Loading...
HomeMy WebLinkAboutAPPROVED E-5NO.DATEDRREVISIONSCKAPP315 South 7th Street Phone: 772 672-4636 Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173 Engineering, Inc.BEACH FRONT MANN REALTYBRENT A. WOOD ARCHITECTUREC.TIM O T H Y TR E WYNREENIGNELANOIS SEFORP L I C ENS E F LO R I D A No. 61580 STATE OF *Defaults to vacancy sensor mode Manual On/Automatic Off (all loads) for maximum energy savings 1 2 3 4 5 6 Integration ControlsAdjustable SkylightsLow EndHigh EndEnergyOptionsStatusReset0-10V GainAdjustmentDimmer 3 Dimmer 2 Dimmer 1+--++- 0-10V Dimming 0-10V Dimming Outputs-+ Dimmer 3 Dimmer 2 Dimmer 1 -++-Blue - EM Line InBlue - EM Loads OutCAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation.Black - Line InWhite/Black - 120V NWhite/Orange - 277V NBlue - Load InYellow - Load 1 OutRed - Load 2 OutPurple - Load 3 OutEnergy Options DIP Switch Demand Response Occupancy Not Used 1 2 3 4 Default 10% 20% 30% 40% Occ Vac (default) Time Clock Alert Mode Demand Response A/V Mode +-Integration Controls+-+-+- Green Black Red White Adjustable SkylightsSensors Receptacle BMS/Out Switchpack QuickConnect CablesSensors Slider Station Wallstations BLACK - Hot (120/277VAC) WHT/ORG or WHT/BLK Neutral BLUE - Relay In (120/277VAC)OCC-RJ45 (Occupancy Coupler)Model: OCC-RJ45Occupancy Sensor CouplerBrownBlackRedBlue*Allows connection to any Greengate Occupancy/Vacancy Sensor. LIGHTING LOAD (1)YELLOW RED *0-10V Dimming Zone Note: The 0-10V dimming zones within the Room Controller can be wired and controlled independent of the connected loads. This allows a each load to have a dedicated 0-10V dimming zone or a single load to have up to three 0-10V dimming zones. Quick connect cables are pre-terminated and included in the Room Controller QuicKit and measured to fit typical room layouts Gray - Dimmer 1 Gray - Dimmer 2 Violet - Dimmer 2 LIGHTING LOAD (2) SPRC-R-20-120 20A Receptacle Control 120V receptacle circuit Receptacle Control: 20Amp 120VAC receptacle control immediately works upon power up and connection to the Room Controller. Receptacle turns On by button press or occupancy and Off when space is vacant. The Room Controller connects up to five Receptacle Control Switchpacks for control of 20A receptacle circuits. CONFERENCE ROOM - ROOM CONTROLLER DIAGRAM Violet - Dimmer 2 WAITING/RECEPTION - ROOM CONTROLLER DIAGRAM Connect up to four wallstations per Room Controller 1 2 3 4 5 6 Integration ControlsAdjustable SkylightsLow EndHigh EndEnergyOptionsStatusReset0-10V GainAdjustmentDimmer 3 Dimmer 2 Dimmer 1 +--++- 0-10V Dimming 0-10V Dimming Outputs -+ Dimmer 3 Dimmer 2 Dimmer 1 -++-Blue - EM Line InBlue - EM Loads OutCAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation.Black - Line InWhite/Black - 120V NWhite/Orange - 277V NBlue - Load InYellow - Load 1 OutRed - Load 2 OutPurple - Load 3 OutEnergy Options DIP Switch Demand Response Occupancy Not Used 1 2 3 4 Default 10% 20% 30% 40% Occ Vac (default) Time Clock Alert Mode Demand Response A/V Mode +-Integration Controls+- +-+- Green Black Red White Adjustable SkylightsSensors Receptacle BMS/Out Switchpack QuickConnect CablesSensors Slider Station Wallstations BLACK - Hot (120/277VAC) WHT/ORG or WHT/BLK Neutral BLUE - Relay In (120/277VAC) LIGHTING LOAD (1) YELLOW RED Quick connect cables are pre-terminated and included in the Room Controller QuicKit and measured to fit typical room layouts LIGHTING LOAD (2) *Defaults to vacancy sensor mode Manual On/Automatic Off (all loads) for maximum