HomeMy WebLinkAboutProduct Approval (2) n.:
NEMO 1.0c.
Certificate of Authorization#32455
353 Christian Street,Unit#13
pxford;CT 06478-
(203)262-9245
ENGINEER . - EVALUATE TEST CONSULT
REPORTEVALUATION
Boral Roofing Evaluation Report M35710.12.10-R15 "
7575 Irvine.Center Drive,Suite 100 FL14317-1112
Irvine,CA.92618 'Date of Issuance:12/21/2010
(602)269-2288 Revision 15:03/05/2021
SCOPE:
This Evaluation Report is issued under Rule,611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 71h Edition(2020)Florida Building Code sections noted herein.:-
DESCRIPTION: Boral Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance'Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report.is valid until such time as the named product(s)changes;the referenced
Quality Assurance or production facility location(s) changes, or Code provisions,that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the-product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC.requires a
complete review,of its;Evaluation-Report relative to updated Code requirements-with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the wods "NEIVIOIetc. Evaluated" may be
displayed in advertising literature. If.any portion of the'Evaluation Reportt is displayed, then it shall be done in its
_entirety.
INSPECTION: Upon request;a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the'request of the Building Official.
This Evaluation Report consists of,pages 1,thr6ugh 6.
Prepared by: ,,,p�a�ln,.,y,,�_
Vic?
Robert J.M.Nieminerr P.E. fi •,,oa+.?•��' Thefa'csimileseala� ',,tiPs�_••,,,;�s:,• appearing was authorized by Robert
'h"emu°�:• Nieminen;P.E.,on 03/05/2021.This does not serve as an
Florida Registration No.59166,Florida DC4ANE1983 � "_.���..,,:,,,�•�
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have;nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2.' NEMO ETC,LLC is not owned,,operated or controlled by any company.manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing'or distributing products for
which the evaluation reports are'being issued.
4. Robert Nieminen;P.E.does not have,nog will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEW ETC,LLC nor Robert Nieminen,P.E.are,in anyway,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting:or.design guidance unless retained
specifically for that purpose.
.@2018,NEMO ETC,LLC
r
O IVEnno�etc.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated
compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/Conditions of Use set forth herein.
STANDARDS:2.
Seetion _._�._..._ Property Standard _ YearT__.
1504.3.1 Wind resistance UL 1897 2015
1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015
R905.1.1,R905.2.8.2
1507.3.3/11905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
TAS 110 Material standard TAS 103 2020
3. REFERENCES:
Entit Examination Reference Date
ERD(TST 6049) ASTM D1970/D4798 M36790.07.11 09/30/2011
ERD(TST 6049) ASTM D226,D1970 B40380.08.12 08/28/2012
ERD(TST 6049) TAS 103-20(tensile adhesion) C41420.09.12-2 09/11/2012
ERD(TST 6049) ASTM D1970(adhesion) B41940.09.12 09/13/2012
ERD(TST 6049) TAS 103-20(tensile adhesion) B47390.07.14-1 07/31/2014
ERD(TST 6049) TAS 103-20(tensile adhesion) B47390.09.14 09/04/2014
OC(PDM1838) Physical Properties Equivalency statement 11/02/2017
PRI(TST 5878) ASTM D19.70 NEI-031-02-02:REV 10/27/2010
PRI(TST 5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010
PRI(TST 5878) Wind Uplift BORR-001-02-01 03/17/2015
PRI(TST 5878) Wind Uplift BORR-005-02-01 06/24/2015
PRI(TST 5878) TAS 103-20(tensile adhesion) DAPF-002-02-01 03/08/2018
PRI(TST 5878) ASTM D1970 OCF-356-02-01 03/23/2018
PRI(TST 5878) FRSA/TRI 09-2018 OCF-356-02-02 03/22/2018
PRI(TST 5878) TAS 103-20(tensile adhesion) OCF-356-02-04 03/72/2018
PRI(TST 5878) ASTM D1970(adhesion) OCF-443-02-01 10/11/2018
PRI(TST 5878) TAS 103-20(tile slippage clarification) OCF-356-02-02.1 02/03/2021
PRI CMT(QUA9110) Quality Assurance Declaration from Supplier 03/05/2021
4. PRODUCT DESCRIPTION:
Product ;Material Standard. Plant(s). Description
4.1 Boral®TileSeal 50HT ASTM D1970 Brentwood, nominal 50-mil thick,polyester-surfaced,self-adhering SBS
NH modified bitumen roof underlayment
4.2 Boral®TileSealHT ASTM D1970 and Brentwood, nominal 60-mil thick,polyester-surfaced,self-adhering SBS
FRSA/TRI 09-18 NH modified bitumen roof underlayment
4.3 Boral®MetalSealHT ASTM D1970 and Brentwood, nominal 60-mil thick,polyester-surfaced,self-adhering SBS
FRSA/TRI 09-18 NH modified bitumen roof underlayment
4.4 GatorSeal® ASTM D1970 Brentwood, nominal 55-mil thick,granule-surfaced,fiberglass reinforced,
NH self-adhering SBS modified bitumen roof underlayment
4.5 Citadel®Plus ASTM D1970 Brentwood, nominal 48-mil thick,fabric-surfaced,fiberglass reinforced,
NH self-adhering SBS modified bitumen roofing underlayment
for use as a base-layer in multi-ply underlayment systems
NEMO ETC,LLC Evaluation Report M35710.12.30-R15
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-1112
Boral Roof Underlayments;(602)269-2288 Revision 15:03/05/2021
Page 2 of 6
i�
NEnno etc.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEIVIO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance-unless retained specifically for that purpose.
