0 80.0 r (-- _ , j 54" 53.3 53.3 71.1 71.1 19-1/8" 60.0 80.0 80.0 80.0 i� �� i, 'Z %f to W 0 3 J 60° 48.0 48.0 84.0 64.0 26-1/2` 60.D 80.0 80.0 80,0 3 3 I 3 w M 30• 60.0 80.0 80.0. 80.0 37` 50-5/8" , 60.0 77.8 80.0 80.0 36' 60.0 - 78.0 80.0 80.0 48" 60.0 60.0 80.0 80.0 42" 78' 60.0 60.6 80.0 80.0 53-1/8" 56.9 56.9 75.9 75.9 ALLOWABLE LOADS FOR ALTERNATE SHAPES AS SHOWN ABOVE OR SIMILAR CAN BE 48' 60.0 60.0 80.0 80.0 19-1/8' 60.0 80.0 80.0 80.0 VERIFIED BY INSCRIBING PICTURE WINDOW SHAPE WITHIN SQUARE OR RECTANGLE AS $4' 53.3 53.3 71.1 71.1 26-1/2" 60.0 80.0 BOX 80.0 SHOWN IN DOTTED LINES AND OBTAINING ALLOWABLE LOADS FROM THOSE SHAPES. � 30" 60.0 B0.0 80.0 80.0 37" 58' 60.0 77.8 80.0 80.0 0 36' 60.0 76.4 80.0 80.0 48. 60.0 60.0 00.0 80.0 c 42" 84' 60.0 66.6 80,0 80.0 53-1/8` 54.2 54.2 72.3 72.3 0 33 48' 60.0 60.0 _ 80.0 80.0 19-1/8" 60.0 80.0 80.0 80.0 Ca 54' 53.3 53.3 71.1 71.1 26-1/2' 60.0 80.0 80.0 80.0 W NOTE; 30" 60.0 80.0 80.0 80.0 37" 63' 60.0 77.8 80.0 80.0 GLASS CAPACITIES ON THIS SHEET ARE y c d-^ 36' 90. 6010 75.0 80.D 80.0 48' 60.0 60.0 80.0 BO.O BASED ON ASTM E1300-09 (3 SEC. GUSTS). 0 o o q� 42' 60.0 67.1_ 80.0 80.0 53-1/8' 54.2 54.2 72.3 12.3 PRODUCT REVISE p `o -U 48• 60.0 60.0 80.0 80.0 19-1/8" - 60.0 80.0 86.0 80.0 L ea com bf:fg with the FloNda NAIIAIIIIpllll c< 30' 60.D 80.0 80.0 80.0 26-1/2` 60.0 BOX � 80.0 80.0 J f NOId��c 0 Z0-7ZZ3.01 `` .......... 36' 96. 60.0 73.8 80.0 80.0 37° 76' 60.0 77.2 80,0 80.0 / k:x iration Dake• H8/2022`� � AIOEN3 � .. ,l 42' 60.0 65.8 80.0 80.0 48" 60.0 60.0 80.0 80.0 48' 80.0 60.0 80.0 80.0 53-1/8 54.2 54.2 72.3 72.3 '� 'M, BY: N0.81223 Nkam ado Prod ln� y ral PJC U 9 323 :�1��•., SFA'fE ,r•,�� drarng�no. F ORIDp,:�a�,�, W16-70 WIDTH AND LENGTH DIMENSIONSqc�v�'•.......... VERTICALLY OR HORIZONTALLY ASOSHOWN ABOVE.O ''7 /'�®N��t ���� -sheet.3 Of fL 1 . j•. DESIGN LOAD CAPACITY - PSF DESIGN LOAD CAPACITY -PSF WINDOW WINDOW FLANGE FRAMES&FLUSH FRAMES ONLY FLANGE FRAMES &FLUSH FRAMES ONLY WIDTH d WIDTH GLASS TYPES GLASS TYPE GLASS TYPES GLASS TYPE OILJI WINDOW DIMS. 'AA'&'AM' 'BB' WINDOW DIMS. 'AA' 'AAI' 'BB' ZWIDTH HEIGHT EXT.(+) 1NT.(-) EXT.(+) TNT.(-). WIDTH HEIGHT EXT.(+) TNT.(-) EXT.(+) TNT.(-) Z080.0 105.0 80.0 100.0 1. - - 80.6 80.0 1-w54' 80.0 105.0 80.0 100.0 54" 102• - - 80.0 80.066' 48° 800 1050 80.0 100.0 48" - - 80.0 80.0 ' L72• 80.0 105.0 80.0 100.0 54" 108• - - 80.0 80.0 O 0 t7 u 78• 80.0 105.0 80.0 100.0 60" - - 80.0 80.0 V ui ti O'o 54" 71.1 105.0 3.3 80.0 88.9 48" 114' - - 80.0 80.0 WIND01 1 W WIDTH, WINDOW 1 0.