HomeMy WebLinkAboutEnergy Codea0/2-oz'j,�
FORM R405-2020
FILE COPY
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 95
The lower the EnergyPerformance Index, the more efficient the home.
7106 Paso Robles Blvd, , FL,
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple famlly
Detached
a. Block, Exterior
R=4.1
1096.00 ft2
b. Frame - Wood, Adjacent
R=13.0
304.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
f12
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation
Insulation
Area
level
R=30.0
1449.00 ft2
6. Conditioned floor area (W)
1449
a. Under Attic (Vented)
R=
ft2
7. Windows" Description
Area
b. WA
R=
ftzc.
a. U Factor: Dbl, U=0.35
105.00 ft2
N/A
12. Ducts, location & insulation
R ft2
6 289.8
SHGC: SHGC=0.29
level
b. U-Factor: N/A
ft2
a. Sup: Attic, Ret: Main, AH: Main
SHGC:
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
22.2 SEER:14.50
SHGC:
13. Cooling systems
d. U-Factor: N/A
ft2
a. Central Unit
SHGC:
kBtu/hr
Efficiency
22.2
HSPF:8.20
Area Weighted Average Overhang Depth:
9 9 9 P
1.857 ft.
14. Heating systems
Area Weighted Average SHGC:
0.290
a. Electric Heat Pump
8. Skylights Description
Area
Cap: 50 gallons
a. U-Factor(AVG): N/A
ft2
15. Hot water systems
EF: 0.92
SHGC(AVG): N/A
a. Electric
9. Floor Types
Insulation
Area
a. Slab -On -Grade Edge Insulation
R=0.0
1449.00 ft2
b '� ro e 'ation'featur "
Cred'�$or4ormance meiod)
Pstat
b. N/A
R=
ft2
Ilvvo e
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:: Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
*`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FILE COPX
as
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 7106 Paso Robles Blvd - 1449 B LHG - S
Builder Name: Wade Jurney Homes
Street: ' 7106 Paso Robles Blvd
Permit Office: Port St. Lucie
City, State, Zip: , FL,
Permit Number:
Owner:
Jurisdiction: 66100
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type$1400.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Block, Exterior
R=4.1 1096.00 ft2
b. Frame - Wood, Adjacent
R=13.0 304.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1449.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1449.00 ft2
6. Conditioned floor area above grade (ft2) 1449
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(105.0 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ft2
6 289.8
a. U-Factor: Dbl, U=0.35 105.00 ft2
SHGC: SHGC=0.29
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
22.2 SEER:14.50
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth:. 1.857 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.290
a. Electric Heat Pump
22.2 HSPF:6.20
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1449.0 sgft.) Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation R=0.0 1449.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.072 Total Proposed Modified Loads: 41.71
PASS
SS
Total Baseline Loads: 44.02
/'1�7�7
I hereby certify that the plans and specifications covered by
in Florida Energy
Review of the plans and
by
-tu..E STA.
this calculation are compliance with the
specifications covered this
�Y�� _ : , 0�
Code.
calculation indicates compliance
Florida Energy Code.
q` ��,;''' = �a�q�. •�
F•r rryn r i
PREPARED BY: ¢��%�' ��.�-,..
DATE: _._ ___.____ 02/02/2021 __
with the
Before construction is completed
this building will be inspected for
. • i p
t
compliance with Section 553.908
*
I hereby certify that this buildi s designed, is "n compliance
Florida Statutes.
with the Florida Energy'LiCj
COD Wtiu
OWNER/AGENT:
BUILDING OFFICIAL: _
DATE.-
DATE.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
2/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM.R4052020 ]NP.UT-SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
7106 Paso Robles Blvd - 144
User
1
Wade Jurney Homes
Port St. Lucie
66100
Detached
New (From Plans)
Bedrooms: 4
Conditioned Area: 1449
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type: Street Address
Lot #
Block/Subdivision: Lakewood Park
PlatBook:
Street: 7106 Paso Robles Blvd
County: St. Lucie
City, State, Zip:
FL,
CLIMATE
/
Design Location TMY Site
Design Temp
97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH AIRPORT 39 90
70 75 299 62 Low
BLOCKS
Number
Name Area
Volume
1
Blockl 1449
11592
SPACES
Number
Name Area Volume. Kitchen Occupants
Bedrooms InfillD Finished Cooled Heated
1
Main 1449 11592 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type :Space
Perimeter R-Value
Area Tile Wood Carpet .
1 Slab -On -Grade, Edge Insulatio Main
137 ft 0
1449 ft2 _ 0.29 0 0.71
ROOF
1/ #
Type Materials
Roof Gable Roof
Area Area Color ,
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles
1527 ft2 242 ft2 Dark
N 0.4 N 0.4 No 0 18.4
ATTIC
V #
Type Ventilation Vent Ratio (1 in)
Area FIBS IRCC
1
Full attic Vented
300 1449 ft2 N N
CEILING
#
'Geiptig.Type
Space: R Value Ins Type• Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1449 ft2 0.1 Wood
2/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 IINPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
P
Cavity Width
Height
Sheathing Framing Solar Below
nrnt
i+irauTyoe
R-Value• R In Fi
In Area-R
Value-Fractipn _Absor'_Gradeo/
1 N
Exterior Block
Main
4.1 37 0 8
0 296.0 ft2
0 0.25 0.4
0
2 E
Exterior Block
Main
4.1 50 6 8
0 404.0 ft2
0 0.25 0.4
0
3 S
Exterior Block
Main
4.1 16 6 8
0 132.0 ft2
0 0.25 0.4
0
4 W
Exterior Block
Main
4.1 33 0 8
0 264.0 ft2
0 0.25 0.4
0
_ 5
Garage Frame - Wood
Main
13 38 0 8
0 304.0 ft2
0 0.25 0.4
0
DOORS
#
Ornt Door Type
Space
Storms
U-Value
Width Height
Area
Ft
In Ft In
1
N Insulated
Main
None
.4 2
8 6 8
17.8 ft2
2
S Insulated
Main
None
.4 3
6 8
20 ft2
3
- Wood
Main
None
:46 2
a 6 8
17.8 ft2
WINDOWS
Orientation. shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID Frame Panes
NFRC
U-Factor SHGC Imp
Area Depth
Separation Int Shade
Screening
1
N 1 Vinyl Low-E Double Yes
0.35 0.29 N
45.0 ft2 1 ft 0 in
1 ft 0 in Drapes/blinds
None
2
E 2 Vinyl Low-E Double Yes
0.35 0.29 N
15.0 ft2 1 ft 0 in
1 ft 0 in Drapes/blinds
None
3
S 3 Vinyl Low-E Double Yes
0.35 0.29 N
30.0 ft2 4 ft 0 in
1 ft 0 in Drapes/blinds
None
4
W 4 Vinyl Low-E Double Yes
0.35 0.29 N
15.0 ft2 1 ft 0 in
1 ft 0 in Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
418ft2
418ft2
46ft
8ft
1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000356
1352.4 74.5 139.3 .1263
7
HEATING SYSTEM
#
System Type
Subtype
,Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
Split
Singl HSPF:8.2
22.2 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 14.522.2 kBtu/hr 666 cfm 0.75 1
sys#1
2/2/2021 10:42 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPLIT SUMMARY CHFCKI-IST REPORT
HOT WATER SYSTEM
#
Systerti-Type
SubType
Location
EF :Cap.
Use
SetPnt
Conservation
1
Electric
None
Main
0.92 50 gal
70 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ftz
DUCTS
/
— Supply ----
---- Return _
Air
CFM 25
CFM25
HVAC #
V/ #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 289.8 ft Main
72.45 ft Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cool' Jan
Heatinf X� Jan
Feb
f X� Feb
Mar
Mar
Apr
f Apr f
May Jun Jul
May 4 Jun f Jul
Au
f AuE
Se
SeP
E }
Oct
Oct
Nov
f X� Nov
Dec
f X� Dec
Venting[ ]Jan
[ j Feb
Mar
[X] Apr [
M8 [ Jun [ Jul
[ Aug
[ Se
[Xl
Oct
[X] Nov
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6r
7
8
.9,
10
11
12
Cooling (WD)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
76
78
78
78
78
78
Cooling (WEH)
AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/s .ft.
0 ft2
0 ft
0.3.
Main
2/2/2021 10:42 AM EnergyGaugeO USA 7.0.00 - FlaR i s2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4