5.2 This Evaluation Report_ is,not for use in FBC High Velocity Hurricane Zone jurisdictions (Le.,' Broward'and Miami=
Dade Counties).
5.3 This Evaluation Report pertains,to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements'to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification.-.Refer to FBC 1505 for requirements and,
limitations regarding roof assembly'fire classification. Refer to FBC 2603 for requirements and limitations
concerning,the use of foam.plastic insulation.
5.5 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the•prepared roof covering.
5.6 Allowable Roof Covers: Table 1 pertains to use of'each listed underlayment by-itself'beneath the stated roof ,
covers. Refer to the installation instructions for multi-ply underlayment options.-
TABLE 1: ROOF COVER OPTIONS
FBCSection: 1507.2 1507.3 1507.4&1507.5 1507.7 1507.8&ISOZ9
Asphalt Clay and Concrete Tile Metal Slate or Wood
Underlayment Mechanical Adhesive- Slate-Type
Shingles Attach Set Panels Shingles Shingles Shingles&Shakes
Boral TileSeal 50HT Yes No No Yes Yes Yes Yes
gointstrips,1507.1.1.3/R905.1.1.3)
Boral TileSealHT Yes Yes Yes Yes Yes Yes Yes
(See 5.6.1) (joint strips,150ZI.1.3/005.1.1.3)
Boral MetalSealHT Yes Yes Yes Yes Yes Yes . Yes
(See 5.6.1) Uointstrips,15OZ1.1.3/R905.1.1.3)
GatorSeal Yes No No No No Yes Yes
Gointstrips,1507.1.1.3/R905.1.1.3)
5.6.1 Adhesive-set is-limited to use of following underlayment/tile-adhesive combinations.
TABLE IA:ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS'
Underlayment Adhesive Florida Product
Approval
Boral TileSealHT or Boral MetalSealHT DAP Foam"Touch'n Seal StormBond Roof Tile Adhesive" FL14506
Boral TileSealHT or Boral MetalSealHT DAP Foam"Touch'n Seal StormBond 2 Two-Component FL21374
Polyurethane Roof Tile Adhesive"
Boral TileSealHT or Boral MetalSealHT - Dupont`Tile Bond''Roof Tile Adhesive.. FL22525
Boral TileSealHT or Boral MetalSealHT ICP Adhesives and Sealants"Polyset®AH7160" FL6332
Boral TileSealHT or Boral MetalSealHT' ICP Adhesives and Sealants"Polyset®RTA-1" FL6276
'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report M35710.12.10-R3S
Certificate of Authorization#32455 7-EDITION.(2020)FBC NON-HVHZ EVALUATION FL14317-R12
Boral Roof Underlayments;(602)269-2288 Revision 15:03/05/2021
Page 3 of 6
MEMO etc.
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED.UNDERLAYMENTS
Underlayment Application Primer Substrates"
(Optional)ASTM D41 plywood
TileSeal
Citadel HT,Boralral MetalSealus, TileSeal H or GatorSeal OHT,Boral self-adhering none ASTM D226 Type II felt or Citadel Plus
ASTM D41 metal(flashing metal,valley metal,etc.)