¢Mtn o 54' 71.1 93.3 80.0 88.9 54' - - 80.0 80.0 0 a O c 601. S4, 71.1 93.3 60.0 88.9 48" 120" - - 80.0 80.0 O Y°�T y O 66' 71.1 93.3 80.0 88.9 54" - - 80.0 80.0 LL 72" - 80.0 88.9 „ zulz Q" 80.0 8809 48' 80.0 105.0 80.0 100.0 Bi N,� 54' 71.1 93.3 80.0 88.9 60' 64.0 84.0 86.0 80.0 66' 60° - - 80.0 80.0 WINDOW YN /IDTHd DESIGN LOAD CAPACITY - PSF WINDOW WIDTH WINDOW WIDTH I_ II 72• - - 80.0 80.0 FLANGE FRAMES& FLUSH FRAMES ONLY 78• - 80.0 80.0 GLASS TYPES GLASS TYPE �p n 48• 80.0 105.0 80.0 100.0 WINDOW DIMS. 'AA'&'AAi' 'BB' 54' 71.1 93.3 80.0 - 88.9 WIDTH HEIGHT EXT.(+) 1W.(-) EXT.(+) 1NT.(-) 60' - - 80.0 80.0 19-1/8" 80.0 105.0 80.0 100.0 I % I ;y I •� ? L) ,! 66. 66• - - 72.7 72.7 26-1/2` 80.0 105.0 80.0 100.0 3 •� 3 3 j ril a 72' - - 72.7 72.7 37" 26' 80.0 105.0 80.0 100.0 L J ¢ 78• - - 72.7 72.7 48• 80.0 105.0 80.0 100.0 W V)dN•In 48" 80.0 105.0 it 53-1/8" 80.0 105.0 80.0 100.0 x p 0)M 54. - - 19-1/8' 80.0 105.0 80.0 100.0 WINDOW WINDOW WINDOW WIDTH ia. O r•1 M 60• 72• - - 26-1/2• 8010 105.0 80.0 100.0 66' - - 37" JB-3/8' 80.0 105.0 80.0 100.0 r ,x r- -1 W o 72" - - 48" 80.0 105.0 80.0 100.0 i, z y, ;, ITI s78• - - 53-1/8' 80.0 105.0 80.0 100.0 � I M M 48" 80.0 105.0 19-1/8" 80.0 105.0 80.0 100.0 3 3 3 54• - - 80.0 88.9 26-1/2" 80.0 105.0 80.0 100.0 60. 78' - - 80.0 80.0 37" 50-5/8" 80.0 105.0 80.0 100.0 ALLOWABLE LOADS FOR ALTERNATE SHAPES AS SHOWN ABOVE OR SIMILAR CAN BE 66' - 72.7 72.7 48' 80.0 105.0 80.0 100.0 VERIFIED BY INSCRIBING PICTURE WINDOW SHAPE WITHIN SQUARE OR RECTANGLE AS 72• - - 68.7 66.7 53-1/8 75.9 99.6 80.0 943 SHOWN IN DOTTED LINES AND OBTAINING ALLOWABLE LOADS FROM THOSE SHAPES. 78" - - 61.5 61.5 19-1/8, 80.0 105.0 80.0 100.0 c 48' - - 80.0 100.0 26-1/2° 80.0 105.0 80.0 100.0 t r j 54' - - 80.0 86.9 37' 58' 60.0 105.0 80.0 100.0 60' 84' - - 80,0 80.0 - 48" 80.0 105.0 80.0 100.0 66• - - 72.7 72.7 53-1/8" 72.3 94.9 80.0 90.4 NOTE: 72• - - 667 66.7 19-1/8" 80.0 105.0 80.0 160.0 I" '""'I GLASS CAPACITIES ON THIS SHEET ARE b; 48' - - 80.0 100.0 26-1/2" 80.0 105.0 80.0 100.0 BASED ON ASTM E1300-09 (3 SEC. GUSTS). o o 54• - - 60.0 80.0 37" 63' 80.0 105.0 80.0 100.0 PRODUCT REVISED w _ as complying with the Florida 1111111111"60* °c " 66' 90' - 72.7 72.7 53 80.0 80.0 481/8' 72 3 94.9 80 0 90.4 L NOBuiIding A-Nome 20.1223.01 ���```Qr��"'�r'�''''i�if `O ' 72• - - 68.7 66.7 19-1/8' 80.0 105.0 80.0 100.0 �� Ex iration Date• 5/1812022 UIOENSF 48' - - 80.0 100.0 26-1/2' 80.0 105.0 80.0 100.0 / Sir - - 54° - - No. 23 1 80.0 80.0 37° 76" 80.0 105.0 B0.0 100.0 :; �(= 0 b 60° 96, - _80.0 80.0 48' 80.0 105.0 80.0 100.0 Mlam pads ProdueyyCCn�o Crory!l _ tiT. _ o E { 66' - 72J 72.7 53-1 8` - - 80.0 90.4 U`A�E[1�J '�S l/' / drawing9 rio. I �;g WIDTH AND LENGTH DIMENSIONS CAN BE ORIENTED VERTICALLY OR HORIZaNTALLY AS SHOWN ABOVE. �1/111IU1111 sheet 3.lof 9. 