HVAC & Mechanical Plan
MECHAMCAL SYMBOL LEGEND GENERAL NOTES: U DUCTWORK SYSTEM SYMBOLS SCHEDULE FOR 24"x24" CEILING SUPPLY DIFFUSER REFRIGERANT PIPING NOTES 1' RIZE HIMSSEY WITOR TO H E EXISTING FIELD CONDITIONITTING A BID, THE SANDHYSICALhC'ONSTRAINTS ASSOCIATED WITH E JOB SITE TO THOROUGHLY ATHE AWORK TO BE o ACCOMPLISHED UNDER THIS CONTRACT, 2. ALL WORK SHALL COMPLY WITH THE_ LATEST EDITIOM OF THE FOLLOWING CODES AND STANDARDS: FLORIDA MECHANICAL CODE, FLORIDA ENERGY CODE, NFPA-BOA STANDARDS FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS, SMACNA (DUCT CONSTRUCTION STANDARDS, ASHRAE 62.1 3. VERIFY FINAL LOCATIONS FOR ROUGH -INS WITH FIELD MEASUREMENTS AND WITH REQUIREMENTS OF THE ACTUAL EQUIPMENT TO BE INSTALLED. 4. COORDINATE THE CUTTING AND PATCHING OF BUILDING COMPONENTS TO ACCOMMODATE THE INSTALLATION OF HVAC EQUIPMENT AND MATERIALS. 5. PROVIDE WEATHER PROTECTION FOR ALL EQUIPMEN'E AND MATERIALS STORED ON SITE. SYMBOL DESCRIPTION SYMBOL o NECK FLEX CONNECTION CFM RANGE FINISH REMARKS 1. REFRIGERANT PIPING SHALL BE TYPE 'K" OR "L" SOFT DRAWN COPPER 'TUBING NTH WROUGHT COPPER SOLDER TYPE FITTINGS SUITABLE FOR CONNECTION WITH SILVER SOLDER. 2. COOLING COIL DRIP PIPING SHALL BE TYPE " M" COPPER OR SCHEDULE 40 PVC. PROVIDE 4' DEEP TRAP. 3. 3. PROVIDE ALL VALVES AND SPECIALTIES AS SHOWN BY THE ® SUPPLY AIR DUCT SECTION (UP/DOWN) ® zRETURN, OUTDOOR OR EXHAUST AIR DUCT SECTION (UP/DOWN) ® 0OUTDOOR AIR DUCT SECTION (UP/DOWN) ® EXHAUST AIR DUCT SECTION (UP/DOWN) 4 WAY BLOW cOP-t s" s" 0 - 125 OFF-WHITE OA BO CDP-2 8" 8" 128'- 225 OFF-WHITE O O CDP-3 10" 10" 226 - 400 OFF-WHITE AO OB Y BLOW 2 WAA CDP-4 12' 12" 401 - 600 OFF-WHITE Q Q DETAILS AND AS REQUIRED FOR A COMPLETE OPERATING - EXHAUST OR TRANSFER AIR FLOW SUPPLY AIR FLOW QUADRANT REFRIGERATION SYSTEM. 4. VALVES AND SPECIALTIES SHALL BE AS FOLLOWS: 4.1. AGLOBE VALVES, FORGED BRASS, BACKSEATING TYPE 6. 7. VENTILATION DUCTWORK SHALL BE SHEET METAL 44D INSTALLED IN ACCORDANCE WITH SMACNA. ALL OTHERRETURN, DUCTWORK SHALL BE AS SHOWN ON THE PROJECT PLANS. DUCTWORK INSULATION SHALL COMPLY WITH THE FLORIDA ENERGY CODE REFER TO ELECTRICAL CEILING GRID UGHTING PLAN FOR EXACT LOCATION OF AIR DISTRIBUTION DEVICES BLOCK SCHEDULE FOR 24"X24" CEILING RETURN DIFFUSER MD ❑yam VDI FD LD--- MOTORIZED DAMPER MANUAL VOLUME DAMPER FIRE DAMPER 500 PSI 4.2. CHECK VALVES, FORGED BRASS, 500 PSI 4.3. SOLENOID VALVES, FORCED BRASS, 400 PST 8. 