Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Busin egulation - Residential Performance Method Project Name: HINKLE REST E wilder Name: Street: 246 BIMINI DR VE ermit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERC , FL, FEB 14 2019 rmit Number: Owner: DON HINKLE J risdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce Permitting D e p a rtm e n tc unty: St. Lucie (Florida Climate Zone 2 ) St' f 61. New construction or existing ewI Wall Types (2820.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=9.0 2470.00 ft2 b. Concrete Block - Ext Insul, Adjacent R=9.0 350.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2352.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2352.00 ft2 6. Conditioned floor area above grade (ft2) 2352 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows (392.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU 6 250 a. U-Factor: Sgl, U=0.45 232.00 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.45 160.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 45.5 SEER:20.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems a. Propane Tankless Cap: 1 gallonsEF: 8. Floor Types (2352.0 sqft.) Insulation Area 0.600 a. Slab -On -Grade Edge Insulation R=0.0 1575.00 ft2 b. Conservation features b. Raised Floor R=0.0 777.00 ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.167 Total Proposed Modified Loads: 75.02 PASS Total Baseline Loads: 87.47 I hereby certify that the plans and specifications covered by Review of the plans and FTE SrAr this calculation are in compliance with the Florida Energy specifications covered by this _ Code... calculation indicates compliance cq ii„ '` �'- �.��` VO `.'., with the Florida Energy Code. rrnrra.. ''��. •,;:€••;sw ;, PREPARED BY: DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 .. *. t n I hereby certify that this building, as designed, is in compliance the Florida Energ C de. Florida Statutes. �oD with W.6 OWNER/AGENT:. - 'I'Ll(� BUILDING OFFICIAL: DATE: Z 44 V l-9 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this pri an envelope leakage test report with envelope leakage no greater than 7.00.F/ACki50 SR4 .2 t;l L v FEB 1 4 2019 1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Softwar Permitting D e p a rtmage 1 of 7 St. Lucie County, FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: HINKLE RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2352 Lot # Owner Name: DON HINKLE Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 246 BIMINI DRIVE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2352 23520 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 GREAT ROOM 468 4680 No 0 1 Yes Yes Yes 2 KITCHEN 329 3290 Yes 0 1 Yes Yes Yes 3 POOL BATH 36 360 No 0 1 Yes Yes Yes 4 • M BATH 78 780 No 0 1 No Yes Yes 5 MASTER SUITE 224 2240 No 0 1 1 Yes Yes Yes 6 M WIC 42 420 No 0 1 No Yes Yes 7 AHU 9 90 No 0 1 No Yes Yes 8 LINEN 9 90 No 0 1 No Yes Yes 9 LAUNDRY 70 700 No 0 1 No Yes Yes 10 CLST 2 20 200 No 0 1 No Yes Yes 11 BEDROOM 2 168 1680 No 0 1 1 Yes Yes Yes 12 HALLWAY 92 920 No 0 1 No Yes Yes 13 STORAGE 30 300 No 0 1 No Yes Yes 14 STAIRS UP 74 740 No 0 1 Yes Yes Yes 15 WIC 4A 35 350 No 0 1 Yes Yes Yes 16 BEDROOM 4 196 1960 No 0 1 1 Yes Yes Yes 17 WIC 4 50 500 No 0 1 Yes Yes Yes 18 WIC 3 49 490 No 0 1 Yes Yes Yes 19 LINEN UP 10 100 No 0 1 No Yes Yes 20 AC CHASE 4 40 No 0 1 No Yes Yes 21 LOFT 76 760 No 0 1 Yes Yes Yes 22 BEDROOM 3 195 1950 No 0 1 1 Yes Yes Yes 1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT \ SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 23 HALL BATH 88 880 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation GREAT ROOM 44 ft 0 468 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulation KITCHEN 40 ft 0 329 ft2 ____ 1 0 0 e 3 Slab -On -Grade Edge Insulation POOL BATH 6 ft 0 36 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation M BATH 1 ft 0 78 ft2 ____ 1 0 0 5 Slab -On -Grade Edge Insulation MASTER SUITE 21 ft 0 224 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation M WIC 1 ft 0 42 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulation AHU 1 ft 0 9 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation LINEN 1 ft 0 9 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation LAUNDRY 1 ft 0 70 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation CLST 2 1 ft 0 20 ft2 1 0 0 11SIab-On-Grade Edge Insulation BEDROOM 2 16 ft 0 168 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 92 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation STORAGE 1 ft 0 30 ft2 ____ 1 0 0 14Raised Floor STAIRS UP ____ ____ 