HomeMy WebLinkAboutAPPROVED A-5.01TOP OF PARAPET WALL
@ EL. 14'-0" A.F.F.
A
60 mil TPO ROOF MEMBRANE SYSTEM OVER
RIGID INSULATION (R-20 MIN.) ON %s" CDX
PLYWOOD ROOF SHEATHING - ATTACHMENT
PER STRUCTURAL SPECIFICATIONS
BOTTOM OF SLOPED ROOF
@ L. 1 V-10" A.F.F.
1X4 P.T. FASCIA WITH PAINTED
METAL FLASHING INTEGRATED
WITH ROOF GUTTER
GUTTER SYSTEMS - COLOR TO
MATCH FASCIA
2x6 P.T. SUB -FASCIA ATTACHED
TO RAFTERS
BOTTOM OF TRUSSES _
71@ EL. +/- 10'-0" A. F. F.
3 PART SMOOTH STUCCO OVER PAPER BACKED WIRE LATH
ON 15# FELT OVER 1%2" CDX PLYWOOD SHEATHING ON %4"
FURRING @ 16" O.C., MAX SPACING
ACT CEILING
@ EL. 9'-0" A.F.F.
2x8 P.T. LEG @ END OF TRUSS
WIRE MESH LATH AT ALL MATERIAL
CHANGE JOINTS FOR CRACK
PREVENTION - MIN. 12"
EXISTING BOND BEAM TO REMAIN V.I.F.
BOTTOM OF BEAM V.I.F.
@ EL. +/- 7'-0" A.F.F.
RETURN STUCCO TO
WINDOW HEAD
1X P.T. BUCK
ROOF SLOPES DOWN %" PER FOOT MIN
x
STUCCO FINISH AT
TOWER BEYOND
ROOF SLOPES DOWN %" PER FOOT MIN 60 mil TPO ROOF MEMBRANE
SYSTEM OVER RIGID INSULATION
(R-20 MIN.) ON %" CDX PLYWOOD
ROOF SHEATHING - ATTACHMENT
.. .... w PER STRUCTURAL SPECIFICATIONS
PRE -FABRICATED WOOD USSE @ 24" O.C.
MAX SPACING - E ST TURAL
ENGINEERING D WINff�ON
R FURTHER
PRE- BRIC ED WOOD TRUS ES 24" O.C. FOR
M SPACING - SEE STRU URA
EN EERING DRAWINGS FOR F RTH
INFORMATION
BOTTOM OF TRUSSES
'4111-@ EL. +/- 10'-0" A.F.F.
ACT CEILING
MV @ EL. 9'-0" A.F.F.
o
SCHEDULED SUSPENDED
ACOUSTIC TILE CEILING SYSTEM
2X8 CONTINUOUS SILL PLATES
- SEE STRUCTURAL DRAWINGS
FOR CONNECTORS &
-+ FASTENING REQUIREMENTS
V GYP BOARD ON 20 GA. 1 %2"
FURRING CHANNELS @ 16" O.C.
MAX WITH R-4 MIN FI-FOIL
INSULATION
PAINTED WOOD JAMB AND
CASING - I.D. TO SELECT
TRIM PROFILES
SCHEDULED WINDOW
1X P.T. BUCK
PAINTED WOOD SILL & APRON
SLOPE STUCCO AWAY FROM WINDOW
- I.D. TO SELECT TRIM PROFILES
WORK AREA
OFFICE
113
106
SILL HEIGHT
OPEN TO
BEYOND
'RV@ EL. 4'- 0" A.F.F. —
FLUID APPLIED WEATHER
PROOFING MEMBRANE FLASHING
FROM INSIDE OF BUCK TO 12" j
AROUND ROUGH OPENING
°
EXISTING 8" CMU WALL TO REMAIN
a
%" GYP BOARD ON 20 GA. 1%2"
° a
FURRING CHANNELS @ 16" O.C.
