HomeMy WebLinkAboutReview CommentsPlanning 8: Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
PROPERTY INFORMATION
Address: 246 Bimini Dr
City / State / Zip: Fort Pierce, FI 34949
Parcel #: 1425-701-0049-000/5
Zoning
RS-4
,APPLICATION INFORMATION
Permit Number: 1901-0227
REVIEW COMMENTS
Dfttin -1
Owner(s):
Donald G Hinkle / Linda J Hinkle
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 9
Stories:
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
CONTRACTOR InIFORMA iON
Contractor Name: Donald G Hinkle
Business Name: Don Hinkle Construction
Business Addr: 219 Hunt Ave
City / State / Zip: Ft Pierce, FI 34946
REWEWS AND COMMENTS
Revie--- w m Sty
ADDRESSING ASSIGNMENT COMPLETE
Comment:
DOCUMENTS MISSING
1/17/2019 Comment:
1/18/2019 Comment:
ENVIRONMENTAL REVIEW
Comment:
FRONT COUNTER REVIEW
Comment:
PLANS EXAMINER REVIEW
1/29/2019 Comment:
1/29/2019 Comment:
Comment:
1/29/2019
Comment
1/29/2019
FEB 14 2019
Block: 3
Automatic Sprinkler System? No
Number: 772-467-1348
IEmall: Donhinkle@Bellsouth.Net
Permltt fra Drra—{-mnn .
✓L. L -ccie Y r1Lf Pik . it I
Revie-- Wea B°Y Date Started
Lori Bender 1/18/2019
PENDING Lashahna Ingram 1/11/2019
DRIVEWAY PERMIT APPL. FOR ROAD AND BRIDGE,
VEG PERMIT FILED UNDER (H) FOR HINKLE. NO FEE.
COMPLETE Lynn Swartzel 1/15/2019
COMPLETE Lashahna Ingram 1/11/2019
PENDING William Durden
Date Completed
1/18/2019
1/18/2019
1/11/2019
Date Released
1/18/2019
1/18/2019
1/11/2019
- NOA NUMBER 14-0416.01 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS.
SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING.
- PLEASE SUBMIT GEOTECHNICAL REPORT WITH RECOMMENDATIONS FOR THE PILES DEPTHS, SIZING,
ETC., IN COMPLIANCE WITH R401 OF THE 2017 RESIDENTIAL BUILDING CODE.
PLEASE SEE PAGES 3 AND 5 OF 6. FOUNDATION PLANS BY CAPSTONE DO NOT REFLECT THE
INSTALLATION OF PILES AS INDICATED BY PAUL WELCH. PLEASE CORRECT AND SUBMIT SEE SECTION
107 OF THE 2017 FLORIDA BUILDING CODE.
PLEASE SEE PAGES 3 AND 5 OF 6. FOUNDATION PLANS BY CAPSTONE DO NOT REFLECT THE
FOUNDATION OR SLAB AS INDICATED BY PAUL WELCH FOR THE STRUCTURAL SLAB. PLEASE CORRECT
AND SUBMIT SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE.
i
Planning g CDevelopmentdeReRegulation
Divces
ision
REVIEW COMMENTS
Building 8 Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(772)462-2172 Fax:(772)462-6443
1/29/2019
raaC L
Comment: • SEE ACI 318 TABLE 4.2.2 REQUIREMENTS FOR SPECIAL EXPOSURE CONDITIONS, CONCRETE
SUBJECTED TO BRAKISH OR SALT WATER MINIMUM 5000 PSI CONCRETE.
PLEASE CORRECT DRAWINGS
SIGNED AND SEALED SUBMITTED IN DUPLICATE.
1/29/2019
Comment: • PLEASE SUBMIT THE ELEVATION OF THE INVERT FOR THE SEPTIC SYSTEM. THIS IS REQUIRED FOR
DETERMINATION OF THE ELEVATION AND REQUIREMENTS FOR
STORM WATER. SEE SECTION 107 OF
THE 2017 FLORIDA BUILDING CODE, AND SECTION 7.04.01 (D) OF THE LAND DEVELOPMENT CODE.
ADDITIONAL REVIEW COMMENTS MAY BE REQUIRED.