74 ft2 0 1 0 0 15Raised Floor WIC 4A ____ ____ 35 ft2 0 1 0 0 16Raised Floor BEDROOM 4 ____ 196 ft2 0 1 0 0 17Raised Floor WIC 4 ____ ____ 50 ft2 0 1 0 0 18Raised Floor WIC 3 ____ ____ 49 ft2 0 1 0 0 19Raised Floor LINEN UP ____ ____ 10 ft2 0 1 0 0 20Ralsed Floor AC CHASE ____ ____ 4 ft2 0 1 0 0 21Raised Floor LOFT ____ ____ 76 ft2 0 1 0 0 22Raised Floor BEDROOM 3 _-__ ____ 195 ft2 0 1 0 0 23Raised Floor HALL BATH ____ ____ 88 ft2 0 1 0 0 1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2017 INPUT bUIVIIVAKY UHLUKL1b I KLPUK ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2630 ft2 0 ft2 Light 0.6 No 0.9 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2352 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) GREAT ROOM 20 Blown 468 ft2 0.1 Wood 2 Under Attic (Unvented) KITCHEN 20 Blown 329ft2 0.1 Wood 3 Under Attic (Unvented) POOL BATH 20 Blown 36 ft2 0.1 Wood 4 Under Attic (Unvented) M BATH 20 Blown 78 ft2 0.1 Wood 5 Under Attic (Unvented) MASTER SUITE 20 Blown 224 ft2 0.1 Wood 6 Under Attic (Unvented) M WIC 20 Blown 42 ft2 0.1 Wood 7 Under Attic (Unvented) AHU 20 Blown 9 ft2 0.1 Wood 8 Under Attic (Unvented) LINEN 20 Blown 9ft2 0.1 Wood 9 Under Attic (Unvented) LAUNDRY 20 Blown 70 ft2 0.1 Wood 10 Under Attic (Unvented) CLST 2 20 Blown 20 ft2 0.1 Wood 11 Under Attic (Unvented) BEDROOM 2 20 Blown 168 ft2 0.1 Wood 12 Under Attic (U nvented) HALLWAY 20 Blown 92ft2 0.1 Wood 13 Under Attic (Unvented) STORAGE 20 Blown 30 ft2 0.1 Wood 14 Under Attic (Unvented) STAIRS UP 20 Blown 74 ft2 0.1 Wood 15 Under Attic (Unvented) WIC 4A 20 Blown 35 ft2 0.1 Wood 16 Under Attic (Unvented) BEDROOM 4 20 Blown 196 ft2 0.1 Wood 17 Under Attic (Unvented) WIC 20 Blown 50ft2 0.1 Wood 18 Under Attic (Unvented) WIC 3 20 Blown 49ft2 0.1 Wood 19 Under Attic (Unvented) LINEN UP 20 Blown 10 ft2 0.1 Wood 20 Under Attic (Unvented) AC CHASE 20 Blown 4 ft2 0.1 Wood 21 Under Attic (Unvented) LOFT 20 Blown 76ft2 0.1 Wood 22 Under Attic (Unvented) BEDROOM 3 20 Blown 195 ft2 0.1 Wood 23 Under Attic (Unvented) HALL BATH 20 Blown 88 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below SpaceArea R-Va, le Ftm.-qnr1 N Exterior Concrete Block - Ext InSLGREAT ROO 9 18 0 10 0 180.0 ft2 0 0 0.6 0 2 W Exterior Concrete Block - Ext InSLGREAT ROO 9 26 0 10 0 260.0 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Ext Insul KITCHEN 9 23 0 10 0 230.0 ft2 0 0 0.6 0 4 W Exterior Concrete Block - Ext Insul KITCHEN 9 17 0 10 0 170.0 ft2 0 0 0.6 0 5 N Exterior Concrete Block - Ext InsdPOOL BATH 9 6 0 10 0 60.0 ft2 0 0 0.6 0 6 N Exterior Concrete Block - Ext InsWASTER SUI 9 14 0 10 0 140.0 ft2 0 0 0.6 0 1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUIl/dI1111ARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below S Pace 7 E Exterior Concrete Block - Ext InsdASTER SUI 9 7 0 10 0 70.0 ft2 0 0 0.6 0 8 E Garage Concrete Block - Ext InsWASTER SUI 9 9 0 10 0 90.0 ft2 0 0 0.6 0 9 E Garage Concrete Block- Ext Insul M W IC 9 6 0 10 0 60.0 ft2 0 0 0.6 0 10 E Garage Concrete Block - Ext Insul CLST 2 9 2 0 10 0 20.0 ft2 0 0 0.6 0 E Exterior Concrete Block - Ext InstMEDROOM 2 9 1 0 10 0 10.0 ft2 0 0 0.6 0 9-11 12 S Exterior Concrete Block - Ext InsLBEDROOM 2 9 15 0 10 0 150.0 ft2 0 0 0.6 0 13 E Garage Concrete Block - Ext InstMEDROOM 2 9 11 0 10 0 110.0 ft2 0 0 0.6 0 14 W Exterior Concrete Block - Ext InsuSTAIRS UP 9 15 0 10 0 150.0 ft2 0 0 0.6 0 15 S Exterior Concrete Block- Ext Insul WIC 4A 9 5 0 10 0 50.0 ft2 0 0 0.6 0 16 W Exterior Concrete Block- Ext Insul WIC 4A 9 7 0 10 0 70.0 ft2 0 0 0.6 0 17 E Exterior Concrete Block - Ext InstBEDROOM 4 9 14 0 10 0 140.0 ft2 0 0 0.6 0 18 S Exterior Concrete Block - Ext InstMEDROOM 4 9 14 0 10 0 140.0 ft2 0 0 0.6 0 19 E Exterior Concrete Block- Ext Insul WIC 4 9 5 0 10 0 50.0 ft2 0 0 0.6 0 _ 20 E Exterior Concrete Block- Ext Insul WIC 3 9 7 0 10 0 70.0 ft2 0 0 0.6 0 21 W Exterior Concrete Block - Ext Insul LOFT 9 4 0 10 0 40.0 ft2 0 0 0.6 0 22 N Exterior Concrete Block - Ext InstBEDROOM 3 9 13 0 10 0 130.0 ft2 0 0 0.6 0 23 E Exterior Concrete Block - Ext InstBEDROOM 3 9 15 0 10 0 150.0 ft2 0 0 0.6 0 24 N Exterior Concrete Block - Ext InsuHALL BATH 9 6 0 10 0 60.0 ft2 0 0 0.6 0 25 W Exterior Concrete Block - Ext InsuHALL BATH 9 15 0 10 0 150.0 ft2 0 0 0.6 0 26 E Garage Concrete Block - Ext InsuILAUNDRY 9 7 0 10 0 70.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated KITCHEN None .39 3 8 24 ft2 f 2 N Insulated POOL BATH None .39 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.45 0.3 N 96.0 ft2 2 ft 0 in 1 ft 4 in None None 2 W 2 Vinyl Low-E Single Yes 0.45 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 3 S 3 Vinyl Low-E Single Yes 0.45 0.25 N 24.0 ft2 2 ft 0 in 1 ft 4 in None None 4 S 3 Vinyl Low-E Single Yes 0.45 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 5 W 4 Vinyl Low-E Single Yes 0.45 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 6 N 6 Vinyl Low-E Single Yes 0.45 0.3 N 64.0 ft2 2 ft 0 in 1 ft 4 in None None 7 E 7 Vinyl Low-E Single Yes 0.45 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 8 S 12 Vinyl Low-E Single Yes 0.45 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 9 E 17 Vinyl Low-E Single Yes 0.45 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 10 S 18 Vinyl Low-E Single Yes 0.45 0.25 N 24.0 ft2 2 ft 0 in 1 ft 4 in None None 11 W 21 Vinyl Low-E Single Yes 0.45 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 12 N 22 Vinyl Low-E Single Yes 0.45 0.25 N 24.0 ft2 2 ft 0 in 1 ft 4 in None None 13 E 23 Vinyl Low-E Single Yes 0.45 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 7 FORM R405-2017 INPUT SLIIlilMARY CHECKLIST DEPORT WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 14 W 25 Vinyl Low-E Single Yes 0.45 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation i 805 ft2 805 ft2 35 ft loft 9 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 W holehouse Proposed ACH(50) .000445 2744 150.64 283.3 .3446 7 HEATING SYSTEM \77-# System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 20 45.5 kBtu/hr 1365 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Exterior 0.6 1 gal 55.1 gal 120 deg None ' SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / V # ---- Supply ---- Location R-Value Area ---- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 250 ft2 Attic 25 ft2 Default Leakage AHU (Default) c(Default) c 1 1 1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Coolingan Feb HeatinJan HFeb Mar Mar A r Apr Ma Ma� Jun Jun Jul Jul Auge Au Sep Oct Oct N Nov Nov Dec HDec Ventin Jan Feb Mar [X] Apr [ May [ Jun [ Jul [ Aug [ Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 'Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (W EH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM A Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2A Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2A Default(8 ibs/sq.ft. ft2 ft 0.3 KITCHEN/DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2A Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING A Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY A Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU CLST A Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL A Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH A Default(8 Ibs/sq.ft. • ft2 ft 0.3 WIC A Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 213 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 26 " Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2B Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN/DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING B Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU CLST B Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY B Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL B Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC B Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH B Default(8 Ibs/sq.ft ft2 ft 0.3 BEDROOM B Name: Rating Compant: h'�A;rf% I rrlr-ljl �rfyj Date: `—,� I--Ifi 1/31/2019 9:42 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 7 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HINKLE RESIDENCE Builder Name: Street: 246 BIMINI DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner: DON HINKLE Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA, General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1/31/2019 9:43 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 86 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 45.5 a) Split system SEER 20.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2352 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.450 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.270 14. Heating system: Capacity 34.0 c) Area 7c. 392.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 0.0 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF 0.60 A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 9.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 1062. 9.0 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 20.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: �(_/ wv Date: Address of New Home: 246 BIMINI DRIVE City/FL Zip: FORT PIERCE, FL 1/31/2019 9:42:58 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1