HomeMy WebLinkAboutblower doorPlanning & Development Services Building & Code Regulation Division COUNTY 2300 Virginia Ave, Rm 201 • R I• A- Fort Pierce, FL 34982 Phone, 772-462-2165 Fax: 772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method Date: 0.6 1611 �o I ( Permit #: Contractor: Job Address: Lp(l Circic Construction: (X) New Construction — Complete ( ) Existing —After Addition House Infiltration Test Results SLC Climate Zone 2 CFM (50) = 1108 Test Date: Of)l U-1 Volume = I U 4 1b ACH (50) = CFM (50) x 60 / Volume = 14,14 Mechanical Ventilation required less than 3 ACH Passing results must be & ACH (50) or less (A) Pass ( ) Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: UES, Universal Engineering Sciences Address: 607 NW Commodity Cove, PSL I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signature: PrAted Name: Sean Thacker License/Certification #: 5065970 BPI Duet Leakage Test Report Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit #: Job Information Builder: Community: Lot: Address: ao Tr, , , C I f-C le Unit: City: Fort I Gc State: FL Zip: Duct Leakage Test Results System 1 C{U cfm25 System 2 cfm25 System 3 cfm25 um of any dditional systems cfm25 Total of all systems 0 cfm25 OPrescriptive Method cfm25 (Total) To qualify as "substantially leak free" Qn must be less than or equal to 0.04 if air handler unit is installed. If air handler unit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the requirements in accordance with Section R403.3.3. �I Performance / ERI Method cfm25 (out or Total) I To qualify using this method, Qn must not be greater than the proposed duct leakage Qn specified on Form R405-2017 or R406-2017. U, 0 y U Qn Leakage Type selected on Form Qn specified on Form R405-2014 Total of all Total Conditioned systems Square Footage R405 2017 (Energy Calc) or R406-2017 (Energy Calc) or 406 2017 Fx]PASS [--]FA I L F--- Leakage to outdoors _ 10,oll(-) �— Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes. Testing Company Company Name: UES, Universal Engineering Sciences Phone: 772-924-3575 1 hereby verify that the above duct leakage testing results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: 05 /G 1 Wa I Printed Name of Tester: Sean Thacker