HomeMy WebLinkAboutAPPROVED, Building plans SU-1FULCRUM CONST. 11AS NOTEDRubenCANOPY DRAWINGSFORT PIERCE, FL 349493751 VIRGINIA AVEGENERALDOLLAR4/22/21Note:All framing is made of Aluminum and groundsmooth.All aluminum to be 6061-T6Aluminum Weld: IAW AWS D1.2(latest edition).Filler Alloy: 5356 or equalThis structure has been designed to comply withChapter 16 of the Florida Building Code 2020 7thEdition and ASCE 7-16. The design parametersare:Vult:170 mphVasd:132 mphRisk Category: IIExposure:CGCPi+/- 0.18Floor Live Loads (psf)10Uninhabitable attics without storage20Uninhabitalbe attics w limited storage30Habitable attics and sleeping areas40All other areas10Roof Live Load:--Component & Cladding +42.1 -48.5Scale: NTSISOMETRIC1Scale: 1/2" = 1'-0"SIDE VIEW3 17948-RH1 FRAME1"X2"AluminumMILL FINISH ClosedSTANDING SEAM PANMILL FINISH4"Wrap No Graphic -4/12/214/22/2150 Keyes CourtSanford, FL 32773407 330 1044 ph407 330 1477 faxBRYAN A. MOLYET P.E.Orange City, FL 327631060 East Industrial Dr, Ste, W(386) 532 8000Florida Certificate of Authorization No.00032041Reg. Fla. Engineer No. 04150917948WALL ATTACHMENT OPTIONS 438"x3" LAG BOLT3/8"x3"LARGE DIACONCRETE SCREW,MIN EMBED 2"FASTENERSEE RIGHT2"x1 12"x18" STEEL BRACKET2 #10x34" TEK SCREWSEE ABOVEFRAME MEMBEREITHER LOCATION IS ACCEPTABLE4'-0"4'-0"23'-0"1"4'-0"4'-0"4"10'-0" AFF1 1/2"16"GULFLOK STANDING SEAM .0625" 523'-0"4'-0"4Scale: 1/2" = 1'-0"ELEVATION252 1/4"1'-8"1'-8"1'-8"14-1/4x2"TEKMETAL STUDABOVE FRAMEUNDER FRAMESIDE OF FRAME