9. PROVIDE ALL DUCT TRANSITIONS REQUIRED TO CONNECT EQUIPMENT SHOWN TO DUCT SYSTEMS. PROVIDE DUCT MOUNTED SMOKE DETECTORS ON THE: SUPPLY OF ALL AIR HANDLING SYSTEMS 2000 OEM AND GREATER. SYMBOL 0 NECK CONFLEX CTION CFM RANGE FINISH REMARKS o RD-1 6" 6" 0 - 125 OFF-WHITE Oc ® RD-2 8" 8" 126 - 225 OFF-WHITE OC SD >- AD ® SMOKE DAMPER ACCESS DOOR 4.4. REFRIGERANT STRAINERS, BRASS, 350 PSI, 100 MESH STRAINER 4.5. MOISTURE INDICATOR, FORGED BRASS, OPTICAL GLASS, 500 PSI 10. 11. MECHANICAL EQUIPMENT ON ROOF OR ELEVATED SIRUCRIRES SHALL COMPLY WITH FMC-2017 SEC. 306.5 & FBC-2017 SEC. 1510.10. MECHANICAL EQUIPMENT INSTALLED IN ATTICS / ABOVE CEILINGS MALL COMPLY WITH FMC-2017 SEC. 306.3. MECHANICAL EQUIPMENT, APPLIANCES & SUPPORTS THAT ARE EXPOSED TO WIND SHALL BE DESIGNED & z RD-3 to" 10" 226 "- 400 OFF-WHITE Oc Fort Pierce Engineering, Inc. RD-4 12" 12" 401 - 600 OFF-WHITE C O FLEXIBLE DUCT CONNECTION ELBOW WITH TURNING VANES SUPPLY DIFFUSER WITH 4-WAY BLOW SUPPLY DIFFUSER WITH 2-WAY BLOW 4.6. FILTER DRYER, STEEL SHELL, REPLACEABLE FILTER,& DRYER 5. REFRIGERANT PIPING JOINTS: ALL JOINTS SHALL BE MADE WITH SILVER SOLDER. THE PIPING SHALL BE CHARGED WITH DRY NITROGEN WHILE CONSTRUCTING THE JOINTS. AREMOVABLE TYPE DRYER STRAINER SHALL BE INSTALLED IN THE LINE. A ROVIDEDDFOR THE STRRAINR, AFTER THE REFRIGERANT BE PIPING HAS BEEN COMPLETED, THE REFRIGERANT SYSTEM SHALL BE PRESSURE TESTED WITH NITROGEN AT A PRESSURE OF 300 PSI (HIGH SIDE) AND 150 PSI (LOW SIDE). WHILE THE SYSTEM IS BEING PRESSURE TESTED, AN 12. 13. INSTALLED TO RESIST THE WIND PRESSURES DETERMINED IN ACCORDANCE WITH FBC-BUILDING. ALL NAND LOAD DRIER COMPLIANCE CALCULATIONS AND / OR $ STALLATION DETAILS FOR ROOF MOUNTED EQUIPMENT AS REQUIRED BY FBC-2017 SEC. 1510, 1522, & CHAPTER 16 SHALL BE PROVIDED BY STRUCTURAL ENGINEER / ARCHITECT. CONTRACTOR TO PROVIDE WIND LOAD CALCULATIONS SIGNED & SEALED BY A FLORIDA REGISTERED STRUCTURAL ENGINEER FOR NON PRE -APPROVED r,'ONFIGURATIONS DEVIATING FROM THE ORIGINAL CONSTRUCTION DOCUMENTS. CONTRACTOR SHALL PATCH & REPAIR EXISTING RONING MATERIAL AS REQUIRED BY AN APPROVED ROOFING CONTRACTOR FOR ROOFING MEMBRANE ORIGINALLY INSTALLED SO AS TO NOT VOID WARRANTY. CONTRACTOR IS TO PROVIDE REQUIRED STRUCTURAL STEEL FRAMEWDIRK FOR ADDMONA SUPPORT. CONTRACTOR SHALL BE RESPONSIBLE FOR ACQUIRING A STRUCTURAL ENGINEER FOR SIZING OF STRUCTURAL STEEL FRAMEWORK REQUIRED. ° CLEARANCE FOR MAINTENANCt SERVICE, REPAIRS &, REPLACEMENT FOR ALL MECHANICAL EQUIPMENT SHALL BE Depen &bPlumbi g Designlectrical Reg. No. 28173 II RD-5 i e 14" 601 - 900 OFF-WHITE O RD-6 16" 16" 90t 1250 OFF -WHILE OC REMARKS: A ALL SUPPLY DIFFUSERS SHALL BE 4-WAY BLOW UNLESS OTHERWISE SHOWN, METALAIRE 50DD, OR EQUAL BY TITUS. B. DO NOT INSTALL DAMPER IN DIFFUSERS USE DAMPER AT FLEX TAKE -OFF TO BALANCE AIR FLOW. DIFFUSERS IN INACCESSIBLE CEILINGS SHALL BE PROHDEIT WITH CABLE OPERATED DAMPERS ADJUSTABLE FROM DIFFUSER FACE C. ALL RETURN DIFFUSERS SHALL BE METALAIRE RH, OR EQUAL BY TITUS SPLIT SYSTEM EQUIPMENT SCHEDULE ®WEIGHT O ® SUPPLY DIFFUSER WITH QUADRANT BLOCK SD - SDEWALL DIFFUSER RETURN, TRANSFER OR EXHAUST GRILLE OR REGISTER EXHAUST FAN AIR HANDLERS ELECTRONIC LEAK DETECTOR SHALL BE USED TO CHECK FOR LEAKS. PRESSURE SHALL BE MAINTAINED ON THE SYSTEM FOR A MINIMUM OF 12 HOURS. THE SYSTEM SHALL THEN BE EVACUATED TO 2.0 MM MERCURY AND THEN CHARGED AND MADE READY FOR INSULATION. 6. PIPING EXPANSION AND VIBRATION ELIMINATION: PROVIDE REFRIGERANT TYPE FLEXIBLE CONNECTIONS AT THE AIR THEINSTALIA11ON SHALL BEAATDLEASTHff IN LENGTH AND SHALL CONNECTORS LOCATED TO EFFECTIVELY CONTROL VIBRATION AND TO ALLOW FOR CHANGES IN PIPE: LENGTH. 14. 15. PROVIDED TO COMPLY WITH FMC-2017 SEC. 306. SERVICE ACCESS PANELS FOR MECHANICAL EQUIPMENT IN CONCEALED SPACES SHALL BE PROVIDED TO COMPLY WITH THE REQUIREMENTS OF SEC. 306. PROVIDE AIR BALANCE TO QUANTITIES SHOWN ON 1HE PLANS. PROVIDE ALL VOLUME DAMPERS REQUIRED TO ACCOMPLISH AIR BALANCE. --SUBMIT BALANCE REPORT FOR REVIEW SYSTEM TEST At BALANCE REPORT (PREPARED BY SEPARATE 3RD PARTY AABC/NEBB CERTIFIED TO CONTRACTOR) TO BE INCLUDED WITH INSTALLATION. PRONIDE REPORT TO OWNER AND ENGINEER FOR REVIEW. WILL NOT BE CONSIDERED COMPLETE WITHOUT T&B REPORT. HVAC CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY VOLUME DAMPERS, EQUIPMENT, ADJUSTMENTS, ETC. REQUIRED TO ACHIEVE SATISFACTORY T&B RESULTS. 315 South 7th Street Fort Pierce, FL.34950 Phone: 772 672-4636 Fax: 772 672-4637 DESIGNATION AHU-I N3 2 AHU-3 � AHU-4 MANUFACTURER PROTOTYPE MODEL TRANE TEM6AOC6OH51 TRANE TEM6AOC36H31 TRANE TEM6AOC48H41 (POUNDS) 00 150 200 NOM. TONS 5 3 4 DP-1 --- -- O OROOF ROUND CEILING DIFFUSER LINEAR DIFFUSER AIR DEVICE; TYPE AND CAPACITY SQUARE TO ROUND TRANSITION EXISTING DUCTWORK OR EQUIPMENT TO REMAIN EXISTING DUCTWORK OR EQUIPMENT TO BE REMOVED NEW DUCTWORK OR EQUIPMENT ROOF CENTRIFUGAL FAN, EXHAUST CENTRIFUGAL FAN, SUPPLY 16. THESE DRAWINGS ARE PREPARED PER