1/2912019
Comment: PLEASE SEE LINTELS SCHEDULE ON PAGE 2 OF 6. MULTIPLE LINTELS SPECIFIED ON SCHEDULE NOT
PERTAINING TO SITE -SPECIFIC PROJECT. PLEASE REMOVE OR
STRIKETHROUGH NOT USED TO ANY
INFORMATION FROM THE PLANS THAT DO NOT PERTAIN TO THE SITE -SPECIFIC PROJECT. PLEASE SEE
SECTION 107 OF THE 2017 FLORIDA BUILDING CODE.
1/29/2019
Comment: • LINE TEN ON THE ENERGY CALC'S ARE INCORRECT, PLANS CALL OUT R-30. PLEASE CORRECT ENERGY
CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE
EDITION. ENERGY CONSERVATION 6TH
1/29/2019
Comment: • LINE SEVEN ON THE ENERGY CALC'S ARE INCORRECT, MULTIPLE TYPES AND SIZES OF GLAZED
OPENINGS ON PLANS. PLEASE CORRECT ENERGY CALC'S AS PER
SECTION R401.3 OF THE 2017 FLORIDA
BUILDING CODE ENERGY CONSERVATION 6TH EDITION.
1/29/2019
Comment: • PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING
THE SQUARE FOOT INFORMATION OR A LETTER FROM THE DESIGN
PROFESSIONAL SPECIFYING THE
CUBIC VOLUME OF THE CONDITIONED SPACE. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA
BUILDING CODE.
1/29/2019
Comment: • LINE NINE ON THE ENERGY CALC'S ARE INCORRECT, PLANS CALL OUT R-4. PLEASE CORRECT ENERGY
CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE
EDITION. ENERGY CONSERVATION 6TH
1/29/2019
Comment: • PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX FOR WALL AND CEILING
FINISHES IN ACCORDANCE WITH SECTION 302.9 OF THE 2017 FLORIDA
1/29/2019
RESIDENTIAL CODE.
Comment: - PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS
REQUIRED IN SECTION 302.10 OF THE 2017 FLORIDA RESIDENTIAL
1/29/2019
CODE.
Comment: • PLEASE ADD TO THE SIGNED AND SEAL CONSTRUCTION DOCUMENTS THE INFORMATION THAT IS
REQUIRED BY CHAPTER 3, SECTION R322, AND SUB -SECTION R322.3.6
OF THE 2017 FLORIDA
RESIDENTIAL BUILDING CODE.
1/29/2019
Comment: • PLEASE SHOW ON THE PLANS THE ELEVATION OF THE MECHANICAL PADS MEETING THE
REQUIREMENTS OF CHAPTER 3, SECTION R322, SUB -SECTION R322.1.6
OF THE 2017 FLORIDA
RESIDENTIAL BUILDING CODE.
1/29/2019
Comment: • PLEASE FURNISH A INTERIOR STAIR DETAIL SHOWING STAIR WIDTH, HEADROOM, RISER HEIGHT,
TREAD DEPTH, HAND RAIL HEIGHT AND GRIP SIZE IN ACCORDANCE
WITH SECTION R311.7 AND R312 OF
THE 2017 FLORIDA RESIDENTIAL CODE.
1/2912019
Comment: • THE TRUSS ENGINEERING OR THE TRUSS PLACEMENT DRAWINGS MUST BE REVIEWED AND
APPROVED BY THE DESIGN PROFESSIONAL IN CHARGE. PLEASE
CORRECT AND SUBMIT IN DUPLICATE.
IN ACCORDANCE WITH 61 G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE. AND CHAPTER 8 SECTION
R802 SUBSECTION R802.1.7.1 OF THE 2017 FLORIDA RESIDENTIAL
1/29/2019
BUILDING CODE.
Comment: - PLEASE NOTE THAT THE COMMENTS ARE FOR CLARIFICATION OR CORRECTION OF THE SUBMITTED
DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING
1/29/2019
CORRECTED DOCUMENTS.
Comment: • ALL DOCUMENTS SUBMITTED FOR PERMITTING MUST BE IN DUPLICATE. ANY DOCUMENTS THAT
REQUIRES A SIGNATURE OR SEAL MUST BE SUBMITTED IN DUPLICATE
WITH ORIGINAL SEALS AND
SIGNATURES. PLEASE SEE THE 2017 FLORIDA BUILDING CODE CHAPTER 1, SUBSECTION 107.1.
ZONING REVIEW
COMPLETE Lydia Galbraith 1/17/2019 1/22/2019 1/22/2019
Comment: