HomeMy WebLinkAboutAPPROVED Plans 2
APPROVED E-1.0.pdf Model
NO.DATEDR REVISIONSCKAPP 315 South 7th Street Phone: 772 672-4636 Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173
Engineering, Inc. BEACH FRONT MANN REALTY BRENT A. WOOD ARCHITECTURE C. T I M O T H Y T R E W Y N R E E N I G N E L A N O I S S E F O R P L I C E N S E F L O R I D A No. 61580 STATE
OF
APPROVED E-1.1l.pdf Model
NO.DATEDR REVISIONSCKAPP 315 South 7th Street Phone: 772 672-4636 Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173
Engineering, Inc. BEACH FRONT MANN REALTY BRENT A. WOOD ARCHITECTURE C. T I M O T H Y T R E W Y N R E E N I G N E L A N O I S S E F O R P L I C E N S E F L O R I D A No. 61580 STATE
OF EXTERIOR LIGHTING SCHEDULE
APPROVED E-1.2.pdf Model
NO.DATEDR REVISIONSCKAPP 315 South 7th Street Phone: 772 672-4636 Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173
Engineering, Inc. BEACH FRONT MANN REALTY BRENT A. WOOD ARCHITECTURE C. T I M O T H Y T R E W Y N R E E N I G N E L A N O I S S E F O R P L I C E N S E F L O R I D A No. 61580 STATE
OF S S K-2035-8 PINOIR LAVATORY VITREOUS CHINA K-2035-8 PINOIR LAVATORY VITREOUS CHINA DW Photometrics Calculation Software Generated Luminaire Schedule Symbol Qty Label Arrangement
Lum. Lumens Arr. Lum. Lumens LLF Lum. Watts Arr. Watts 4 B SINGLE 938 938 0.900 9.9 9.9 2 F SINGLE 1635 1635 0.900 21.2 21.2 1 SA SINGLE 11268 11268 0.900 112 112 3 SW SINGLE 4123 4123
0.900 34 34 3 L SINGLE 903 903 0.900 9.76 9.76 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min ENTRANCE Illuminance Fc 5.58 10.5 1.1 5.07 9.55 PARKING LOT Illuminance
Fc 2.30 5.7 0.7 3.29 8.14 PROPERTY LINE Illuminance Fc 0.00 0.0 0.0 N.A. N.A. REAR ENTRANCE Illuminance Fc 4.91 9.5 2.2 2.23 4.32 SIDE EXIT Illuminance Fc 3.84 8.9 2.0 1.92 4.45 F MH:
7 F MH: 7 SA MH: 15 SW MH: 10 SW MH: 10 SW MH: 10 B MH: 7.16 B MH: 7.16 B MH: 7.16 B MH: 7.16 L MH: 0.1 L MH: 0.1 L MH: 0.1 1.5 1.7 1.8 1.7 1.1 3.1 3.1 2.8 2.7 2.7 3.0 3.6 3.6 3.3 3.3
3.6 4.4 3.3 3.4 3.3 3.4 3.7 4.5 6.2 7.2 9.8 10.1 7.6 4.5 3.4 5.1 8.2 10.4 9.5 6.5 3.9 3.7 6.2 9.2 10.5 8.7 5.5 3.5 4.3 7.2 9.9 10.0 7.3 4.0 2.8 3.0 3.0 3.1 3.4 4.0 5.7 7.2 10.0 10.2
7.5 4.6 3.5 5.1 8.2 10.3 9.4 6.5 3.9 3.8 6.2 9.2 10.4 8.6 5.5 3.6 4.3 7.2 9.8 9.9 7.3 4.0 0.8 1.5 2.2 2.3 2.1 2.1 2.3 2.0 1.1 1.6 0.7 1.3 2.0 2.8 3.4 3.4 2.8 1.8 1.1 1.0 0.8 1.4 2.3
3.1 4.2 4.6 3.1 2.3 1.4 0.9 0.7 1.7 2.9 3.9 5.3 5.7 3.8 3.1 1.8 0.8 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2.3 2.4 2.7 2.9 3.0 3.2 3.4 3.7 4.0 4.1 4.3 4.4 4.4 4.5 4.5 4.7 4.8 4.7 4.8 4.7 4.6 4.5 4.5 4.4 4.4 4.2 4.0 3.8 3.5 3.3 3.1 2.9 2.7 2.5 2.6
3.0 3.3 3.6 4.0 4.1 4.4 4.6 4.8 4.9 5.1 5.3 5.5 5.7 5.9 5.8 5.8 6.0 5.9 5.8 6.0 5.7 5.5 5.4 5.2 4.9 4.8 4.7 4.5 4.3 4.0 3.7 3.4 3.2 2.7 3.1 3.5 3.7 4.1 4.4 4.9 5.2 5.3 5.3 5.6 5.8 5.9
5.9 5.9 6.0 6.1 6.0 6.1 6.0 5.9 5.9 5.9 5.9 5.7 5.3 5.3 5.3 5.0 4.5 4.2 3.8 3.6 3.2 2.5 2.9 3.3 3.6 3.8 4.2 4.8 5.3 5.6 5.7 5.9 6.0 5.8 5.5 5.4 5.6 5.8 5.8 5.8 5.7 5.5 5.5 5.7 5.9 6.0
