Loading...
HomeMy WebLinkAboutReview CommentsPlanning 8: Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 246 Bimini Dr City / State / Zip: Fort Pierce, FI 34949 Parcel #: 1425-701-0049-000/5 Zoning RS-4 ,APPLICATION INFORMATION Permit Number: 1901-0227 REVIEW COMMENTS Dfttin -1 Owner(s): Donald G Hinkle / Linda J Hinkle Jurisdiction: SAINT LUCIE COUNTY Lot#: 9 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR InIFORMA iON Contractor Name: Donald G Hinkle Business Name: Don Hinkle Construction Business Addr: 219 Hunt Ave City / State / Zip: Ft Pierce, FI 34946 REWEWS AND COMMENTS Revie--- w m Sty ADDRESSING ASSIGNMENT COMPLETE Comment: DOCUMENTS MISSING 1/17/2019 Comment: 1/18/2019 Comment: ENVIRONMENTAL REVIEW Comment: FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW 1/29/2019 Comment: 1/29/2019 Comment: Comment: 1/29/2019 Comment 1/29/2019 FEB 14 2019 Block: 3 Automatic Sprinkler System? No Number: 772-467-1348 IEmall: Donhinkle@Bellsouth.Net Permltt fra Drra—{-mnn . ✓L. L -ccie Y r1Lf Pik . it I Revie-- Wea B°Y Date Started Lori Bender 1/18/2019 PENDING Lashahna Ingram 1/11/2019 DRIVEWAY PERMIT APPL. FOR ROAD AND BRIDGE, VEG PERMIT FILED UNDER (H) FOR HINKLE. NO FEE. COMPLETE Lynn Swartzel 1/15/2019 COMPLETE Lashahna Ingram 1/11/2019 PENDING William Durden Date Completed 1/18/2019 1/18/2019 1/11/2019 Date Released 1/18/2019 1/18/2019 1/11/2019 - NOA NUMBER 14-0416.01 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING. - PLEASE SUBMIT GEOTECHNICAL REPORT WITH RECOMMENDATIONS FOR THE PILES DEPTHS, SIZING, ETC., IN COMPLIANCE WITH R401 OF THE 2017 RESIDENTIAL BUILDING CODE. PLEASE SEE PAGES 3 AND 5 OF 6. FOUNDATION PLANS BY CAPSTONE DO NOT REFLECT THE INSTALLATION OF PILES AS INDICATED BY PAUL WELCH. PLEASE CORRECT AND SUBMIT SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. PLEASE SEE PAGES 3 AND 5 OF 6. FOUNDATION PLANS BY CAPSTONE DO NOT REFLECT THE FOUNDATION OR SLAB AS INDICATED BY PAUL WELCH FOR THE STRUCTURAL SLAB. PLEASE CORRECT AND SUBMIT SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. i Planning g CDevelopmentdeReRegulation Divces ision REVIEW COMMENTS Building 8 Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462-6443 1/29/2019 raaC L Comment: • SEE ACI 318 TABLE 4.2.2 REQUIREMENTS FOR SPECIAL EXPOSURE CONDITIONS, CONCRETE SUBJECTED TO BRAKISH OR SALT WATER MINIMUM 5000 PSI CONCRETE. PLEASE CORRECT DRAWINGS SIGNED AND SEALED SUBMITTED IN DUPLICATE. 1/29/2019 Comment: • PLEASE SUBMIT THE ELEVATION OF THE INVERT FOR THE SEPTIC SYSTEM. THIS IS REQUIRED FOR DETERMINATION OF THE ELEVATION AND REQUIREMENTS FOR STORM WATER. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE, AND SECTION 7.04.01 (D) OF THE LAND DEVELOPMENT CODE. ADDITIONAL REVIEW COMMENTS MAY BE REQUIRED. 1/2912019 Comment: PLEASE SEE LINTELS SCHEDULE ON PAGE 2 OF 6. MULTIPLE LINTELS SPECIFIED ON SCHEDULE NOT PERTAINING TO SITE -SPECIFIC PROJECT. PLEASE REMOVE OR STRIKETHROUGH NOT USED TO ANY INFORMATION FROM THE PLANS THAT DO NOT PERTAIN TO THE SITE -SPECIFIC PROJECT. PLEASE SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 1/29/2019 Comment: • LINE TEN ON THE ENERGY CALC'S ARE INCORRECT, PLANS CALL OUT R-30. PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE EDITION. ENERGY CONSERVATION 6TH 1/29/2019 Comment: • LINE SEVEN ON THE ENERGY CALC'S ARE INCORRECT, MULTIPLE TYPES AND SIZES OF GLAZED OPENINGS ON PLANS. PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. 1/29/2019 Comment: • PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING THE SQUARE FOOT INFORMATION OR A LETTER FROM THE DESIGN PROFESSIONAL SPECIFYING THE CUBIC VOLUME OF THE CONDITIONED SPACE. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 1/29/2019 Comment: • LINE NINE ON THE ENERGY CALC'S ARE INCORRECT, PLANS CALL OUT R-4. PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE EDITION. ENERGY CONSERVATION 6TH 1/29/2019 Comment: • PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX FOR WALL AND CEILING FINISHES IN ACCORDANCE WITH SECTION 302.9 OF THE 2017 FLORIDA 1/29/2019 RESIDENTIAL CODE. Comment: - PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS REQUIRED IN SECTION 302.10 OF THE 2017 FLORIDA RESIDENTIAL 1/29/2019 CODE. Comment: • PLEASE ADD TO THE SIGNED AND SEAL CONSTRUCTION DOCUMENTS THE INFORMATION THAT IS REQUIRED BY CHAPTER 3, SECTION R322, AND SUB -SECTION R322.3.6 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. 1/29/2019 Comment: • PLEASE SHOW ON THE PLANS THE ELEVATION OF THE MECHANICAL PADS MEETING THE REQUIREMENTS OF CHAPTER 3, SECTION R322, SUB -SECTION R322.1.6 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. 1/29/2019 Comment: • PLEASE FURNISH A INTERIOR STAIR DETAIL SHOWING STAIR WIDTH, HEADROOM, RISER HEIGHT, TREAD DEPTH, HAND RAIL HEIGHT AND GRIP SIZE IN ACCORDANCE WITH SECTION R311.7 AND R312 OF THE 2017 FLORIDA RESIDENTIAL CODE. 1/2912019 Comment: • THE TRUSS ENGINEERING OR THE TRUSS PLACEMENT DRAWINGS MUST BE REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL IN CHARGE. PLEASE CORRECT AND SUBMIT IN DUPLICATE. IN ACCORDANCE WITH 61 G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE. AND CHAPTER 8 SECTION R802 SUBSECTION R802.1.7.1 OF THE 2017 FLORIDA RESIDENTIAL 1/29/2019 BUILDING CODE. Comment: - PLEASE NOTE THAT THE COMMENTS ARE FOR CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING 1/29/2019 CORRECTED DOCUMENTS. Comment: • ALL DOCUMENTS SUBMITTED FOR PERMITTING MUST BE IN DUPLICATE. ANY DOCUMENTS THAT REQUIRES A SIGNATURE OR SEAL MUST BE SUBMITTED IN DUPLICATE WITH ORIGINAL SEALS AND SIGNATURES. PLEASE SEE THE 2017 FLORIDA BUILDING CODE CHAPTER 1, SUBSECTION 107.1. ZONING REVIEW COMPLETE Lydia Galbraith 1/17/2019 1/22/2019 1/22/2019 Comment: