Loading...
HomeMy WebLinkAboutAPPROVED Deegan-Soprema Lastobond Smooth Seal HT-FL Approvals.pdfElp0i'llYllil Florida Building Code Online Business & Professional 1 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search db' prw 1.115W Approval Public User ProdUCtApprovaS Menu > Product or Application Sea_rLh > Application List > Application Detail FL # FL2569-R21 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer 5oprema, Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville, NON -US 00000 (819)478-2400 memathieu@soprema.ca Authorized Signature Marc -Etienne Mathieu memathieu@soprema.ca Technical Representative Marc -Etienne Mathieu Address/Phone/Email 1688 lean-Berchmans-Michaud Drummondville, NON -US 00000 (819)478-2400 Ext3327 memathieu@soprema.ca Quality Assurance Representative lean -Francois Cote, Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888)811-3145 jfcote@soprema.ca Category Roofing Subcategory Undedayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert 1. M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12121/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL2569 R21 COI 2020 Q1 COIN MINEN.pdf Referenced Standard and Year (of Standard) Standard Yg�� ASTM D1970 2015 ASTM D4798 2011 ASTM D6163 2015 FM 4474 2011 FRSA/TR1 Sixth Edition 2018 UL 1897 2015 https:llwww.floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB108Erx1 Ud3xYlzoPso9Gl4itVgZ9SrxpeDg%3d%3d 1/2 E9100➢il Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/16/2020 Date Validated 12/17/2020 Date Pending FBC Approval 12/26/2020 Date Approved 02/09/2021 Date Revised 04/19/2021 FL i Model, Number or Name Description 2569.1 Soprema Roof Underlayments Urns of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-150 Other: 1.) Refer to ER Section 5 for Umits of Use. 2.) The design pressure noted herein pertains to underiayment systems used beneath adhesive -set the systems. Refer to ER Section 5.8.3 for details. Self adhering roof underlayments Installation Instructions FL2569 R21 II 2020 12 16 FINAL ER SOPREMA FL2569- R21.gdf Verified By: Robert Nleminen, P.E. PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL2569 R21 AE 2020 12 16 FINAL ER SOPREMA FL2569- R21.pdf Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Roatl Tallahasate FL 32399 Phone: 850<87.1824 The State of Florida Is an A VEEO employer. CovyhQht 2007-2013 State of Florida.:: Privacv Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your! -mall address released In response to a public -records request, do not send electronic mall to Mls entity. Instead, contact We office by phone or by traditional mall. If you have any questions, please contact 1150.487.1395. 'Pursuant to section 455.275(1), Flonte statutes, enecdve October 1, 2012, licensees licensed under chapter 455, F.S. must provide Me Depart man win an email address If May have one. The emalls provided may be used for official communication win the licensee. However email addresses are public record If you do not wish to supply a personal address, please provide the Department win an email address which can be made available to Me public To determine If you are a licensee under Chapter 455, Fs., please click bri£. Product Approval Accepts: MWIFMEtlm Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dfl.aspx?param= GEVXQwtDgsKQFEnckB108Erx1Ud3xYlzoPso9Gl4ltVgZ9SrxpeDg%3d%3d 212 0 ENGINEER EVALUATE Soprema, Inc. 1640 rue Haggerty Drummondville, Quebec 12C 5PS Canada (819)479-2400 NEMO l etc. Certificate of Authorization a32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 TEST CONSULT Evaluation Report S18030.06.09-R19 FL2569-R21 Date of Issuance:06/15/2009 Revision 19:12/16/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7dt Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: 5oprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED CoMPuANcE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADvERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO) etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request Of the Building Official. This Evaluation Report consists of pages 1 through 9 Prepared by:If Robert J.M. Nieminen, P.E. :-t j;T=° The facsimile seal appearing was authorized by Robert ��3•^•'� Florida Registration No. 59166, Florida DCA ANE1983 " Nieminen, P.E. on 12/16/2020. This does not serve as ''a,,: '.,; ; an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEW ETC, LLC