HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Busin
egulation - Residential Performance Method
Project Name: HINKLE REST E
wilder Name:
Street: 246 BIMINI DR VE
ermit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERC , FL, FEB 14 2019
rmit Number:
Owner: DON HINKLE
J risdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce Permitting D e p a rtm e n tc unty: St. Lucie (Florida Climate Zone 2 )
St' f
61. New construction or existing ewI
Wall Types (2820.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=9.0 2470.00 ft2
b. Concrete Block - Ext Insul, Adjacent
R=9.0 350.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2352.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2352.00 ft2
6. Conditioned floor area above grade (ft2) 2352
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows (392.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AHU
6 250
a. U-Factor: Sgl, U=0.45 232.00 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.45 160.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
45.5 SEER:20.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.270
14. Hot water systems
a. Propane Tankless
Cap: 1 gallonsEF:
8. Floor Types (2352.0 sqft.) Insulation Area
0.600
a. Slab -On -Grade Edge Insulation R=0.0 1575.00 ft2
b. Conservation features
b. Raised Floor R=0.0 777.00 ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.167 Total Proposed Modified Loads: 75.02
PASS
Total Baseline Loads: 87.47
I hereby certify that the plans and specifications covered by
Review of the plans and
FTE SrAr
this calculation are in compliance with the Florida Energy
specifications covered by this
_
Code...
calculation indicates compliance
cq ii„ '` �'- �.��` VO
`.'.,
with the Florida Energy Code.
rrnrra.. ''��. •,;:€••;sw ;,
PREPARED BY:
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
..
*. t n
I hereby certify that this building, as designed, is in compliance
the Florida Energ C de.
Florida Statutes.
�oD
with
W.6
OWNER/AGENT:. - 'I'Ll(�
BUILDING OFFICIAL:
DATE: Z 44 V l-9
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this pri
an envelope leakage test report with envelope leakage no greater than 7.00.F/ACki50 SR4 .2
t;l L v
FEB 1 4 2019
1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Softwar Permitting D e p a rtmage 1 of 7
St. Lucie County,
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
HINKLE RESIDENCE
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2352
Lot #
Owner Name:
DON HINKLE
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
246 BIMINI DRIVE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2352
23520
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
GREAT ROOM
468
4680 No
0
1
Yes
Yes
Yes
2
KITCHEN
329
3290 Yes
0
1
Yes
Yes
Yes
3
POOL BATH
36
360 No
0
1
Yes
Yes
Yes
4
•
M BATH
78
780 No
0
1
No
Yes
Yes
5
MASTER SUITE
224
2240 No
0
1
1
Yes
Yes
Yes
6
M WIC
42
420 No
0
1
No
Yes
Yes
7
AHU
9
90 No
0
1
No
Yes
Yes
8
LINEN
9
90 No
0
1
No
Yes
Yes
9
LAUNDRY
70
700 No
0
1
No
Yes
Yes
10
CLST 2
20
200 No
0
1
No
Yes
Yes
11
BEDROOM 2
168
1680 No
0
1
1
Yes
Yes
Yes
12
HALLWAY
92
920 No
0
1
No
Yes
Yes
13
STORAGE
30
300 No
0
1
No
Yes
Yes
14
STAIRS UP
74
740 No
0
1
Yes
Yes
Yes
15
WIC 4A
35
350 No
0
1
Yes
Yes
Yes
16
BEDROOM 4
196
1960 No
0
1
1
Yes
Yes
Yes
17
WIC 4
50
500 No
0
1
Yes
Yes
Yes
18
WIC 3
49
490 No
0
1
Yes
Yes
Yes
19
LINEN UP
10
100 No
0
1
No
Yes
Yes
20
AC CHASE
4
40 No
0
1
No
Yes
Yes
21
LOFT
76
760 No
0
1
Yes
Yes
Yes
22
BEDROOM 3
195
1950 No
0
1
1
Yes
Yes
Yes
1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT \
SPACES
Number Name
Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
23 HALL BATH
88 880
No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
GREAT ROOM
44 ft
0
468 ft2
____
1
0
0
2 Slab -On -Grade Edge Insulation
KITCHEN
40 ft
0
329 ft2
____
1
0
0
e 3 Slab -On -Grade Edge Insulation
POOL BATH
6 ft
0
36 ft2
____
1
0
0
4 Slab -On -Grade Edge Insulation
M BATH
1 ft
0
78 ft2
____
1
0
0
5 Slab -On -Grade Edge Insulation
MASTER SUITE
21 ft
0
224 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulation
M WIC
1 ft
0
42 ft2
____
1
0
0
7 Slab -On -Grade Edge Insulation
AHU
1 ft
0
9 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulation
LINEN
1 ft
0
9 ft2
____
1
0
0
9 Slab -On -Grade Edge Insulation
LAUNDRY
1 ft
0
70 ft2
____
1
0
0
10SIab-On-Grade Edge Insulation
CLST 2
1 ft
0
20 ft2
1
0
0
11SIab-On-Grade Edge Insulation
BEDROOM 2
16 ft
0
168 ft2
____
1
0
0
12SIab-On-Grade Edge Insulation
HALLWAY
1 ft
0
92 ft2
____
1
0
0
13SIab-On-Grade Edge Insulation
STORAGE
1 ft
0
30 ft2
____
1
0
0
14Raised Floor
STAIRS UP
____
____
74 ft2
0
1
0
0
15Raised Floor
WIC 4A
____
____
35 ft2
0
1
0
0
16Raised Floor
BEDROOM 4
____
196 ft2
0
1
0
0
17Raised Floor
WIC 4
____
____
50 ft2
0
1
0
0
18Raised Floor
WIC 3
____
____
49 ft2
0
1
0
0
19Raised Floor
LINEN UP
____
____
10 ft2
0
1
0
0
20Ralsed Floor
AC CHASE
____
____
4 ft2
0
1
0
0
21Raised Floor
LOFT
____
____
76 ft2
0
1
0
0
22Raised Floor
BEDROOM 3
_-__
____
195 ft2
0
1
0
0
23Raised Floor
HALL BATH
____
____
88 ft2
0
1
0
0
1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 7
FORM R405-2017 INPUT bUIVIIVAKY UHLUKL1b I KLPUK
ROOF
Roof
Gable
Roof Solar
SA
Emitt
Emitt
Deck
Pitch
V
#
Type
Materials Area
Area
Color Absor. Tested
Tested
Insul.
(deg)
1
Hip
Metal 2630 ft2
0 ft2
Light 0.6
No
0.9
No
20
26.6
ATTIC
V
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Unvented
0
2352 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
GREAT ROOM
20
Blown
468 ft2
0.1
Wood
2
Under Attic (Unvented)
KITCHEN
20
Blown
329ft2
0.1
Wood
3
Under Attic (Unvented)
POOL BATH
20
Blown
36 ft2
0.1
Wood
4
Under Attic (Unvented)
M BATH
20
Blown
78 ft2
0.1
Wood
5
Under Attic (Unvented)
MASTER SUITE
20
Blown
224 ft2
0.1
Wood
6
Under Attic (Unvented)
M WIC
20
Blown
42 ft2
0.1
Wood
7
Under Attic (Unvented)
AHU
20
Blown
9 ft2
0.1
Wood
8
Under Attic (Unvented)
LINEN
20
Blown
9ft2
0.1
Wood
9
Under Attic (Unvented)
LAUNDRY
20
Blown
70 ft2
0.1
Wood
10
Under Attic (Unvented)
CLST 2
20
Blown
20 ft2
0.1
Wood
11
Under Attic (Unvented)
BEDROOM 2
20
Blown
168 ft2
0.1
Wood
12
Under Attic (U nvented)
HALLWAY
20
Blown
92ft2
0.1
Wood
13
Under Attic (Unvented)
STORAGE
20
Blown
30 ft2
0.1
Wood
14
Under Attic (Unvented)
STAIRS UP
20
Blown
74 ft2
0.1
Wood
15
Under Attic (Unvented)
WIC 4A
20
Blown
35 ft2
0.1
Wood
16
Under Attic (Unvented)
BEDROOM 4
20
Blown
196 ft2
0.1
Wood
17
Under Attic (Unvented)
WIC
20
Blown
50ft2
0.1
Wood
18
Under Attic (Unvented)
WIC 3
20
Blown
49ft2
0.1
Wood
19
Under Attic (Unvented)
LINEN UP
20
Blown
10 ft2
0.1
Wood
20
Under Attic (Unvented)
AC CHASE
20
Blown
4 ft2
0.1
Wood
21
Under Attic (Unvented)
LOFT
20
Blown
76ft2
0.1
Wood
22
Under Attic (Unvented)
BEDROOM 3
20
Blown
195 ft2
0.1
Wood
23
Under Attic (Unvented)
HALL BATH
20
Blown
88 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Below
SpaceArea
R-Va,
le Ftm.-qnr1
N
Exterior Concrete Block - Ext InSLGREAT ROO
9 18
0 10 0
180.0 ft2
0
0
0.6
0
2
W
Exterior Concrete Block - Ext InSLGREAT ROO
9 26
0 10 0
260.0 ft2
0
0
0.6
0
3
S
Exterior Concrete Block - Ext Insul KITCHEN
9 23
0 10 0
230.0 ft2
0
0
0.6
0
4
W
Exterior Concrete Block - Ext Insul KITCHEN
9 17