ESTABLISHED INDUSTRY STANDARDS AND REPRESENT THE ENGINEER'S DESIGN CONCEPT. THEY ARE NOT INTENDED TO PROVIDE EVERY DETAIL OR CONDITION REQUIRED TO CONSTRUCT THE BUILDING. THE CONTRACTOR THROUGH SUBMITTALS AND OTHER COORDINATION EFFORTS IS FULLY RESPONSIBLE FOR PROVIDING A COMPLETE AND OPERATIONAL BUILDING WHETHER INDICATED ON THE PLANS OR NOT. ' W A W �' E U LU V a [� , o 0 Q Fr o 0 0 Ld 0 1-0 w w 3 a z 0 0 L- co a w 0 0_ m � H v M SYSTEM CAPACITY (BTU/HR) TOTAL /SENSIBLE 56,51E 38,545 34,630 / 25,040 46,055 / 32,926 TOTAL AIR FLOW (CFI) I, 25 1,050 1,400 - OUTDOOR AIR FLOW (CFM) 250 150 150 PIPE INSULATION NOTES �_� FIBRE DUCT IN&VALLATION DETAILS EXTERNAL STATIC PRESSURE 0.5" 0.511 0.5" - 1. CONDENSATE DRAIN LINES SHALL BE INSULATED WITH 1/2' THICK "ARMAFLEY', OR EQU,4L 2. THE REFRIGERANT SUCTION (LINES SHALL BE INSULATED WITH 1' THICK "ARMAFLEX", OR EQUAL THE SUCTION LINE SHALL BE INSULATED IN ITS ENTIRETY INCLUDING VALVES AND SPECIALTIES. VALVES AND SPECIALTIES THAT REQUIRE ACCESS SHALL HAVE SPECIAL REMOVABLE COVERS. 3. ALL INSULATION SHALL BE VAPOR SEALED AND BUTT JOINTS OF 'ARMAFLEX' SHALL BE TAPED TO PREVENT INTRUSION AT THE JOINT. 4. SADDLES SHALL BE USED AT ALL PIPE HANGERS TO PREVENT COMPRESSION OF THE INSULATION. DUCT CONSTRUCTIIDN NOTES 1. ALL DUCT WORK, DUCT FITTINGS, DUCT FLEXIBLE CONNECTIONS, AND FLEXIBLE DUCT SHALL BE CONSTRUCTED AND LNSTAL1ED, AS A MINIMUM, IN ACCORDANCE NND WITH THE STANDARDS AND RECOMMENDATIONS OF "SMACNA" LATEST PUBUCATIONS AND STANDARDS. 2. ALL (DUCT WORK SHALL BE CONSTRUCTED OF I-I/2' FIBRE BOARD EXCEPT EXHAUST 8 VENTILATION DUCTS WHICH SHALL BE SHEET METAL. FIBRE DUCTS SHALL BE CONSTRUCTED WITH 1-1/2, BOARD WITH ANTI-FUNGAL INTERIOR COATING. EXPOSED SPIRAL DUCT SHALL BE DOUBLE WALL, I° INTERIOR INSULATION, PAINTED GALVANIZED STEEL. 3. DUCT HANGERS AND SUPPORTS SHALL COMPLY W'FH "SMACNA" STANDARDS IN GENERAL, HOWEVER DUCT STRAPS SHALL BE USED UP TO 48" IN HORIZONTAL DIMENSION (OR ROUND). DUCTS GREATER THAN 48- SHALL BE SUPPORTED WITH TRAPEZE HANGERS AND STEEL RODS. COIL EAT'F db/wb COIL LAT °F db/wb FAN MOTOR HP 7 .I % 65.7 55.9 / 53.8 3/4 H.P. 77.9 / 65.5 55.6 / 54.3 1/2 H.P. 77.2 / 64. 552 / 53.,`, 3/4 H.P�-� -' HEATER, KW STAGES IOK / I 5KW / I 7.5KW / I ELEC.-VOLTS/PHASE/MCA/MOCP 208-230 / I / 59 / 60 208-230 / I / 30 / 30 208-230 / I / 49 / 50 -v CONDENSING UNITS (R-410A) DESIGNATION CU-I a 2 CU-3 CU-4 - -®-. - ELECTRIC DUCT HEATER 2" UNDERCUT 4. 5. 6. 