HomeMy WebLinkAboutupdated plansL 121'-0"
UNIT 315 (UNIT
1
BALCONY PLAN
EX15T ALUM RAILING TO REMAIN
N.T.5.
EX15T ALUM RAILING TO REMAIN
UNIT 415 (UNIT 315 CLG) - BALCONY PLAN
N.T.5.
;mull
r:i :_r
EX15T ALUM RAILING TO REMAIN
121'-0"
UNIT 515 (UNIT 415 CLG) - BALCONY PLAN
N.T.S.
PARTIAL DEPTH SURFACE 5PALL
TO BE REPAIRED
EX15T ALUM RAILING TO REMAIN
121'-O"
UNIT 615 (UNIT 515 CLG) - BALCONY PLAN
N.T.S.
UNIT 811 - BALCONY PLAN
GEILIN6 5PALL TO BE
REPAIRED, SEE NOTES
POWER TOOL GLEAN 4 COAT
EXIST REINF BAR A5 PER
SPECS
SECTION
BALCONY EDGE ® ROOF SLAB
TO BE REPAIRED
EX15T HURRICANE 5HATER5 TO BE
REMOVED d RE -INSTALLED
AS REOV TO REPAIR BALCONY E06E
EX15T ALUM RAILIN6 TO REMAIN
N.T.5.
EX15T b" GMU PARAPET WALL
TO REMAIN
EXIST 14" THICK GONG ROOF SLAB
SEE SHORING DIAGRAM
N.T.5.
NOTE:
I. SHORE BALCONY EDGE A5 PER SNORING DIAGRAM
2. REPAIR E06E IN 2'-0" SECTIONS
SLAB EDGE TO
BE REPAIRED
1/2" PLWYD 4 2x6
FORM BOARDS
5IEGTI ELEVATION
SHORING DIAGRAM
NOTES: N.T.5.
I. P05T SHORES TOP AND BASE PLATES SHALL BE SECURED WITH (4) 1/4" x3" HD 5GREW5
OR TAPGON5 A5 APPLICABLE.
2. 5EQUENGE WORK TO REPAIR d SHORE ALTERNATE BALCONIES.
SURFACE PREPARATION
I. HORIZONTAL 5URFACE5
A. CHIP OUT L005E CONCRETE WITHIN THE MARKED AREAS AND DETERMINE DEPTH OF REINFORGIN6
STEEL. SAW CUT AROUND PERIMETER OF THE REPAIR IN A RE6TAN6ULAR PATTERN TO A DEPTH OF A
I/2 INCH OR LE55 TO AVOID CUTTING THE STEEL.
B. REMOVE THE CONCRETE WITHIN THE SAW CUT AREA WITH HAND CHIPPER TO EXP05E THE CORRODED
REINFORGIN67 STEEL AND TO REMOVE FRACTURED OR UNSOUND CONCRETE IN ACCORDANCE WITH
THE RECOMMENDATIONS FROM "IGRI".
CHIP SURFACES TO OBTAIN A SURFACE ROU&HNE55 PROFILE OF 1/6 INCH 01/Ib). WHERE ACTIVE BAR
CORP05ION 15 FOUND CONTINIE GHIPPIN5 TO A DEPTH OF 3/4 INCH MIN CLEARANCE BELOW
CORRODED BARS. MAKE ADDITIONAL SAW CUTS AND CHIP AS REQUIRED TO EXPAND THE REPAIR
AREA EFFECTIVELY "CHASE" THE CORROSION FOR APPROXIMATELY b INCHES BEYOND ALL ACTIVE
CORROSION.
WHERE BAR COW05ION 15 LIMITED TO NORMAL MILL SCALE AND SURFACE OXIDATION AND LE55
THAN 1/2 OF THE BAR DIAMETER 15 EXP05FD WITH REMAININ6 GONGRETE FULLY BONDED,
UNDERGUTTIN6 THE BAR 15 NOT REQUIRED.
IF THE EXTENT OF CONCRETE DAMAGE EXTEN05 BEYOND THE ESTIMATED AREA, NOTIFY THE OWNER
OR EN61NEER BEFORE PROGEEDIN6.
2. VERTICAL AND OVERHEAD 5URFAGE5
A. VERTICAL AND OVERHEAD SURFACES SHALL BE PREPARED IN A 51MILAR MANNER TO HORIZONTAL
9URFAGE5 DE56RI13ED IN PLAN. THE GONTRAGTOR SHALL VERIFY THE AMOUNT OF CONCRETE COVER
OVER REINFORGIN6 STEEL AND SHALL REDUCE THE DEPTH OF 5AWOUTTIN5 AGGORDIN15LY TO AVOID
GUTTING ANY 13AR5.
