Loading...
HomeMy WebLinkAboutAPPROVED A-5.01TOP OF PARAPET WALL @ EL. 14'-0" A.F.F. A 60 mil TPO ROOF MEMBRANE SYSTEM OVER RIGID INSULATION (R-20 MIN.) ON %s" CDX PLYWOOD ROOF SHEATHING - ATTACHMENT PER STRUCTURAL SPECIFICATIONS BOTTOM OF SLOPED ROOF @ L. 1 V-10" A.F.F. 1X4 P.T. FASCIA WITH PAINTED METAL FLASHING INTEGRATED WITH ROOF GUTTER GUTTER SYSTEMS - COLOR TO MATCH FASCIA 2x6 P.T. SUB -FASCIA ATTACHED TO RAFTERS BOTTOM OF TRUSSES _ 7­1@ EL. +/- 10'-0" A. F. F. 3 PART SMOOTH STUCCO OVER PAPER BACKED WIRE LATH ON 15# FELT OVER 1%2" CDX PLYWOOD SHEATHING ON %4" FURRING @ 16" O.C., MAX SPACING ACT CEILING @ EL. 9'-0" A.F.F. 2x8 P.T. LEG @ END OF TRUSS WIRE MESH LATH AT ALL MATERIAL CHANGE JOINTS FOR CRACK PREVENTION - MIN. 12" EXISTING BOND BEAM TO REMAIN V.I.F. BOTTOM OF BEAM V.I.F. @ EL. +/- 7'-0" A.F.F. RETURN STUCCO TO WINDOW HEAD 1X P.T. BUCK ROOF SLOPES DOWN %" PER FOOT MIN x STUCCO FINISH AT TOWER BEYOND ROOF SLOPES DOWN %" PER FOOT MIN 60 mil TPO ROOF MEMBRANE SYSTEM OVER RIGID INSULATION (R-20 MIN.) ON %" CDX PLYWOOD ROOF SHEATHING - ATTACHMENT .. .... w PER STRUCTURAL SPECIFICATIONS PRE -FABRICATED WOOD USSE @ 24" O.C. MAX SPACING - E ST TURAL ENGINEERING D WINff�ON R FURTHER PRE- BRIC ED WOOD TRUS ES 24" O.C. FOR M SPACING - SEE STRU URA EN EERING DRAWINGS FOR F RTH INFORMATION BOTTOM OF TRUSSES '4111-@ EL. +/- 10'-0" A.F.F. ACT CEILING MV @ EL. 9'-0" A.F.F. o SCHEDULED SUSPENDED ACOUSTIC TILE CEILING SYSTEM 2X8 CONTINUOUS SILL PLATES - SEE STRUCTURAL DRAWINGS FOR CONNECTORS & -+ FASTENING REQUIREMENTS V GYP BOARD ON 20 GA. 1 %2" FURRING CHANNELS @ 16" O.C. MAX WITH R-4 MIN FI-FOIL INSULATION PAINTED WOOD JAMB AND CASING - I.D. TO SELECT TRIM PROFILES SCHEDULED WINDOW 1X P.T. BUCK PAINTED WOOD SILL & APRON SLOPE STUCCO AWAY FROM WINDOW - I.D. TO SELECT TRIM PROFILES WORK AREA OFFICE 113 106 SILL HEIGHT OPEN TO BEYOND 'RV@ EL. 4'- 0" A.F.F. — FLUID APPLIED WEATHER PROOFING MEMBRANE FLASHING FROM INSIDE OF BUCK TO 12" j AROUND ROUGH OPENING ° EXISTING 8" CMU WALL TO REMAIN a %" GYP BOARD ON 20 GA. 1%2" ° a FURRING CHANNELS @ 16" O.C. CONTINUOUS VINYL WEEP SCREED MAX WITH R-4 MIN FI-FOIL � ° @ BASE OF STUCCO FINISH INSULATION EXISTING SLAB FOUNDATION ��Ia PAINTED WOOD BASE MOLDING TO REMAIN - I.D. SELECTED PROFILE ill all° I.D. SELECTED CARPET TILE SPLASH BLOCK AT BASE OF EACH RAINLEADER —i D \ 0 FINISH FLOOR 1I"°e :11 m 1111111 MuV 011 AmWniuniunu11MMIMyV/Xt MmWVRniununMnumiMnuiniuAlM iV @EL. 0'-0"A.F.F• ----- ER� T W c/o EX/ �E R \ \ \ \ \ \ \ \ WALL SECTION SCALE: 1" = 1'-0" A-5.01 I.D. SELECTED CARPET TILE EXISTING SLAB ON GRADE ° TO REMAIN \T M�R EEL / C C T 7 \ WALL SECTION 2 SCALE: 1" = 1'-0" A-5.01 60 mil TPO ROOF MEMBRANE SYSTEM OVER 1%2'CDX PLYWOOD ROOF SHEATHING - ATTACHMENT PER STRUCTURAL SPECIFICATIONS jk BOTTOM OF TRUSSES @ EL. +/- 10'-0" A.F.F. SIMPSON STRAP AND CLIP AT EACH LEG OF TRUSS 3 %" X 20 GA TOP TRACK - SEE STRUCTURAL ATTACHED TO EACH TRUSS DRAWINGS FOR @ INTERIOR WALLS INFORMATION FACT CEILING l� @ EL. 9'-0" A.F.F. SCHEDULED SUSPENDED SCHEDULED SUSPENDED ACOUSTIC TILE CEILING ACOUSTIC TILE CEILING SYSTEM SYSTEM