HomeMy WebLinkAboutAPPROVED, extreme 1ina
BCIS Home Log In User Registration Hot Topics j Submit Surcharge Stats & Facts Publications Contact Us s BCIS Site Map Links Searchtook J
'
b
� Product Approval
- r 4 USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL25621-R2
Revision
2020
Approved
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
fivalidation@yahoo.com
Richard McKuhen
fivalidation@yahoo.com
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By James R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL25621 R2 COI 26ga SnapMax plywood.pdf
Standard
TAS 100
TAS 125
UL 580
Year
1995
2003
2006
Product Approval Method
Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
F` --I
12/16/2020
12/17/2020
12/26/2020
02/09/2021
FL # Model, Number or Name
Description
25621.1 101: 26ga SnapMax on Plywood
26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
N 3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-97.25
Other: Refer to evaluation report
( Installation Instructions
FL25621 R2 II 269a SnapMax plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 26ga SnapMax plywood.pdf
Created by Independent Third Party: Yes
25621.2
02: 032 Aluminum SnapMax on
Plywood
Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-78.5
Other: Refer to evaluation report
Installation Instructions
FL25621 R2 II 032 SnapMax plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 032 SnapMax plywood.pdf
Created by Independent Third Party: Yes
25621.3 03: 032 Aluminum 12" SnapMax on
Plywood
Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
with 12" coverage on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-69.25
Other: Refer to evaluation report
Installation Instructions
FL25621 R2 II 032 SnapMax 12in Plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 032 SnapMax 12in Plywood.pdf
Created by Independent Third Party: Yes
25621.4
�O4�-:26ga SnapMax on Plywood
26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-121.75
Other: Refer to evaluation report
Installation Instructions
FL25621 R2 II 26ga SnapMax plywood D.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
j Evaluation Reports
i FL25621 R2 AE 26ga SnapMax plywood D.pdf
Created by Independent Third Party: Yes
25621.5 �
�05:ga SnapMax on Plywood HVHZT3/4""(min)
6(min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
wood pi
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-176
Other: Refer to evaluation report
Installation Instructions
FL25621 R2 II 26ga SnapMax plywood HVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 26ga SnapMax plywood HVHZ.pdf
Created by Independent Third Party: Yes
25621.6
06: 24ga SnapMax on Plywood
24ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-206
Other: Refer to evaluation report !
Installation Instructions
FL25621 R2 II 24ga SnapMax plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 24ga SnapMax plywood.pdf
Created by Independent Third Party: Yes
EXTREMEMETAL
FABRICATORS
SKrLLS0 cRa was OF r r- ' <: x
26ga (min) SNAP,MAX over 15/32" (min) plywood
Extreme Metal Fabricators
2160 SW Poma Dr I Palm City FL 34990
Product Description
Nailstrip, snaplock style panel with a 16" maximum panel width and a
nominal rib height of 1"
Product Material
26ga (min) steel
Corrosion resistant per FBC 1507.4.3 where required
Fastener
#10 x 1-inch pancake style fastener
Compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Eva I uated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave #206 1 Gainesville FL
FL PE 81377 1 FL CA 33344
www.Ti m be rLa keCove.com
'ko tllll/f,.
Underlayment: Comply with local building code or FBC 1507.1.1 where required.
Slope: Comply with local building code or FBC 1507.4.2 where required.
Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511, provided the existing roof meets the conditions required by
the applicable code.
Maximum Allowable Loads & Installation Requirements:
Method A• #10 x 1" fastener at 6" o.c. along nail strip: 86 PSF
Method B• #10 x 1" fastener at 6" o c along nail strip WITH sealant• 97.25 PSF
For Method B, use continuous 3/16" bead of Bostik 915 sealant or similar.
A factor of safety of 2 has been applied.
Fasteners are installed through the metal flange, NOT through the pre -punched slots.
Technical Documentation:
This product has been tested to the UL 580 standard by Architectural Testing (now Intertek
Testing, TST-1527), report D8133.01-450-18, as referenced in FL 17022.05-R7.
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020,
1504.3.2 (non-HVHZ), as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16.
Use of these tables assumes that the structure is:
Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company
manufacturing or distributing products under this evaluation. The some entities do not have, nor will
acquire, a financial interest in any other entity involved in the approval process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated
weathering/salt spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by
Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based on this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding
performance of this product. Installation shall be subject to the local building code and authority having
jurisdiction; this report shall not be construed to supersede local codes in force.
Instructions:
Select the appropriate load table that applies to the
structure in question.
Determine the design wind speed for the project
location.
Use the attachment method indicated for that
windspeed within each roof zone.
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept.
For the load tables below, the worst case was taken
for each zone and reported using the standard zones
1-2-3:
Zone 1 includes zones 1 and 1'
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple
scheme, at the expense of some design efficiency.
Contact the manufacturer for further information,
or consult a licensed design professional.
METHOD A
T •i
a: 10% OF LEAST HORONTAL DIMENSION OR 0:4h, WHICHEVER IS SMALLER, BUT NOT
LESS THAN EITHER 4% OF LEAST HORIZONTAL DIMENSION OR 3FT (0.%Mj.
OR AS OETERMINEO BY DESIGN OR OTHER APPLICABLE CODE.
ROOF ZONES FOR GENERIC BUILDING
NR: NOT RATED
FEMALE LEO SNAPS _fi FEMALE LEG SNAPS
ONTO MALE LEG - `�.._ ONTO MALE LEG
TSEALANT APPLIED TO
BASE OF MALE LEG
#10 FASTENER __ -- #10 FASTENER
AT 6" O.C. AT &" O.C.
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B, C, or D exposure area
Have either a flat roof, or gable/hip roof with max slope of 12:12 Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
CONSULT DESIGN
PROFESSIONAL AS
NECESSARY
a
FL25621.01: 26cia
Sna
Max on 15/32" plMood
FL25621.01: 26
a Sna Max on 15/32" plywood
Wind 105 110
120 130 140
150 160 170 180 190 200
Wind 105 110
120
130 140 150 160 170 180 190 200
Zone 1: A A
A
A
A
A A A A A A
Zone 1: A A
A
A A A A B-
Zone 2: A A
A
A
A
A A A B
Zone 2: A A
A
A B .
Zone 3: A A
A
A
A
A B 0 r M IS I
Zone 3: A A
A
B
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B, C, or D exposure area
Have either a flat roof less than 7°, hip roof with Have either a flat roof less than 7°, hip roof with
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A B
Zone 2: A A A A A A A A A B Zone 2: A A A A A B �-
Zone 3: A A A A A A A B Zone 3: A A A B M,