HomeMy WebLinkAboutenegy calcFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation -Residential Performance Method
Project Name:
Street:
City, State, Zip:
Owner:
Design Location:
HODSON RESIDENCE
571 NETTLES BLVD
JENSEN BEACH , FL ,
FL, Fort Pierce
1. New construction or existing
2 . Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft2)
Conditioned floor area below grade (ft2)
7. Windows(1 19.0 sqft.) Description
a. LI-Factor: Sgl , U=0.28
SHGC: SHGC=0 .22
b . LI-Factor: N/A
SHGC :
c. LI-Factor: N/A
SHGC:
d. LI -Factor: N/A
SHGC:
Area Weighted Average Overhang Depth :
Area Weighted Average SHGC:
New (From Plans)
Detached
2
No
875
0
Area
119.00 ft2
ft2
ft2
ft2
1.000 ft.
0.220
8. FloorTypes (875 .0 sqft.)
a. Slab-On-Grade Edge Insulation
Insulation
R=0.0
Area
875.00 ft2
ft2 b. N/A R=
c. N/A R= ft2
Builder Name: MEL-RY CONSTRUCTION, INC .
Permit Office: ST LUCIE COUNTY
Permit Number:
Jurisdiction : ST LUCIE COUNTY
County: St. Lucie (Florida Climate Zone 2 )
9 . Wall Types (1024 .7 sqft.)
a. Concrete Block -Int lnsul, Exterior
b. N/A
c. N/A
d. N/A
10. Ceiling Types (875 .0 sqft.)
a. Roof Deck (Unvented)
b. N/A
c. N/A
11 . Ducts
a . Sup: Attic, Ret: Attic , AH : Attic
12 . Cooling systems
a. Central Unit
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
Insulation Area
R=4.1 1024.70 ft2
R= ft2
R= ft2
R= ft2
Insulation Area
R=20 .0 875 .00 ft2
R= ft2
R= ft2
R ft2
6 125
kB tu/hr Efficiency
18.8 SEER :16.00
kBtu/hr Efficiency
17.0 COP :1.00
Cap : 50 gallons
EF: 0 .980
None
Glass/Floor Area: 0 .136 Total Proposed Modified Loads: 34.35 PASS Total Baseline Loads: 37.99
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
COOe
PREPARED BY: ,
DATE: 5-13-202
I hereby certify that this building, as de;ig ~,)s in compliance
with the Florida Energy C . cff
OWNER/AGENT:._ . ._f-...,....--.J..---1---------
DATE: -----=--++---f!"-f--,f-:n---------
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code .
Before construction is completed
this building will be inspected for
compliance with Section 553 .908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
-Compliance requ i res certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1 .2).
5/13/2021 2 :35 PM EnergyGaugeA@ USA 6 .0 .02 (Rev. 1) -FlaRes2017 FBC 6th Ed ition (2017) Compliant Software Page 1 of 5