3. IMMEDIATELY AFTER CLEANIN6 AND REPLACEMENT OF REINFORGI% STEEL, APPLY TWO GOATS OF
CORROSION INHIBITOR PER MANUFACTURER5 SPECIFICATIONS.
CONCRETE PLACEMENT
I. INSTALL FORMWORK AS REQUIRED FOR E06E AND FULL DEPTH REPAIRS. FORMWORK SHALL BE SHORED A5
NEGE55ARY AND FORMS SHALL REMAIN IN PLACE A MINIMUM OF 14 DAYS.
2.1300 THE REPAIR MATERIAL TO THE PREPARED AREA WITH ONE OF THE FOLLOWIN6 METHODS.
A. APPLY BONDING A6ENT TO THE PREPARED GONGRETE SURFACE AGGORDIN6 TO THE MANUFACTURERS
INSTRUCTIONS.
B. PRESOAK SUBSTRATE TO A SATURATED SURFACE DRY CONDITION WITH NO 5TANDIN6 WATER. APPLY A
SLURRY BOND GOAT OF THE REPAIR MATERIAL TO THE PREPARED AREA WITH A STIFF BRI5TLE BRUSH
OR BROOM. DO NOT ALLOW THE SLURRY TO DRY PRIOR TO INSTALLATION OF THE REPAIR MATERIAL.
DO NOT RETEMPER THI5 BOND COAT.
3. MEGHANIGAL MIXIN6 15 RECOMMENDED WITH THE USE OF A SLOW SPEED DRILL AND A JIFFLER TYPE
PADDLE, OR IN AN APPROPRIATE MORTAR MIXER. TYPICAL MIXIN6 TIME 15 3-5 MINUTES. DO NOT ADD MORE
WATER THAN 15 RECOMMENDED BY THE MANUFAGTURER. DO NOT MIX LONGER THAN 5 MINUTES. ONLY THAT
PORTION OF MATERIAL THAT GAN BE PROPERLY MIXED WITHIN 10 MINUTES OF APPLICATION SHOULD BE
MIXED.
4. APPLY FRESH MORTAR OR READY MIX CONCRETE TO THE BOND COAT. PLACE REPAIR MORTAR ACGORDIN6
TO MANUFACTURERS RECOMMENDATION5.
5. EVAPORATION RETARDER: WHERE RAPID SURFACE EVAPORATION MAY OCCUR, IN HOT, WINDY CONDITIONS,
APPLY SPECIFIED EVAPORATION RETARDER AGGORDIN6 TO MANUFACTURERS RECOMMENDATIONS.
6. FINI5HIN6: COMPLETED REPAIR 5URFAGE5 SHOULD BE 5TRA16HT, TRUE AND MATCH EXISTING PROFILES.
DO NOT OVER WORK THE 5URFAGE.
1. AFTER APPLICATION 15 COMPLETED AND REPAIR MATERIAL HAS SUFFIGIENTLY SET 50 RE50UNDIN6 WILL
NOT DAMAGE IT, RE50M PATCHED AREA TO INSURE PROPER BONDING OF THE REPAIR MATERIAL.
6. ALL REPAIRED SURFACES MUST BE GURED FOR A MINIMUM OF 5 DAYS
REINFORGIN6 PIYPJ
GUT PARALLEL OR
PERPENDICULAR TO
SLAB E06E5 d WALLS
_SLAB IN PLAN
N.T.5.
TYP.. ISLAND
0/0
AVOID PREFERRED
AVOID COMPLEX REPAIR CONFI6URATION5, 51MPLIFY SHAPES
AND ELIMINATE ISLANDS
SURFACE PREPARATION GEOMETRY
N.T.5.
EX15T REINF. TO REMAIN
5PALLIN6 AREA TO BE REPAIRED
REMOVE FULL DEPTH OF GONG, LEAVING EX15T REINF
POWER TOOL GLEAN d PAINT ALL EX15T BARS
EXPOSE A MIN. OF 6'
OF NON -CORRODED REINF.
SAW GUT AROUND PERIMETER OF REPAIR
AREA t ROUGHEN E06E5
FULL OR PARTIAL DEPTH SLAB REPAIR
N.T.5.