5.8 5.7 5.5 5.0 4.4 3.9 3.7 3.4 3.1 2.3 2.8 3.3 3.6 3.8 4.0 4.5 5.1 5.7 5.9 6.0 5.8 5.5 5.3 5.3 5.5 5.6 5.6 5.6 5.5 5.3 5.3 5.4 5.7 6.0 6.0 5.8 5.3 4.7 4.1 3.8 3.7 3.4 3.0 2.4 2.8 3.3
3.6 3.9 4.2 4.8 5.7 6.4 6.8 6.8 6.4 5.9 5.5 5.4 5.5 5.7 5.6 5.7 5.6 5.5 5.5 5.8 6.3 6.7 6.8 6.6 6.0 5.1 4.4 4.0 3.7 3.5 3.0 2.2 2.7 3.1 3.4 3.7 4.5 5.9 7.5 8.8 9.4 9.3 8.4 7.1 5.9 5.3
5.2 5.3 5.3 5.3 5.2 5.2 5.7 6.7 8.0 9.1 9.5 9.2 8.0 6.4 4.9 3.9 3.5 3.2 2.8 2.8 2.6 2.4 2.2 2.0 3.4 3.1 3.0 2.7 2.3 3.6 3.4 3.1 2.7 2.4 3.7 3.4 3.1 2.7 2.5 3.8 3.5 3.2 2.9 2.9 4.1 3.8
3.4 3.2 3.2 4.2 3.9 3.6 3.5 3.5 2.1 2.3 2.2 2.4 2.6 2.5 2.7 2.7 2.8 2.9 3.0 3.2 3.2 3.2 3.3 3.3 3.5 3.5 3.5 3.6 3.6 3.7 3.6 3.7 3.8 4.2 4.0 3.8 3.9 4.2 5.5 4.5 4.2 4.4 4.5 7.0 5.3 4.7
4.9 4.8 8.3 5.9 5.2 5.2 4.8 8.9 6.2 5.4 5.2 4.7 8.8 6.2 5.3 5.2 4.8 7.7 5.7 5.0 5.1 4.8 6.3 4.9 4.4 4.7 4.7 4.8 4.2 4.0 4.2 4.3 3.9 3.8 3.7 3.8 4.0 3.4 3.6 3.6 3.6 4.0 3.2 3.4 3.4 3.4
3.8 2.8 3.0 3.0 3.4 3.5 2.4 2.5 3.0 3.1 3.2 2.0 2.7 2.6 2.7 2.9 ´ ´ ´ ´ ´
APPROVED E-2l.pdf Model
101 WAITING 107 CONFERENCE 111 BREAK ROOM 112 JANITOR 110 REST ROOM 109 REST ROOM 113 WORK AREA 104 SMALL CONFERENCE ROOM 106 OFFICE 103 OFFICE REF 105 OFFICE 108 A/C COPY / FAX 102
RECPTION ARTWORK CENTERED ON CORRIDOR - I.D. SELECTED ARTWORK CENTERED IN ROOM - I.D. SELECTED TV TV TELEPHONE AND DATA NO.DATEDR REVISIONSCKAPP 315 South 7th Street Phone: 772 672-4636
Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173 Engineering, Inc. BEACH FRONT MANN REALTY BRENT A. WOOD ARCHITECTURE
C. T I M O T H Y T R E W Y N R E E N I G N E L A N O I S S E F O R P L I C E N S E F L O R I D A No. 61580 STATE OF SPRC SPRC RRR R SPRC SPRC R
APPROVED E-3.pdf Model
101 WAITING 107 CONFERENCE 111 BREAK ROOM 112 JANITOR 110 REST ROOM 109 REST ROOM 113 WORK AREA 104 SMALL CONFERENCE ROOM 106 OFFICE 103 OFFICE REF 105 OFFICE 108 A/C COPY / FAX 102
RECPTION ARTWORK CENTERED ON CORRIDOR - I.D. SELECTED ARTWORK CENTERED IN ROOM - I.D. SELECTED TV TV TELEPHONE AND DATA NO.DATEDR REVISIONSCKAPP 315 South 7th Street Phone: 772 672-4636
Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173 Engineering, Inc. BEACH FRONT MANN REALTY BRENT A. WOOD ARCHITECTURE
C. T I M O T H Y T R E W Y N R E E N I G N E L A N O I S S E F O R P L I C E N S E F L O R I D A No. 61580 STATE OF RCD SPRC OCC S S S RCD1,2 DT1-R SPRC OCC D1 D1 D1D1 RCD RCD SPRC
OCCSPRC D1LV R L L D1LV R L D1LV D1LV D1LV R L R L R L S RCD1,2 SRCD1,2 DT1-R DT1-RDT1-R DT1-R SYMBOL CONTROLS LEGEND MODEL/DESCRIPTION S RCD1,2 RCD SPRC-R-20-120 ROOM CONTROLLER RECEPTACLE
RATED SWITCHPACK SPRC OCC D1 à DT1-R R D1LV L S PPS-5 PPS-5
APPROVED E-4.pdf Model
NO.DATEDR REVISIONSCKAPP 315 South 7th Street Phone: 772 672-4636 Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173
Engineering, Inc. BEACH FRONT MANN REALTY BRENT A. WOOD ARCHITECTURE SCALE = (N.T.S.)B C. T I M O T H Y T R E W Y N R E E N I G N E L A N O I S S E F O R P L I C E N S E F L O R I D
A No. 61580 STATE OF DATA/COMM. STUB-UP DETAIL SCALE = (N.T.S.)A SCALE = (N.T.S.)EXISTING ELECTRICAL RISER DIAGRAM NEW ELECTRICAL RISER DIAGRAMC
APPROVED E-5.pdf Model
