Loading...
HomeMy WebLinkAboutAPPROVED Door NOA FL22513.2 HVHZ +70 -70 PSF 1/27/2021 Florida Building Code Online Business & Professional Regulation BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search bpr a Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail �OFFICEOFTHE FL# FL22513-R3 SECRETARY Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Masonite International Address/Phone/Email 1955 Powis Road West Chicago,IL 60185 (800)663-3667 sschreiber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 11/06/2020 Date Validated 11/09/2020 Date Pending FBC Approval https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEOwOhYDnHI%2bvKgHKCWn2WNgFPQkSTNA%3d%3d 1/3 1/27/2021 Florida Building Code Online Date Approved 11/17/2020 Summary of Products FL# Model,Number or Name Description 22513.1 HPC Wood-edge Steel Side-Hinged 6'-8"Glazed I/S or O/S Single or Double Door w/or w/o Door Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R3 C CAC NI013747.01-R2.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2025 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R3 II FL0212.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 6'-8"max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system is required. FL22513 R3 AE 514008B.pdf Door top rails stamped"HPC". See DWG-MA-FL0212 for details. Created by Independent Third Party: Yes 22513.2 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S or O/S Single Door Unit Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R3 C CAC NI013747.04-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2025 Design Pressure: +70/-70 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R3 II FL0215.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 3'-0"x 8'-0" max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not FL22513 R3 AE 514009B.pdf required. See DWG-MA-FL0215 for details. Created by Independent Third Party: Yes 22513.3 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S Single or Double Door w/or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R3 C CAC NI013747.04-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2025 Design Pressure: +45/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R3 II FL0215.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not required FL22513 R3 AE 514007B.pdf on opaque panels, but is required on glazed sidelites. See Created by Independent Third Party: Yes DWG-MA-FL0215 for details. 22513.4 Wood-edge Steel Side-Hinged Door 8'-0"Opaque O/S Single or Double Door w/or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R3 C CAC NI013747.04-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2025 Design Pressure: +50/-45 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R3 II FL0215.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not required FL22513 R3 AE 514007B.pdf on opaque panels, but is required on glazed sidelites. See Created by Independent Third Party: Yes DWG-MA-FL0215 for details. 22513.5 Wood-edge Steel Side-Hinged Door 8'-0"3/4-Lite Glazed I/S or O/S Single or Double Door w/or Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R3 C CAC NI013747.06-Rl.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2025 Design Pressure: +40/-40 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R3 II FL0217.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system is required. FL22513 R3 AE 514007B.pdf See DWG-MA-FL0217 for details. Created by Independent Third Party: Yes 22513.6 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S or O/S Single Door https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEOwOhYDnHI%2bvKgHKCWn2WNgFPQkSTNA%3d%3d 2/3 1/27/2021 Florida Building Code Online Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R3 C CAC NIO13747-R2.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2025 Design Pressure: +70/-70 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R3 II FL0211.