7• & 1.1 2• 3 4. ALL DUCTS SHALL BE OF THE SIZE AND SHAPE AS SHOWN BY CONTRACT DOCUMENTS ALL FLEXIBLE DUCTS SHALL COMPLY WITH UL 181. �T.EX DUCTS SHALL NOT BE GREATER IN LENGTH THAN 10'. WHERE LENGTHS GREATER THAN 10' ARE SHOW) AN THE: PLANS INSTALL ROUND SHEET METAL TO WITHIN 10' OF THE DEVICE BEING SERVED. SHEET METAL TURNING VANES SHALL BE PROVIDEDIN ALL SUPPLY AND RETURN RECTANGULAR DUCT NTH AN(XES GREATER THAN 30DEG . DUCTWORK PENETRATING FIRE RATED WALLS SHALL. BE EQUIPPED WITH FIRE DAMPERS. NO OPENINGS WITHIN 5' ON EITHER SIDE OF THE FIRE RATED WALL DUCTWDRK ON EACH SIDE OF A FIRE RATED WALL (6) SHALL BE A MINIMUM OF 26 GA. SHEET METAL ALL DUCT DIMENSIONS SHOW) ARE CLEAR INSIDE D9MEWWNS DUCT INSULATION NOTES All I INSULATION SHALL COMPLY NTH THE "FLORIDA, ENERGY CODE' LATEST EDITION, BLE DUCTS SHALL BE OF E LOW PRESSURE FACTORY FABRICATED TYPE CONSISTING OF A ZINC COATED SPRING STEEL HELIX NON-PEFORATED INNER LINING AND 1-1/2' THICK FIBERGLASS INSULATION NTH METALLIZED MYIAR VAPOR BARRIER. '; ALL INSULATION SHALL HAVE A MAXIMUM FLAME SPREAD/ SMOKE DEVELOPED RATING OF 25/50 DUCT SUPPORT HANGERS SHALL PASS AROUND THE OUTSIDE OF THE INSULATION USING SHIELDS OR SADDLES SO AS NOT TO COMPRESS THE INSULATION �� w � Z z 0 -" � j � Lam- J o 0 0 � p 0 o cai Ld 0 _ q J 0 0 a z a W 000 PROTOTYPE MANUFACTURER MODEL TRANE 4TTR7060AI TRANE 4TTR7036AI TRANE 4TTR7048BI ELECTRICAL CONNECTION NOTES PIPE SIZE, SUCTION/LIQUID, IN. I I/8" / 3/8,° 3/4" / 3/8" 7/8" 3/ /8 I 1. COORDINATE POWER WIRING AND CONDUIT FROM PANEL THRU FUSED DISCONNECT TO UNIT WITH ELECTRICAL 2. COORDINATE THE FUSED DISCONNECTS WITH ELECTRICAL 3. MAKE FINAL CONNECTIONS TO AIR HANDLING UNIT WITH *GREENFIEL.D". MAKE FINAL CONNECTION TO CONDENSING UNIT NTH 'UQUIDTITE". FINAL CONNECTIONS SHALL BE A MINIMUM OF 3 FT. 4. ALL WRING SHALL BE COPPER. SEE ELECTRICAL DRAWINGS FOR WIRE SIZE. 5. CONTROL WRING SHALL BE RUN IN CONDUIT. 6. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONTROL WRING. 7. AIR HANDLING UNIT SHALL BE PROVIDED NTH SINGLE POINT OF ELECTRIC ENTRY. 8. MECHANICAL CONTRACTOR SHALL PROVIDE MOTOR STARTER AND HEATER CONTACTORS IN CONTROL PANEL CONTROL SYMBOLS ELEC.-VOLTS/PHASE/MCA/MOCP 208-230 / I / 41 / 60 208-230 / 1 / 24 / 35 208-230 / I / 28 / 45 - THERMOSTAT - 4°-0" A.F.F. MOUNTING HEIGHT HUMIDISTAT - 4'-0" A.F.F. MOUNTING HEIGHT ram-- TEMPERATURE SENSOR © STATIC PRESSURE SENSOR ® DUCT SMOKE DETECTOR fVD VOLUME DAMPER //AD AUTO DAMPER _ NOTES: I. AIR HANDLER & CONDENSING UNIT SAME MANUFACTURER. 