HomeMy WebLinkAboutRevisions; Energy CodeC- .opy
FORM R405-20 0 I E ED F U k
FLORID &&119 §Egy,ILDING
v
Florida Department of Business e r l rid� I frvResidential
CONSTRUCTION
Performance Method
Project Name: PSL-MYRTLE40
PO G ilaer am :
Street: 6609 MYRTLE DR
Permit Office:
City, State, Zip: FT. PIERCE, FL, 34982
I
Permit Number: ?jam
Owner.
Jurisdiction:
I
Design Location: FL, Fort Pierce
County. St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type42098.7 sgfQ
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Ext Insul, Exterior
R=4.1 1773.30 Rz
b. Frame - Wood, Adjacent
R=11.0 325.33 W
3. Number of units, if multiple family 1
c. NIA
R= ft°
4. Number of Bedrooms 3
d. NIA
R= ft'
S. Is this a worst case? No
11. Ceiling Types (1841.0 sgfL)
insulation Area
a. Under Attic (Vented)
R=40.0 1841.00 ft'
6. Conditioned floor area above grade (ft) 1641
b. WA
R- ft'
Conditioned floor area below grade (W) 0
c. WA
R= ft'
7. Windows(235.0 sqft.) Description Area
12. Ducts
a. Sup: Attic, Rot: Attic, AH: Main
R ft"
6 496
a. U-Factor: Dbl, U=0.62 235.00 ft'
SHGC: SHGC=0.26
b. U-Factor: N/A ft'
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
47.0 SEER:16.00
c. U-Factor: N/A ft'
SHGC:
Area Weighted Average Overhang Depth: 3.678 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.260
a. Electric Strip Heat
21.2 COP:1.00
8. Skylights Area
c. U-Factor.(AVG) WA ft'
15. Hot water systems
SHGC(AVG): WA
a. Electric
Cap: 50 gallons
9. Floor Types (1841.0 sgft) Insulation Area
EF:0.940
a. Slab -On -Grade Edge Insulation R=0.0 1841.00 ft'
b. Conservation features
b. WA R= ft'
None
c. N/A R= ft°
16. Credits
Pstat
Glass/Floor Area: 0.128 Total Proposed Modified Loads: 54.79
PASS
Total Baseline Loads: 59.80
1 hereby certify that the plans and specifications covered by
Review of the plans and
4�Kfi STAt
this calculation are In compliance with the Florida Energy
Code.
specifications covered by this
g
}V-u
calculation Indicates compliance
with the Florida Energy Code,
iSOS
a
PREPARED BY:
Before construction is completed
DATE: 03/23/2021
this building will be Inspected for
- X
compliance with Section 553.908
fy g, as es is in compliance
I herebycertify the rs
Florida Statutes.
with the Florida Energy Cod .
f''OD VV r' �
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
'
DATE:
- Compliance requires certificatloAy the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
3/23/2021 1:46 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPUT SUMMARY C14r-CKI.IRT RFPART
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment
PSL-MYRTLE-40
User
1
Detached
New (From Plans)
Bedrooms: 3
Conditioned Area: 1841
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 5609 MYRTLE DR
County: St. Lucie
City, State, Zlp: FT. PIERCE,
FL, 34982
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO BEACH MUNI 39 90
70 75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1841 17673.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1841 17673.6 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatto Main 221.7 R
1841 ft' 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emiti Emitt Deck Pitch
Bare Absor. Tested Tested Insul. (deg)
1
Hip Composition shingles 2058 R° 0 R' Medium
N 0.4 N 0.9 No 0 26.57
ATTIC
` /
v #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150 1841 R2 N N
CEILING
#
Ceiling Type
Space R Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 40 Blown
1841 ft= 0.1 Wood
3/23/2021 1'46 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
/
Adjacent
Space
Cavity Width Height
Sheathing Framing Solar
Below
-#-Omt- T4--_-WaIISype -
R ValuP Et (n Et In Area
R-Value-Fractlon-Absor^GradeJ�
1 N
Exterior Concrete Block - Ext Insul Main
4.1 47 0 9
4 438.7 ftz
0 0 0.3
0
2 E
Exterior Concrete Block - Ext Insul Main
4.1 29 4 9
4 273.8 ftz
0 0 0,3
0
-3 S
Exterior Concrete Black - Ext Insul Main
4.1 60 10 9
4 567.8 ftz
0 0 0.3
0
4 W
Exterior Concrete Block - Ext Insul Main
4.1 52 10 9
4 493.1 ftz
0 0 0.3
0
_ 5 -
Garage Frame - Wood Main
11 30 6 10
8 325.3 ftz
0 0.25 0.3
0
DOORS
#
Omt Door Type Space
Storms
U Value
Width Height
Area
Ft
In Ft In
1
E Wood Main
None
.39 3
8
24 ftz
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation Int Shade
Screening
1
N 1 Metal Double (Clear) Yes
0.62 0.26 N
6.5 ftz 1 ft 0 In
1 ft 0 In None
None
2
e 2 Metal Double (Clear) Yes
0.62 0.26 N
52.0 ftz 1 ft 0 In
1 ft 0 In None
None
3
e 2 Metal Double (Clear) Yes
0.62 0.26 N
10.7 ftz 6 ft 0 in
4 ft 0 in None
None
4
s 3 Metal Double (Clear) Yes
0.62 0.26 N
6.5 ftz 1 ft 0 In
1 ft 0 in None
None
5
w 4 Metal Double (Clear) Yes
0.62 0.26 N
43.3 ftz 1 ft0 In
1 ft 0 In None
None
6
w 4 Metal Double (Clear) Yes
0.62 0.26 N
52.0 ftz 1 ft 0 in
1 ft 0 in None
None
T
W 4 Metal Double (Clear) Yes
0.62 0.26 N
64.0 ftz 10 ft 0 In
1 ft 0 in None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
432 ftz 432 flz
64 It
9.3 ft
1
INFILTRATION
# Scope
Method SIA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000427
2061.9 113.12 212.38 .1359
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
COPA
21.24 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/ Split
Singl SEER: 16
47 kBtulhr
cfm 0.7 1
sys#1
3123/2021 1:46 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94
50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System
Model # Collector Model # Area
Volume
FEF
None None
ft=
DUCTS
--- Supply —
-- Return ---
Air
CFM 25
CFM25
HVAC #
V # Location R Vaiue Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 496 ft'
Attic
229 fts
Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling ((�� Jan [[ ]] Feb
Heating H Jan H Feb
ar
ar
War
Apr
WApr
May
May
Jun Jul
� Jun
Aug
� Aug
Sep
� Sep
�
Oct
Oct
Nov
Nov
Dec
Dec
Venting [[ II Jan [[[ ]]l Feb
Jul
t
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH) AM
7B
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78,
78
78
78
78
Heating (WD) AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
66 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default B.Ibs/s .ft.
0 ft=
0 ft
0.3
Main
3/23/2021 1:46 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 2
0 I 9
The lower the EnergyPerformance Index, the more efficient the home.
5609 MYRTLE DR, FT. PIERCE, FL, 34982
1. New construction or existing
New (From Plans)
2. Single family or multiple family
Detached
3. Number of units, if multiple family
1
4. Number of Bedrooms
3
5. Is this a worst case?
No
6. Conditioned floor area (11:2)
184.1
7. Windows** Description
Area
a. U-Factor. Dbl, U=0.62
235.00 ft2
SHGC: SHGC=0.26
b. U-Factor. N/A
ft2
SHGC:
c. U-Factor. N/A
ft2
SHGC:
d. U-Factor. N/A
ft2
SHGC:
Area Weighted Average Overhang Depth:
3.678 ft.