KEY PLAN
DESIGN CRITERIA
FLORIDA BUILDIN6 GORE, ITH EDITION (2020) - EXI5TIN6 BUILDIN65
ROOF LOADS
DEAD.......................................................................................20
P5F
LIVE..........................................................................................20
P5F
FLOOR LOADS
DEAD
GONGRETE 5LA13 ...........................................................150
PGF
LIVE
BALCONIES......................................................................b0
P5F
PE546N CRITERIA PER A5GE I-Ib
ULTIMATE Y;iND SPEED RE610N, *10......................110
MPH
NOMINAL WIND SPEED RE610N, V(aed)....................132
MPH
WIND BORNE DEBRIS RE61ON
ENGLO5ED STRUCTURE
BUILDIN6 HEIGHT
< 140 FT
ROOF PITCH
FLAT < I°
R15K GA1 CcORY
11
INTERNAL PiwF55URE GOEFF.
10.16
EXPOSURE
D
N.T.5.
U�
Z
�
0,
V
W
:3
N
M
1,
>
-
Q
O'
LU*-
U
L�
Ny
eM
U
z
0)
o
N
W
C
p
m
t
CV
O
€d�
N
`!
j:
C
O
RECEIVED
MAY ) 3 701t
Permitting Department
St. Lucie county
SCANNED
SCOPE OF WORK
I. THE SCOPE OF WORK 15 LIMITED TO THE GENERAL CONCRETE REPAIRS TO THE EAST FAGIN6 BALGONIE5
® UNITS 215/315, 31D/415, 415/515, 515/615 4 611.
STRUCTURAL NOTES
I. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND NOTIFY THE EN61NEER OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
2. ALL CONSTRUCTION SHALL BE BRACED AND SHORED BY THE CONTRACTOR AS REQUIRED TO SAFELY
PERFORM THE WORK.
CONCRETE
I. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE FOLLOWING:
A.G.I. 301 'SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" LATEST EDITION.
A.G.I. 316 BUILDING CODE REQUIREMENT5 FOR STRUCTURAL CONGRETE.
I.G.R.I. "INTERNATIONAL CONCRETE REPAIR INSTITUTE" LATEST EDITION.
2. THE MINIMUM CONCRETE GOVERACE5 SHALL BE AS FOLLOWS:
EXP05ED TO WEATHER 1 112" MIN.
3. PROVIDE qO DE6REE LAP SPLICES AT ALL INTERSECTIONS.
4. REINFORGIN6 SHALL BE LAPPED SPLICED AND TIED WITH THE FOLLOWING MINIMUM:
#4 241N5 #5 301N5 #b 361N5
CONCRETE REPAIRS
I. 5AWGUT AROUND THE PERIMETER OF THE AREA TO BE REPAIRED IN A REGTAN6ULAR PATTERN. GUTS SHALL
BE MADE PARALLEL OR PERPENDIGULAR TO THE SLAB E06E5 A5 PER THE DETAILS SHOWN. DO NOT CUT ANY
EXI5TIN6 REINFORGIN6 STEEL. IF STEEL 15 ENCOUNTERED REDUCE THE DEPTH OF CUT AS REQUIRED.
2. REMOVE ALL FRACTURED, L005E 4 UN50UND CONCRETE. CHIP SURFACES TO OBTAIN A 5URFAGE ROU6HNE55
OF 1/4" 4 109 PREPARE THE AREA 50 THAT THE SIDES ARE VERTICAL AND LEVEL.
3. WHERE ACTIVE CORROSION 15 FOUND, CONTINUE CHIPPING TO A DEPTH OF 3/4" AROUND REINFORCING
4. IF ACTIVE CORROSION OR UNSOUND OR FRACTURED CONCRETE EXTENDS BEYOND THE SAW GUT AREA,
EXTEND THE REPAIR. AREA AS REQUIRED TO INCLUDE ALL ACTIVE CORROSION 4 UNSOUND CONCRETE.
5. EXI5TIN5 REINF. BARS SHALL BE POWER TOOL GLEANED OF ALL SCALE 4 RUST. BARS ARE TO BE REPLAGED
IF EXHIBITS 6REATER THAN A 20% L055 OF 6RO55 SECTION WITH A BAR OF SAME 51ZE AND LAP OF 35 BAR
DIAM OR IF LAP 5PLIGIN6 15 NOT P0551BLE A DOWEL OF SAME 51ZE SHALL BE EPDXY ANCHORED TO A
DEPTH OF 12 BAR DIAM.
b. ALL EXI5TIN6 REINFORGING STEEL WHICH CAN BE REMOVED BY HAND AFTER CONCRETE DEMOLITION 15
COMPLETED SHALL BE REPLACED WITH NEW BAR5 OF SAME DIAMETER 4 5PAGIN6 A5 THE ORIGINAL STEEL.
1. WHERE REPLACEMENT 15 NECESSARY THE EXISTING REINFORGIN6 STEEL SHALL BE GUT LEAVING A MINIMUM OF
35 BAR DIAMETERS EXTENDIN6 OUT FROM THE SOUND CONCRETE TO ALLOW FOR LAP 5PLIGIN6 OF NEW
REINFORCEMENT.