2. ALL EQUIPMENT TO COMPLY WITH FLORIDA ENERGY CODE. 3. EQUIPMENT MANUFACTURER LISTED IS USE AS THE BASIS OF DESIGN 8IS NOT INTENDED TO LIMIT COMPETITION. ALTERNATE EQUIPMENT SHALL BE OF EQUIVALENT PERFORMANCE a QUALITY. 4. CONDENSING COILS TO HAVE FIELD APPLIED CORROSION RESISTANT COATING. 5. PROVIDE FREEZE SEAT ON INDOOR COILS. ' 6. SYSTEMS SHALL HAVE DUAL SPEED COMPRESSOR WHICH SHALL STAGE BASED ON COOLING DEMAND. 7. PROVIDE PROGRAMMABLE THERMOSTAT WITH INTEGRAL HUMIDISTAT FOR "COOLING FOR DEHUMIDIFICATION." 8. INSTALL CORROSION "GRENADE" ON SUCTION LINE AT EACH COMPRESSOR. ENGINEER SEAL �1TI ITttr ` `` •••"' eO '' �` �••• ••••O '� �: • � •• 9 z SA STATE OF •�� 41 %P,.0 i�Fs•� w %+0,. G` ONAV-���` �1 r t L L L 1 tt t"� Eric J. Svoboda, PE P.E. No. 60982 HVAC PIPING LEGEND ® -CPR- CONDENSER WATER RETURN -CWS- CONDENSER WATER SUPPLY EXHAUST FAN SCHEDULE MECHANICAL DRAWING INDEXTHM °° vaswrm xrc wrtxun oar rN scEcmc nwosr eWm amn v Wmr r¢xce vWnc�xws, ac rm TIM nar ws ruva�n a N ur x ro_Nac a nose m�uaNrs vmon vwna eut"mvn� IN rm`¢ wpamww we nu xwns s�soam SYMBOL - DEISCRIPTION SHEET -- DESCRIPTION ISSUED" ----CHWS- CHILLED WATER SUPPLY EF-I GREENHECK SP-B90, 75 CFM W/ BACKDRAFT DAMPER - CONNECT TO LIGHT SWITCH. 120V-1e, 0.65A M-1 HVAC GENERAL NOTES, SYMBOLS & SCHEDULES YES SHEET TITLE -CHWR- CHILLED WATER RETURN M-2 M-3 MECHANICAL HVAC PLAN MECHANICAL HVAC DETAILS YES YES HVAC GENERAL NOTES, SYMBOLS -HWS- HOT WATER SUPPLY & SCHEDULES -HWR- HOT WATER RETURN ISSUE DATE: 11-11-2020 DRAWN: EJS - - - - - REFRIGERANT PIPING CD CONDENSATE DRAIN FROM COOLING COIL APPROVED: EJS - DOMESTIC COLD WATER 1RE� C�M jANCE CC RECEIVED° DEC 17 1020 DRAWING NUMBER - G GAS PIPING le COUN-r�t CJ'tj, LucBO��- Perrhittfng DeOarment� Lucie County IIISt. IIIIIWIIII M NOTE: SOME NOTES & SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. SHEET I OF 3 20036-01 GENERAL NOTES: I. ROUTE REFRIGERANT LINES FROM EACH AHU UP ABOVE CEILING, THRU EXTERIOR WALL a DOWN IN METAL HAT CHANNEL TO RESPECTIVE CU. UUIblut AIK SCREEN. (TYPICAL) a a U OUTDOOR AIR CALCULATIONS �� o At�l1 25 PPL x 5 CFM = 125 CFM O.A. 1670 SO. FT. x 0.06 CFM = 100.2 CFM O.A. 225.2 CFM O.A. REOUIRED SHEET 2 OF 3 20036-01 STAND-OFF TO ALLOW INSULATE BELLS FOR INSULATION USE ROUND SHEET METAL DUCT HERE TO LIMIT FLEX DUCT TO 10'-0' IN LENGTH I TYPICAL AIR COOLED CONDENSING UNIT. 6"SADDLE 11 CEILING DO NOT LOCATE UNIT