HomeMy WebLinkAboutInstallation Instruction; Model 1101 V Series All Steel Foundation System Pan & Concrete� l�
467 SN/an Ave is Hohenwald, TN 38462 s (80
OLIVER TECHNOLOGIES, INC.
INSTALLATION INSTRUCTIONS FOR FLORIDA
MODEL 1101 "V" SERIES ALL STEEL FOUNDATION SYSTEM PAN & CONCRETE (revision 51181
PATENT# 6634150 & OTHER PATENT PENDING
REVISED
By SEAN SWONWR afb:32 am,• 8l3irl8
REVIEWED
By SEAN SW0NGER:at-6:33 am, 8/31/18
RECEIVED
MAR 0 2 2020
ST. Lucie County, Permitting
`�.so'gat:scrs
0 e V �A
0...02 2 ee a
-9 STATE OF
tk. OP...
•f v
aab�aeea $ +°g�
Aug 24, 2018
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
I
4. Choose one of the approved longitudinal tube installations; eithe
diagram for appropriate pier height at support location or cut anc
PIER HEIGHT 1.25" 1.50"
(40' Min. - 45° Max.) Tube Length Tube Length
7 3/4" to 25"
22"
18" .;
24314" to 321 /4"
32"
33" to 4l"
44"
40" to 48"
54"
18"s
OLIVER TECHNOLOGIES, INC.
FLORIDA INSTALLATION INSTRUCTIONS FOR THE
MODEL 1101 "V" SERIES ALL STEEL FOUNDATION SYSTEM
MODEL 1101"V" (steps 1-14)
LONGITUDINAL ONLY: Follow Steps 1-9
LATERAL ONLY: Follow Steps 1-3 and Steps 10-14
ENGINEERS STAMP FOR CONCRETE APPLICATIONS: Follow Steps 15-18 ENGINEERS STAMP
1. SPECIAL CIRCUMSTANCES: If the following conditions occur - STOP! Contact Oliver Technologies at 1400-284-7437:
a) Pier height exceeds 48" 0 Roof eaves exceed16" e) Location is within 1500 feet of coast
b) length of home exceeds 76 d) Sidewall height exceed 96")
�1STlOLLATION OF GROUND PAN
2. Remove weeds and debris in an approximate two foot square to expose firm soil for each ground pan (C) .
3. Place ground pan (C) directly below chassis 1-beam. Press or drive pan firmly into soil until flush orb' tour sotl_then install pier per
manufacturer's instructions or per Florida Regs.
SPECIAL NOTE: The longitudinal W" brace system may also serve as a pier under the home and should be loaded as any other pier.
It is recommended that after leveling piers, and one-third inch (1/3") before horse is low&4d,completely on to piers, complete
steps 4 through 9 below then remove jacks.
MICTAI a ATrnta nc i nMrrar rniraal "v" RRarr. SYSTEM MModel 1101 L " V")
NOTE: WHEN INSTALLINGTHE LONGITUDINAL SYSTEM ONLY, A MINIMUM OF 2 SYSTEMS PE
USED TO DETERMINE CORRECT TYPE OF ANCHOR PER SOIL CLASSIFICATION. IF PROBE TEST
BE USED. IF PR08ETEST READINGS ARE BETWEEN 276'& 350 A 4 FOOT ANCHOR MAY BE
STABILIZER PLATES EVERY 5W' . VERTICAL TIES ARE ALSO REQUIRED ON HOMES SUOPLIED'1
or B.TI?en select the correct square tube (E) length from the
acre tube to achieve appropriate length.
PIER HEIGHT 1.50"
9/t6 i)15 l.S62"j holed (4W Min. - 60° Max.) Tube Length
Part E
0
CTION IS REQUIRED. SOILTEST PROBE SHOULD BE
A{2E BETWEEN 175 & 275 A 5 FOOT ANCHOR MUST
GROUND ANCHORS WITH DIAGONAL TIES AND
-ALTIE CONNECTION POINTS (PER FLORIDA REG.).
