Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Efficiency Code
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: `�� � Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, ` Permit Number: Owner: WYNNE BUILDING CROP `;Z!�,0,\�` 0� Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 } 1. New construction or existing New (From Plans) 10. Wall Type�1442.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int. Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c, NIA R= ft2 4. Number of Bedrooms 2 d. NIA R= ft2 11. Ceiling Types (1476.0 sgft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade (ft2) 1446 b. Knee Wall (Vented) R=19.0 30,00 ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(141.3 sgft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 175 a. U-Factor: Sgl, U=1.04 101.25 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3,832 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.284 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor.(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (1445.5 sgft.) Insulation Area EF:0.970 a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features b. NIA R= ft2 None c. NIA R= ft2 16. Credits None Total Proposed Modified Loads: 44.57 Glass/Floor Area: 0.098 PASS Total Baseline Loads: 45.19 I hereby certify that the plans and specifications covered by Review of the plans and -ERE� this calculation are in compliance with the Florida Energy specifications covered by this Code, calculation indicates compliance ��* with the Florida Energy Code. PREPAR D Y Before construction is completed W DATE this this building will be inspected forI' compliance with Section 553.908 * t I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy- Wf OWNER/ G BUILDING OFFICIAL: DATE: y DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft2 _ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC t ft 0 63 ft' __ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft- ___ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' ____ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' ___ 0 1 0 6SIab-On-Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 fP ___ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 — 0 1 0 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Penmeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 __ 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63ft2 .1 Wood _ 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft= 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall (Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 _ 1 NE=>SW Exterior Concrete Block - Int InsuBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0.4 0 .2 SW=>NE Exterior Concrete Block- Int InsuBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 3 NW=>SE Exterior Concrete Block - Int InsuBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 _ 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 NE=>SW Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _ 6 NE=>SW Exterior Concrete Block - Int InsBEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 7 SE=>NW Exterior Concrete Block - Int Ins81EDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 _ 8 S=>N Exterior Concrete Block - Int InsBEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 _ 9 SW=>NE Exterior Concrete Block - Int Ins8EDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 _ 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 11 SW=>NE Exterior Concrete Block - Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block- Int InsuLAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _ 13 NE=>SW Exterior Concrete Block - Int InstOREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block - Int InstUREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall V # Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 1.04 0.29 Y 32.9 ft 1 ft 0 in 1 ft 5 in Drapes/blinds 1.04 0.29 Y 6.9 ft' 1 ft 0 in 1 ft 5 in None 1.04 0.29 Y 24.0 ft2 6 ft 0 in 1 ft 5 in None 1.04 0.29 Y 37.5 ft' 1 ft 0 in 1 ft 5 in None 1.11 0.27 Y 40.0 ft 8 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft- 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.04 139.01 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/hr oft 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft. DUCTS / — Supply— — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cod 1 Attic 6 175 f? Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Jan FebrX,� Vent Jan Feb ICooling Mar �ADOT Apr € May rMe rD(,t trXl, Oct Dec I(X'I Dec ng [X] (] Jun [ ] Jul Aug [ ] Sep X Nov [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Defautt(8 lbs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' It 0.3 WIC Default(81bs/sq.ft. ft2 It 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.fL ft' it 0.3 ENTRY Default(81bs/sq.ft. ft' ft 0.3 LAUNDRY Defau 8lbs/s .ft. ft' ft 0.3 GREATIDINING 1/12/2021 12:02 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street Permit Office: ST. LUCIE COUNTY City, State, 7iip: FT. PIERCE, FL, Permit Number. x Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R3 Knee wails shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking,or floor framing cavity g insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Baft insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninino and winno Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids Pre Anopkier cover plates and wells or ceilings a. in addition, irspecuon or iog wails shall De In accomance wain me provisions of KX400. 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. , FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 2 d. WA R= ft2 5. Is this a worst rase? yes 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft- 6. Conditioned floor area (W) 1446 b. Knee Wall (Vented) R=19.0 30.00 ft2 7. Windows" Description Area c. WA R= ft2 a. U-Factor SgI, U=1.04 101.25 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.29 a. Sup: Attic, Ret: Attic, AH: Attic 6 175 b. U-Factor. SgI, U=1.11 40.00 ft2 SHGC: SHGC--0.27 13. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft2 a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor. N/A f:2 SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.832 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.284 8. Skylights Description Area 15. Hot water systems a. U-FactogAVG): WA ft- a. Electric Cap: 50 gallons SHGC(AVG): N/A EF: 0.97 9. Floor Types InsuWtion Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 1445.;0 ft2 None b. N/A R= R2 Credits (Performance method) None c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card Will be completed based on installed Code compliant features. Builder Signature: 1 - Date: Address of New Home: `�y��j ty� �C, y/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 ® Project Summary J wrightsoft Entire House By QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-066£796 Emil: QUICKCALCS@AOL.COM Project For: WYNNE DEVELOPMENT CARLTON III, FT. PIERCE, FL o\\; c� Notes: Design Information Fort Fierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19691 Btuh Structure 16785 Btuh Ducts 5900 Btuh Duds 8919 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25591 Btuh Use manufacturers data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24418 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2065 Btuh Ducts 2429 Btuh Central vent (0 cfm) 0 Btuh Heatingg Area Coolingg (none) (ftz) 1602 1602 Equipment latent load 4493 Btuh Volume (fla) 14827 14827 Airchanges/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 28912 Btuh Equiv.AVF (cfin) 94 49 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIRCONDITIONING Model 25HBC536A 030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point= 34 OF 8.5 HSPF 34600 Btuh@47-F 27 OF 1160 cfrn 0.045 cfm/Btuh 0 in H2O Backup: Input=7kW, Output= 23009 Btuh, 100 AFUE Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A 030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensiblecooling 24360 Btuh Latent000ling 10440 Btuh Total 000ling 34800 Btuh Actual airflow 1160 cfrn Air flow factor 0.045 dm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.85 J.- Calculations approved by ACCAto meet all requirements of Manual J 8th Ed. Wrjghtt� 2021-Jan1212.04:36 ^a^��^^»^ Riga-SJtEOUnuersal 201919.021 RSU08101 Page ...,tS\WrigibAFNAQWYNNE-THE GRAND CARLMN.np Calc=MJ8 FrorrtWorfams: N 1 wrightsow Right-J® Worksheet Job: Entire House per: QUICK CALCS, INC. By. 317 ST. LUCIE UN., Fr. PIERCE, FL 34946 Phone: 772466-6799 FaK 772466-6796 Email: OUICKCALCS@4OL.COM 1 Room name Entire House BEDROOM 2 Exposdwall 1762 It I 41.0 ft 3 Room height 9.3 ft d 8.0 ft hasu=1 4 Roomdimensons x 18.0 ft I 5 Room area 1601Z R' 2520 fF Ty Oonstrur4on U-value Or HTM Area Load kea (� Load number fthtl.-9 (BWhflF) or perimeter (ft) (Btuh) or Wmeter (ft) (Btuh) Heat Cool Gros N/P/S Heat Cool Gros N/P/S Heat Cool 6 W 13A4os 0.143 ne 4.00 2.55 551 513 20M 1306 72 72 288 183 �C 1Aclom 1270 ne 35.56 70.43 38 0 1344 26U 0 0 0 0 VQ 13A4os 0.143 a 4.00 2.55 128 87 w 221 0 0 0 0 1AcOom 1270 se 35.56 70.95 20 0 711 1419 0 0 0 0 11 ��DC, 1100 0.390 se 10.92 11.31 21 21 229 238 0 0 0 0 W 13A4ocs 0.143 s 4.00 2.55 34 34 136 86 0 0 0 0 lQ/ 1344ors 0.143 sv 4.00 2.55 416 390 1562 993 144 144 577 367 1Aclom 1270 m 35.56 70.95 6 0 213 426 0 0 0 0 tAc7om 1270 m 35.56 70.95 20 0 711 1419 0 0 0 0 13A4os 0.143 nw 4.00 2,55 352 288 1151 732 112 88 354 225 1Ac1om 1270 nw 35.56 4524 12 0 415 528 12 0 415 528 to-dom 1270 nw 3556 4624 12 0 427 543 12 0 427 543 4A5-2omd 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 P 12C-0sw 0.091 - 2.55 128 120 120 306 154 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 1602 1602 1435 3715 252 252 226 585 F 22A-tol 0.989 27.69 0.00 1602 