CONTINUOUS VINYL WEEP SCREED
MAX WITH R-4 MIN FI-FOIL
� °
@ BASE OF STUCCO FINISH
INSULATION
EXISTING SLAB FOUNDATION
��Ia
PAINTED WOOD BASE MOLDING
TO REMAIN
- I.D. SELECTED PROFILE
ill
all°
I.D. SELECTED CARPET TILE
SPLASH BLOCK AT BASE OF
EACH RAINLEADER —i
D
\
0
FINISH FLOOR 1I"°e :11 m 1111111 MuV 011 AmWniuniunu11MMIMyV/Xt MmWVRniununMnumiMnuiniuAlM iV
@EL. 0'-0"A.F.F• -----
ER� T W c/o EX/
�E R \ \
\ \ \ \ \ \
WALL SECTION
SCALE: 1" = 1'-0" A-5.01
I.D. SELECTED CARPET TILE
EXISTING SLAB ON GRADE °
TO REMAIN
\T M�R EEL /
C C T 7 \
WALL SECTION 2
SCALE: 1" = 1'-0" A-5.01
60 mil TPO ROOF MEMBRANE
SYSTEM OVER 1%2'CDX
PLYWOOD ROOF SHEATHING -
ATTACHMENT PER
STRUCTURAL SPECIFICATIONS
jk BOTTOM OF TRUSSES
@ EL. +/- 10'-0" A.F.F. SIMPSON STRAP AND CLIP
AT EACH LEG OF TRUSS
3 %" X 20 GA TOP TRACK - SEE STRUCTURAL
ATTACHED TO EACH TRUSS DRAWINGS FOR
@ INTERIOR WALLS INFORMATION
FACT CEILING l�
@ EL. 9'-0" A.F.F.
SCHEDULED SUSPENDED SCHEDULED SUSPENDED
ACOUSTIC TILE CEILING ACOUSTIC TILE CEILING
SYSTEM SYSTEM
EXISTING 8X16 CONCRETE
INTERIOR WALLS WITH %s" GYP
BEAM TO REMAIN V.I.F.
BOARD ON EACH SIDE OF
3 Vx20 GA METAL STUDS @ 16" O.C.
%s" GYP BOARD ON 20 GA.
MAXIMUM SPACING
1%2" FURRING CHANNELS @
16" O.C. MAX WITH R-4 MIN
PAINTED WOOD DOOR CASING
FI-FOIL INSULATION
- I.D. TO SELECT PROFILE
PAINTED WOOD JAMB AND
CASING - I.D. TO SELECT
SCHEDULED FRENCH DOOR
TRIM PROFILES
RETURN STUCCO TO
WINDOW HEAD
SCHEDULED WINDOW
OFFICE
106
1X P.T. BUCK
PAINTED WOOD SILL &
APRON - I.D. TO SELECT
TRIM PROFILES
CONTINUOUS PAINTED CAP FLASHING WITH
DRIP EDGES, FASTENED TO TOP PLATE
PAINTED METAL FLASHING
WITH DRIP EDGE OVER
ROOF MEMBRANE TURNED
UP CANT STRIP COVER
WITH COUNTER FLASHING
ROOF SLOPES DOWN %" PER FOOT MIN
Y4" PLYWOOD FIRE BLOCKING
CONTINUOUS FROM TIE BEAM
TO UNDERSIDE OF ROOF
SHEATHING
1
/AB D WOOD RUSSES @ 24" O.C.
ING - SE STRUCTURAL
DRAWI S FOR FURTHER
INFORMA ION
BLOCKING BETWEEN
2X8 CONTINUOUS SILL PLATES----
- SEES I RUC I URA
DRAWINGS
FOR CONNECTORS &
D '
FASTENING REQUIREMENTS
2X8 P.T. WOOD FRAMING
ATTACHED TO EXISTING BEAM
D �:
•ID
2X8 @ 24" O.C. ATTACHED TO
D
VERTICAL LEG OF TRUSS -
SLOPE
f—
�m
d E a U
3 E a
U
72
c .3 h -
=Ey
2X4 CONTINUOUSWOOD TOP
N
PLATE, ATTACHED WITH WOOD
SCREWS TO EACH TRUSS - SEE
STRUCTURAL DRAWINGS FOR
MORE INFORMATION
Z
O
_ TOP OF PARAPET WALL
U
@ EL. 14'-0" A.F.F.
