County, Town, Municipality, Jurisdiction
Header Information
Contractor Florida Breeze
Mechanical License # CAC1814113
Building Plan # HAYDEN
Home Address (Street or Lot#, Block, Subdivision)
Design Conditions
Winter Design Conditions
Outdoor temperature 42
Indoor temperature 70
Total heat loss 39811
Summer Design Conditions
Outdoor temperature 90
OF
OF
Btu/h
OF
REQUIRED ATTACHMENTS'
Form
RIPER 1.01
8 Mar 10
ATTACHED
Manual A Form (and supporting worksheets):
Yes ❑X
No ❑
or MAAE Form' (and supporting worksheets):
Yes ❑
No ❑X
OEM performance data (heating, cooling, blower):
Yes ❑X
No ❑
Manual D Friction Rate Worksheet:
Yes ❑
No ❑X
Duct distribution system sketch:
Yes ❑
No ❑X
Building Construction Information
Building
Orientation (Front door faces) South
North, East, West, South, Northeast, Northwest, Southeast, Southwest
Number of bedrooms 5
Conditioned floor area
Number of occupants
2605 Sq Ft
6
Indoor temperature
75
of Windows
Roof
Grains difference 61
o Gr @ 50 % Rh Eave overhang depth
3.6 Ft
Sensible heat gain
34193
Btu/h Internal shade
<—
Eave
Latent heat gain
9046
Btu/h Blinds, drapes, etc
Depth
Window
Total heat gain
43239
Btu/h Number of skylights
0
EQUIPMENTHVAC
•
41
Heating Equipment Data
Cooling Equipment Data
Blower Data
Equipment type
Heat pump
Equipment type Heat pump
Heating CFM 1255 CFM
Furnace, Heat pump, Boiler, etc.
Air Conditioner, Heat pump, etc
Model
R4H448(A,G)KP*
Model R4H448(A,G)KP*
Cooling CFM 1636 CFM
Heating output capacity
45000 Btu/h Sensible cooling capacity 37340 Btu/h
Heal pumps- capacity at winter design outdoor conditions
Latent cooling capacity 9771 Btu/h
Auxiliary heat output capacity
Btu/h Total cooling capacity 47111 Btu/h
HVAC DUCT DISTRIBUTION
SYSTEM
DESIGN (IRC M1601.1)
Design airflow
1785 CFM
Longest supply duct: 80 Ft Duct Materials Used (circle)
Trunk Duct: Duct board Flex, Sheet metal,
External Static Pressure (ESP)
0.71 IWC
Longest return duct: 30 Ft
Lined sheet metal, Other (specify)
Component Pressure Losses (CPL) 0.25 IWC Total Effective Length (TEL) 11 0 Ft Branch Duct Duct board, lex Sheet metal,
Available Static Pressure (ASP) 0,46 IWC Friction Rate: 0,42 IWC Lined sheet metal, Other (specify)
Friction Rate = (ASP =100) � TEL
ASP = ESP - CPL
Contractor's Printed Name , Kristin Kelly Date
Contractor's Signature
' The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions.
' If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions.
Farm generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program.
Air Conditioning Contractors of America
Manual S (Residential Equipment Selection)
Project Information Cooling Design Information
Name:1 Outdoor Design Temp: 91 °F db Summer
City: Outdoor Design Temp: 43 "F db IWinter
State: F1 Altitude: Altitude Adjustment: 1.00 Indoor Design Temp: 75 °F db 50 %RH = °F wb
I— Manual J Load Calculations
Total Load
Sensible
Latent
SHR Heat Loss
43239
34193
9046
0.791 C7
lations
r Airflow
19
ible CFM
E
F1636
e--- utM information
Manufacturer: 1COMFORTMAKER Furnace Model #: AFUE:
Coil or Fan -Coil Model #: FXM4X48"AL Condenser Model #: R4H448(A,G)KP' SEER: 14.5 HSPF: 8.20
(A) Manufacturers Cooling Performance Data
Lower Return Air
Outdoor Temperature =
95 (F db)
Entering Coil Temperature = 75 (F db)
CFM (F wb)
Total BTUH
Sensible BTUH
Latent BTUH
SHR
Rated CFM @ Rated RA Temperature
62
46,800
34,659
12,141
0.7406
Rated CFM @ Design RA Temperature
r 1400 63
47,034
33,283
13,751
0.7076
Rated CFM @ Rated RA Temperature
r 47,971
27,778
r 20,193
0.5791
(u) Manufacturers Cooling Performance Data
Higher Return Air
Outdoor Temperature =
95 (F db)
Entering Coil Temperature = 75 (F db)
CFM (F wb)
Total BTUH
Sensible BTUH
Latent BTUH
SHR
Rated CFM @ Rated RA Temperature
62
46,717
39,717
7,000
0.8502
Rated CFM @ Design RA Temperature
1800 63
47,164
38,930F
8,235
0.8254
Rated CFM @ Rated RA Temperature
67
48,953
35,780
13,173
0.7309
w1011U901AU r a a.uunny rvriwmance iiala (Inrerpolate0)
Design Return Air Outdoor Temperature = 95 (F db)
CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR
36,615 10,496' 0.7772
Excess Latent Capacity Calculation + 725 725'
Capacity @ Design CFM / RA (F wb) F1 336 63 47,111 37,340 9,771 0.793
Equipment Capacity as a % of Design 108.95% 109.20% 108.029/6
o,— Manufacturers Heat Pump Data
Capacity
Capacity
Balance Supplemental
@ 47 -F6,28 db
@ 1�7- OF db
Point Heat Required
46,280
26,680
23.8 15.87
i
FManufacturers Furnace Data
Input Output
Desired Calculated