1BY TYPICAL ANCHORS w WOOD BUCK SEE ELEV. FOR SPACING x �F __ _ ___ 4 V METAL I 1 MWMI-DARE COUNTY APPROVED I I m EDGE DIS STRUCTURE j MULLION & MULLION ANCHORS I j 3 ° o I SEE SEPARATE APPROVAL II Z m 9 / EDGE OIST: I I e� II EDGE DIST, I 0 I a ------ ------ - E7 - I -- ---- ---- U ♦�0 �0 0 O M1 � 0ti'wy ! ' TYPICAL ANCHORS TYPICAL ANCHORS 1YPICAL ANCHORS 0 a G g ! I SEE ELEV. SEE ELEV. SEE ELEV. 0. j ! FOR SPACING FOR SPACING FOR SPACING 1%y y 0 - WOOD BUCKS AND METAL STRUCTURE NOT BY E.S. WINDOWS CO 0 U MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM Q w m k .ii AND TRANSFER THEM TO THE BUILDING STRUCTURE. i r 1 11 I i TYPICAL ANCHORS: SEE ELEV. FOR SPACING -I u00i 1/4" DIA, TAPCON BY 'IiW' (FU-125 KSI, Fy-100 KSI) 3 m 'I r 1/4" DIA, ULTRACON+ BY 'DEWA T' (Fu-164 KSI,Fy=145 KSI) 3, INTO 28Y WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN, PENETRATION INTO WOOD (HEAD/SILL/JAMBS) i THRU 1BY BUCKS INTO CONC. OR MASONRY w x R 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) ¢ o , 1-1/4" MIN. EMBED INTO MASONRY (JAMBS) RY x O z DIRECTLY INTO CONCRETE OR MASON O1 w O 1-1/2" MIN, EMBED INTO CONCRETE (HEAD/SILL/JAMBS) J n W 1-1/4" MIN. EMBED INTO MASONRY (JAMBS) 3 Z tz 1/4" DIA. TIEIr. OR CFI F nau I wr: SCREWS (GRADE 5 CRS) N ro INTO MIAMI-DADE COUNTY APPROVED MULLIONS w Ltj tr OR INTO METAL STRUCTURES (HEAD/SILL./JAMBS) (3) THREADS MIN. TO EXTEND BEYOND METAL THICKNESS ALUMINUM: 1/6" THK, MIN. (6063-T5 MIN.) ` STEEL: 1/8"THK. MIN. (Fy = 36 KSI MIN.) 3d (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) ^_ c ry � TYPICAL EDGE DISTANCE ° dui INTO CONCRETE AND MASONRY = 2" MIN. o 8 r•I � ' �'i INTO W000 STRUCTURE = 1" MIN. m �g I' INTO MEAL STRUCTURE = 3/4" MIN. O WOOD AT HEAD, SILL OR JAMBS SG = 0.55 MIN. E2 E2 CONCRETE AT HEAD, SILL OR JAMBS Vc = 3D00 PSI MIN, c C-90 HOLLOW/FILLED BLOCK AT JAMBS}'m m 2000 PSI MIN. o �H y � N PRODUCT REVISED 111111111r >t'cam o Mt au comp Ing with the Florida M1 E7 ,r d E7 ( Bulldtngoda e ° NOA-No. 20.1223.07 e° �� Ex (ration D.atv05/18/2022 • I :<° e.. , G✓ 6L..J7 _= N0, a Jam_ EDGE DIST. y ° \ .. .o•, 1BY Mlam pads Produce!