HomeMy WebLinkAboutCompaction test1--'0 In -Place Density Report client: Associates, Inc. Permit # 2011-0278 Renar Development Corp. Report Date: 5/12/2021 3725 S. East Ocean Boulevard, Suite 101 Port St. Lucie Branch Test Method: ASTM D6938 Stuart, FL 34996 Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772-878-0072 ti 0%160-0- oq�� Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on May 13, 2021 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. W` }' In -Place Density Report Client: & Associates, Inc. Permit # 2011-0278 Report Date: 5/12/2021 Port St. Lucie Branch Test Method: ASTM D6938 Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772-878-0072 Renar Development Corp. 3725 S. East Ocean Boulevard, Suite 101 Stuart, FL 34996 Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL Test Results Maximum In Place In Place Optimum Dry In Place Dry Wet Probe Retest Soil Moisture Density (pcf) Moisture Density Density Depth Percent Min Comp. Test # Of Test Date Proctor ID Method Classification % (% (pc (pcf) (in) Compaction N Remark 444 514/21 21-097 A - 10.5 113.5 10.1 110.9 122.1 12 98 95 Pass (Modified) 445 5/4/21 21-097 A - 10.5 113.5 11.7 112.6 125.8 12 99 95 Pass (Modified) 446 5/4/21 21-097 A 10.5 113.5 9.4 111.3 121.8 12 98 95 Pass (Modified) 447 5/4/21 21-097 A 10.5 113.5 11.3 112.1 124.8 12 99 95 Pass (Modified) 448 5/4/21 21-097 A 10.5 113.5 12.0 112.0 125.4 12 99 95 Pass (Modified) 449 5/4/21 21-097 A 10.5 113.5 9.9 113.7 125.0t127 100 95 Pass (Modified) Test information ' Gauge Test # Test Location Elevation Reference Make / Model / SN / Calibrated Field Technician 444 Footings: Footings and Pad for Lot 55 at 9609 Rainwood Court. NW End of Footings -1.0 Bottom of footings CPN / MC-3 / M340507795 / Tech, Port St. Lucie 445 Footings: Footings and Pad for Lot 55 at 9609 Rainwood Court. NE End of Footings -1.0 Bottom of footings CPN / MC-3 / M340507395 / Tech, Port St. Lucie 446 Footings: Footings and Pad for Lot 55 at 9609 Rainwood Court. SE End of Footings -1.0 Bottom of footings CPN / MC-3/ M340507395 / Tech, Port St. Lucie 447 Building Pad Fill: Footings and Pad for Lot 55 at 9609 Rainwood Court. SE End of Pad 1.0 Bottom of footings CPN / MC-3 / M340507395 / Tech, Port St. Lucie 448 Building Pad Fill: Footings and Pad for Lot 55 at 9609 Rainwood Court. SW End of 1.0 Bottom of footings CPN / MC-3 / M340507395 / Tech, Port St. Lucie Pad 449 Building Pad Fill: Footings and Pad for Lot 55 at 9609 Rainwood Court. NW End of 1.0 Bottom of footings CPN / MC-3 / M340507395 / Tech, Port St. Lucie Pad Remarks Comments Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as 1"Backscatter". Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.