Loading...
HomeMy WebLinkAboutAugercast Piling Inspection Form0 REPORT # 18-9005.01 ORDER #: PERMIT #: DATE: 3/5/2019 /2TERNATIC PROJECT: Hinkle - 246'Bimini -Auger Cast OWNER: Don Hinkle, CONTRACTOR: Don Hinkle Construction PILE CONTRACTOR: Brevard Grouting DRILLING SUPERINT.: ADDRESS: 246 Bimini Dr CITY: Fort Pierce STATE: FL 0 PUMP No.: 1 ON -SITE: 9:00am TRAVEL: 'Ism Cu.Ft/STOKE: OFF -SITE: TOTAL HRS: 1.34 4:00 m 7 WEATHER: Overcast TEMP: WIND: HUMIDITY: PILE No.: 1 2 3 4 5 6 7 8 9 10 11 12 13 PILE LOCATION: PILE DIAMETER: 14 14 14 14 14 14 14 14 14 14 14 14 14 PILE LENGTH: 25 25 25 25 25 25 25 25 25 25 25 25 25 ACTUAL TIP ELEV.: ACTUAL SURFACE ELEV. THEOR. PILE VOL. (cu.ft.) ACTUAL GROUT VOL. (cu.ft.) TRUCK No. 430 430 430 430 430 430 430 616 616 616 616 616 616 BATCH TIME 8:30 8:30 8:30 8:30 8:30 8:30 8:30 9:47 9:47 9:47 9:47 9:47 9:47 No. STROKE 1st 5' TOTAL 8 8 8 8 8 8 8 8 8 8 8 8 8 29 30 31 30 32 30 28 28 28 30 28 29 29 REINF. STEEL. TYPE SIZE DEPTH C C C C C C C C C C C C C NOTES: C = 5 #5 @ 25-feet long and #3 stirrups @ 12' O.C. LEGEND C= T= Compression Bar Tension Cage Additional Comments 5.5 Strokes Strokes to fill 55 gallon drum for calibration done on 1st day or pump change INSP. PERFORMED BY: RM & TG Grout head was at least 1.6 for all piles. DISTRIBUTION: UFA International, nc. 607 NW Commodity Cove, Port St. Lucie, Florida 34986 Phone: (772) 924-3575 Fax: (772) 924-3580 ■ ■ 0 REPORT # 18-9005.01 ORDER M PERMIT #: ti DATE: 3/512019 yT�RNAT\CAP PROJECT: Hinkle - 246 Bimini - Auger Cast OWNER: Don Hinkle . CONTRACTOR: Don Hinkle Construction PILE CONTRACTOR: Brevard Grouting DRILLING SUPERINT.: ADDRESS: 246 Bimini Dr CITY: Fort Pierce STATE: FL PUMP No.: 1 ON -SITE: 9:00am TRAVEL: O■ Cu.FtJSTOKE: OFF -SITE: TOTAL HRS: 1.34 4:00 m 7 WEATHER: Overcast TEMP: WIND: HUMIDITY: PILE No.: 14 .15 16 17 18 19 20 21 22 23 24 2.5 26 PILE LOCATION: PILE DIAMETER: 14 14 14 14 14 14 14 14 14 14 14 14 14 PILE LENGTH: 25 25 25 25 25 25 25 25 25 25 25 25 25 ACTUAL TIP ELEV.: ACTUAL SURFACE ELEV. THEOR. PILE VOL. (cu.ft.) ACTUAL GROUT VOL. (cu.ft.) TRUCK No. 616 210 210 210 210 210 210 210 662 662 1 662 662 662 BATCH TIME 9:47 10:49 10:49 10:49 10:49 10:49 10:49 10:49 12:01 12:01 12:01 12:01 12:01 No. STROKE 1st 5' TOTAL 8 8 8 8 8 8 8 8 8 8 8 8 8 29 30 28 29 31 29 28 29 29 30 31 30 30 REINF. STEEL. TYPE SIZE DEPTH C C C C C C C C C C C C C NOTES: C = 5 #5 @ 25-feet long and #3 stirrups @ 12" O.C. LEGEND C= T= Compression Bar Tension Cage Additional Comments 5.5 Strokes Strokes to fill 55 gallon drum for calibration done on 1 st day or pump change INSP. PERFORMED BY: RM & TG Grout head was at least 1_& for all piles. DISTRIBUTION: GFA