0 10 0
170.0 ft2
0
0
0.6
0
5
N
Exterior Concrete Block - Ext InsdPOOL BATH
9 6
0 10 0
60.0 ft2
0
0
0.6
0
6
N
Exterior Concrete Block - Ext InsWASTER SUI
9 14
0 10 0
140.0 ft2
0
0
0.6
0
1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUIl/dI1111ARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
S Pace
7
E
Exterior
Concrete Block - Ext InsdASTER SUI
9
7
0
10
0
70.0 ft2
0
0
0.6
0
8
E
Garage
Concrete Block - Ext InsWASTER SUI
9
9
0
10
0
90.0 ft2
0
0
0.6
0
9
E
Garage
Concrete Block- Ext Insul M W IC
9
6
0
10
0
60.0 ft2
0
0
0.6
0
10
E
Garage
Concrete Block - Ext Insul CLST 2
9
2
0
10
0
20.0 ft2
0
0
0.6
0
E
Exterior
Concrete Block - Ext InstMEDROOM 2
9
1
0
10
0
10.0 ft2
0
0
0.6
0
9-11
12
S
Exterior
Concrete Block - Ext InsLBEDROOM 2
9
15
0
10
0
150.0 ft2
0
0
0.6
0
13
E
Garage
Concrete Block - Ext InstMEDROOM 2
9
11
0
10
0
110.0 ft2
0
0
0.6
0
14
W
Exterior
Concrete Block - Ext InsuSTAIRS UP
9
15
0
10
0
150.0 ft2
0
0
0.6
0
15
S
Exterior
Concrete Block- Ext Insul WIC 4A
9
5
0
10
0
50.0 ft2
0
0
0.6
0
16
W
Exterior
Concrete Block- Ext Insul WIC 4A
9
7
0
10
0
70.0 ft2
0
0
0.6
0
17
E
Exterior
Concrete Block - Ext InstBEDROOM 4
9
14
0
10
0
140.0 ft2
0
0
0.6
0
18
S
Exterior
Concrete Block - Ext InstMEDROOM 4
9
14
0
10
0
140.0 ft2
0
0
0.6
0
19
E
Exterior
Concrete Block- Ext Insul WIC 4
9
5
0
10
0
50.0 ft2
0
0
0.6
0
_ 20
E
Exterior
Concrete Block- Ext Insul WIC 3
9
7
0
10
0
70.0 ft2
0
0
0.6
0
21
W
Exterior
Concrete Block - Ext Insul LOFT
9
4
0
10
0
40.0 ft2
0
0
0.6
0
22
N
Exterior
Concrete Block - Ext InstBEDROOM 3
9
13
0
10
0
130.0 ft2
0
0
0.6
0
23
E
Exterior
Concrete Block - Ext InstBEDROOM 3
9
15
0
10
0
150.0 ft2
0
0
0.6
0
24
N
Exterior
Concrete Block - Ext InsuHALL BATH
9
6
0
10
0
60.0 ft2
0
0
0.6
0
25
W
Exterior
Concrete Block - Ext InsuHALL BATH
9
15
0
10
0
150.0 ft2
0
0
0.6
0
26
E
Garage
Concrete Block - Ext InsuILAUNDRY
9
7
0
10
0
70.0 ft2
0
0
0.6
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated KITCHEN
None
.39
3
8
24 ft2
f
2
N
Insulated POOL BATH
None
.39
2
8
8
21.3 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Vinyl Low-E Single Yes
0.45
0.3
N
96.0 ft2
2 ft 0 in
1 ft 4 in
None
None
2
W 2
Vinyl Low-E Single Yes
0.45
0.25
N
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
3
S 3
Vinyl Low-E Single Yes
0.45
0.25
N
24.0 ft2
2 ft 0 in
1 ft 4 in
None
None
4
S 3
Vinyl Low-E Single Yes
0.45
0.25
N
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
W 4
Vinyl Low-E Single Yes
0.45
0.25
N
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
N 6
Vinyl Low-E Single Yes
0.45
0.3
N
64.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
E 7
Vinyl Low-E Single Yes
0.45
0.25
N
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
8
S 12
Vinyl Low-E Single Yes
0.45
0.25
N
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
9
E 17
Vinyl Low-E Single Yes
0.45
0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
10
S 18
Vinyl Low-E Single Yes
0.45
0.25
N
24.0 ft2
2 ft 0 in
1 ft 4 in
None
None
11
W 21
Vinyl Low-E Single Yes
0.45
0.25
N
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
12
N 22
Vinyl Low-E Single Yes
0.45
0.25
N
24.0 ft2
2 ft 0 in
1 ft 4 in
None
None
13
E 23
Vinyl Low-E Single Yes
0.45
0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 7
FORM R405-2017 INPUT SLIIlilMARY CHECKLIST DEPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
14
W 25 Vinyl Low-E Single Yes
0.45 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
i
805 ft2
805 ft2
35 ft loft 9
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 W holehouse Proposed ACH(50)
.000445
2744 150.64 283.3 .3446 7