176 4878 0 252 41 1135 0 6 c)AED excurson 197 Envelope loss(gain 16802 15970 3421 2627 12 a) Infiltration 2890 815 640 180 b) Room ventilation 0 0 0 0 6ltemalgains: Oompants@ 230 0 0 0 Appliancesrothff - 0 0 0 Subh/fal (lines6 to 13) 1%91 16785 4061 2807 [14 Les exemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 Subtotal 19691 16785 4217 2807 DuQlOads 30% 53% 5900 8919 30% 53% 7217 1491 1491 Total room load 25591 25704 5278 4298 Air required (cfm) 1160 1160 239 194 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed '+}�' wrigtftstaTC RgK-Sute®Uriversa1201919.022021-J-n1212:04:367 RSU08101 Page 1 .atskWdgtiwft HVACIWYNNE-THE GRAND CARLTON.np Calc=NW FraaDoorfaWS: N wrightsoW Right-J® Worksheet J°b.' Entire House QUICK CALCS, INC. 3y 317ST.LUCELN.,Fr..PIERCE,FL34946PtDM:772-466-6799F=772466-6796 Email:QUrKCALCS@AOL.COM 1 Room name WIC MASTER BATH 2 Bposed wall 0 ft 17D it 3 Room height 80 tt heaNmol 8D ft hedcool 4 5 Room dimensiom Room area 7.0 x 9A It 63D ft' 7A x 17A it 119.0 iF Ty Construdon U-Ndue Or HTM Area (fF) Load Area (fl Load number (BtuhAf-'q (BIuhAn or perimeter (fl) (Ruh) or pedmeer (ft) (8Wh) Heat Caul G. NLPS Heat Cool Gross N/P/S Heat Cool 6 V1! 13A4= 0.143 m 4.00 2.55 0 0 0 0 0 - 0 0 0 I—G 1Ac1an 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 h/ 13A-4= 0.143 w 4A0 2.55 0 0 0 0 0 0 0 0 I�----DG 1A 1= 1270 w 3556 70.95 0 0 0 0 0 0 0 0 11 11DO 0" se 10.92 11.31 0 0 0 0 0 0 0 0 w 13A4= 0.143 s 4D) 2.66 0 0 0 0 0 0 0 0 Yy 13A4as 0.143 w 4m 2.55 0 0 0 0 136 130 521 331 1Ac1w 1270 w 3556 70.95 0 0 0 0 6 0 213 426 L�—GG 1Aciom 13AA= 12M OA43 sw m 3556 4.00 70.95 255 0 0 0 0 0 0 0 0 0 0 0 0- 0 0. 0 -. 0 1Ac1om 1270 w 3556 4624 0 0 0 0 0 0 0 -. 0 1Ac1om 1270 hw 3556 4524 0 0 0 0 0 0 -. 0 0 4A6-2omd 0.770 m 2156 36.90 0 0 0 0 0 - 0 .0 0 P 12C-Om 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A30md OD32 - 0.90 2.32 63 63 56 146 119 119 - 107 - - 276 F 22Ap11 0.989 - 27.69 0.00 63 0 0 0 119 17 471 0 6 c)AEDe%cum n -13 55 Bwdope losskpn 56 133 1311 1087 12 a) Infiltraton 0 0 285 75 b) Room mifflation 0 0 0 0 13 Intemalgains Omrpanls@ 230 0 0 0 0 Appliarxa4otrer 0 0 Subtotal (11nes6lo 13) 56 133 1577 1162 Les wdamal load 0 0 0 0 Lewtansfar 0 0 0 0 Redishibuton 0 0 0 0 14 Subtotal 56 133 1570 1162 15 Dud loads 30% 53% 17 71 SM. 53% 472 618 Total room load 73 204 2049 1780 Airrequired(Cm) 3 9 1 93 80 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. ,� '�'�+' wr1i9F+t�srolC" 2021Jan12120436 I&A Riga-Sdte®lPrioersa1201919.021 RSW8101 PW 2 ...reiWrightaut WAC\W7'NNE-THE GRAND CARL70N.np Calc=MA FrortDoorfamsN wrightsofr RighW@ Worksheet Job: Entire House Date; QUICK CALCS, INC. sY 317 ST. LUCIE LN., FL PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: QUICKCALCS@AOL.COM 1 Room name KrrCHEN BATH 2 Exposdwall 0 It 5.0 It 3 Room height 8.0 It heaVcool 9.4 It heaVood 4 Room dimensons 1.0 x 192.0 ft 9.0 x 5.0 it 5 Room area 192.0 V 45.0 IF Ty Construction U-value Or HTM Area (1F) Load Area (,ftl Load number (Btl --°9 (BIuhM or perimeter (ft) (Bbih) or perimeter (ft) (Buh) Heat Cool Gras N/P/S Heat Coal Gross WP/S Heat Cool 6 W s 13A-4o 0.143 ne 4.00 2.55 0 0 0 0 47 47 188 120 �C 1Aciom 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 13A-4o s 0.143 se 4.00 