WHERE THE CEILING DIFFUSER FLEX FLEX UPBLAST WILL STRIKE ANY OVERHANG. PAD TO BE 4" LARGER ALL AROUND (�•) LOCATE UNIT MINIMUM OF 2'-O" THAN UNIT, FURNISHED WITH /4 w FROM BUILDING EXTERIOR WALL REBARS AT 6' O.C. BOTH WAYS WALL WALL NOTE USE BORDER TYPE 1 WHERE IN HARD CLGS. - ANCHOR UNIT TO PAD WITH GALV. STEEL BORDER TYPE C WHEN EXPOSED TIE -DOWN CLIPS, 2 PER SIDE, WITH MIN. 1/4" —_ — Fort Pierce Engineering, Inc. UP -FLOW AIR HANDLING MD DIA. EXPANSION BOLTS 01 1/2- EMBEDMENT UP —FLOW AIR HANDLING _ Dependable Mechanical, Electrical UNIT -SEE SCHEDULE FILTER UNIT -SEE SCHEDULE FILTER VO DEPTH, #12 X 3/4 SCREW INTO CASING. _ _ _ _ &Reg Plumbing 2Design 73 C.D. C.D. RETURN GRILL IN WALL 4" SUCTION k LIQUID REFRIGERANT LINES TAKE -OFF FITTING TRAP DUCT SUPPORT TRAP CEILING DIFFUSER. FLOOR / FLOOR INSULATE BELLS. DIRECTION SECURE FLEX DUCT TO TAKE -OFF SEE HVAC FLOOR % DUCT SUPPORT OF AIR I FITTING WITH STAINLESS STEEL PLAN FOR LOCATION J NEOPRENE PAD. (TYPICAL FOR 4) FLOW I SCREW DRIVER OPERATED BAND DIFFUSER CONSTRUCT PLENUM SUPPORT BASE FRAME PROVIDE EMERGENCY OVERFLOW SENSOR CONSTRUCT PLENUM SUPPORT BASE FRAME PROVIDE EMERGENCY OVERFLOW SENSOR FROM I k X I k X J' STEEL 8 ENCLOSE WITH WATER GARD PRIMARY PAN SENSOR /401475B FROM I �' X I #' X 'STEEL 8 ENCLOSE WITH WATER GARD PRIMARY PAN SENSOR /4014758 FLEXIBLE DUCT (I OR SECONDARY DRAIN HOLE SENSOR /4014908 OR SECONDARY DRAIN HOLE SENSOR y4014906 RUN REFRIGERANT LINES SHORTEST 8' THICK CONCRETE PAD - STRAP I I �' DUCT BOARD - SEAL WITH TAPE 8; MASTIC. WITH ALARM. WATER GARD INC. I DUCT BOARD - SEAL WITH TAPE 8 MASTIC. WITH ALARM. WATER GARD, INC. 4' ABOVE GRADE AND DUCT STRAP 2211 CEDAR GAP, HOUSTaN, TX 77072 12211 CEDAR GAP HOUSTON, 1X 77072 DISTANCE TO BLDG. EXTERIOR WALL 4' BELOW GRADE — — �22 1388-652-9800) (PH 888-652-98d0) SEE PLANS FOR CONTINUATION. 315 South 7th Street MIN. 30DO PSI Fort Pierce, FL. 34950 Phone: 772 672-4636 PLACE AIR HANDLING UNIT IN THE ROOM SO THAT SERVICE TO a Fax: 772 672-4637 —� THE UNIT do FILTER REPLACEMENT CAN BE ACCOMPLISHED. THE UNIT k FILTUERRGREPLACEMEENT CANBEOACCOMPLISim TO DAMPER CEILING NOTE: INSTALL TO WITHSTAND 170 MPH WINDS. SADDLE II INSULATION NOTE: USE BORDER TYPE 1 W WHERE IN HARD CLGS. - Q BORDER TYPE C WHEN EXPOSED w Q o PROVIDE GASKET BETWEEN TAKE OFF a FITTING AND BRANCH DUCT.�W o W a� o A FLEX DUCT CONNECTION DETAILS SCALE=(N.T.S.) B VERTICAL AHU DETAIL AHU-I C VERTICAL AHU DETAIL AHU-2, 3, & 4 D FAIR COOLED CONDENSING UNIT DETAIL �w . SCALE= (N.T.S.) SCALE = N.Ts.> x SCALE=(N.T.S.) O W W � 3a O z a o I- c0 r w oxm WV J L� M U SECURE TO STRUCTURE SENSING BULB ABOVE AS RECOMMENDED BY SMACN9 1 20 GA GALV. COIL DX COOLING METAL STRAP DUCT SCHEDT TLE INCHES DUCT DIMENSIONSfflB UP TO 18 19 TO 30 30 TO 60 NOTE: 8'-0" MAX HANGER SPACING v] C7 Q ❑ a a 00 W z 0 O Y O 1 Z 0 w Q THREADED CAP WITH z"0 I,V SECURE TO STRUCTURE z TWWX VALE HOLE DRILLED IN TOP, THREADED CAP, , L ABOVE AS RECOMMENDED v w HAND TIGHTENED BY SMACNA 3/g" DIA. THREADED O o o FL �� HAND TIGHTENED. HANGER UPPER ATTACHMENTS 0 C6 0 o 0 MOISTURE SIGHT GLASS SHEET METAL SCREW, SIZE. Y'R� STEEL HANGER ROD IN ACCORDANCE WITH n- a 0 w RIVET OR BOLT TO NOTES: SUCTION LINE AIR BOTH SIDES OF DUCT. SMACNA DETAILS 1. PROVIDE ACCUMULATOR IF DEVELOPED TYPE'' I SEE PLAN FOR EXHAUST ENGINEER SEAL LENGTH IS GREATER THAN 50 HANDLER A DUCT CONTINUATION �tttlllt 2. PROVIDE REFRIGERANT PIPE SIZES LIQUID LINE SLOPE TO UNIT i AND TERMINATION RUBBER -IN -SHEAR �N%% 3 SVO&I,,t i VIBRATION ELIMINATORS TNRECOMMENDED BY MFG. DRAIN I I \ DUCT SLEEV (TYPICAL FOR ALL 4 `` \ 3. SEE ALSO REFRIGERANT SYSTEM 9NOTES //pp�� TYPICAL RECTANGULAR DUCT HANGER RODS) ' 2 WITH REPLAACEABLE IN PANCORE CYER IDRA SLEEVE 1Yt•x16� EXHAUST ;� STATE OF 1Xt"z �q TYPE'B' DUCT �O,n% • CHARGE VALVE W/CAP UNION ANGLE GALVANIZED %�Fs•.<oR:•oPG���� UNITOT PROVIDED W11H HANGER FLEX. CONNECTION/ CABINET FAN ''�'�;0Ni �1��?``` NOTE: LOAD RATED TO EXHAUST FAN CEILINGZ Erfc J. Svobodc, PE 1. FILL TRAP MANUALLY ON INITIAL START-UP. �� FASTENER HANGER RODS, WIRES P.E. No. 60982 = OR CONDENSING 2. PIPE SIZE SHALL NOT BE LESS THAN DRAIN PAN CONNECTION SIZE. STRAPS • ^ r� nE r »� ors UNIT SEE 3. A = 1" + FAN SUCTION S.P. a DETAIL dt: EXHAUST FAN SCHEDULE CEILING GRILLE BASE B A 2 = / vmwr uamm m nc sxc �+mo,rmzcem, rvn 4. ALL CONDENSATE PIPING TO BE PVC. .� 5. INSULATE ALL DRAIN LINES WITH YY ARMAFLEX SHEET TITLE ISOLATION VALVES (TYPICAL) MECHANICAL BALL TYPE ISOLATION VALVES DETAILS IF NOT PROVIDED WITH UNIT `�36" DIA. MAX ISSUE DATE: 11-11-2020 BAND OF SAME SIZE BAND ONE HALF —ROUND AS HANGER STRAP MAY BE USED IF DUCT DRAWN: EJS TYPICAL ROUND DUCT SHAPE IS MAINTAINED APPROVED: EJS DRAWING NUMBER M-3 E REFRIGERANT PIPING SCHEMATIC SCALE= (N.T.SJ F CONDENSATE DRAIN TRAP DETAIL G DUCT SUPPORT DETAILS H CEILING CABINET EXHAUST FAN DETAIL SHEET 3 OF 3 scnlE _ (N.Ts.) scALE=1x.Ts.l scALE=(N.Ts.> 20036-01 a