HomeMy WebLinkAboutAPPROVED LS-1.11SIGN NO. FTP-21-06
AND FTP-22-06
�2" TYP.
J
J J
J <
H
U) 0
d �
Q Q
U �
Z
z�
QU)
_�
U--
Lu
m �
FTP-21-06 TOP
PARKING BY
DISABLED
PERMIT
ONLY
$250 FINE
F.S. 318.18
FTP-22-06 BOT
NOTES:
1. HANDICAP STALL IS BASED FROM FDOT STANDARD INDEX
#17346
2. DIMENSIONS ARE TO THE CENTERLINE OF MARKINGS.
3. BLUE PAVEMENT MARKINGS SHALL BE TINTED TO MATCH
SHADE 15180 OF FEDERAL STANDARDS 595a.
4. FTP-22-06 PANEL SHALL BE MOUNTED BELOW THE FTP-21-06
SIGN.
5. FOR DESIGN OF THE UNIVERSAL SYMBOL OF ACCESSIBILITY,
REFERENCE FDOT STANDARD INDEX #17346 A
6. FOR DESIGN OF THE ASSOCIATED SIGNS, REFERENCE FDOT A-2.01
STANDARD INDEX #17355
HANDICAP SPACE DETAIL
N.T.S.
rD
A-2.01 EGRESS
CAPACITY:
72" / .2 = 360
H.B.
u ❑
RECEPTION OFFICE
102 103
H.B.
BUILDING CODE ANALYSIS
SECTION 1004 - OCCUPANT LOAD:
TABLE 1004.1.1 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT:
FUNCTION OF SPACE - FLOOR AREA PER OCCUPANT AREAS PER USE NUMBER OF OCCUPANTS
BUSINESS AREAS (B) : 150 GROSS SF 1,529 SF 10.2 OCCUPANTS
ASSEMBLY AREAS (A) : 15 NET SF 303 SF 20.2 OCCUPANTS
TOTAL OCCUPANT LOAD: 30.2 OCCUPANTS
SECTION 1005 EGRESS WIDTH:
TABLE 1005.1 EGRESS WIDTH PER OCCUPANT SERVED
INCHES PER OCCUPANT
STAIRWAYS
OTHER EGRESS
COMPONENTS
0.3
0.2
* SEE SHEET: "LS-1" FOR EGRESS WIDTHS PROVIDED
SMAL CONFERE CIE ROOM
104
� Oo
♦ �O
WAITING ♦
101 ♦ I+I _ _ _ _ EGRESS DISTANCE = 41'-0"
EGRESS DISTANCE = 52'-8_' 17 I�ES "COMMON PATH"
INCLUDES "COMMON PATH"
O
REST ROOM O O 0
109 O O O
0
o0
I
oo I O O O
O
REST ROOM
110
WORK AREA
OFFICE
105
TOTAL OCCUPANT LOAD:
31 OCCUPANTS
x 0.2" PER OCCUPANT
TOTAL EGRESS WIDTH:
Oo Oo
EGRESS DISTANCE = 61'-6"
OFFICE
06 1
113 _ _
INCLUDES "COMMON PATH"
EGRESS DISTANCE = 36-0"
INCLUDES "COMMON PATH"
JANITOR FnE
112 BREAK ROOM
A/C 111 O O O o BBBB o O O O
108 00 00 00 Do Do Do
E0__ �
�J
H.B.
m.
H.B.
EGRESS
CAPACITY:
36" / .2 = 180
FLOOR PLAN 1
SCALE: 1/4" = V-0" LS-1.11
NORTH
WALL TYPE LEGEND
SYMBOL
DESCRIPTION
EXISTING FURRED, 8" CMU EXTERIOR WALWITH NEW GLAZING
EXISTING FRAMED INTERIOR WALL TO REMAIN
NEW, 8" CMU WALL WITH FILLED CELS AND REINFORCING. 1 %2"
METAL FURRING STRIPS @ 16" O.C. MAX. SPACING WITH R-4.5
MIN. RIGID INSULATION BOARD AND %" GYP. BD.
NEW 3 5/8" METAL STUD WALL WITH %$" GYPSUM BOARD
SHEATHING, BOTH SIDES OF WALL
NEW 3 5/8" METAL STUD WALL WITH %" GYPSUM BOARD
SHEATHING, BOTH SIDES OF WALL AND SOUND ATTENUATING
FIBER GLASS BATT INSULATION BETWEEN STUDS.
LIFE SAFETY SYMBOLS
F.E.
>
WALL MOUNTED FIRE EXTINGUISHER
DIRECTION OF EGRESS
NEW 1 HOUR FIRE RATED PARTITION / TENANT DEMISING WALL
�- - -
PATH OF TRAVEL
EXIT LIGHT SYMBOLS
COMBINATION EXIT, EMERGENCY LIGHT FIXTURE
II EMERGENCY LIGHT FIXTURE, WALL PACK WITH TWIN HEADS
LIFE SAFETY NOTES
OCCUPANCY LOAD BASED ON (FBC 2020 CHAPTER 10, TABLE 1004.1.1) SEE OCCUPANCY
CALCULATIONS LISTED.
