HomeMy WebLinkAboutProduct Approval (4) NEnno etc. TABLE 1E: ... . .. ..RECOVER BONDEDSYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, ROOF System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) _ MDP No. (Note 1)• (Note 13) Type Fasten(Note 11) Attach Base Ply Ply Cap Ply (Psf) APA rated, Min.1.5-inch ACFoam II,ACFoam III, 19/32 CAT, EnergyGuard Polyiso Insulation, 0.578 in., (Optional)One or ENRGY 3,ENRGY 3 CGF,H-Shield,H- Trufast Versa Fasteners min.X" & Exposure 1 more layers,.any ( penetration) 1 per (Optional)SBS- SBS-SA,APP- Shield CG,ISO 95+GL,Multi-Max Plates;2 screws per plate installed 180'into the Z SBS-SA SA,SBS-TA, SA,SBS-TA, -67.5* W 59 OSB or min. combination,loose FA3,Polytherm or Ultra-Max holes of the plate* 1.3 ft APP TA APP-TA 19/32"APA laid rated optionally primed with POLYBRITE plywood 745 or WB3000 Note: For re-roof or recover construction,field withdrawal resistance testing(Note 11)shall yield minimum 180lbf. Additional Versa-Fast Fasteners within each Verso-Fast Plate maybe utilized to produce minimum withdrawal resistance Min.1.5-inch ACFoam II,ACFoam III, Dekfast Hex(aka,Dekfast PLT-H-2-7/8)or Dekfast EnergyGuard Polyiso Insulation, (Optional)One or Galvalume Steel 3"Round Insulation Plate(aka, (Optional)SBS- SBS-SA,APP- Min.19/32- 'ENRGY 3,ENRGY 3 CGF,H-Shield,H- more layers,any Dekfast PLT-R-3)with Dekfast#12,OMG 3 in. 1 per W-60 inch Shield CG,ISO 95+GL,Multi-Max SBS-SA SA,SBS-TA, SA,SBS-TA, -67.5* combination,loose FA3,Polytherm or Ultra-Max Galvalume Plate(non-ribbed)or OMG AccuTrac 1.3 ftZ plywood Yt APP-TA APP-TA laid Plate with#12 Roofgrip or Trufast 3"Metal optionally primed with POLYBRITE 745 or WB3000 Insulation Plate with Trufast DP HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: Min.15/32- (Optional)One or Dekfast#14 with Dekfast Hex(aka,Dekfast PLT-H- more layers,any Min.1.5-inch Polytherm,ACFoam II, 2-7/8),OMG#14 HD with OMG 3"Galvalume 1 per (Optional)APP- W-61 inch combination,loose H-Shield or Polytherm Steel Plates or Trufast#14 HD with Trufast 3-inch 2.7 ftz APP-SA-H TA APP-TA 30.0 plywood laid Insulation Plates (Optional)One or Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Min.15/32- Min.0.25-inch DensDeck Prime or Dekfast#14,OMG 3"Round Metal Plate with more layers,any 1 per (Optional)APP- W-62 inch combination,loose SECUROCK Gypsum-Fiber Roof OMG HD,OMG Flat Bottom Plate(Accutrac)with 2.0 ftZ APP-SA-H TA APP-TA -30.0 plywood laid Board Roofgrip#14 or Trufast 3"Metal Insulation Plate with Trufast#14 HD. Min.15/32- (Optional)One or Min.0.25-inch DensDeck Prime or Dekfast#14 with Dekfast Hex(aka,Dekfast PLT-H- W-63 inch more layers;any SECU ROCK Gypsum-Fiber Roof 2-7/8),OMG#14 HD with OMG 3"Galvalume 1 per APP-SA-H (Optional)APP- APP-TA -45.0 plywood combination,loose Board Steel Plates or Trufast#14 HD with Trufast 3-inch 1.8 ftZ TA laid Insulation'Plates HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: Min.15/32- (Optional)One or Dekfast#14 with Dekfast Hex(aka,Dekfast PLT-H- W-64 inch more layers,any Min.1.5-inch Polytherm,ACFoam II, 2-7/8),OMG#14 HD with OMG 3"Galvalume 1 per SBS-SA-H (Optional)SBS- SBS-TA -30.0 plywood combination,loose H-Shield or Polytherm H Steel Plates or Trufast#14 HD with Trufast 3-inch 2.7 ftZ TA laid Insulation Plates NEMO ETC,LLC Evaluation Report P9290.02.08-R25 for FL1654-R27 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:09/30/2020 ©2018 NEMO ETC,LLC Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 17 of 94 r �y . ` NEnno�etc. TABLE 11: .., DECKS SYSTEM TYPE F:NON-INSULATED,BONDED ROOF System Deck(Note 1) Primer Roof Cover(Note 15) MDP(psf) No. Joint Treatment Base Ply Ply Cap Ply SELF-ADHERING BASE PLY: APA rated, Elastoflex SA V Plus 7/16 CAT, None OSB joints are covered with 4-inch wide strips of Elastoflex SA V,rolled into or Elastoflex SA V (Optional)SBS-SA,SBS- SBS-SA,APP-SA, -52.5 W-208 0.418 in., place to create continuous bond. TA,APP-TA SBS-TA,APP-TA Exposure 1 OSB Plus FR W 209 Min.15/32- None None SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA, -90.0 inch plywood TA,APP-TA SBS-TA,APP-TA W-210 Min.15/32- pG100 None SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA, -97.5 inch plywood TA,APP-TA SBS-TA,APP-TA Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled Elastoflex SA V or (Optional)SBS-SA,SBS- SBS-SA,APP-SA, W-211 inch plywood (Optional)PG100 into place to create continuous bond. Elastoflex SA V FR TA,APP-TA SBS-TA,APP-TA 97.5 W 212 Min.15/32- POLYBRITE 