Loading...
HomeMy WebLinkAboutAPPROVED, Design Pressure Report (Bauders) - Master Craft Aluminum ProductsProperty Information Owner:Bauders Address:29 Arboles del Norte Ft Pierce, Fl 34951 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 25 38 7 32.5 -35.2 2 Int 53 55 7 31.0 -33.7 3 Int 53 55 7 31.0 -33.7 4 Int 74 55 7 30.3 -33.0 5 Int 26 38 7 32.5 -35.2 6 Int 37 55 7 31.7 -34.5 7 Int 26 38 7 32.5 -35.2 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1