Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED design pressure calcs
PARADISE EXTERIOR." "Building our Qualify Reputation One Customer- At A Time„ Property Information Owner: VALERIE BRYAN-WUNNER Address: 8907 5 INDIAN RIVER DR FORT PIERCE, FL 34982 SCC131150472 ildinv Information Wind Zone: 170 MPH. Exposure Category: C Minimum Building Dimension: 22 ft. ..Mean Roof Height: 12 ft, Risk Category: II Design Pressure Calculations - - ©pe€ung -Loeatioll Device i, Devicej Device ' Max Posits e Max Negative Nu�nUe Width (in) Hei ht i►i !! Elevation ��€ ..._._J g ( )� (ft) Pressure (pst)� Pressure (pst) 1 Int 36 49 7 37.3 -40.5 2 Int 36 _ 49 7 37.3 -40.5 3 Int 36 49 7 37.3 -40.5 4 Int 35 49 7 37.4 -40.6 5 Int 35 49 7 37.4 -40.6 6 Int 34 49 7 37.4 -40.6 7 Int 36 49 7 37.3 40, 5 8 End 36 49 7 37.3 -49.6 _... _. 9 End ..... 35 49 7 37.4 -49.7 10 End 17 49 -.-.._... 7 37.8 -50.6 11 End 35 49 7 37.4 -49.7 12 End - 35 49 7 37.4 -49.7 13 End 35 49 7 37.4 49.7 14 Int 35 49 7 37.4 -40.6 15 Int 35 24 7 37.8 -41.0 I 16 Int 35 25 7 37.8 -41.0 17 Int 36 24 7 37.8 - -41.0 18 Int 36 61 7 36.8 -40.0 19 End 36 61 7 36.8 -48.5 20 End 36 61 7 36.8 -48.5 21 Int 36 61 7 36.8 -40.0 22 111t 36 61 7 36.8 -40.0 Prepared in accardance with: ASCE 7-16, Clrapler 30. Wind Loads - Cmnponeniv and Cladding. 7tli Edition (2020) Florida tluilding Code. Page 1 of 1