745 None SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA, -105.0 inch plywood or WB3000 TA,APP-TA SBS-TA,APP-TA Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled Elastoflex SA V Plus (Optional)SBS-SA,SBS- SBS-SA,APP-SA, W-213 inch plywood (Optional)PG100 into place to create continuous bond. or Elastoflex SA V TA,APP-TA SBS-TA,APP-TA -135.0 Plus FR HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: W-214 Min.15/32- (Optional)PG100 None APP-SA-H (Optional)APP-TA APP-TA -90.0 inch plywood W-215 Min.15/32- (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled APP-SA-H (Optional)APP-TA APP-TA -135.0 inch plywood into place to create continuous bond. HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: W-216 Min.15/32- None None SBS-SA-H (Optional)SBS-TA SBS-TA -90.0 inch plywood W 217 Min.15/32- PG100 None SBS-SA-H (Optional)SBS-TA SBS-TA -97.5 inch plywood W 218 Min.15/32- (Optional)PG300 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled SBS-SA-H (Optional)SBS-TA SBS-TA -97.5 inch plywood into place to create continuous bond. W 219 Min.15/32- POLYBRITE 745 None SBS-SA-H (Optional)SBS-TA SBS-TA 105.0 inch plywood or WB3000 - NEMO ETC,LLC Evaluation Report P9290.02.08-1125 for F11654-1127 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:09/30/2020 ©2018 NEMO ETC,LLC Polyglass Modified Bitumen Roof Systems,(954)233-1330 Appendix 1,Page 37 of 94 a r , i - NEMO etc. MEMBRANE/ADHESIVE COMBINATIONS REFERENCE LAYER • MATERIAL APPLICATION SBS-SA-H Base-Ply Elastobase SA Self-adhering (followed (SBS,Self-Adhering,Hybrid systems) - - by torch-applied sheet). Base Ply One or more plies Elastoflex SA V,Elastoflex SA V FR,Elastoflex SA V Plus,Elastoflex SA V Plus FR,Elastoflex SA Base HD SBS-SA Cap Ply Elastoflex SA P,Elastoflex SA P FR,Polyreflect Self-Adhering (SBS,Self-Adhering) Note: Unless otherwise noted,permissible membrane substrates forSBS-SA are limited to the SBS-SA Base Ply options herein, Elastobase(poly/sand)or Elastobase(poly/poly). APP-CA3 Cap Ply Polyflex G FR PG350 at 1.5-2.0 gal/square APP-TA Base Ply or Ply One or more plies Polyglass Base,Polyflex,Polybond (APP,Torch-Applied) Cap Ply Polyflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FR Torch-Applied APP-SA-H Base Ply Polyflex SA Base Self-adhering(followed (APP,Self-Adhering,Hybrid Systems) by torch-applied sheet) APP-SA Cap Ply Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polyfresko G SA FR,Polykool (APP,Self-Adhering) Note: Unless otherwise noted,permissible membrane substrates forAPP-SA are limited to the SBS-SA Base Ply options herein; Self-Adhering. Elastobase(poly/sand)or Elastobase(poly/poly). 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MOP limitations. The lesser of the MDP listings below vs.those in Table 3A applies. VAPOR BARRIER,OPTIONS;STRUCTURAL CONCRETE DECK;FOLLOWED BY ADHESIVE-APPLIED INSULATION PER TABLE 3A: OPTION VAPOR BARRIER MDP #• PRIMER TYPE(NOTE 15) APPLICATION INSULATION ADHESIVE (PSF) C-VB-1. PG100 Elastoflex SA V Plus Self-Adhering D-IS or CR-20,12-inch o.c. -60.0 C-VB-2. PG100 Polyglass Base Torch-applied D-IS or CR-20,12-inch o.c. -75.0 C-VB-3. PG100 Elastoflex SA P Self-Adhering D-IS,12-inch o.c. -75.0 C-VB-4. I PG100 Elastoflex SA P Self-Adhering M-OSFA,12-inch o.c. -157.5 C-VB-S. PG100 Elastoflex SA P Self-Adhering CR-20,12-inch o.c. -270.0 C-VB-6. PG100 Elastoflex SA V,Elastoflex SA V`FR,Elastoflex SA V Plus,Elastoflex SA V Plus FR Self-Adhering M-OSFA,M-PG-1,OB500 or CR=20,12-inch o.c. -290.0 C-VB-7. PG100 SBS-TA(with sanded-top-surface) Torch-applied. M-OSFA,M-PG-1,OBS00 or CR-20,12-inch o.c. -290.0 17 The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings for application limitations and a Roofing Materials Directory for fire ratings associated with coating usage. SURFACING OPTIONS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS OPTION#_ SURFACING FLORIDA PRODUCT APPROVAL SURF-1. PG 300 FL10291 SURF-2. PG 600 FL10291 SURF-3. PG 650 FL10291 SURF-4. PG 700 FL10291 SURF-S. PG 700 QS FL10291 SURF-6. PG 800 FL10291 SURF-7. Polyplus 60 FL10291 NEMO ETC,LLC Evaluation Report P9290.02.08-R25 for FL1654-R27 Certificate of Authorization N32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:09/30/2020 ©2018 NEMO ETC,LLC Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 4 of 94 i Y o� 2 O.' NEMOletc. ANSI/SPRI WD3,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk"carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question,field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1,C-2,D-1 or D-2,the insulation is optional. Alternatively,an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation(Note 5 herein). The separator component shall be documented as meeting FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete(LWIC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted,for systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent'LWIC references,listings were established through testing over lightweight concrete cast using only foaming agent(ASTM C896),water and Portland cement(ASTM C150),with no proprietary additives,in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof(tear-off)applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15 For bonded membrane applications,unless otherwise noted,refer to the following. MEMBRANE/ADHESIVE COMBINATIONS REFERENCE' LAYER MATERIAL APPLICATION BP-AA Base Ply One or more plies Polyglass G2 Base,FBC Approved ASTM D4601,Type II (Base and Ply sheets, Ply One or more plies Polyglass Ply IV,Polyglass Ply VI,FBC Approved ASTM D2178,Type IV or VI Hot Asphalt at 20-40 Ibs/square Asphalt-Applied) Note: Asphalt-applied sheets or insulation shall not be applied to poly film surfaced membranes. Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 HP,Elastoshield HT PG350 at 1.5-2.0 SBS-CA1 Cap Ply Elastoshield HT G,Elastoshield HT G FR,Elastoflex V G,Elastoflex V G FR,Elastoflex S6,Elastoflex S6 HP,Elastoflex S6 G,Elastoflex gal/square S6 G FR,Elastoshield TS G,Elastoshield TS G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 HP Polyplus 35 at 1.5-2.0 SBS-CA2 Cap Ply Elastoshield HT G,Elastoshield HT G FR,Elastoflex V G,Elastoflex V G FR,Elastoflex S6,Elastoflex S6 HP,Elastoflex S6 G,Elastoflex gal/square S6 G FR,Elastoshield TS G,Elastoshield TS G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) Base Ply or Ply One or more plies Elastobase(sand/sand or poly/sand),Elastobase P(sand/sand or poly/sand),Elastoflex V,Elastoflex S6,Elastoflex 56 HP,Elastoshield HT SBS-AA Elastoshield HT G,Elastoshield HT G FR,Elastoflex V,Elastoflex V G,Elastoflex V G FR,Elastoflex S6,Elastoflex S6 HP,Elastoflex S6 G, Hot Asphalt at 20-40 (SBS,Asphalt-Applied) Cap Ply Ibs/square Elastoflex S6 G FR,Elastoshield TS G,Elastoshield TS G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) Note: Asphalt-applied sheets or insulation shall not be applied to poly film surfaced membranes. Base Ply or Ply One or more plies Elastobase(sand/poly),Elastobase(poly/poly),Elastoflex V,Elastoflex S6,Elastoflex S6 HP,Elastoshield HT SBS-TA Elastoshield HT G,Elastoshield HT G FR,Elastoflex V,Elastoflex V G,Elastoflex V G FR,Elastoflex S6,Elastoflex S6 HP,Elastoflex S6 Torch-Applied (SBS,Torch-Applied) Cap Ply G,Elastoflex S6 G FR,Elastoshield TS G,Elastoshield TS G FR,Polyfresko G SBS(poly-film backed),Polyfresko G SBS FR(poly-film backed) NEMO ETC,LLC Evaluation Report P9290.02.08-R25 for FL1654-1127 Certificate of Authorization#32455 7TM EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:09/30/2020 ©2018 NEMO ETC,LLC Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 3 of 94 ONEMOjetc' e The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 'Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Minimum 1-inch plywood penetration or wood plank embedment. ➢ Steel Deck: Minimum 0.75-inch steel penetration and engage the top,flute of the steel deck. ➢ Structural Concrete: Minimum 1-inch embedment into pilot hole in-accordance with published installation instructions. 3 Unless otherwise noted,insulation may be any one layer or combination of FBC Approved(_Local or Statewide)board(s)that meet FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof . cover. 4 Minimum 200 psi,minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for.rigid insulation board for System Types B-1,C-1,C-2,D-1 or D-2,whereby fasteners are installed . through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type,thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues,such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(February 2020). 