GENERAL LIMITATIONS
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLockS Saff4sialing Ice i WaW Breriers
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shag be property ventilated in accordance with the FBC requirements.
6) All side lap seams shall be Installed to shed water from the deck.
7) The undedayment may be used as described in other currant FBC product approval documents.
6) Design wind load pressures !shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 611320-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 61h Edition (2017) as evidenced In the referenced documents submitted by the named manufacturer.
R,
-''V�:� '�� sF ':sue'•.
No 74021
,Ir
C�
�p0. STATE OF ;�14Z
4ri; ON A�S
t110.
���.
CERTIFICATION OF INDEPENDENCE
2017.10.11
09:06:29
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services. LLC does not have, nor will it aoquire, a financial interest Marry company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R, priest, P.E. does not have, nor will acquire, a financial Interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR1400Z8a 1.4 ` 97 11 Pagie 4 of 4
This evaluation report is provided for State or, FI 'F ` ' j a ar b manufacturer shall notify CREEK
Technical Services, LLC of any product changm qua r u`'" rya oa a nges ` roughout the duration for which this report is valid.
This evaluation report does not express nor implVwarranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Uec 14 2018 09:20AM HP Fax JA Taylor Roofing 7724688397
page 11
CREEK
TECHNICAL SERVICES. LLC
PRODUCT APPLICATION
OWENS CORNING ROOFING AND ASPHALT LLC
Weatheri.new Self-sealing ice a Water Barriers
Min. Roof Slope: 2:12 in accordance with the FBC
Application: All undedayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any frreguladlies and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to undertayment
application. Prior to beginning installation, the underlayment shelf be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the eave, starting at the save, and with minimum 3" sloe
laps and minimum 6" end laps staggered min. 64from preceding course. Additionally, if
applying Wealhert-ock® Specialty Tile $ Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 34 Inches across the width
of the lop.
It is permissible to back nail the undedayment 12-Inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally, Westherl-ock® Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Mtn. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application (temperature,
WINO RESISTANCE
The Maximum Design Pressures shown' below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Undedayment System No 1 — WeatherLock Specialty Tie &Metal Only
Roof Deck: Min.15/324nch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Undedayment WeatherLeekO Specialty Tile A Metal shall be applied in accordance with
manufacturees installation instructions to the fastened deck and backnatled along the
selvage with minimum 129a., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 329a. x 1-5/84nch 0 tin caps spaced 12" o.c. The applied
underlayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure.
FL9777-
3 of 4
r nrs evacuation report is provided for State of Fladda product approval under Rule 61020-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is vapid.
This evsluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Dec 14 2018 09:19AM HP Fax JA Taylor Roofing 7724688397 page 10
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
TECHNICAL SERVICES, LLC Weetherlocke Saif-Seeling ke a Water Sorriers
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLoek® G WeatherLock® G Is an ASTM D 1970 self-adhesive underlayment constructed from SBS
(Brentwood, NH) modified asphalt, a fiberglass met reinforcement and surfaced with granules. The
product is supplied In 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeetherLock@ G Is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLoek® Mat
(Brentwood. NH or
WeetherLack® Mat is an ASTM D 1970 self-adhesive uncladayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement. The is
Houston, 77t)
product supplied in 1-
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. roils with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLockO Mal is permitted to be used as prescribed in FBC Section 1607.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shag be limited to a
maximum 30 days.
WeatherLock® Metal
(Brentwood, NH)
WeatherLockil) Metal is an ASTM D 1970 self-adhesive underlayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement and film
plastic surface. The
product is supplied In 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeetherLocke Metal is permitted to be used as prescribed In FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days.
Weathercock®
Specialty Tile S Metal
WeatherLockO Specialty Tile S Metal is an ASTM D 1970 self-adhesive underayment
(Brentwood, NH or
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-i1.
Houston, 7X)
WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock® Specialty Tile & Metal is permitted to be used with
adhered day or concrete tge roofing using either ICP Adhesives Polyset A14-160 (ICP
Adhesives and Sealants, Inc.) or TILE BON07m Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with day or concrete the installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
Weatherl.ock@ G (High
Tear)
WeatherLockO G (High Tear) is a self -adhered, underlayment used as an altemative to
(Houston. 77q
ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer
modified bitumen underlayment. The underlayment is composed of SBS modified
asphalt with a fiberglass mat Internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-ft x 66 tt.
Weathert-oekS G (High Tear) Is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
' ' " % I I Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report C valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
uec '14 ?-U16 U919AM HP Fax JA Taylor Roofing 7724688397 page 9
CREEKCt3rt�cate of Authorrzation No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT
FLORIDA BUILDING CODE, C EDITION (2017)
Manufacturer.
OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017
1 Owens Coming Parkway
Toledo, OH 43657 ,
(800) 438-7465
www.owenscomina.com
Manufacturing Location:
Brentwood, NH
Houston, TX
Quality Assurance:
UL LLC (QUA9625)
Sam
Category:
Roofing
Subcategory:
Underiayments
Code Sections:
1504.3.1. 1507.1.1
Properties:
Physical properties
REFERENCES
EEntlty
PRI Construction Materials Technologies (TST5878)
Revort No.
NEI-039-02-01
Standard
ASTM D 1970
Year
2015
PRI Construction Materials Technologies (TST5878)
NEI-042-02-01REV2
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI.045-D2-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI.045-02-01
ASTM G 155
20063
PRI Construction Materials Technologies (TST5878)
NEI-053-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-053-D2-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
NEI-093-012-02
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-213.02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
OCF-237.02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF 252 02-01
ASTM D 4798
2001
PRI Construction Materials Technologies (TST6878)
OCF-252-02.01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
OCF-253-02-02
OCF-272-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-296-02-02
TAS 103
ICC-ES AC 188'
1995
2012
PRI Constnwtion Materials Technologies (TST5878)
OCF-297-02-01.1
IE-S AC 48
AS M o 970
2012
2015
PRI Construction Materials Technologies (TST5878)
OCFF318-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-329-02 01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
0CF-320-02-01
ASTM G 155
2005a
PRI Construction Materials Technobgies (1`ST5878)
PRI Construction Materials Technologies (TST5878)
OCF-321-02-01
OCF-322-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
'Determined
OCF-355-02-01
LL 1697
UL 1897
2012
2012
to be equivalent to ASTM D 226-09, Type 1 and II
rY V 1 VI Y
This evaluation report is provided for State of Florida productapproval under Rule 61020-3. The manufacturer shell notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor Imply warranty, installation, recommended use. or other product ratiributes that are not
Specifically addressed herein.