HomeMy WebLinkAboutCompactionTest Information
Test #Test Location Elevation Reference
Gauge
Make / Model / SN / Calibrated Field Technician
65 Below Slab Grade: 5194 Tree Top Trail, Ft Pierce Foundation Pad, E Section 0-1 Troxler / 3430/36487 / 36487 /
7/27/2020
Smith, Johnnie
66 Below Slab Grade: 5194 Tree Top Trail, Ft Pierce Foundation Pad, W Section 0-1 Troxler / 3430/36487 / 36487 /
7/27/2020
Smith, Johnnie
67 Below Slab Grade: 5194 Tree Top Trail, Ft Pierce Foundation Pad, Center 0-1 Troxler / 3430/36487 / 36487 /
7/27/2020
Smith, Johnnie
Remarks
Pass: Tests results comply with specifications
Comments
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
¶HCP=50+, > 95 % Compaction, PASS.
HCP tests are empirically correlated to the relative density of the soil.
Test Results
Test #
Retest
Of Test Date Proctor ID Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry
Density (pcf)
In Place
Moisture
(%)
In Place
Dry
Density
(pcf)
In Place
Wet
Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
(%)Remark
65 4/19/21 9184 - LBR N/A 10.9 114.6 11.3 112.5 125.2 12 98 98 / 105 Pass
66 4/19/21 9184 - LBR N/A 10.9 114.6 10.9 112.5 124.8 12 98 98 / 105 Pass
67 4/19/21 9184 - LBR N/A 10.9 114.6 11.4 112.9 125.8 12 99 98 / 105 Pass
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1
Soil Nuclear Gauge
Test Method: ASTM D 6938
Report Date: 5/14/2021
Client:
Environmental Land Development, Inc.
Fort Pierce, FL 34945
201 Campbell Road
Project:
Environmental Land Development 2018-2019
18-9980.00
FL
Various Locations
FBPE CA # 4930
607 NW Commodity Cove
Port St. Lucie, FL 34986
Phone: 772-924-3575 | Fax: 772-924-3580
Port St. Lucie