EXISTING 8X16 CONCRETE INTERIOR WALLS WITH %s" GYP BEAM TO REMAIN V.I.F. BOARD ON EACH SIDE OF 3 Vx20 GA METAL STUDS @ 16" O.C. %s" GYP BOARD ON 20 GA. MAXIMUM SPACING 1%2" FURRING CHANNELS @ 16" O.C. MAX WITH R-4 MIN PAINTED WOOD DOOR CASING FI-FOIL INSULATION - I.D. TO SELECT PROFILE PAINTED WOOD JAMB AND CASING - I.D. TO SELECT SCHEDULED FRENCH DOOR TRIM PROFILES RETURN STUCCO TO WINDOW HEAD SCHEDULED WINDOW OFFICE 106 1X P.T. BUCK PAINTED WOOD SILL & APRON - I.D. TO SELECT TRIM PROFILES CONTINUOUS PAINTED CAP FLASHING WITH DRIP EDGES, FASTENED TO TOP PLATE PAINTED METAL FLASHING WITH DRIP EDGE OVER ROOF MEMBRANE TURNED UP CANT STRIP COVER WITH COUNTER FLASHING ROOF SLOPES DOWN %" PER FOOT MIN Y4" PLYWOOD FIRE BLOCKING CONTINUOUS FROM TIE BEAM TO UNDERSIDE OF ROOF SHEATHING 1 /AB D WOOD RUSSES @ 24" O.C. ING - SE STRUCTURAL DRAWI S FOR FURTHER INFORMA ION BLOCKING BETWEEN 2X8 CONTINUOUS SILL PLATES---- - SEES I RUC I URA DRAWINGS FOR CONNECTORS & D ' FASTENING REQUIREMENTS 2X8 P.T. WOOD FRAMING ATTACHED TO EXISTING BEAM D �: •ID 2X8 @ 24" O.C. ATTACHED TO D VERTICAL LEG OF TRUSS - SLOPE f— �m d E a U 3 E a U 72 c .3 h - =Ey 2X4 CONTINUOUSWOOD TOP N PLATE, ATTACHED WITH WOOD SCREWS TO EACH TRUSS - SEE STRUCTURAL DRAWINGS FOR MORE INFORMATION Z O _ TOP OF PARAPET WALL U @ EL. 14'-0" A.F.F. � C/) Z 0 TOP OF SLOPED ROOF 0 @ EL. +/- 13'-0" A.F.F. 0 O LL_ H W U) J H H m ZD U) VERTICAL LEG OF TRUSS W 3 PART SMOOTH STUCCO OVER CV PAPER BACKED WIRE LATH ON N 1%2 CDX PLYWOOD SHEATHING CD 1" ANODIZED ALUMINUM 6„ CHANNEL ATTACHED TO SUBSTRATE TOP OF OVERHANG OIL @ EL. 8'-0" A.F.F. A �,J GYP BOARD ON 20 GA. D —mower �- — 1%2' FURRING CHANNELS @ e` ��° 2 16" O.C. MAX WITH R-4 MIN D .�D FI-FOIL INSULATION pall II Il EXISTING 8" CMU WALL TO PAINTED WOOD TRANSITION REMAIN STRIP @ DOOR THRESHOLD �l PAINTED WOOD BASE MOLDING - I.D. TO `y PAINTED WOOD BASE MOLDING SELECT PROFILE - I.D. TO SELECT PROFILE I.D. SELECTED WOOD TILE I.D. SELECTED WOOD I TILE •D . P' ° D "° '. a \° ° ° •Ile D. ' ° EXISTING SLAB ON GRADE u : b AND FOUNDATION TO REMAIN /\\ R T�I A �L \ACQT lR I� \ \ X WALL SECTION 3 SCALE: 1" = V-0" A-5.01 — BOTTOM OF BEAM V.I.F. @ EL. +/- 7'-0" A.F.F. 1%2" CDX PLYWOOD SHEATHING ATTACHED TO UNDER SIDE OF EAVES BUILT-UP STUCCO SILL / BAND - SLOPE STUCCO AWAY FROM WINDOW SILL HEIGHT @ EL. 2'- 8" A.F.F. FLUID APPLIED WEATHER PROOFING MEMBRANE FLASHING FROM INSIDE OF BUCK TO 12" AROUND ROUGH OPENING WOOD LOOK TILE WALL SURFACE POURED CONCRETE CURB FINISH FLOOR_ @ EL. 0'-0" A.F.F. ASPHALT PARKING LOT Digitally signed by Brent Brent Wood DN: cn=Brent Wood, o=Brent A. Wood Architecture, LLC, ou, W O od email=brent@bawood arch.com, c=US Date: 2021.04.29 14:08:33-04'00' N N O J F G m Z) co G Of LL 0- 4; (A m EF 0 � ❑ N 0 N M 00 N O N � (n V) Z Z L.I L.I 12 0 CO U ❑ 00 u U 0 N M .4 In rD W J w z z olf LL U E LU z CO t a> 'o a v � M �Lq Q X Z > Li ❑ Lb 00 @o Q U N ON w (Wn r ir O w m N F ti rn W M >Q z 0 U LL OU =a DW 0 co U)�W Mc\j U) O z W rl- In W M >Q ZO ULL OV =a ~ LL 0 O mZ �W do U) o w Lo 0 N C\jN j d) O N Q ID E O m - 3 0 Z c i Ln v I � p N y O p p N o 6- @