14" to 18"
20"
18" to 25"
28"
24" to 35"
39"
30" to 40"
44"
36" to 48"
54"
Diagram A-o.�s°
Y. Diagram B
5. Install (2) of the 1.50" square tubes}{E) into the' U"bracket (J), insert carriage bolt and leave nut loose for final adjustment.
6. Place I-beam connector (F) loosel}r on ihe4botto,m flange of the I-beam.
7. (For Diagram A installation) Slide the.._selected 1.25" tube (E) into a 1.50" tube (E) and attach to I-beam connectors (F) and fasten loosely
with bolt and. nut. (For Diagram B installation) Attach the selected 1.5" tubes (E) to the I-beam connectors (F) and fasten loosely with bolts
-and nuts.
8_ Repeat steps 6 through 7 to create the "V" pattern of the square tubes loosely in place.
9. Using standard hand tools tighten all nuts and bolts. (For Diagram A installation only; secure 1.25" and 1 .50" tribes using.
four(4) 1 /4"-14 x 3/4" self -tapping screws in pre. -drilled holes.)
INSTALLATION OF LATERALTELESCOPINGJ. TRANSVERSE ARM SYSTEM {Model 1101 T "V")
THE MODEL 1101 "V" (LONCITUDINAL & LATERAL PROTECTION) ELIMINATESTHE NEED FOR STABILIZER PLATES & FRAMETIES.
NOTE: THE USE OF THIS SYSTEM REQUIRES VERTICALTIES SPACED AT 5'4".
FOUR FOOT (4') GROUND ANCHOR MAY BE USED EXCEPT WHERE THE HOME MANUFACTURER SPECIFIES DIFFERENT.
10. Install remaining vertical tie -down straps and4' ground anchors per home manufacturer's instructions. NOTE: Centerline anchors
to be sized according to soil torque condition. Any manufacturer's specifications for sidewall anchor loads in excess of•4,000 lbs.
require a 5' anchor per Florida Code.
11. Select the correct square tube brace (H) length for set-up lateral transverse at support location. The lengths come in either 60" or
72`' lengths. (With the 1.50" tube as the bottom tube, and the 1.25" tube as the inserted tube.)
12. Install the 1.50 transverse brace (H) to the ground pan connector (D) with bolt and nut.
13. Slide 1.25" transverse brace into the 1.50" brace and attach to adjacent I-beam connector (1) with bolt and nut.
14. Secure 1.56" transverse arm to 1.25" transverse arm using four (4)1 /4" -14 x 3/4" self -tapping screws in pre -drilled holes. Page
PATFNT9 AAaAi r%n !L nTHFR PATFNTPI:NnINr, Revision 08/23/1 E
=467 Swan Ave • Hohenwald, TN 38462 s (800) 284-7437 s yvww.olivertechnoiogies.com
Fax (931)
INSTALLATION USING CONCRETE RUNNER/ FOOTER
15. A concrete runner, footer or slab may be used in place of the steel ground pan.
a) The concrete shall be minimum 2500 psi,mix
b) A concrete runner may be either longitudinal or transverse, and must be a minimum of 8" deep with a minimum width of 16 inches
longitudinally or 18 inches transverse to allow proper distance between the concrete bolt and the edge of the concrete (see below).
Q Footers must have minimum surface area of 441 sq. in. (I.e. 21" square), and must be a minimum of 8" deep.
d) If a full slab is used, the depth must be a 4" minimum Special inspection of the system bracket installation is not required. Footers
must allow for at least 4" from the concrete bolt to the edge of the concrete.
NOTE: The bottom of all footings, pads, slabs and runners must be per local jurisdiction.
LONGITUDINAL: (Mode! 1101 LC "V!
16. When using Part# 1101-W-CPCA (wetset) simply install the bracket in runner/footer OR When installing in cured concrete use Part#
101-D-CPCA (dryset). The 1101 (dryset) CA bracket is attached to the concrete'using (2) 5/8" x3" concrete wedge bolts (Simpson part #
S162300H 5/8" X 3" or Powers equivalent). Place the CA bracket in desired location. Mark bolt hold' Iocations, then using a 5/8" diameter
masonry bit, drill a hole to a minimum depth of 3". Make sure all dust and concrete is blown out of>tbe holes: Place wedge bolts into drille
holes, then place 1101 (dry set) CA bracket onto wedge bolts and start wedge bolt nuts. Take a,hammer and lightly drive the wedge bolts
down by hitting the nut (making sure not to hit the top of threads on bolt). The sleeve of concrete wedge bolt needs to beat or below thf
top of concrete. Complete by tightening nuts.