NO.DATEDR REVISIONSCKAPP 315 South 7th Street Phone: 772 672-4636 Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173
Engineering, Inc. BEACH FRONT MANN REALTY BRENT A. WOOD ARCHITECTURE C. T I M O T H Y T R E W Y N R E E N I G N E L A N O I S S E F O R P L I C E N S E F L O R I D A No. 61580 STATE
OF *Defaults to vacancy sensor mode Manual On/Automatic Off (all loads) for maximum energy savings 1 2 3 4 5 6 Integration ControlsAdjustable Skylights Low EndHigh End Energy Options
StatusReset 0-10V Gain Adjustment Dimmer 3 Dimmer 2 Dimmer 1 + - + + 0-10V Dimming 0-10V Dimming Outputs -+ Dimmer 3 Dimmer 2 Dimmer 1 -++ Blue - EM Line In Blue - EM Loads Out CAUTION:
Bonding between conduit connections is not automatic and must be provided as part of the installation. Black - Line In White/Black - 120V N White/Orange - 277V N Blue - Load In Yellow
- Load 1 Out Red - Load 2 Out Purple - Load 3 Out Energy Options DIP Switch Demand Response Occupancy Not Used 1 2 3 4 Default 10% 20% 30% 40% Occ Vac (default) Time Clock Alert Mode
Demand Response A/V Mode + Integration Controls + + + Green Black Red White Adjustable Skylights Sensors Receptacle BMS/Out Switchpack QuickConnect Cables Sensors Slider Station Wallstations
BLACK - Hot (120/277VAC) WHT/ORG or WHT/BLK Neutral BLUE - Relay In (120/277VAC) OCC-RJ45(Occupancy Coupler) Model: OCC-RJ45 Occupancy Sensor Coupler Brown Black Red Blue *Allows connection
to any Greengate Occupancy/Vacancy Sensor. LIGHTING LOAD (1) YELLOW RED *0-10V Dimming Zone Note: The 0-10V dimming zones within the Room Controller can be wired and controlled independent
of the connected loads. This allows a each load to have a dedicated 0-10V dimming zone or a single load to have up to three 0-10V dimming zones. Quick connect cables are pre-terminated
and included in the Room Controller QuicKit and measured to fit typical room layouts Gray - Dimmer 1 Gray - Dimmer 2 Violet - Dimmer 2 LIGHTING LOAD (2) SPRC-R-20-120 20A Receptacle
Control 120V receptacle circuit Receptacle Control: 20Amp 120VAC receptacle control immediately works upon power up and connection to the Room Controller. Receptacle turns On by button
press or occupancy and Off when space is vacant. The Room Controller connects up to five Receptacle Control Switchpacks for control of 20A receptacle circuits. CONFERENCE ROOM - ROOM
CONTROLLER DIAGRAM Violet - Dimmer 2 WAITING/RECEPTION - ROOM CONTROLLER DIAGRAM Connect up to four wallstations per Room Controller 1 2 3 4 5 6 Integration ControlsAdjustable Skylights
Low EndHigh End Energy Options StatusReset 0-10V Gain Adjustment Dimmer 3 Dimmer 2 Dimmer 1 + - + + 0-10V Dimming 0-10V Dimming Outputs -+ Dimmer 3 Dimmer 2 Dimmer 1 -++ Blue - EM Line
In Blue - EM Loads Out CAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation. Black - Line In White/Black - 120V N White/Orange
- 277V N Blue - Load In Yellow - Load 1 Out Red - Load 2 Out Purple - Load 3 Out Energy Options DIP Switch Demand Response Occupancy Not Used 1 2 3 4 Default 10% 20% 30% 40% Occ Vac