-Co tral yt. "-� WOOD BUCK DEC 0STATE drawing=no. TYPICAL ANCHORS _ TYPICAL ANCHORS� FOR SPACING EDGE DIST. -SEE ELFV. �/�tS�i ������ W16—/-7 O FOR SPACING / 1�\\\\\ sheet"¢of g' w Z gk 1/4'MAX. © 1/4'MAX. C SHIM SHIMS 1/4"MAX, '•,s Q 6 S O TYPICAL ANCHORS SHIMS 7YPICAANCHORS 'Q AO N` o M1 E2 SEE ELEV. .Y,�'• FOR SPACING—SEE ELEV. W FOR SPACING aC D �° n 0.N enl 1 /2' d,1/4. _.1. cy G Y o0ILa g - _ 03 8 4p EXTERIOR )BY , g E1 I D.L.OPC. _ a WOOD BUCKS n c• J p 18Y v WINDOW WIDTH WOOD BUCKS - 3 TYPICAL ANCHORS SEE ELEV. 7 3 FOR SPACING Z U 1/4"MAX MIAMI-OADE COUNTY Q N APPROVED MUWON SHIM w � SEE SEPARATE APPROVAL x OOP N ---i TYPICAL ANCHORS v�j 3SEE ELEV. z I j j l FOR SPACING W 0=,n1 II II W WM� II II 80 Ij w II �.n I`-- 'I - - - -- C�u METAL i TYPICAL ANCHORS STRUCTURE i SEE ELEV. FOR SPACING WINDOW WIDTH WINDOW WIDTH rn ^^ .2 PRODUCT REVISED o m o ' as cc m In with the Florida \\\\lll l I I I!!I!!� c i Building Code ' ��\ 9,9. FA NOA-No. 20.1223.01 �����@! 6EN8F' ���, n •o Ex lration Date 5/18/2022 i v By No. 23 miam Lpade PrO1lY4t�t'.e trol DEC 0 1202 � (r{'• (Rj drowInng no. f v •I • EDGE DIST. I METAL MIAMI-DAOE COUNTY APPROVED 1D MULLION &MULLION ANCHORS a� p EDGE DIST. STRUDTURE SEE SEPARATE APPROVAL Z Cs, I EDGE DIST. Q S 2j .1 �0 So 0 0d�` V I O � � H ES. �=mr E5 \ \ V 11 y(m Zm ALT. Q a C o W$$ TYPICAL S EC ELEV.HDRS !TYPICAL SAE EEILEV. TYPICAL SE ELEV. IL 20 FOR SPACING FOR SPACING FOR SPACING 1CJ(00 a 0 a Egg ' � m J YI ' H o � 3 g a � n Z J W a a ° La = a 1/4"MAX. X 0), 3 W SHIMS p`t M m 0 z E5 ALT, 0 Z_3 e W 0 TYPICAL ANCHORS SEE ELEV. to w o R FOR SPACING w 41 LO g d' ° d° d U C$i TYPICAL ANCHORS g SEE ELEV. O FOR SPACING WINDOW WIDTH B 0 0 0 H ALT. PRODUCT REVISED L 0..6 ea eompying with the Florida ���Ttj71I //// ES Building Code '^ NOA-No. 20.1223.01 �����;•uGFNSF• �i� � •o Expiration Date• 5NS/2022 INSTALLATION DETAILS WITH FLUSH FRAME ADAPTERS By' No,e1223 .°..• Nllam adOEP r o ef'C trot 1 .�t SEE SHEETS 4 & 5 FOR WINDOW DETAILS y q��� 0 5 W16-70 EDGE DIST. !/ �� sheet sof 9 { TYPICAL ANCHORS v � � ILLUSTRATIVE DTLS.ONLY SEE SPAC EXT.OR INT. FINISHES .FOR SPACING NOT DY E.S.WOW. i. Z q TYPICAL ANCHORS: SEE ELEV. FOR SPACING f i \\\ 410 WOOD SCREWS(GRADE 2 CRS) p c4,e INTO 28Y WOOD BUCKS OR WOOD STRUCTURES 0 1-1/2" MIN. PENETRATION INTO WOOD (L U O a E6 aI a odoos ALT. C. z #10 TEKS/SELF DRILLING SCREWS AT 6 FROM ENDS 2 �m :Inan AND 12 O.C. MAX. m a HE f k 1/4"MAX. J umi GAP v 1/2"MIN. 3 e N Z Jw O E6 ALT. W n a x O° M