17. For wet set (part # 1101-W TACA) installation simply install the anchor bolt into runi erlfoote? For dry set installation (part # 1101-D TACA
mark bolt hole locations, then using a 5/8" diam. masonry bit. drill a hole to a minlmUm depth of 3". Make sure all dust and concrete is
blown out of the hole. Place wedge bolts (Simpson part #5162300H 5/8" X 3" or Pow6m:.Lquivalent) into (D) concrete dry transverse
connector and into drilled hole. If needed, take a hammer and lightly drwe.the wedge bolts down by hitting the nut (making sure not to
hit the top of threads on bolt), then remove the nut. The sleeve of concrete wedge bolt needs to be at or below the top of concrete_
. 8. When using part# 1101 CVW (wetset) or 1101 'CUD (dryset), install -per steps l7 & 18.
Notes:
1. LENGTH Of HOUSE IS THE ACTOAL BOX SIZE
2. ; LOCATION OF TRANSVERSE BRACING ONLY
3 = LOCATION OF LONGITUDIN4 BiRACING ONLY
4. kJ- = TRANSVERSE AND LONGITUDINAL LOCATIONS
AND LENGTHS UP TO52'
i
ALL WIDTHS AND LENGTHS OVER52' TO 80"
rLLi
I
I 'j
I
L
HOMES WITH 5/12 ROOF PITCH REQUIRE: PER FLORIDA REGULATIONS
6 systems for home lengths up to 52' and 8 systems for homes over 52' and up 80.
PATENT# 6634150 & OTHER PATENT PENDING P ae 2
Revision 08/23/1E �-
i
I -Transverse Arm,I-Beam Connector
D -Pan
H -Transverse Arm
/Top (1.25`)
Bottom t t 51
C - Ground Pan
I -Transverse Arm. I -Beam Connector
I Cement Block
Omitted. t
LFor Clarity j
D - Concrete
rL
Connector
C-Concrete SI
Pooter
Nrl * 1101- D - TACA
H -Transverse Arm Part # 110 1- W - TACA not shown
Top (1.25,)
Bottom (1.5")
I CMU - Pier
Omitted
IFor Clarity I J
Bolts
78' Mau. `
Model # 1101 T'IV" Model # 1101 TC "V"
Florida approved 4' ground anchors may be used in all locations except where home manufacturers'spedfications for sidewall
straps are in excess of 4,000 lbs.These locations require a S' anchor. Per Florida code. .
C = GROUND PAN / CONCRETE FOOTER OR RUNNER
D = GROUND PAN / CONCRETE U BRACKETS TRANSVERSE CONNECTOR (connects with grade 5,F 1/2' _2" 1/2" carriage bolt and nut)
E=TELESCOPING V BRACE TUBE ASSEMBLY (i_5" TUBE BOTTOM AND 1.25" TUBE INSERT} TUBE
F = "V" BRACE 1-BEAM CONNECTOR ASSEMBLY ° t.
H = TELESCOPING TRANSVERSE ARM ASSEMBLY
i =TRANSVERSE ARM I -BEAM CONNECTOR (connects with grade 5 -1 /2".;x 2" 7 /2" carnade`bolt and nut)
J =V PAN BRACKET (connects with grade 5 -1/2"x 2" 1/2"carriage bolt`and nut)
1-Transverse Arm, I -Beam
D - Part Transverse Connector
/ Concrete Transverse Bracket
E - N" Brace Tube ( 7.5")
Model # 1101 " T
PATENT# 6634150 & OTHER PATENT PENDING
Part: 11'J1 D-CPCA.
Part r t 101 W-CPCA nat shown
Model, # 1191 C "V"
Page.3
Revision 08/23/1 E