�
C/)
Z
0
TOP OF SLOPED ROOF
0
@ EL. +/- 13'-0" A.F.F.
0
O
LL_
H
W
U)
J
H
H
m
ZD
U)
VERTICAL LEG OF TRUSS
W
3 PART SMOOTH STUCCO OVER
CV
PAPER BACKED WIRE LATH ON
N
1%2 CDX PLYWOOD SHEATHING
CD
1" ANODIZED ALUMINUM
6„ CHANNEL ATTACHED TO
SUBSTRATE
TOP OF OVERHANG OIL
@ EL. 8'-0" A.F.F.
A �,J
GYP BOARD ON 20 GA. D —mower �- —
1%2' FURRING CHANNELS @ e` ��° 2
16" O.C. MAX WITH R-4 MIN D .�D
FI-FOIL INSULATION
pall II
Il
EXISTING 8" CMU WALL TO
PAINTED WOOD TRANSITION REMAIN
STRIP @ DOOR THRESHOLD �l
PAINTED WOOD BASE
MOLDING - I.D. TO `y
PAINTED WOOD BASE MOLDING SELECT PROFILE
- I.D. TO SELECT PROFILE I.D. SELECTED WOOD
TILE
I.D. SELECTED WOOD I
TILE
•D
. P' ° D "° '. a \° ° ° •Ile D. ' °
EXISTING SLAB ON GRADE
u : b
AND FOUNDATION TO
REMAIN
/\\ R T�I A �L \ACQT lR I� \ \ X
WALL SECTION 3
SCALE: 1" = V-0" A-5.01
— BOTTOM OF BEAM V.I.F.
@ EL. +/- 7'-0" A.F.F.
1%2" CDX PLYWOOD
SHEATHING ATTACHED TO
UNDER SIDE OF EAVES
BUILT-UP STUCCO SILL /
BAND - SLOPE STUCCO
AWAY FROM WINDOW
SILL HEIGHT
@ EL. 2'- 8" A.F.F.
FLUID APPLIED WEATHER
PROOFING MEMBRANE FLASHING
FROM INSIDE OF BUCK TO 12"
AROUND ROUGH OPENING
WOOD LOOK TILE WALL
SURFACE
POURED CONCRETE CURB
FINISH FLOOR_
@ EL. 0'-0" A.F.F.
ASPHALT PARKING LOT
Digitally signed by
Brent Brent Wood
DN: cn=Brent Wood,
o=Brent A. Wood
Architecture, LLC, ou,
W O od
email=brent@bawood
arch.com, c=US
Date: 2021.04.29
14:08:33-04'00'
N
N
O
J
F
G
m
Z)
co
G
Of
LL
0-
4;
(A
m
EF
0
�
❑
N
0
N
M
00
N
O
N
�
(n
V)
Z
Z
L.I
L.I
12
0
CO
U
❑
00
u
U
0
N
M
.4
In
rD
W
J
w
z
z
olf
LL
U
E LU
z CO
t
a>
'o
a
v
� M
�Lq
Q X
Z > Li
❑ Lb
00
@o
Q U N
ON
w (Wn r
ir O w
m N F
ti
rn
W M
>Q
z
0
U LL
OU
=a
DW
0 co
U)�W
Mc\j U)
O z
W
rl-
In
W M
>Q
ZO
ULL
OV
=a
~ LL
0 O mZ
�W
do U)
o w
Lo
0
N
C\jN j
d)
O
N
Q
ID
E O m
-
3
0
Z c i Ln
v I
� p N
y
O
p p N
o
6- @