6. WHEN DOWELIN6 NEW BARS NEXT TO EXI5TIN6 BARS, HOLES SHALL BE DRILLED A MIN. OF 2' APART FROM
THE EXISTING BARS. CARE SHALL BE TAKEN TO DRILL PARALLEL TO THE EXI5TIN5 STEEL TO PREVENT
5PALLIN6 OF THE CONCRETE. DRILLED HOLES SHALL BE PER THE FASTENER MANUFACTURERS
5PEGIFIGATION5 AND FILLED WITH EPDXY. NEW DOWELS SHALL BE INSERTED TO THE FULL DEPTH.
q. COAT ALL EXP05ED REINF BARS WITH CORROSION INHIBITOR PRIOR TO PLAGIN6 NEW CONCRETE.
10. CONCRETE REPAIR PRODUCTS SHALL BE AS PER 5PEG.5
11. ALL CONCRETE DEMOLITION SHALL BE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE INTERNATIONAL
CONCRETE REPAIR INSTITUTE
CONCRETE REPAIR PRODUCTS
1. CONCRETE REPAIR MATERIALS 514ALL BE MANUFACTURED BY 51KA. ALL PROPRIETARY MATERIALS SHALL BE
APPLIED IN 5TRIGT AGGORDANGE WITH THE MANUFACTURERS SPECIFICATIONS. WHERE THE MANUFACTURERS
INSTRUCTIONS CONFLICT WITH THI5 SPECIFICATION, THE CONTRACTOR SHALL BRIN6 SUCH CONFLICTS TO THE
ATTENTION OF THE OWNER PRIOR TO THE APPLICATION. ALL MATERIAL SHALL BE FROM A SINGLE
MANUFACTURER. TO ASSURE COMPATIBILITY, MIXING AND MATGHIN6 OF VARIOUS PRODUCTS FROM DIFFERENT
MANUFAGTURER5 15 NOT ALLOWED WITHOUT PRIOR APPROVAL.
2. THE FOLLOWING PRODUCTS SHALL BE USED AS DESCRIBED IN TH15 SPECIFICATION.
STRUCTURAL REPAIR MORTARS:
A. HORIZONTAL d VERTICAL SURFACES: 51KA 211 5GG PLUS
B. C-ORRO510M INHIBITOR: 51KA ARMATEG 110 EPOGEM
G. BONDIN6 A6ENT: 51KA ARMATEG 110 EPOGEM
D. WATERPROOFING:
a. BASE GOAT - 51KA6ARD FLEXCOAT (2) COMPONENT, POLYMER -MODIFIED, WATERPROOF,
CEMENT BASED GOATIN6 SYSTEM
b. TOP GOAT - 51KA6ARD FLEXCOAT ATG 51N6LE COMPONENT, WATER -BASED, ACRYLIC.
c. COLOR AND TEXTURE TO MAT( N EXISTING SURROUNDING AREAS.
3. STUCCO REPAIR SHALL BE A MIN. TWO COAT MA50NRY GEMENT/5AND MIXTURE AT 1:3 RATIO IN ACCORDANCE
WITH THE PORTLAND CEMENT A550GIATION "PORTLAND CEMENT (5TUCW) MANUAL.
A. PORTLAND CEMENT IN ACCORDANCE WITH A5TM G15
B. MA50NPY GEMENT IN AGCORDANCE WITH A51-M Gql RECEIVED
G. ALL E06E5 SHALL BE HAND STRUCK WITH NO METAL BEADS
MAY 11 1021
':rrnittieg Departmesr
Coui�-
:s:
This drawing and design as shown Is
the property of ML Engineering, Inc.
Reproduction and/or use of this drawing
or any content therein, without express
consent or permission of this company
Is prohibited, may constitute an Infringe-
ment, and may be subject to legal action
by MIL Engineering. Inc.
H Q
0
O noo
z
J
O `L
m LU
Q (�
W
Z P Cn
Q M1- z
LUW
U
® d6i d
�O U
(J� 1 LU
LO cn
r
C V
W Cn
Z
�zQ
LU
I- v
MZO z
z z ®� O
O = `'
U CoLo m
w
m2 w
Oa
�Z
REVISIONS: DATE:
1Q UNIT NUMBERS 5-10-21
ISSUE: DATE:
FOR PERMIT 3-9-21
DATE:
3-9-21
DRAWN BY:
jR
CHECKED BY:
INIL
JOB No.
20-249A
MICHAEL A. LUE, P.E.
FLORIDA REG. #47520
SHEET NO:
Sill1
OF SHEET I