NNEMOletc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Soprema Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the r Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Prope Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.3.1 Wind resistance UL 1897 2015 1507.1.1, 1507.2.4, 1507.2.9.2 Material standard ASTM D1970 2015 / R905.1.1, R905.2.8.2 1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 1507.11.2/ R905.11.2 Material standard ASTM D6163 2015 TAS 110 Accelerated Weathering ASTM D4798 2011 Entitif Examination Reference Date ERD (TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD (TST6049) ASTM D1970 / TAS 110 (QC) S31370.03.10-1-R1 04/07/2010 ERD (TST6049) FRSA/TRI 04-12 (OH) 511150.05.09-R2 10/05/2010 ERD (TST6049) ASTM D1970 (OH) S37210.11.11 11/09/2011 ERD (TST6049) ASTM D1970 (MS) S37210.12.11 12/01/2011 ERD (TST6049) ASTM D1970 (MS) S40540.02.13-1 02/19/2013 ERD (TST6049) FRSA/TRI 04-12(MS) S43530.02.14-1-R1 02/21/2014 ERD (TST6049) ASTM D1970(BC) S44870.04.14-2 04/02/2014 ERD (TST6049) ASTM D1970 (QC) 544870.04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (OH) S44870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (MS) S44870.04.14-4 04/10/2014 ERD (TST6049) ASTM D1970 (OH) 540540.10.14 10/31/2014 ERD (TST6049) Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD (TSr6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015 ERD (TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 M-D(CER1592) HVHZCompliance 18-0329.03 06/28/2018 ICC-ES(EVL2396) 2015 IEC Compliance ESR-1524 03/01/2017 NEMO (TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-RI 04/25/2018 NEMO (TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018 NEMO (TST6049) A5TM D4798/D1970 (OH & MS) 45-SOPC-18-D02.05.19.A 05/31/2019 NEMO (TST6049) Tensile Adhesion / Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020 NEMO (TSr6D49) Peel adhesion (existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-20-SSUDL-01 12/16/2020 PRI(TST5878) ASTM D1970 (MS) SOP-064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control MLA File No. R16814 12/10/2015 UL, LLC (QUA9625) Quality Control MLA File No. R27605 05/08/2019 UL, LLC (QUA9625) Quality Control Service Confirmation 06/29/2020 UL, LLC (QUA9625) Quality Control Florida BCIS Current NEMO ETC, LLC Evaluation Report 518010.06.09-1119 Certificate Of Authonmtion#32455 7T"EDITION (2020)FBC NON-HVH2 EVALUATION FL2569-R21 Soprema Roof Underlayments Revision 19: 12/15/2020 Page 2 of 9 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 NNEMO etc. Product Material Plant(s) Description Standard Lastobond TU HT ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric FRSA/TRI 09-18 surfaced, SBS modified bitumen roof underlayment Tri-Built S/A HTTU ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric Underlayment FRSAITRI 09-18 surfaced, SBS modified bitumen roof underlayment Lastobond Shield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch RESISTO SA SMOOTH PLY ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS 40 modified bitumen roof underlayment Lastobond Shield HT ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment Lastobond Pro HT-N ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available In two widths; 36 and 45 inch Lastobond Pro HT-5 ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment EnviroShield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment Lastobond 195 ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand - Wadsworth, OH surfaced, SBS modified bitumen roof underlayment Lastobond Eaves ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand - Protection Sheet Wadsworth, OH surfaced, SBS modified bitumen roof underlayment Lastobond Eco ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment Lastobond Smooth Seal ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film - HT Wadsworth, OH surfaced, SBS modified bitumen roof underlayment Tri-Built Smooth HT S/A ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film- Underlayment Wadsworth, OH surfaced, SBS modified bitumen roof underlayment PrimeSource Grip -Rite ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film - Smooth Seal HT Wadsworth, OH surfaced, SBS modified bitumen roof underlayment RESISTO L81236 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Gulfport, MS surfaced, 585 modified bitumen roof Wadsworth, OH underlayment TRI-BUILTSand-R SA ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Shingle Underlayment Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment MEMO ETC, LLC Evaluation Report S18010.06.09-R19 Certificate ofAuthoroatiun 431455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FLZ569-R21 Soprema Roof Underlayments Revision 19: 12/15/2020 Page 3 of 9 4.17 4.18 4.19 4.20 1N NEMO J etc. Product Material Plant(s) Description Standard PrimeSource Grip -Rite ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand- Eave & Valley Protector Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment SRS TopShield ICE & ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - WATER DEFENDER Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment RESISTO LB1244 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment Colphene FR GR ASTM D6163 Gulfport, MS self -adhering, fiberglass reinforced, granule - Wadsworth, OH surfaced, SBS modified bitumen roof underlayment 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not Include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS f aC Sectim. 1507.2 1S87.3 1507.4 81507.5 1507.7 1S07.8 61507.9 Clay and Concrete Tile Clay Metal Slate or Asphalt Shakes or Mechanicaln � Panels Shingles UndMaymeM Shingles SShingles ype Shingles Lastobond TU HT, Tn-Built 5/A HTTU Yes Yes Yes Yes Yes Yes Yes IIolm p5.1sn71.3/ Underlayment See 5.6.1 Lastobond Shield, Pro HT-N, RESISTO SA Yes No No No No Yes Yes SMOOTH PLY 40 Uoml anes.lso7l.u/ R90R.1.]3I Yes Lastobond Shield HT, Pro HT-S Yes No No Yes Yes Yes UoiM Won, 1507.1.13/ RM1.131 Yes EnviroShield Yes No No Yes Yes Yes Udol:ldw.lso7.11.3/ R905.1.1.31 Lastobond Eaves Protection Sheet, Yes No No No No Yes Yes Urine ands, lso7.113/ Lastobond 195 Rsos.v31 NEMO ETC, LLC Evaluation Report 518010.06.09-R19 Certificate ofAuthonmtion 432455 7" EDITION (2020)FBC NON-HVHZ EVALUATION FL2569-R21 Soprema Roof Underlayments Revision 19: 12/15/2020 Page 4 of 9 NNEMOjetc. TABLE 1: ROOF COVER OPTIONS FBCSeedon: 1507.2 1507.3 1507.4 & 1507.5 1507.7 1507.8411S079 Clay and Concrete Tile Metal Slate or UnderlaymentUnderlaymentAsphalt slate_Type Wood Shako or Mechanical Adhesive- Shingles Attach Set Panels Shingles Shingles Shingles Lastobond ECO, RESISTO LB1236, TRI- BUILT Sand-R SA Shingle Underlayment, Yes Grip -Rite Eave& Valley Protector, Yes No No No No Yes 0o1ntswps,M7AJ.3/ TopShield ICE & WATER DEFENDER, asos.1.131 RESISTO LB1244 Lastobond Smooth Seal HT, Tri-Built Yes Smooth HT S/A Underlayment, Grip -Rite Yes No No Yes Yes Yes fiord ad" 1507.1.14/ Smooth Seal HT asosl.lal Yes Colphene FR GR Yes Yes No No No Yes fiord nn�. M7.1.1.3 / R905.1.13) 5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment / tile -adhesive combinations. TABLE 1A: ALLOWABLE TILE ADNESIVE / UNDERLAYMENT COMBINATIONS' Underlayment Adhesive Florida Product Approval Lastobond TU HT, Tri-Built S/A HT TU Underlayment Dupont'Tle Bond'" Roof Tile Adhesive' FL22525 ICP Adhesives and Sealants "Polysete AH-160" FL6332 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Material(s) Lastobond Shield, Lastobond Pro (Optional) ASTM plywood, OSB or Souther Yellow Pine HT-N, RESISTO SA SMOOTH PLY Deck / D41, Elastocol Stick, (SYP) 40, Lastobond Shield HT, sheathing Elastocol Stick Zero ASTM D41 structural concrete Lastobond Pro HT-S, Enviro5hield, Lastobond TU HT, (Optional) Elastocol Dens Deck Prime or SECUROCK Gypsum- Tri-Built S/A HT TU Insulation Stick Zero Fiber Roof Board Underlayment, Lastobond Eaves Protection Sheet, Lastobond 195, self_ Lastobond ECO, RESISTO LB1236, adhering TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & Base Sheet (Optional) Elastocol ASTM D226, Type II felt or Modified Sopra- WATER DEFENDER, RESISTO Stick Zero G LB1244, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT Deck / (O41 ional) ASTM Plywood sheathing ASTM D41 structural concrete Col hene FR GR self - adhering Insulation (Optional) Elastocol Dens Deck Prime or SECUROCK Gypsum - Stick Zero Fiber Roof Board (optional) Elastocol ASTM D226, Type II felt or Modified Sopra- Base Sheet Stick Zero G 1 Refer to Tile Manufacturers or Adhesive Manufacturers Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report S38010.06.09-1119 Certifiane ofAuthonrotion 032455 Te EDITION 12020) FBC NON-HVHZ EVALUATION FL2569-R21 Soprema Roof Underlayments Revision 29: 12/15/2020 Page 5 of 9 ONEMOletc. TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Material(s) Lastobond TU HT, Tri-Built S/A HT TU Underlayment, RESISTO LB1236, TRI-BUILT Sand-R SA self- Existing RESISTO EXTERIOR Existing sand -surfaced, glass -fiber surfaced, Shingle Underlayment, Grip -Rite mineral -surfaced or film -surfaced roof Eave & Valley Protector or adhering substrate PRIMER underlayment' TopShield ICE & WATER DEFENDER -Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lastobond TU HT, Tri-Built S/A HT TU Underlayment, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. 