energy savings OCC-RJ45 (Occupancy Coupler)Model: OCC-RJ45Occupancy Sensor CouplerBrownBlackRedBlue*Allows connection to any Greengate Occupancy/Vacancy Sensor. SPRC-R-20-120 20A Receptacle Control 120V receptacle circuit Receptacle Control: 20Amp 120VAC receptacle control immediately works upon power up and connection to the Room Controller. Receptacle turns On by button press or occupancy and Off when space is vacant. *0-10V Dimming Zone Note: The 0-10V dimming zones within the Room Controller can be wired and controlled independent of the connected loads. This allows a each load to have a dedicated 0-10V dimming zone or a single load to have up to three 0-10V dimming zones.Gray - Dimmer 1 Gray - Dimmer 3 Violet - Dimmer 2 Violet - Dimmer 3 Violet - Dimmer 1 Gray - Dimmer 1 *Defaults to vacancy sensor mode Manual On/Automatic Off (all loads) for maximum energy savings 1 2 3 4 5 6 Integration ControlsAdjustable SkylightsLow EndHigh EndEnergyOptionsStatusReset0-10V GainAdjustmentDimmer 3 Dimmer 2 Dimmer 1 +--++- 0-10V Dimming 0-10V Dimming Outputs -+ Dimmer 3 Dimmer 2 Dimmer 1 -++-Blue - EM Line InBlue - EM Loads OutCAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation.Black - Line InWhite/Black - 120V NWhite/Orange - 277V NBlue - Load InYellow - Load 1 OutRed - Load 2 OutPurple - Load 3 OutEnergy Options DIP Switch Demand Response Occupancy Not Used 1 2 3 4 Default 10% 20% 30% 40% Occ Vac (default) Time Clock Alert Mode Demand Response A/V Mode +-Integration Controls+- +-+- Green Black Red White Adjustable SkylightsSensors Receptacle BMS/Out Switchpack QuickConnect CablesSensors Slider Station Wallstations BLACK - Hot (120/277VAC) WHT/ORG or WHT/BLK Neutral BLUE - Relay In (120/277VAC) OCC-RJ45 (Occupancy Coupler)Model: OCC-RJ45Occupancy Sensor CouplerBrownBlackRedBlue*Allows connection to any Greengate Occupancy/Vacancy Sensor. LIGHTING LOAD (1)YELLOW RED *0-10V Dimming Zone Note: The 0-10V dimming zones within the Room Controller can be wired and controlled independent of the connected loads. This allows a each load to have a dedicated 0-10V dimming zone or a single load to have up to three 0-10V dimming zones. Quick connect cables are pre-terminated and included in the Room Controller QuicKit and measured to fit typical room layouts LIGHTING LOAD (2) SPRC-R-20-120 20A Receptacle Control 120V receptacle circuit Receptacle Control: 20Amp 120VAC receptacle control immediately works upon power up and connection to the Room Controller. Receptacle turns On by button press or occupancy and Off when space is vacant. The Room Controller connects up to five Receptacle Control Switchpacks for control of 20A receptacle circuits. CONFERENCE ROOM - ROOM CONTROLLER DIAGRAM Gray - Dimmer 1 Gray - Dimmer 2 Violet - Dimmer 1 Violet - Dimmer 2 Relay Panel with 8 latching relays and astronomical timeclock SYMBOL CONTROLS LEGEND MODEL/DESCRIPTION S RCD1,2 RCD SPRC-R-20-120 ROOM CONTROLLER RECEPTACLE RATED SWITCHPACK SPRC OCC D1 ² DT1-R R D1LV L S PPS-5 1 2 3 Notes Refer to plans for locations, size, and quantity. Refer to all manufacturers installation instructions for correct wiring information This one-line drawing is for concept only. Every wire is not shown. Wire according to the product installation/wiring instructions. Cables LV3 Low Voltage Input wire - #18 AWG, 3 conductor wire PPS-5 P2-17 P2-17 P2-17 P2-19 S RCD1,2 S S R R DT1-R DT1-R R S RCD1,2 ROOM CONTROLLER SYSTEM NOTES LK8-LRC Relay Panel with 8 latching relays and astronomical timeclock