Loading...
HomeMy WebLinkAboutAPPROVED Design Pressure Report (Linda Collins) - Galeforce Hurricane Shutters 06Ad& I'da W&UAPrce HURRICANE SHUTTERS, INC. PANELS • ACCORDIONS • BAHAMAS COLONIALS • ROLL UPS Property Information Building Information Owner: Linda Collins Wind Zone: 170 MPH. Address: 8105 Kiawah Trace Exposure Category: B Port St Lucie,FL 34986 Minimum Building Dimension: 5 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 183 111 7 25.8 -28.4 2 Int 85.5 69 7 28.3 -31.0 3 Int 62.75 69 7 28.9 -31.6 4 Int 7 28.9 -31.6 5 Int 7 28.9 -31.6 6 Int 7 28.9 -31.6 7 Int 43.25 44 7 30.6 -33.2 8 Int 196 111 7 25.7 -28.3 Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code. Page 1 of 1