Area Weighted Average SHGC:
0.260
8. Skylights Description
Area
a. U-Factor(AVG): NIA
ft2
SHGC(AVG): N/A
9. Floor Types
Insulation
Area
a. Slab -On -Grade Edge Insulation
R=0.0
1841.00 112
b. N/A
R=
ft2
c. NIA
R=
ft2
10. Wall Type and Insulation
Insulation
Area
a. Concrete Block - Ext Insul, Exterior
R=4.1
1773.30 ft2
b. Frame - Wood, Adjacent
R=11.0
325.33 ft2
c. WA
R=
ft2
d. WA
R=
ft2
11. Ceiling Type and Insulation level
Insulation
Area
a. Under Attic (Vented)
R=40.0
1841.00 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
12. Ducts, location & Insulation level
R ft2
a. Sup: Attic, Rot: Attic, AH: Main
6 496
13. Cooling systems
kBtulhr
Efficiency
a. Central Unit
47.0 SEER:16.00
14. Healing systems
kBlu/hr
Efficiency
a. Electric Strip Heat
21.2
COP:1.00
15. Hot water systems
a. Electric Cap: 50 gallons
EF: 0.94
b. Conservation features
None
Credits (Performance method) Pstat
I certify that this home has complied will the Florida Energy Efficiency Code for Building
Construction through the above energy Having features which will be installed (or exceeded)
in this home before final inspection. Ot rwise, a new EPL Display Card will be completed
based on installed Code compliant featqres.
Builder Signature:
Address of New Home: S� o
Date: Z �y
City/FL Zip: ez
3 ys,qz
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/23/2021 1:46 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
• Load Short Form Job:
wrightsoft Date: Mar 8, 2021
Entire House By.
7+La�+
,•�.{1:.�'k�.irt:ft'1�_.�"�.�iIt4J�..si..ie " a4i� fiy.ra; j,x rF`N�� 4j 1PCQ1o—A .1 fiQrm� �on''..�`F,xz�..
For 41
•1• MYRTLE DR FT PIERCE, FL 34982
9 - o
• •
Htg
Clg
Infiltration
Outside db (OF)
43
92
Method
Simplified
Inside db (OF)
70
72
Construction quality
Semi -tight
Design TD (°F)
27
20
Fireplaces
0
Daily range
-
L
Inside humidity (%)
30
50
Moisture difference (grAb)
0
63
HEATING EQUIPMENT
COOLING EQUIPMENT
Make
Make Lennox
Trade
Trade LENNOX
Model
Cond ML14XC1-047-230K*
AHRI ref
Coil CBA27UHE-048-230*++TDR
AHRI ref10259428
Efficiency
100 EFF
Efficiency 13.0 EER,16 SEER
Heating input
6.2
kW
Sensible cooling 32900
Btuh
Heating output
21237
Btuh
Latent cooling 14100
Btuh
Temperature rise
12
OF
Total cooling 47000
Btuh
Actual airflow
1567
cfm
Actual airflow 1567
cfrn
Air flow factor
0.057
cfm/Btuh
Airflowfactor 0.047
cfmBtuh
Static pressure
0
in H2O
Static pressure 0
in H2O
Space thermostat
Load sensible heat ratio 0.76
ROOM NAME
Area
W)
Htg load
(Btuh)
Clg load
(Btuh)
HtgAVF
(cfm)
CIgAVF
(cfm)
DINING
139
4377
5876
252
276
KITCHEN
192
1911
2467
110
116
GREAT RM
426
3934
6450
226
303
PANTRY
31
35
306
2
14
BATH2
63
1098
644
63
30
UTILITY
57
57
703
3
33
BEDHALL
39
0
0
0
0
BED 2
175
3278
3565
188
167
BED 3
175
2857
3390
164
159
FOYER
68
1810
1399
104
66
MASTERSUITE
262
5193
6790
299
319
HER W IC
50
43 .