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 3'-0"x 6'-8" max nominal size.When impact Evaluation Reports resistance is required, hurricane protective system not FL22513 R3 AE 514010B.pdf required. See DWG-MA-FL0211 for details. Created by Independent Third Party: Yes 22513.7 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S or O/S Single or Double Door w/or w/o Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R3 C CAC NIO13747-R2.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2025 Design Pressure: +55/-55 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R3 II FL0211.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 6'-8"max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not required FL22513 R3 AE 514008B.pdf on opaque panels, but is required on glazed sidelites. See Created by Independent Third Party: Yes DWG-MA-FL0211 for details. 22513.8 Wood-edge Steel Side-Hinged Door 6'-8"3/4-Lite Glazed I/S or O/S Single or Double Door w/or Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R3 C CAC NIO13747.03-R2.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2025 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R3 II FL0214.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 6'-8"max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system is required. FL22513 R3 AE 514008B.pdf See DWG-MA-FL0214 for details. Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® OJ ON eCheck Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEOwOhYDnHI%2bvKgHKCWn2WNgFPQkSTNA%3d%3d 3/3 NOTICE OF PRODUCT CERTIFICATION CERTIPIO (�.1 q�qt Company: Masonite International Corporation Certification No.: NI013747.04-R1 R" �*�'A�CR FQ ��z�• ''7,f 1955 Powis Road Certification Date: 06/08/2017 ®� West Chicago,IL 60185 Expiration Date: 06/30/2025 N Revision Date: 07/27/2020 R Product: Wood-Edge Steel Opaque Inswing or Outswing Door w/Non-Impact Rated Sidelites ti '4��F.tilEriT\N5�^ cF �ra a P (w/Wood Frame unless noted) .:. Specification: TAS 201/202/203-94 Impact: Large Missile Impact Rated Non-Impact Glazing: Insulating Glass (Tempered) The"Notice of Product Certification"is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www.Namicertification.com. NAMI's Certification Pro ram is accredited by The American National Standards Institute(ANSI). Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number& Outswing Opaque Size Pressure Pressure Rated Comments X I/S Opaque 3'0"x 810" +70/-70 0.0 psf Yes ATLNC 1001.01-13 Single Maximum Panel Size:3'0"x 8'0" Anchor Details-DWG-MA-FL0215-17 X O/S Opaque 390"x 810" +70/-70 0.0 psfl Yes ATLNC 1001.01-13/CTLA 919W Single Maximum Panel Size:3'0"x 8'0" 10.5 psf z Anchor Details-DWG-MA-FL0215-17 XX I/S Opaque 6'0"x 8'0" +45/-50 0.0 psf Yes ATLNC 0113.01-15 Double Maximum Panel Size:3'0"x 8'0" Anchor Details-DWG-MA-FL0215-17 XX O/S Opaque 6'0"x 8'0" +50/45 0.0 psf Yes ATLNC 0113.01-15 Double Maximum Panel Size:3'0"x 8'0" Anchor Details-DWG-MA-FL0215-17 XO/OX I/S Opaque Door 690"x 810" +45/-50 0.0 psf Door-Yes ATLNC 0113.01-15 Single w/Sidelite Glazed Sidelite Sidelite-No Maximum Panel Size:3'0"x 8'0"/Sidelite:3'0"x 8'0" Anchor Details-DWG-MA-FL0215-17 XO/OX O/S Opaque Door 690"x 810" +50/45 0.0 psf" Door-Yes ATLNC 0113.01-15 Single w/Sidelite Glazed Sidelite Sidelite-No Maximum Panel Size:3'0"x 8'0"/Sidelite:3'0"x 8'0" Anchor Details-DWG-MA-FL0215-17 OXO I/S Opaque Door 990"x 8'0" +45/-50 0.0 psf Door-Yes ATLNC 0113.01-15 Single w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size:3'0"x 8'0"/Sidelite:3'0"x 8'0" Anchor Details-DWG-MA-FL0215-17 OXO O/S Opaque Door 990"x 8'0" +50/45 0.0 psf" Door-Yes ATLNC 0113.01-15 Single w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size:3'0"x 8'0"/Sidelite:3'0"x 8'0" Anchor Details-DWG-MA-FL0215-17 OXXO I/S Opaque Door 1294"x 810" +451-50 0.0 psf Door-Yes ATLNC 0113.01-15 Double w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size:3'0"x 8'0"/Sidelite:3'0"x 8'0" Anchor Details-DWG-MA-FL0215-17 OXXO O/S Opaque Door 1TV x 810" +50/45 0.0 psfl Door-Yes ATLNC 0113.01-15 Double w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size:3'0"x 8'0"/Sidelite:3'0"x 8'0" Anchor Details-DWG-MA-FL0215-17 1-Denotes Bumper Outswing Threshold 2-Hi-Dam Outswing Threshold National Accreditation&Management Institute,Inc./4794 George Washington Memorial Highway/Hayes,VA 23072 Tel: (804)684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE: L. Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville,NC 27023 Report#: 514009B 434-688-0609 Date: 10/10/2017 rllomas(j�lrlomaspe.com Test Report: N/A Product: Single door 3'x8'(Wood Frame) Scope: This analysis provides calculations,quantities,and spacing requirements for installing product to substrate,and it applies only to the product described herein.These calculations comply with requirements of the Florida Building Code 7th edition(2020). Anchor capacity in shear condition: Solid members w/$w/out gap: a. With threads present in shear plane Fastener type:#10 wood screw (NOS 2018,TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: Or: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fyb= 80,000 psi Side member: Douglas Fir-Larch(G=0.50) Main member: Spruce-Pine-Fir(G=0.42) Side member thickness: t,= 1.000 in Main member thickness: tm= 1.500 in Side member dowel bearing strength: Fes= 4,650 psi Main member dowel bearing strength: FQ,= 3,350 psi Side member dowel bearing length: Is= 1.000 in Main member dowel bearing length: Im= 1.140 in Mode I, Mode I, Mode II Mode III, Mode III, Mode IV qm= 636.5 Ibs/in qs= 884 Ibs/in A: 0.0007 A: 0.00096 A: 0.00107 A: 0.00135 P= 725.61 Ibs P= 884 Ibs B: 1.07 B: 0.57 B: 0.5 B: 0.000 Kp= 2.400 Kp= 2.400 C: -427.674 C: -253.623 C: -267.699 C: -93.6 Zm= 302 Ibs Z,= 368 Ibs P= 331 Ibs Ms= 46.8 in-Ibs Mm= 46.8 in-Ibs Ko= 2.400 P= 297 Ibs P= 319 Ibs P= 263 Ibs Min.Design value: Z= 110 Ibs Z= 138 Ibs Kp= 2.400 Kp= 2.400 Kp= 2.400 Duration Factor: Cp= 1.6 Z= 124 Ibs Z= 133 Ibs Z= 110 Ibs Allowable Design Value(ZCo): Z'= 175 Ibs/anchor Fastener type: 1/4 ITW Tapcon Tabulated values N.O.A.16-1222.06 edge spacing(in) Substrate: Hollow block distance 2.00 4.00 Minimum embedment: 1.25 in 2.00 130 161 Actual edge distance: 2.50 in 4.00 163 202 Actual C To C spacing: 3.00 in Allowable Design Value: Z"= 155 Ibs/anchor(per interpolation when needed) Fastener type: #10 Tek screw Substrate: 18 GA,Steel Tabulated design value: Z= 1266 Ibs Safety factor: Fs= 4 Allowable Design Value(ZFs): Z.= 316 Ibs/anchor Minimum anchor capacity: 155 Ibs/anchor Note:Anchors with the least capacity is used for calculations to qualify anchors with higher capacity. Anchor calculations,minimum required anchors 36.38 Design pressure: 70.0 psf Area Load Ind. Max. Anchor Al Zone z O.C. Cap. Load Result 95.25 (ft) (Ibs) (in) (in) (Ibs) QtY (Ibs) A2 A, 2.3 161 N/A N/A 155 2 80 OK Aj AZ 9.7 681 6.00 18.00 155 6 114 OK "Z. . �ENS *� 0 51 , .GATE OF _ �[rr ONAL}E ��`� Luis R. Lomas P.E. FL No.: 62514 1 of 3 9/2/2020 L. Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville,NC 27023 Report#: 514009B 434-688-0609 Date: 10/10/2017 rllomas(a�lrlomaspe.com Anchor Locations: 36.38 18.19 6.00 TYP. 6.00 1 8" MAX O.C. 95.25 6.00 NN *� 0 51 , 'GATE OF _ �[rr ���isiONAL}E0\�`� it Luis R. Lomas P.E. FL No.: 62514 2 of 3 9/2/2020 L. Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville,NC 27023 Report#: 514009B 434-688-0609 Date: 10/10/2017 rllomas(j�lrlomaspe.com Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE#10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4"MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4"TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4"MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE#10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2"MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A.WOOD:MINIMUM SPECIFIC GRAVITY OF G=0.42 B.CONCRETE:MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C.MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PS1 MINIMUM. D.METAL STRUCTURE:STEEL 18GA(.048")FY=33KS1/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .052"THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. 