HEATING SYSTEM
\77-#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Strip Heat/
None
COPA 34 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
SEER: 20 45.5 kBtu/hr 1365 cfm 0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Propane Tankless
Exterior
0.6 1 gal 55.1 gal 120 deg None
'
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
/
V #
---- Supply ----
Location R-Value Area
---- Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 250 ft2
Attic
25 ft2 Default Leakage AHU (Default) c(Default) c
1 1
1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 7
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat:
N
Ceiling Fans:
Coolingan Feb
HeatinJan HFeb
Mar
Mar
A r
Apr
Ma
Ma�
Jun
Jun
Jul
Jul
Auge
Au
Sep
Oct
Oct N
Nov
Nov
Dec
HDec
Ventin Jan
Feb
Mar
[X] Apr
[
May
[ Jun
[ Jul
[ Aug
[
Se
[X] Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (W EH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
'Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (W EH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM A
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2A
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2A
Default(8 ibs/sq.ft.
ft2
ft
0.3
KITCHEN/DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2A
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING A
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY A
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU CLST A
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL A
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH A
Default(8 Ibs/sq.ft.
•
ft2
ft
0.3
WIC A
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 213
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 26
" Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2B
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN/DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING B
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU CLST B
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY B
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL B
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC B
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH B
Default(8 Ibs/sq.ft
ft2
ft
0.3
BEDROOM B
Name:
Rating Compant:
h'�A;rf% I rrlr-ljl �rfyj
Date: `—,� I--Ifi
1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 7 of 7
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: HINKLE RESIDENCE Builder Name:
Street: 246 BIMINI DRIVE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
U
Owner: DON HINKLE Jurisdiction: ST LUCIE COUNTY
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA,
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
1/31/2019 9:43 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 86
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
45.5
a) Split system SEER
20.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2352
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.450
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.270
14. Heating system: Capacity
34.0
c) Area
7c.
392.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
0.0
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
0.60
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
9.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (Insulation R-value)
1062.
9.0
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
20.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: �(_/ wv Date:
Address of New Home: 246 BIMINI DRIVE City/FL Zip: FORT PIERCE, FL
1/31/2019 9:42:58 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1