322
2
15
MASTER BATH
126
2159
1104
124
52
HIS W I('.
lap
rn'1
470
70
40
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft• 2021-Mar-2313:37:32
.wa.,e �•�..,w., Rlght-SLA000rfwrsal202121.0.05RSU29964 Pagel
% 'C'A -,sor%Doan"rtslwr,g-tuoltWAC1PSL-M1RTLE-40np Calc=MA Fror(Doorfacas: E
Entire House
1841
27253
33394
1567
1567
Other equip loads
0
0
Equip. @ 0.97 RSM
32292
Latent 000ling
10539
WITAI A
4RA4
979ra
Aoaan
4=7
4=7
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
WrlghtsOft• gOkSdtWUtiAMW202121.0.ObRSU20984
-MADowmrtAWdgFsoftWAC1P5L-MYRTLE-40jW Colo -MA FrodDooriacea: E
2021-Mar-2313:37:32
Page 2
- - wrightsofts Project Summary
Entire House
Job:
Date: Mar 8, 2021
By.
r, i w,
.'�"• ` h i . k•V r.reiS�, }i,r��,�`r �Yi�t3:."s!'��'ti"r�:i!Iiro�p.��'dt'liiformation , ;..' -y , d ;� : � �. {�.. �. �¢."a. ,` .
For. PSL-MYRTLE-40
5609 MYRTLE DR, FT. PIERCE, FL 34982
Notes:
•. +i✓� � r - fi,�t f t� �, ,.vx .L^ nt ^f raq,�.wk 4+'� 5.�-. .. .�
i �,! ti A `'� 'GI?'•"'� i h �s a t ♦ (+ q+ w-rnI :R:'«9
lhformation
Weather: Vero Beach Municipal AP, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db
43
OF
Outside db
92
OF
Inside db
70
OF
Inside db
72
OF
Design TD
27
OF
Design TD
20
OF
Daily range
L
Relative humidity
50
%
Moisture difference
63
gr/Ib
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure
22311
Btuh
Structure
26611
Stuh
Ducts
4941
Btuh
Ducts
6783
Btuh
Central vent (0 cfm)
0
Btuh
Central vent (0 cfm)
0
Btuh
(none)
e)
Humidification
0
Btuh
Blower
0
Btuh
Piping
Btuh
load
27253
Use manufacturer's data
n
Rate/swing multiplier
0.97
Infiltration
Equipment sensible load
32292
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Semi -tight
Fireplaces
0
Structure
8873
Btuh
Ducts
1665
Btuh
Central vent (0 cfm)
0
Btuh
Heat'
Cool'
(none)
Area (ft')
1841
1841
Equipment latent load
10539
Btuh
Volume (f?)
17720
17720
Airchanges/hour
0.26
0.14
Equipment Total Load (Sen+Lat)
42830
Btuh
Equiv AVF (cfm)
77
41
Req. total capacity at 0.70 SHR
3.8
ton
Heating Equipment Summary
Cooling Equipment Summary
Make
Make Lennox
Trade
Trade LENNOX
Model
Cond ML14XC1-047-230X*
AHRI ref
Coil CBA27UHE-048-230'++TDR
AHRI ref 10259428
Efficiency
100 EFF
Efficiency 13.0 EER,16
SEER
Heating input
6.2
kW
Sensible cooling
32900
Btuh
Heating output
21237
Btuh
Latentcooling
14100
Btuh
Temperature rise
12
OF
Total cooling
47000
Btuh
Actual airflow
1567
cfm
Actual airflow
1567
cfm
Airflowfactor
0.057
cfm/Btuh
Airflowfactor
0.047
cfm/Btuh
Static pressure
0
in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.76
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrigns -n 2021-Mar-2313:37:32
- ^'� - Riglt-Sate®Urrversal2021 21.0.05 RBU29964 Page 1
ACCA -,ser W=4rts\Wrigftso11 WACWSL-MYRTLE•40np Cale= WO Frort Door faces: E