HomeMy WebLinkAboutenegy calcFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -Residential Performance Method Project Name: Street: City, State, Zip: Owner: Design Location: HODSON RESIDENCE 571 NETTLES BLVD JENSEN BEACH , FL , FL, Fort Pierce 1. New construction or existing 2 . Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) 7. Windows(1 19.0 sqft.) Description a. LI-Factor: Sgl , U=0.28 SHGC: SHGC=0 .22 b . LI-Factor: N/A SHGC : c. LI-Factor: N/A SHGC: d. LI -Factor: N/A SHGC: Area Weighted Average Overhang Depth : Area Weighted Average SHGC: New (From Plans) Detached 2 No 875 0 Area 119.00 ft2 ft2 ft2 ft2 1.000 ft. 0.220 8. FloorTypes (875 .0 sqft.) a. Slab-On-Grade Edge Insulation Insulation R=0.0 Area 875.00 ft2 ft2 b. N/A R= c. N/A R= ft2 Builder Name: MEL-RY CONSTRUCTION, INC . Permit Office: ST LUCIE COUNTY Permit Number: Jurisdiction : ST LUCIE COUNTY County: St. Lucie (Florida Climate Zone 2 ) 9 . Wall Types (1024 .7 sqft.) a. Concrete Block -Int lnsul, Exterior b. N/A c. N/A d. N/A 10. Ceiling Types (875 .0 sqft.) a. Roof Deck (Unvented) b. N/A c. N/A 11 . Ducts a . Sup: Attic, Ret: Attic , AH : Attic 12 . Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits Insulation Area R=4.1 1024.70 ft2 R= ft2 R= ft2 R= ft2 Insulation Area R=20 .0 875 .00 ft2 R= ft2 R= ft2 R ft2 6 125 kB tu/hr Efficiency 18.8 SEER :16.00 kBtu/hr Efficiency 17.0 COP :1.00 Cap : 50 gallons EF: 0 .980 None Glass/Floor Area: 0 .136 Total Proposed Modified Loads: 34.35 PASS Total Baseline Loads: 37.99 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy COOe PREPARED BY: , DATE: 5-13-202 I hereby certify that this building, as de;ig ~,)s in compliance with the Florida Energy C . cff OWNER/AGENT:._ . ._f-...,....--.J..---1--------- DATE: -----=--++---f!"-f--,f-:n--------- Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code . Before construction is completed this building will be inspected for compliance with Section 553 .908 Florida Statutes. BUILDING OFFICIAL: DATE: -Compliance requ i res certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1 .2). 5/13/2021 2 :35 PM EnergyGaugeA@ USA 6 .0 .02 (Rev. 1) -FlaRes2017 FBC 6th Ed ition (2017) Compliant Software Page 1 of 5