6 Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt(HA): Full coverage at 25-30 Ibs/square. ➢ DuPont INSTA STIK Quik Set Insulation Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. ➢ H.B.Fuller Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5=inch wide ribbons,12-inch o.c. ➢ H.B.Fuller Millennium PG-1 Pump Grade Adhesive(M-PGI): Continuous 0.25 to 0.5-inch-wide ribbons,12-inch o:c. ➢ OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wideYibbons,12-inch o.c. Note: OlyBond Green maybe used where OlyBond 5OO is referenced. ➢ OlyBond Classic(OB Classic): Full coverage at 1 gal/square. ➢ ICP Adhesive'&'Sealants Polyset CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c. ➢ Note:When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7 Unless otherwise noted,:all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocya n u rate at the following thickness limitations may be substituted with the following ,Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. ➢ H.B.Fuller Millennium One Step Foamable Adhesive(M-OSFA): MDP= 7157.5 psf (Min.0.5-inch thick) ➢ H.B.Fuller Millennium PG-1 Pump Grade Adhesive(M-PG3): MDP= -157:5 psf (Min.0.5-inch thick) ➢ OMG OlyBond 500(OB500): MDP= -45.0 psf (Min.0.5-inch thick Multi-Max FA-3) ➢ OMG OlyBond 500(OB500): MDP= -187.5 psf (Min.0.5-inch thick ISO 95+GL) ➢ OMG OlyBond 500(OB500): MDP= -315.0 psf (Min.0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500(OB500): MDP= -487.5 psf (Min.0.54nch thick ACFoam II) ➢ ICP Adhesives&Sealants Polyset CR-20: MDP= -117.5 psf (Min.1.0-inch thick). 8 For adhered roof insulation and"board-size:'Unless otherwise noted,referto Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29(February 2020). 9, For mechanically attached components or partially-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed at least-the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure.criteria. Commonly used methods are NEMO ETC,LLC Evaluation Report P9290.02.08-R25 for FL1654-1127 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:09/30/2020 ©2018 NEMO ETC,LLC Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 2 of 94 MEMO etc. "APPEND"IX 1:ATTAC'HmENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE IA Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 5 1B Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 6-12 1C Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 12-14 SD Wood New,Reroof(Tear-Off)or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 14-15 lE Wood New,Reroof(Tear-Off)or Recover C-1 Mech.Attached Insulation,Bonded Roof Cover 15-19 1F Wood New,Reroof(Tear-Off)or Recover D-2 Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 19-23 1G Wood New or Reroof(Tear-Off) E-2 Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 23-29 1H Wood New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 29-36 11 Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 37 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 38-43 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-1 Mech.Attached Insulation,Bonded Roof Cover 44-50 2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-2 Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 51-53 2D Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-2 Insulated,Mech.Attached Velociflex,Bonded Roof Cover 53-55 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 56-68 3B Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 68 4A Lightweight concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 69-73 4B Lightweight concrete New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 73-47 4C Lightweight concrete New or Reroof(Tear-Off) E-2 Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 74-78 5A Cementitious wood fiber Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 79-80 5B Cementitious wood fiber Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 80-82 5C Cementitious wood fiber Reroof(Tear-Off)or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 82 51) Cementitious wood fiber Reroof(Tear-Off)or Recover C-1 Mech.Attached Insulation,Bonded Roof Cover 83 SE Cementitious wood fiber Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 83 6A Existing gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 84-88 6B Existing gypsum Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 88 6C Existing gypsum Reroof(Tear-Off)or Recover C-1 Mech.Attached Insulation,Bonded Roof Cover 88 6D Existing gypsum Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 88 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 89-94 7B Various Recover F Non-Insulated,Bonded Roof Cover 94 NEMO ETC,LLC Evaluation Report P9290.02.08-1125 for FL1654-1127 Certificate of Authorization#32455 7'"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:09/30/2020 ©2018 NEMO ETC,LLC Polyglass Modified Bitumen Roof Systems,(954)233-1330 Appendix 1,Page 1 of 94 i