z [Wi #10 TEKS/SELF DRILLING SCREWS o ZZ��e § k AT 6 FROM ENDS 3 Z W V (z� AND 12 O.C. MAX. J o W N0 LO w Wr�ig TYPICAL ANCHORS EXTERIOR Ogg, , SEE ELEV. FOR SPACING '3 WINDOW WIDTH fi U U #10 TEKS/SELF DRILLING SCREWS n AT 6 FROM ENDS AND 12 O.C. MAX. O a n n Ny a Oa EB ALT. I PRODUCT ggREVISED a<m a as Building Codewith the Florida 07 i NDA--No. 20-1223.01 `����@'•�jcEN ��� n e Fn (ratio,,n,�Da-t/e�- 5118/2022 :3` Z GhLL[�KL�� _ No.81223 �. INSTALLATION DETAILS WITH FIN FRAME ADAPTERS By: _ Mlam pade Produc�!'Co !roI .. v N SEE SHEETS 4 & 5 FOR WINDOW DETAILS 'E DEC 0 1 203;a. ��•'•, Si Tf.F drawing no. TYPICAL ANCHORS i� � �ORID.K . SEE ELEV. /�®®M1��. W�6-7� FOR SPACING //,,Yllli1111� sheet 7 of g ' 1 r. 2.917 ITEM B PART y REOD. DESCRIPTION MATERIAL MANF./SUPPInR/REMARES 1 E1 • ES-EL151 1 FRAME 6063-T6 - b .050 E2 ES-EL152 AS REOD. FRAME SCREW COVER 6063-T6 - M 1.56237 9� ,j g E4. ES-EU 11 AS ROD. GLAZING BEAD(INSUL.LAM.GLASS) 6063-T6 - I E4A ES-EL116 AS ROD.. GLAZING BEAD(INSUL LAM.GLASS) 6063-T6.062 E5 ES-EL112 AS REOD. FLUSH FRAME ADAPTER - 6063-T61 187-�I E6 ES-EL115 AS REOD. FLUSH FRAME ADAPTER WITH FIN 6063-T6. - aV E7 ES-EL110 AS ROD. GLAZING BEAD(7/16"LAM.GLASS) 6063-TBFRAME E7A ES-EL123 AS ROD. GLAZING BEAD(7/16-LAM.GLASS) 6063-T6Mt #B X 1- - FRAME ASSEMBLY FASTENERS ST.STEEL PH SMS o040 M2 ES-500SA AS REDD. EXTERIOR BULB GASKET SILICONE DUROMETER 60iS SHORE A F417M2AEL100-002 AS REOD. EXTERIOR LEAF GASKET SILICONE DUROMETER 60t5 SHORE A NM2B ES-N-340-G05 AS REOD. EXTERIOR WEDGE GASKET SILICONE OUROMETER 65t5-SHORE A�1.670� M380-372A 2/LITE SETTINGBLOCKAT1POINTS(LAM.GLASS) SILICONE DUROMETER 8055 SHORE A "M4 EU00-0012/LRE SEfiING BLOCK AT 1/4 POINTS(INSUL LAM.GLASS) SNCONE DUROMETER 80t5 SHORE A E2 FRAME SCREW COVER MS R8 X t' - FLUSH/FIN FRAME ADAPTER ASSEMBLY FASTENERS ST.STEEL FH SMS 2.857 fu —F 3 .500 I 825 3 m �F—2.780 FLUSH FRAME ADAPTER j w a 1.428--^I _ 'mod'm I uj X 150)Mn O 0 Z3 1.500 L w Vi In --T w ul .500 .625 T—I .045 . F-2.780 Es FLUSH FRAME ADAPTER WITH FIN z u�o c�W 0 PRODUCT REVISEDasicom In ---++b�.---���II NOA-No. th the Rorlds ",%J1111111 mngftodaWL20.1223.01 �0�� ' ��, .519-I^--�I .579 I I •�I p-.135 -�{�•-'.057 Ex Iration Date• $J1T 022 ��••110EN9F••._," •e I I—( 050 I I I II s �- I 828_D .625 .62�5 .Og2 ' By: A• NO. 3 >; ,050 .974 ,_I .974 �_ .062 974 y_ .974 Mlam ade ProdueYC trol �! -� DEC 0 1 202J' .202 .202 .202 .202 '��®,,;•., :STATED draving no. OE7A E4 taA ®NALL71%%% sheet B of 9 GLAZING BEADS