HomeMy WebLinkAboutAPPROVED POA 8114=21 Florida Building Code Online
r
BCIS Home ; Log In ! uW Registratlon Hot 7hpra' Submit Surcharge Stats & Facts pvblicaaons Contact Us ' BOS Site Map' . !Inks search
ProdiictApproval
Or a Ugrrt! oubtre U—
Prod > FroduG(or pQpl�tion Search > App&qkqn ig > Apptteatlon Octal!
l N: FL # FL389-R10
Application type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer American Shutter Systems Association, Inc.
Address/Phone/Email 4268 Westroads Drive
West Paim Beach, FL 33407
(561)209-8263
tifeeley@eastemmetal.com
Authorized Signature Bill Feeley
Trod riguezOeasternmeta€.corn
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Sukategory Accordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Walter A.. Tillit, Jr. P.E.
Evaluation Report
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2021
Validated By ' John Henry Karnprnann Jr.
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
certified By
Validation Checklist - Hardcopy Received
5LN2 R-10 C0I COI ASSA B_ LApE1,_tpf
FL3 RIO, Cj0I C I AS A LADE1 2. df
,FELML R1A COI CbI A53A BIA2U Pdf
Standard
ASTM E-1886
ASTM E-1996
ASTM E-330
7AS 201, 202, 203
2012
2012
2002
1994
Sections from the Code
114=21
Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
10/15/2020
Date Validated
11/06/2020
Date Pending FBC Approval
11/06/2020
t?at- Approved
12/15/2020
SummaDE of Products
FL #
Model, Number or Name
Description
389.1
Bertha HV Accordion Shutter - Blade
Extruded aluminum interlocking blades retained by tracks (top
3 - (Non-HVHZ) - Drwg 20-165
and bottom) for storm protection
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
EL389_R10 11 DRWING ASSA BLADES-pd
Approved for use outside HVHZ: Yes
Verified By: American Test Lab of South Florida, Inc.
Impact Rexistaint: Yes
Created by Independent Third Party: Yes
Design Pressure.- N/A
Evaluation Reports
Other: Large Missile Level "D".Max span is 12'-3" for 40 psf
Fi.389 R3_Q AE PE_R_SQjA RL81)Q.pdf
positive ASO load and I3'-0" for 35 psf negative ASO load the
Created by Independent Third Party: Yes
HV3 Made w/o window blade,5 =2" for 110 psf ASD load for
HV3 blade w/o window blade and 8'-11" for 62 psf, 9'-11" for
55 psf HV3 blade w/window blade working in unfson.Max.span
for HV3 blade w/o window blade for installations Into Metal
Stud walls is 791 for max. ASO pressure rating of +72,-72 and
84" for +64; 64 psf. See sheet 5 for other spans and ASD
pressures.
389.2
Bertha HV Accordion ShutterBlade 1
Extruded aluminum interlocking blades retained by tracks (top
Only- (Non-HVHZ)- Drwg 20-164
and bottom) for storm protection
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
F DE1. df
Approved for use outside HVHZ: Yes
Verified By: American Test Lab of South Florida, Inc.
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Large missile level "D". Max. Span is 16'-0" for 30 p.s.f
FL3? R1Q AE PER ASSA_BLADEj.Rdf
negative ASD load depending on centermates and locking rod
Created by Independent Third Party: Yes
configuration for the HV1 blade, 8'-0" for +64, -72 p.s.f. A.S.D.
load for HV biade for Keystone mountings 7'-0" p.s.f. for metals
stud mountings and 8'-0" for 110 p.s.f. for HV1A working In
unison. See sheets 7, 11 and 20 respectively of installation
drawings for other spans and pressures.
3 9.3
Bertha HV Accordion Shutter-
Extruded aluminum Interlocking blades retained by tracks (top
COMBO- (Non-HvHz)- Drwg 20-153
and bottom) for storm protection
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL3§g RIO 11 DPW ASSA B pE1 df
Approved for use outside HVHZ: Yes
Verified By: American Test Lab of South Florida, Inc.
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Large missile. Max. 16'-0" spar, at 30 p.s.f ASD load
FL3s9 Rio AE PER ASSA_BLADE1 2-121f
for Blade 1 and W-0" for Blade 2. See schedules on sheet 12,
Created by Independent Third Party: Yes
25 and 28 respectively
•� 0
Cang�1 ,: 2601 91a1r Stone Road. Tallahamc 11 ZZ399 Eh411:=L-02-1U4
The State of Flodda is an AA/EW employer. :: :. AccMiblity 2=20 :: Behind StatBrrleflt
Under Florida law, emall addresses are public records. jr you do not want your e-mall address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. if you have arry questions, please contact 850.487.1395. 'Pursuant to section 455.275(1),
Florida Statutes, eflaetive October 1, 2012, licensees 11eensed under Chapter 455, F.S. must provide the Depa=ent wlrh an emall address if they have one. The ernAls
provided may be used ror offlelal communication with the acensee. However emall addresses are public rmnrd. If you do not wish to supply a personal address, ph:asc
provide the Department mth an emarr address which can be made avallable to the public. To determine if you are a Ucenme under Chapter 45.5, F.5., please dick JgLr,-
Product Approval Accepts:
Credit Card
Safe