(default) Time Clock Alert Mode Demand Response A/V Mode + Integration Controls + + + Green Black Red White Adjustable Skylights Sensors Receptacle BMS/Out Switchpack QuickConnect Cables
Sensors Slider Station Wallstations BLACK - Hot (120/277VAC) WHT/ORG or WHT/BLK Neutral BLUE - Relay In (120/277VAC) LIGHTING LOAD (1) YELLOW RED Quick connect cables are pre-terminated
and included in the Room Controller QuicKit and measured to fit typical room layouts LIGHTING LOAD (2) *Defaults to vacancy sensor mode Manual On/Automatic Off (all loads) for maximum
energy savings OCC-RJ45 (Occupancy Coupler) Model: OCC-RJ45 Occupancy Sensor Coupler Brown Black Red Blue *Allows connection to any Greengate Occupancy/Vacancy Sensor. SPRC-R-20-120
20A Receptacle Control 120V receptacle circuit Receptacle Control: 20Amp 120VAC receptacle control immediately works upon power up and connection to the Room Controller. Receptacle
turns On by button press or occupancy and Off when space is vacant. *0-10V Dimming Zone Note: The 0-10V dimming zones within the Room Controller can be wired and controlled independent
of the connected loads. This allows a each load to have a dedicated 0-10V dimming zone or a single load to have up to three 0-10V dimming zones. Gray - Dimmer 1 Gray - Dimmer 3 Violet
- Dimmer 2 Violet - Dimmer 3 Violet - Dimmer 1 Gray - Dimmer 1 *Defaults to vacancy sensor mode Manual On/Automatic Off (all loads) for maximum energy savings 1 2 3 4 5 6 Integration
ControlsAdjustable Skylights Low EndHigh End Energy Options StatusReset 0-10V Gain Adjustment Dimmer 3 Dimmer 2 Dimmer 1 + - + + 0-10V Dimming 0-10V Dimming Outputs -+ Dimmer 3 Dimmer
2 Dimmer 1 -++ Blue - EM Line In Blue - EM Loads Out CAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation. Black - Line In
White/Black - 120V N White/Orange - 277V N Blue - Load In Yellow - Load 1 Out Red - Load 2 Out Purple - Load 3 Out Energy Options DIP Switch Demand Response Occupancy Not Used 1 2 3
4 Default 10% 20% 30% 40% Occ Vac (default) Time Clock Alert Mode Demand Response A/V Mode + Integration Controls + + + Green Black Red White Adjustable Skylights Sensors Receptacle
BMS/Out Switchpack QuickConnect Cables Sensors Slider Station Wallstations BLACK - Hot (120/277VAC) WHT/ORG or WHT/BLK Neutral BLUE - Relay In (120/277VAC) OCC-RJ45 (Occupancy Coupler)
Model: OCC-RJ45 Occupancy Sensor Coupler Brown Black Red Blue *Allows connection to any Greengate Occupancy/Vacancy Sensor. LIGHTING LOAD (1) YELLOW RED *0-10V Dimming Zone Note: The
0-10V dimming zones within the Room Controller can be wired and controlled independent of the connected loads. This allows a each load to have a dedicated 0-10V dimming zone or a single
load to have up to three 0-10V dimming zones. Quick connect cables are pre-terminated and included in the Room Controller QuicKit and measured to fit typical room layouts LIGHTING LOAD
(2) SPRC-R-20-120 20A Receptacle Control 120V receptacle circuit Receptacle Control: 20Amp 120VAC receptacle control immediately works upon power up and connection to the Room Controller.
