Loading...
HomeMy WebLinkAboutEnergy Codea0/2-oz'j,� FORM R405-2020 FILE COPY ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index, the more efficient the home. 7106 Paso Robles Blvd, , FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple famlly Detached a. Block, Exterior R=4.1 1096.00 ft2 b. Frame - Wood, Adjacent R=13.0 304.00 ft2 3. Number of units, if multiple family 1 c. N/A R= f12 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation Insulation Area level R=30.0 1449.00 ft2 6. Conditioned floor area (W) 1449 a. Under Attic (Vented) R= ft2 7. Windows" Description Area b. WA R= ftzc. a. U Factor: Dbl, U=0.35 105.00 ft2 N/A 12. Ducts, location & insulation R ft2 6 289.8 SHGC: SHGC=0.29 level b. U-Factor: N/A ft2 a. Sup: Attic, Ret: Main, AH: Main SHGC: kBtu/hr Efficiency c. U-Factor: N/A ft2 22.2 SEER:14.50 SHGC: 13. Cooling systems d. U-Factor: N/A ft2 a. Central Unit SHGC: kBtu/hr Efficiency 22.2 HSPF:8.20 Area Weighted Average Overhang Depth: 9 9 9 P 1.857 ft. 14. Heating systems Area Weighted Average SHGC: 0.290 a. Electric Heat Pump 8. Skylights Description Area Cap: 50 gallons a. U-Factor(AVG): N/A ft2 15. Hot water systems EF: 0.92 SHGC(AVG): N/A a. Electric 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1449.00 ft2 b '� ro e 'ation'featur " Cred'�$or4ormance meiod) Pstat b. N/A R= ft2 Ilvvo e c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature:: Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. *`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FILE COPX as FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 7106 Paso Robles Blvd - 1449 B LHG - S Builder Name: Wade Jurney Homes Street: ' 7106 Paso Robles Blvd Permit Office: Port St. Lucie City, State, Zip: , FL, Permit Number: Owner: Jurisdiction: 66100 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1400.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Block, Exterior R=4.1 1096.00 ft2 b. Frame - Wood, Adjacent R=13.0 304.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1449.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1449.00 ft2 6. Conditioned floor area above grade (ft2) 1449 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(105.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Main, AH: Main R ft2 6 289.8 a. U-Factor: Dbl, U=0.35 105.00 ft2 SHGC: SHGC=0.29 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 22.2 SEER:14.50 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth:. 1.857 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.290 a. Electric Heat Pump 22.2 HSPF:6.20 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1449.0 sgft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1449.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.072 Total Proposed Modified Loads: 41.71 PASS SS Total Baseline Loads: 44.02 /'1�7�7 I hereby certify that the plans and specifications covered by in Florida Energy Review of the plans and by -tu..E STA. this calculation are compliance with the specifications covered this �Y�� _ : , 0� Code. calculation indicates compliance Florida Energy Code. q` ��,;''' = �a�q�. •� F•r rryn r i PREPARED BY: ¢��%�' ��.�-,.. DATE: _._ ___.____ 02/02/2021 __ with the Before construction is completed this building will be inspected for . • i p t compliance with Section 553.908 * I hereby certify that this buildi s designed, is "n compliance Florida Statutes. with the Florida Energy'LiCj COD Wtiu OWNER/AGENT: BUILDING OFFICIAL: _ DATE.- DATE. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 2/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM.R4052020 ]NP.UT-SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: 7106 Paso Robles Blvd - 144 User 1 Wade Jurney Homes Port St. Lucie 66100 Detached New (From Plans) Bedrooms: 4 Conditioned Area: 1449 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: Lakewood Park PlatBook: Street: 7106 Paso Robles Blvd County: St. Lucie City, State, Zip: FL, CLIMATE / Design Location TMY Site Design Temp 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH AIRPORT 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1449 11592 SPACES Number Name Area Volume. Kitchen Occupants Bedrooms InfillD Finished Cooled Heated 1 Main 1449 11592 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type :Space Perimeter R-Value Area Tile Wood Carpet . 1 Slab -On -Grade, Edge Insulatio Main 137 ft 0 1449 ft2 _ 0.29 0 0.71 ROOF 1/ # Type Materials Roof Gable Roof Area Area Color , Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1527 ft2 242 ft2 Dark N 0.4 N 0.4 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area FIBS IRCC 1 Full attic Vented 300 1449 ft2 N N CEILING # 'Geiptig.Type Space: R Value Ins Type• Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1449 ft2 0.1 Wood 2/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 IINPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space P Cavity Width Height Sheathing Framing Solar Below nrnt i+irauTyoe R-Value• R In Fi In Area-R Value-Fractipn _Absor'_Gradeo/ 1 N Exterior Block Main 4.1 37 0 8 0 296.0 ft2 0 0.25 0.4 0 2 E Exterior Block Main 4.1 50 6 8 0 404.0 ft2 0 0.25 0.4 0 3 S Exterior Block Main 4.1 16 6 8 0 132.0 ft2 0 0.25 0.4 0 4 W Exterior Block Main 4.1 33 0 8 0 264.0 ft2 0 0.25 0.4 0 _ 5 Garage Frame - Wood Main 13 38 0 8 0 304.0 ft2 0 0.25 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .4 2 8 6 8 17.8 ft2 2 S Insulated Main None .4 3 6 8 20 ft2 3 - Wood Main None :46 2 a 6 8 17.8 ft2 WINDOWS Orientation. shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.35 0.29 N 45.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 2 E 2 Vinyl Low-E Double Yes 0.35 0.29 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 3 S 3 Vinyl Low-E Double Yes 0.35 0.29 N 30.0 ft2 4 ft 0 in 1 ft 0 in Drapes/blinds None 4 W 4 Vinyl Low-E Double Yes 0.35 0.29 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 418ft2 418ft2 46ft 8ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1352.4 74.5 139.3 .1263 7 HEATING SYSTEM # System Type Subtype ,Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.2 22.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 14.522.2 kBtu/hr 666 cfm 0.75 1 sys#1 2/2/2021 10:42 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPLIT SUMMARY CHFCKI-IST REPORT HOT WATER SYSTEM # Systerti-Type SubType Location EF :Cap. Use SetPnt Conservation 1 Electric None Main 0.92 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS / — Supply ---- ---- Return _ Air CFM 25 CFM25 HVAC # V/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 289.8 ft Main 72.45 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cool' Jan Heatinf X� Jan Feb f X� Feb Mar Mar Apr f Apr f May Jun Jul May 4 Jun f Jul Au f AuE Se SeP E } Oct Oct Nov f X� Nov Dec f X� Dec Venting[ ]Jan [ j Feb Mar [X] Apr [ M8 [ Jun [ Jul [ Aug [ Se [Xl Oct [X] Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6r 7 8 .9, 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 76 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/s .ft. 0 ft2 0 ft 0.3. Main 2/2/2021 10:42 AM EnergyGaugeO USA 7.0.00 - FlaR i s2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4