Property Information Building Information
Owner: Linda Collins Wind Zone: 170 MPH.
Address: 8105 Kiawah Trace Exposure Category: B
Port St Lucie,FL 34986 Minimum Building Dimension: 5 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 183 111 7 25.8 -28.4
2 Int 85.5 69 7 28.3 -31.0
3 Int 62.75 69 7 28.9 -31.6
4 Int 7 28.9 -31.6
5 Int 7 28.9 -31.6
6 Int 7 28.9 -31.6
7 Int 43.25 44 7 30.6 -33.2
8 Int 196 111 7 25.7 -28.3
Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code.