5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached base sheets - not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure = -45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered. #2 Maximum Design Pressure = -67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol Stick Zero Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered. NEMO ETC, LLC Evaluation Report S38010.06.09-R39 Cenificate of Authorization #32455 rH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R21 Soprema Roof Underlayments Revision 19: 12/15/2020 Page 6 of 9 ONEMOletc. #3 Maximum Design Pressure = -120.0 osf: Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) RESISTO EXTERIOR PRIMER Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered. Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered. #4 Maximum Design Pressure=-150.0 osf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered. #5 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of -45 psf. 5.8.3.2 Mechanically -Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #6 Maximum Design Pressure =-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6- inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered 5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment attachment shall be in accordance with the manufacturers installation instructions and attachment of the insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product Approval. 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Prepared Roof Cover Maximum Underlayment Installation Type Exposure (days) Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB1236, TRI- Mechanically BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE attached 30 & WATER DEFENDER or RESISTO LB1244 Adhesive -set tile roof 30 Lastobond TU HT, Tri-Built S/A HT TU Underlayment system Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Mechanically Lastobond Pro HT-S, EnviroShield, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A attached 90 Underlayment or Grip -Rite Smooth Seal HT Lastobond TU HT, Tri-Built S/A HT TU Underlayment or Colphene FR GR Mechanically attached 180 NEMO ETC, LLC Evaluation Report 518010.06.09-1119 Certificate of Authorization N32455 7TH EDITION (2020)FBC NON-HVHZ EVALUATION FL2569-RZI 5oprema Roof Underlayments Revision 19: 12/15/2020 Page 7 of 9 ONEMO etc. 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 10-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Max. 10-tile stack (bottom 2-tile stack shall be Inverted, followed by 8 tiles high on slope, as shown below) 6:12 Lastobond TU HT, Tri- Built S/A HT TU Underlayment Lugged Flat Max. 10-tile stack 5:12 Colphene FR GR Lugged Max. 10-tile stack 6:12 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.2.1 Installation of RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 6.3 Lastobond TU HT, Tri-Built S/A HT TU Underlayment, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Enviro5hield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip -Rite Smooth Seal HT, RESISTO 1.131236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244 or Colphene FIR GR: 6.3.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base sheet shall be fastened in accordance with FBC 1507.1.2 or R905.1.1. NEMO ETC, LLC Evaluation Report 518010.06.09-R19 Certificate of Authodradon#32C55 7'"EDITION (2020)FBC NON-HVHZ EVALUATION FLZ569-1121 Soprema Roof Underlayments Revision 19: 12/15/2020 Page 8 of 9 ONEMOletc. 6.3.2 Tile Applications: Limited to Lastobond TU HT, Tri-Built S/A HT TU Underlayment or Colphene FR GR. Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 7. BUILDING As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. QUALITY9. UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 518010.06.09-R19 Certlflcute of Authoritation#32455 7" EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-RZ1 Soprema Roof Underlayments Revision 19: 12/15/2020 Page 9 of 9