Receptacle turns On by button press or occupancy and Off when space is vacant. The Room Controller connects up to five Receptacle Control Switchpacks for control of 20A receptacle circuits.
CONFERENCE ROOM - ROOM CONTROLLER DIAGRAM Gray - Dimmer 1 Gray - Dimmer 2 Violet - Dimmer 1 Violet - Dimmer 2 Relay Panel with 8 latching relays and astronomical timeclock SYMBOL CONTROLS
LEGEND MODEL/DESCRIPTION S RCD1,2 RCD SPRC-R-20-120 ROOM CONTROLLER RECEPTACLE RATED SWITCHPACK SPRC OCC D1 à DT1-R R D1LV L S PPS-5 1 2 3 Notes Refer to plans for locations, size,
and quantity. Refer to all manufacturers installation instructions for correct wiring information This one-line drawing is for concept only. Every wire is not shown. Wire according
to the product installation/wiring instructions. Cables LV3 Low Voltage Input wire - #18 AWG, 3 conductor wire PPS-5 P2-17 P2-17 P2-17 P2-19 S RCD1,2 S S R R DT1-R DT1-R R S RCD1,2
ROOM CONTROLLER SYSTEM NOTES LK8-LRC Relay Panel with 8 latching relays and astronomical timeclock
APPROVED EX-1.00.pdf \\DLINK-697F18\Volume_1\Volume_1\Projects\2020\220059 Beach Front Mann Realty\Construction\220059_EX-100.dwg Layout1 (1)
APPROVED EX-1.11.pdf \\DLINK-697F18\Volume_1\Volume_1\Projects\2020\220059 Beach Front Mann Realty\Construction\220059_EX-111.dwg Layout1 (1)
APPROVED EX-1.21.pdf \\DLINK-697F18\Volume_1\Volume_1\Projects\2020\220059 Beach Front Mann Realty\Construction\220059_EX-121.dwg Layout1 (1)
APPROVED EX-2.01.pdf \\DLINK-697F18\Volume_1\Volume_1\Projects\2020\220059 Beach Front Mann Realty\Construction\220059_EX-201.dwg Layout1 (1)
APPROVED GN-1.pdf \\DLINK-697F18\Volume_1\Volume_1\Projects\2020\220059 Beach Front Mann Realty\Construction\220059_GN-1.dwg Layout1 (1)
APPROVED L-1.pdf D:\Conceptual\2021\21-0102 Mann Commercial\Landscape\Submittal 2\21-0102 Mann Commercial LP 3-30-2021 Layout1 (1)
APPROVED L-2.pdf D:\Conceptual\2021\21-0102 Mann Commercial\Landscape\Submittal 2\21-0102 Mann Commercial LP 3-30-2021 Layout2 (1)
APPROVED LP 1-26-2021 Sheet L-1 of 2.pdf D:\Conceptual\2021\21-0102 Mann Commercial\Landscape\Submittal 1\21-0102 Mann Commercial LP 1-26-2021 Layout1 (1)
APPROVED LP 1-26-2021 Sheet L-2 of 2.pdf D:\Conceptual\2021\21-0102 Mann Commercial\Landscape\Submittal 1\21-0102 Mann Commercial LP 1-26-2021 Layout2 (1)
APPROVED LS-1.11.pdf \\DLINK-697F18\Volume_1\Volume_1\Projects\2020\220059 Beach Front Mann Realty\Construction\220059_LS-111.dwg Layout1 (1)