HomeMy WebLinkAboutPlans Examiner Review Form- 1► �CK e PiCar9vugCaiC-aindAncrf� County, Town, Municipality, Jurisdiction Header Information Contractor Florida Breeze Mechanical License # CAC1814113 Building Plan # HAYDEN Home Address (Street or Lot#, Block, Subdivision) Design Conditions Winter Design Conditions Outdoor temperature 42 Indoor temperature 70 Total heat loss 39811 Summer Design Conditions Outdoor temperature 90 OF OF Btu/h OF REQUIRED ATTACHMENTS' Form RIPER 1.01 8 Mar 10 ATTACHED Manual A Form (and supporting worksheets): Yes ❑X No ❑ or MAAE Form' (and supporting worksheets): Yes ❑ No ❑X OEM performance data (heating, cooling, blower): Yes ❑X No ❑ Manual D Friction Rate Worksheet: Yes ❑ No ❑X Duct distribution system sketch: Yes ❑ No ❑X Building Construction Information Building Orientation (Front door faces) South North, East, West, South, Northeast, Northwest, Southeast, Southwest Number of bedrooms 5 Conditioned floor area Number of occupants 2605 Sq Ft 6 Indoor temperature 75 of Windows Roof Grains difference 61 o Gr @ 50 % Rh Eave overhang depth 3.6 Ft Sensible heat gain 34193 Btu/h Internal shade <— Eave Latent heat gain 9046 Btu/h Blinds, drapes, etc Depth Window Total heat gain 43239 Btu/h Number of skylights 0 EQUIPMENTHVAC • 41 Heating Equipment Data Cooling Equipment Data Blower Data Equipment type Heat pump Equipment type Heat pump Heating CFM 1255 CFM Furnace, Heat pump, Boiler, etc. Air Conditioner, Heat pump, etc Model R4H448(A,G)KP* Model R4H448(A,G)KP* Cooling CFM 1636 CFM Heating output capacity 45000 Btu/h Sensible cooling capacity 37340 Btu/h Heal pumps- capacity at winter design outdoor conditions Latent cooling capacity 9771 Btu/h Auxiliary heat output capacity Btu/h Total cooling capacity 47111 Btu/h HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow 1785 CFM Longest supply duct: 80 Ft Duct Materials Used (circle) Trunk Duct: Duct board Flex, Sheet metal, External Static Pressure (ESP) 0.71 IWC Longest return duct: 30 Ft Lined sheet metal, Other (specify) Component Pressure Losses (CPL) 0.25 IWC Total Effective Length (TEL) 11 0 Ft Branch Duct Duct board, lex Sheet metal, Available Static Pressure (ASP) 0,46 IWC Friction Rate: 0,42 IWC Lined sheet metal, Other (specify) Friction Rate = (ASP =100) � TEL ASP = ESP - CPL Contractor's Printed Name , Kristin Kelly Date Contractor's Signature ' The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions. ' If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions. Farm generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program. Air Conditioning Contractors of America Manual S (Residential Equipment Selection) Project Information Cooling Design Information Name:1 Outdoor Design Temp: 91 °F db Summer City: Outdoor Design Temp: 43 "F db IWinter State: F1 Altitude: Altitude Adjustment: 1.00 Indoor Design Temp: 75 °F db 50 %RH = °F wb I— Manual J Load Calculations Total Load Sensible Latent SHR Heat Loss 43239 34193 9046 0.791 C7 lations r Airflow 19 ible CFM E F1636 e--- utM information Manufacturer: 1COMFORTMAKER Furnace Model #: AFUE: Coil or Fan -Coil Model #: FXM4X48"AL Condenser Model #: R4H448(A,G)KP' SEER: 14.5 HSPF: 8.20 (A) Manufacturers Cooling Performance Data Lower Return Air Outdoor Temperature = 95 (F db) Entering Coil Temperature = 75 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR Rated CFM @ Rated RA Temperature 62 46,800 34,659 12,141 0.7406 Rated CFM @ Design RA Temperature r 1400 63 47,034 33,283 13,751 0.7076 Rated CFM @ Rated RA Temperature r 47,971 27,778 r 20,193 0.5791 (u) Manufacturers Cooling Performance Data Higher Return Air Outdoor Temperature = 95 (F db) Entering Coil Temperature = 75 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR Rated CFM @ Rated RA Temperature 62 46,717 39,717 7,000 0.8502 Rated CFM @ Design RA Temperature 1800 63 47,164 38,930F 8,235 0.8254 Rated CFM @ Rated RA Temperature 67 48,953 35,780 13,173 0.7309 w1011U901AU r a a.uunny rvriwmance iiala (Inrerpolate0) Design Return Air Outdoor Temperature = 95 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR 36,615 10,496' 0.7772 Excess Latent Capacity Calculation + 725 725' Capacity @ Design CFM / RA (F wb) F1 336 63 47,111 37,340 9,771 0.793 Equipment Capacity as a % of Design 108.95% 109.20% 108.029/6 o,— Manufacturers Heat Pump Data Capacity Capacity Balance Supplemental @ 47 -F6,28 db @ 1�7- OF db Point Heat Required 46,280 26,680 23.8 15.87 i FManufacturers Furnace Data Input Output Desired Calculated