Boral TileSealHT,Boral MetalSealHT self-adhering I (Optional)ASTM D41 OSB
Boral TileSealHT self-adhering (Optional)ASTM D41 Huber"Zip Deck"
None G-P Gypsum"DensDeck Prime"
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but not less than Section 5.8.3 herein.
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-120.0 post:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional)ASTM D41 to the plywood deck
Base Ply: Citadel Plus,self-adhered
Cap Ply: Boral TileSealHT or Boral MetalSealHT,self-adhered, and back-nailed within the selvedge-edge side
laps using 12 ga.x 1'/0"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#2 Maximum Design Pressure=-142.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply: None
Cap Ply: Boral TileSealHT or Boral MetalSealHT, self-adhered and back-nailed within the selvedge-edge side
laps using 12 ga.x 1Y4"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure=-202.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Tropical Roofing Products#410 Quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply: None
Cap Ply: Boral TileSealHT or Boral MetalSealHT,self-adhered,and back-nailed within the selvedge-edge side
laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
NEMO ETC,LLC Evaluation Report M35710.12.10-R15
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-R12
Boral Roof Underlayments;(602)269-2288 Revision 15:03/05/2021
Page 4 of 6
NEMO etc.
#4 Maximum Design Pressure=-210.0 psf:
Deck:_ Min. 15/32-inch plywood to meet project requirements .to satisfaction of Authority Having
Jurisdiction.
Primer: KARNAK#89 Sta-Tak Primer to the plywood deck
Base Ply: None
Cap Ply: Boral TileSealHT or Boral MetalSeal"T,self-adhered,and back-nailed within the selvedge-edge side
laps using 12 ga.x 1Y4"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure=-120.0 psf:
Deck: Min.2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: ASTM D41 to the concrete deck
Base Ply: (Optional)Citadel Plus,self-adhered
Cap Ply: Boral TileSealHT or Boral MetalSealHT,self-adhered
#6 All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of-45 psf.
.5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Maximum
Underlayment Prepared Roof Cover Installation Type Exposure
(days)
GatorSeal Mechanically attached 30
Boral TileSeal 50HT Mechanically attached 180
Boral TileSealHT or Boral MetalSealHT Adhesive-set tile roof system 180
Mechanically attached 180
Citadel Plus(base ply in multi-ply underlayment systems only) NSA 180
(prior to placement of subsequent underlayment)
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck the roof assemblies,the
maximum roof slope shall.be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment* Tile Profile Staging Method Maximum Slope
Boral TileSealHT or Boral MetalSealHT Flat or Lugged Max.10-tile stack 6:12
INSTALLATION:6.
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing_ published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Boral TileSeal 50HT or GatorSeal:
6.3.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the,manufacturer's installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt,the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
NEMO ETC,LLC Evaluation Report M35710.12.10-R35
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-R12
Boral Roof Underlayments;(602)269-2288 Revision 15:03/05/2021
Page 5 of 6
r•
NEMO etc.
6.3.2 Multi-Ply Underlayment Systems:
One or two plies of Citadel Plus followed by Boral TileSeal SO"T or GatorSeal is allowable for use under
mechanically attached, non-tile prepared roof systems. Limits of use are those associated with the top-layer
material. This is not a requirement,but is allowable if a multi-ply underlayment system is desired.
6.4 Boral TileSeal"T or Boral MetalSeall:
6.4.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached,FBC Approved ASTM D226 Type II felt,'the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.4.2 Tile Applications:
Shall be installed in compliance with requirements for a Self-Adhered Membrane in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation
instructions.
Refer to Section 5.8.2 for attachment limitations.
Refer to Table 4 for tile staging limitations.
6.4.3 Multi-Ply Underlavment Systems:
One or two plies of Citadel Plus followed by Boral TileSeall or Boral MetalSeall is allowable for use under
mechanically attached, non-tile prepared roof systems. Limits of use are those associated with the top-layer
material: This is not a requirement,but is allowable if a multi-ply underlayment system is desired.
Refer to Section 5.8.2 for use of Citadel Plus as a base ply membrane in underlayment systems for use under tile-
roof systems.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
1. 8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALITY9.
PRI Construction Materials Technologies,LLC(QUA9110);(813)621-5777;bwilson@pricmt.com
-END OF EVALUATION REPORT-
NEW ETC,LLC Evaluation Report M35710.12.30-R15
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-1112
Boral Roof Underlayments;(602)269-2288 Revision 15:03/05/2021
Page 6 of 6