EGRESS DOORS SHALL OPEN IN THE DIRECTION OF EGRESS. (7.2.1.4.2)
EGRESS DOORS SHALL HAVE PANIC HARDWARE. (13.2.2.2.4) RELEASE MECHANISMS ON
DOORS SHALL BE MOUNTED BETWEEN 34" AND 48" A.F.F. (7.2.1.7.1)
DURING ITS SWING ANY DOOR IN A MEANS OF EGRESS SHALL LEAVE NOT LESS THAN
ONE-HALF OF THE REQUIRED WIDTH OF AN AISLE, CORRIDOR, PASSAGEWAY, OR
LANDING UNOBSTRUCTED AND SHALL PROJECT NOT MORE THAN 7" INTO THE REQUIRED
WIDTH. (7.2.1.4.3.1)
THE FORCE REQUIRED TO OPEN ANY DOOR MANUALLY IN A MEANS OF EGRESS SHALL
NOT EXCEED 15# TO RELEASE THE LATCH AND 30# TO SET THE DOOR IN MOTION.
(7.2.1.4.5)
OPENING FORCE FOR INTERIOR DOORS WITHOUT CLOSERS SHALL NOT EXCEED 5#.
DEAD END CORRIDORS SHALL NOT EXCEED 50 FEET.
COMMON PATHS OF TRAVEL SHALL NOT EXCEED 100 FEET.
TRAVEL DISTANCE TO AN EXIT SHALL BE LESS THAN 250'.
AISLES SHALL NOT BE LESS THAN 36".
MANUAL FIRE EXTINGUISHER LOCATIONS MOUNTED WITH OPERABLE CONTROLS AT 48"
A.F.F. - MAXIMUM SPACING 75-0".
FIRE EXTINGUISHERS SHALL BE CURRENTLY DATED AND TAGGED BY A LICENSED FIRE
EQUIPMENT COMPANY.
G.C. SHALL ENSURE ALL NEW LIFE SAFETY DEVICES MEET OR EXCEED MINIMUM
REQUIREMENTS OF THE FIRE PREVENTION CODE 2020.
G.C. SHALL ENSURE EMERGENCY LIGHTS MEET OR EXCEED MINIMUM ILLUMINATION
REQUIREMENTS PER FBC 2017 & FLORIDA FIRE PREVENTION CODE 2020.
EMERGENCY ILLUMINATION SHALL BE PROVIDED. (7.9.1.1) (13.2.9)
THE FLOORS AND OTHER WALKING SURFACES WITHIN AN EXIT AND WITHIN THE PORTIONS
OF THE EXIT ACCESS AND EXIT DISCHARGE DESIGNATED IN 7.8.1.1 SHALL BE ILLUMINATED
AS FOLLOWS: (2) THE MINIMUM ILLUMINATION FOR FLOORS AND WALKING SURFACES,
OTHER THAN NEW STAIRS DURING CONDITIONS OF STAIR USE, SHALL BE TO VALUES OF AT
LEAST 1 FT -CANDLE (10.8 LUX), MEASURED AT THE FLOOR. (3) IN ASSEMBLY
OCCUPANCIES, THE ILLUMINATION OF THE WALKING SURFACES OF EXIT ACCESS SHALL
BE AT LEAST 0.2 FT -CANDLE (2.2 LUX) DURING PERIODS OF PERFORMANCES OR
PROJECTIONS INVOLVING DIRECT LIGHT.
TACTILE EXIT SIGNAGE MOUNTED AT 60" A.F.F. LATCH SIDE OF THE DOOR.
BUILDING ADDRESS NUMBERS SHALL BE PLACED ON IN A VISIBLE LOCATION ON THE
PRIMARY FACADE. LETTERS SHALL BE A MINIMUM OF 6" IN HEIGHT AND SHALL CONTRAST
WITH THE WALL FINISH WHERE THEY ARE AFFIXED.
ALL CONSTRUCTION, DEMOLITION AND RENOVATION SHALL COMPLY WITH REQUIREMENTS
OF NFPA 241: STANDARDS FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND
DEMOLITION OPERATIONS, 2020 EDITION.
A KNOX-BOX SHALL BE MOUNTED TO EXTERIOR WALL ADJACENT TO FRONT ENTRY DOORS
- COORDINATE TYPE AND FINISH WITH OWNER AND ARCHITECT PRIOR TO PURCHASE AND
INSTALLATION. COORDINATE MOUNTING WITH MANUFACTURER SPECIFICATIONS.
ALL INTERIOR WALL & CEILING FINISHES TO BE CLASS "C" FINISH MATERIALS AND SHALL
MEET MINIMUM APPLICABLE REQUIREMENTS OF THE 2020 FLORIDA BUILDING CODE;
SECTION 803 & TABLE 803.9.
Digitally signed by
Brent Brent Wood
DN: cn=Brent Wood,
o=Brent A. Wood
Architecture, LLC, ou,
WOO il emam, c=ent@bawooda
rchil=b
Date: 2021.03.30
08:50:44-04'00'
Z
O
U
C/)
Z
O
O
LL_
W
C/)
J
am
ZD
U)
W
r
CV
CV
L
4i
a0
❑
N
N
o
z
W
�
c
O
U
oz
o
(%j
N
M
.4
�
rD
W
00 Al
gL
D r�
Q ��
Q X
Z > wi
❑ m
o
Q U N
O N
r-
w cor'
it
m N F
ti
m
w M
>Q
�❑
❑re,
z
0
U -
OU
=a
�w
0 coOZ
cow
coU)
w
LO
LO
w�
> M
ZE Q
❑ 0
z
O
U�
OV
=Q
�w
�m
OZ
�w
�U)
CDw
A,
L
w
>o
N N >
w
TZ
a
U)
E2,5
z ui m
z /1
z
Z
a)yr
a)
�oN
o
2 p N
cLn
a` d O