2,55 0 0 01 0 0 0 0 0 tAc1om 1270 s 3556 70.95 0 0 0 0 0 0 0 0 11 11D0 0390 s 1092 1131 0 0 0 0 0 0 0 0 W 13A4as 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 13AA= 0.143 sH 4.00 2.55 0 0 0 0 0 0 0 0 1Actom 1270 sv 3556 70.95 0 0 0 0 0 0 0 0 1Ac1am 1270 sv 35.56 70.95 0 0 0 0 0 0 0 0 13A-4= 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 1Ac1om 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4A5-2amd 0.770 rrw 21.56 36.90 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 192 192 172 445 45 45 40 104 F 22A-V 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 6 c)AEDem/rsion 39 -22 Envelope loss/gain 172 406 367 202 12 a) Infiltration 0 0 92 26 b) Room wnlilation 0 0 0 0 13 Intemal gains: O=pant3@ 230 0 0 0 0 Applianredother 0 0 Subtobl(lines6to13) 172 406 459 228 Lese#emalload 0 0 0 0 Lestranster 01 0 0 0 Redistribution Oii. 0 0 0 14 Subtotal 1721 406 459 228 15 Ductloads 309/6 53% 521 216 30% 53% 137 121 Total room load 224 622 596 349 Airrequired(Crn) 10 28 27 16 Calculations_ approved byACCAto meet all reauirements of Manual J 8th Ed 2021-Jan-1212:04:36 AGGA Ri9kSuteOUriversal 2019 %021 RSUD8101 Page 3 ...rits\Wngifsoft WAQWYNNE-THE GRAND CARLION.rup Calc=M18 Front Doorfews, N wrightsofC Right-J@ Worksheet Job� Entire House Date: QUICK CALCS, INC. By. 317ST.LUCELN..Fr..PIERCE.FL34946Phore:772-4666799 Fac772-066-6796 Emil: QUICKCP.LCS@AOLCOM 1 Room dame BEDROOM2 ENTRY 2 6posed well 302 ft 6.0 ft 3 Room height 8.0 It heatlmol 8A ft heeVCOd 4 Room dimensions 1.0 x 1905 ft 6.0 x 10.0 ft 5 Roomaw 1905 it 60.0 ff Ty Consnlclim Uaalue or HTM Area (fe) Load Area (fe) Load number (BWhAP-°n (BWhdl) or perimeter (ft) (BWh) or pedmeter (1t) (BWh) Heat Cool G s NSS Heat Cod Gross NIPS Heat Coot 6 W 13A-4ols 0.143 ne 4.00 255 120 120 480 305 0 0 0 0 _C 1Actan 1270 m 3556 70.43 0 0 0 0 0 0 0 0 13A-4= 0.143 se 4.00 255 80 60 240 153 48 27 108 69 1A-dom 1270 se 3556 70M 20 0 711j 1419 0 0 0 0 11 11DO 0390 se 10.92 1131 0 0 01 0 21 21 229 238 W -13rWas 0.143 s 4DO 255 34 34 136 85 0 0 0 0 yl 13A4= 0.143 aw 4A0 255 8 8 32 20 0 0 0 0 1Ao1an 12M sw 35M 70—% 0 0 0 0 0 0 0 0 L�—CG 1A-Mom 1270 sw 3556 70.95 0 0 0 0 0 0 0 0 13A4= 0.143 rw 4.00 255 0 0 0 0 0 0 - 0 0 1Ao1an 12M nw 35M 4524 0 0 0 0 0 0 0 - 0 1Ac1an 1270 nw 3556 4524 0 0 0 0 0 0 0 0 4A5.2omd 0.770 rw 2156 36.90 0 0 0 0 0- 0- - 0 0 P 12C-Ow 0191 255 128 0 0 0 0 0 0 0 0 C 16A30md Om2 - OaO 232 191 191 171 442 60 - 60 54 139 F 22A-fil 0.989 - 27.9 0.00 191 30 835 0 60 6 166 0 6 c)AED exarson 209 -41 Ernalope bWgain 2606 2635 557 404 12 a) NSltralion 472 133 94 26 b) RcorrnvenAlation 0 0 0 0 13 Ntemal gaim Ooarpan6@ 230 0 0 0 0 Appliarlmshther 0 0 Subblal(lms6b13) 3078 2768 651 430 mal load 0 0 0 0r0 0 0 0 ufion0 0 0 0 t 3078 2768 651 430s 30% 53% 922 1471 30% 53% 195 229 mload 4000 41 846ed (dm) 181 191 38 30 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed Rigitsu+B@Uiww[201919.021RSU08101 20214a 1212PA436 ...rLAWdgft=RWAC\WY NE-THEGRANDCARLIONAp Calc=M18 Frord Dooriaces N wrightsoft` Right-M) Worksheet Job: Entire House Dom: QUICK CALCS, INC. By. 317 ST. LUCIE LN.,Fr. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCiLCS@AOL.COM 1 Room name LAUNDRY GREATIDWWG 2 Bposedwall 6D ft 46.0 ft 3 Room height 81) ft heatlmol 12.0 It heaCmol 4 Room dimensions 7.0 x 6.0 ft 1.0 x 488D ft 5 Room area 42D 1F 488.0 IF Ty Con.Lucton U-%alue or HTM Area (et Load ArmLoad (m number (swtJft'-°Fj (BwhfiF) or perimeter (IO (BWh) or Pad �r (IU (85+h) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 l}/ 13A-4ols 0.143 na 4D0 255 0 0 0 0 312 274 1098 698 -1A-dom -M4= 1270 re 3556 70.43 0 0 0 0 38 0 1344 2662 0.143 se 4.00 255 0 0 0 0 0 0 0 0 tAciom 1270 w 35M 70.95 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 w 13AAc s 0.143 s 4DO 255 0 0 0 0 0 0 0 - 0 13A-4als 0.143 sw 4.00 Z55 48 46 192 122 0 0 0 0 tAcicm 1270 aw 35M 70.95 0 0 0 0 0 0 0 0 1Ac1w 1270 sw 35M 70.95 0 0 0 0 0 0 0 0 13AAM 0.143 w 4D0 255 0 0 0 0 240 199 798: - 507 1Aclom 12m w 3556 45.24 0 0 0 0 0 0 0 0 1Ac1an 1270 my 3556 4524 0 0 0 0 0 0 0 0 4A5-2omd 0.770 rw 21.56 36.90 0 0 0 0 41 0 880 - 15% P 12C-Osv OD91 - 255 128 0 0 0 0 0 0 0 0 C - 16430md OD32 - 090 2.32 42 42 38 97 488 488 437 1132. F 22AAA 0989 - 279 0.00 42 6 166 0 488 46 1274 0 6 c)AEDex arson -22 597 Envelope loss/gain 396 198 51W 5908 12 a) Infiltration 94 26 1077 304 b) Rocmverdation 0 0 0 0 13 Internal gains Omlpants@ 230 0 0 0 0 Applianoes(other 0 0 Subtolal(lines6to13) 490 224 6907 6212 Les exemal load 0 0 0 0 Lessrarlsfer 0 0 0 0 Redistribution 0 0 0 0 14 Subbotal 490 224 6907 6212 15 Ductloads 30% 53% 147 119 30% 53% 2070 3301 Total room load 636 344 8977 9512 Air required(dm) 29 16 407 429 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed Aft-4I `W'� 2021Jan1212D436 k RigitSULOUriwe 1201919.021 RS1108101 Page ..xtslWngHmft HVAQWVNNE-TIE GRAND CMLTONnp Calc=" FrortDoorfao:sN wrightsoft• RighW@ Worksheet Job; Entire House Date: QUICK CALCS, INC. By. 317 ST. LLIGE LN., F.. PIERCE, FL 34946 Phore: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@4OL.COM 1 Room name BEDROOMS 2 Eposedwall 25.0It 3 Room height 8.0 It heaVcool 4 Room dimensions 15.0 x 10.0 It 5 Room area 150.0 b' Ty Consbudon U-value Or HTM Area (ft=) Load Area Load number (BWh4li°F) (BWhfif� or penmeter (ft) (eWh) or perimeter Heat Cool Gros N/P/S Heat Cool Gras N/P/S Heat Cool 6 13A4ocs 0.143 ne 4.00 2-95 0 0 0 0 1Aclom 1270 ne 35.56 70.43 0 0 0 0 13A-4ocs 0.143 se 4.00 2,55 0 0 0 0 1Aclom 1270 se 35.56 70.95 0 0 0 0 11 11D0 0.390 se 1092 11.31 0 0 0 0 W 13A-4ow 0.143 s 4.00 2.55 0 0 0 0 41/ 13A-0as 0.143 sw 4.00 2S5 80 60I 240 153 G 1Aclom 1270 sw 35.56 70.95 0 0 0 0 L�� tAtlom 1270 sw 3556 7095 20 0 711 1419 0.143 nw 400 255 0 0 0 0 TE�13A-4ors 1Aciom 1270 nw 3556 4524 0 0 0 0 1Ac1om 1270 nw 35M 4524 0 0 0 0 4F5.2omd 0.770 nw 2156 36590 0 0 0 0 P 12C-0sv 0.091 2.55 128 120 120 306 154 c 16A30md 0.032 - 0.90 2.32 150 150 134 348 F 22A-t I 0989 - 27.69 0.00 150 25 692 0 6 c)AEDe m.on 296 Envelope losJgain P084 2369 12 a) Infiltration 156 44 b) Roommenblation 0 0 13 Intemal gains: Occupants@ 230 0 0 Applimcas(other 0 Subtotal(lines6to13) 2240 2413 Les erlemal load 0 0 Lessbansfer 0 0 Redistribu0on 0 0 14 Subtotal 2240 24131 15 Dud loads 300/6 53% 671 1282 Total room load 2911 3695 Air required (dm) 132 167 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed c 2021-Jarv1212O436 AC�t1 Right -Suite® Uriversal 201919.021 RSU08101 Page 6 ...rtAWrigKroRHVAC\WYNNE-THEGRANDCARLION W Calc=M18 Front Cocrfaces: N