International, nc. 607 NW Commodity Cove, Port St. Lucie, Florida 34986 Phone: (772) 924-3575 Fax: (772) 924-3580 AUGERCAST PILING REPORT # 18-9005.01 ORDER #: PERMIT#: DATE. 3/5/2019 FRNATION PROJECT: Hinkle - 246.Bimini - Auger Cast OWNER: Don Hinkle CONTRACTOR: Don Hinkle Construction PILE CONTRACTOR: Brevard Grouting DRILLING SUPERINT.: ADDRESS: 246 Bimini Dr CITY: Fort Pierce STATE: FL INS,' 'CTION PUMP No.: 1 ON -SITE: 9:00am TRAVEL: FORM Cu.Ft./STOKE: OFF -SITE: TOTAL HRS: 1.34 4:00 m 7 WEATHER: Overcast TEMP: WIND: HUMIDITY: PILE No.: 27 28 29 30 31 32 33 34 35 36 37 38 39 PILE LOCATION: PILE DIAMETER: 14 14 14 14 14 14 14 14 14 14 14 14 14 PILE LENGTH: 25 25 25 25 25 25 25 25 25 25 25 25 25 ACTUAL TIP ELEV.: ACTUAL SURFACE ELEV. THEOR. PILE VOL. (cu.%) ACTUAL GROUT VOL. (cu.ft.) TRUCK No. 662 662 616 616 616 616 616 616 43D 430 430 430 430 BATCH TIME 12:01 12:01 12:39 12:39 12:39 12:39 12:39 12:39 1:30 1:30 1:30 1:30 1:30 No. STROKE 1st 5' TOTAL 8 8 8 8 8 8 8 8 8 8 8 8 8 30 28 30 29 29 29 27 30 29 31 31 30 27 REINF. STEEL. TYPE SIZE .DEPTH C C C C C C C C C C C C C NOTES: C = 5 #5 @ 25-feet long and #3 stirrups @ 12" O.C. LEGEND C= T= Compression Bar Tension Cage Additional Comments 5.5 Strokes Strokes to fill 55 gallon drum for calibration done on 1st day or pump change INSP. PERFORMED BY: RM & TG Grout head was at least 1_6 for all piles. DISTRIBUTION: GFA International, nc. 607 NW Commodity Cove, Port St. Lucie, Florida 34986 Phone: (772) 924-3575 Fax: (772) 9243580 oAUGERCAST PILING INS( • FORM REPORT # 18-9005.01 • ORDER #: PERMIT#: PUMP No.: 1 Cu.Ft./STOKE: 1.34 /yrFRNAT\0 DATE: 3/5/2019 ON -SITE: 9:00am OFFSITE: 4:00 m TRAVEL: TOTAL MRS: 7 PROJECT: Hinkle - 246 Bimini - Auger Cast OWNER: Don Hinkle' CONTRACTOR: Don Hinkle Construction WEATHER: Overcast PILE CONTRACTOR: Brevard Grouting TEMP: DRILLING SUPERINT.: WIND: ADDRESS: 246 Bimini Dr HUMIDITY: CITY: Tort Pierce STATE: FL PILE No.: 40 4011 41 PILE LOCATION: PILE DIAMETER: 14 14 14 PILE LENGTH: 25 25 25 ACTUAL TIP ELEV.: ACTUAL SURFACE ELEV. THEOR. PILE VOL. (cu.fL) ACTUAL GROUT VOL. (cu.fL) TRUCK No. 430 430 430 BATCH TIME 1:30 1:30 1:30 No. STROKE 1st 5' TOTAL 8 8 8 9 31 30 REINF. STEEL. TYPE SIZE DEPTH C C C NOTES: C = 5 #5 @ 25-feet long and #3 stirrups @ 12" O.C. Redrill Pile No. 40 due to clogged grout hose. LEGEND (;= Compression Bar T= Tension Cage Additional Comments 5.5 Strokes Strokes to fill 55 gallon drum for calibration done on 1st day or pump change INSP. PERFORMED BY: RM & TG Grout head was at least 1_5' for all piles. DISTRIBUTION: GFA International, nc. 607 NW Commodity Cove, Port St. Lucie, Florida 34986 Phone: (772) 924-3575 Fax: (772) 924-3580