BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
Date: 0.6 1611 �o I ( Permit #:
Contractor:
Job Address: Lp(l Circic
Construction: (X) New Construction — Complete ( ) Existing —After Addition
House Infiltration Test Results SLC Climate Zone 2
CFM (50) = 1108 Test Date: Of)l U-1
Volume = I U 4 1b
ACH (50) = CFM (50) x 60 / Volume = 14,14 Mechanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less (A) Pass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company
Company Name: UES, Universal Engineering Sciences Address: 607 NW Commodity Cove, PSL
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature:
PrAted Name: Sean Thacker
License/Certification #: 5065970 BPI
Duet Leakage Test Report
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: Permit #:
Job Information
Builder: Community: Lot:
Address: ao Tr,
, , C I f-C le Unit:
City: Fort I Gc State: FL Zip:
Duct Leakage Test Results
System 1
C{U
cfm25
System 2
cfm25
System 3
cfm25
um of any
dditional systems
cfm25
Total of all
systems
0
cfm25
OPrescriptive Method cfm25 (Total)
To qualify as "substantially leak free" Qn must be less than or equal to
0.04 if air handler unit is installed. If air handler unit is not installed,
Qn Total must be less than or equal to 0.03. This testing method
meets the requirements in accordance with Section R403.3.3.
�I Performance / ERI Method cfm25 (out or Total)
I
To qualify using this method, Qn must not be greater than the
proposed duct leakage Qn specified on Form R405-2017 or R406-2017.
U, 0 y U Qn Leakage Type selected on Form Qn specified on Form R405-2014
Total of all Total Conditioned
systems Square Footage R405 2017 (Energy Calc) or R406-2017 (Energy Calc) or 406 2017
Fx]PASS [--]FA I L F--- Leakage to outdoors _ 10,oll(-)
�—
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section
553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes.
Testing Company
Company Name: UES, Universal Engineering Sciences Phone: 772-924-3575
1 hereby verify that the above duct leakage testing results are in accordance with the 2017 6th Edition Florida Building Code Energy
Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test: 05 /G 1 Wa I
Printed Name of Tester: Sean Thacker