7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE.FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2"UNITS MUST BE ANCHORED THROUGH FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY,CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 10. WHERE WOOD BUCK THICKNESS IS 1-1/2"OR GREATER,BUCK SHALL BE SECURELY FASTENED TO MASONRY,CONCRETE OR OTHER STRUCTURAL SUBSTRATE.UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE.SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. NN *� 0 51 , .GATE OF _ �Cr[rr Luis R. Lomas P.E. FL No.: 62514 3 of 3 9/2/2020 00 MASONITE® c WOOD-EDGE STEEL DOOR UNIT o Q C° " MAX. OVERALL FRAME WIDTH 8'-0"DOUBLE DOOR WITH/WITHOUT SIDELITES 149 z � J 21" MAX 36.375" MAX. O D.L.O. - PANEL WIDTH 37.5" MAX. P 07 FRAME WIDTH O GENERAL NOTES W/ASTRAGAL Z 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO cc Z U THE FLORIDA BUILDING CODE AND WHERE PRESSURE CL REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM _ DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES LISTED. � � U 2. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION _ Z � OR THE HIGH VELOCITY HURRICANE ZONE (HVHZ), coU)HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED ON OPAQUE P14 N QLd PANELS, BUT IS REQUIRED ON SIDELITES. 3. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 W AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. = Q = W 4. PLASTICS TESTING: O Z TEST DESCRIPTION DESIGNATION LITE FRAME rn a SELF IGNITION TEMP ASTM D1929 740 'F > 650 'F RATE OF BURNING ASTM D635 0.77 IN MIN E)U H SMOKE DENSITY ASTM D2843 13.4% TENSILE STRENGTH* ASTM D638 7.1% DIFF C:l o ouj m W * COMPARATIVE TENSILE STRENGTH AFTER WEATHERING :tlW W 4500 HOURS XENON ARC METHOD 1 000 I V)-� W oo alas WQgzza3 O O a- FLI 3 m RelfwMe DOUBLE DOOR UN IV WZSIDELITES a ® ® ® ® ® ® ® ® ® ® ® ® ® ® o _O U �p W • Ile 0 -0 • O • • • 1-11 N W SINGLE DOOR UNIT DOUBLE DOOR UNIT SINGLE DOOR Up4rT SINGLE DOOR UNIT SINGLE DOOR UNIT W/SIDELITES DOUBLE DOOR N SID LITES WITH SIDELITE WITH SIDELITE Q z WHERE WATER INFILTRATION PERFORMANCE IS DATE: 5/26�1] DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE TABLE OF CONTENTS CONFIG MAX WIDTH INSWING OUTSWING INSWING BUMPER 0 S Z-SERIES 0 S HIGH DAM 0 S SCALE: N.T.S. SHEET # DESCRIPTION X 37.5' +70.0 -70.0 +70.0 -70.0 N/A N A N/A +70.0 -70.0 DWG. BY: SWS 1 TYPICAL ELEVATIONS & GENERAL NOTES XX 74 +45.0 -50.0 +50.0 -45.0 N A N A N A N/A 2 ANCHORING LOCATIONS & DETAILS OX or XO 75 +45.0 -50.0 +50.0 -45.0 N/A N A N LA N A CHK. BY: 3 ANCHORING LOCATIONS & DETAILS OXO 112.5 +45.0 4 -50.0 +50.0 4 -45.0 N A N A N A N A KURT 13ALTHAZOR DRAWING NO.: OXXO 149 +45.0 -50.0 1 +50.0 -45.0 N/A N A N/A N/A FLORIDA P.E. DWG-MA-FL0215-17 #56533 SHEET _L OF 3 6" SEE DETAIL 'g" � 3„ 3" "E" 3 6„ 6„ � DO O p 6„ 6„ 6" 6„ I F O =1 in 3„ i0 I. LnLo -cc (n O NIA — n1 ^N Euj O Q a + can W _ } SEE DETAIL J J „D" c� Z) co — — w O cil L li N L�.I W 0' W T - N 0 Off O -' � U B g g SEE DETAIL ,� CC, 'SEE „C„ r = o� zo 04 N O �W O O m O W 6„ 3„ _ �y GO W ``' z � o i = � or � 6„ 6" 6" Woo a = I I I I I I I ^� — > > • o O Q o co 3 3„ f o 3„ � 3,> � 3„ � 6" 6„ ��I a � 6"3" SEE DETAIL 3"6" #8 x 2,. I m "F" ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE #8 x 2" #10 x 5/8" STRUCTURE DEEP ENOUGH FOR A 1 .375 THROW #10 x 5/8*" ; DETAIL "E" ASTRAGAL _DETAIL "F" ASTRArnL z #8 x 2" #10 x 1 " ATTACH ASTRAGAL RETAINER BOLT O #10 x 2-1/210 x 1 " STRIKE PLATE TO FRAME w AS SHOWN.#10 x 5/8 DETAIL "C" DETAIL "D" w a HOT MELT 1 0.962"11 ELASTOMER�� 1.375" � #6 x 1-1/2" PHS T T INSWING THRESHOLD z BUMPER O/S THRESHOLD HOT MELT �� : ,. 1/2" BITE ELASTOMER .v $ DATE: 5126117 fpg,. 1 SCALE: N.T.S. " EXTERIOR INTERIOR DWG. BY: $WS 1.482" 1.75 ;;73�11-047- TYPICAL GLAZING DETAIL CHK. BY: TIF! T NON—IMPACT GLASS DRAWING NO.: Z—SERIES O/S THRESHOLD HIGH DAM OZS THRESHOLD DWG-MA-FL0215-17 SHEET 2 OF 3 Ad*xk n to No Lc) 6ertif No.:. CL c0 SEE DETAIL How"oBf. O C) "E" SHT. 2 oa1B: 6" 6„ J CO 6" 3" 3 3" 3„ 6„3„ co 3„ J „ Si O c -J Il II 1 11 II I ZOO ff " —f " ! + ui ( �6 6 6" 6"� �-I W O Q _ � U Lo 3" 3" (o Z � z N I- N L U Li o W L{) r^ (/) v l Q W SEE DETAIL < a a "D" SHT. 2 M D — Liw io N w bi D_ it of W cz, J B B B O W p m 41 0 W W Z SEE DETAIL �_ A "C" SHT. 2 O= — a U N �3 ( (; M . p o Q 3" 3" _ p co � o 6" 6" — f 6" 6" } CL a I I I f I I I I I ILu } 3" 3„ 6'3„ 3„ _I 3„ 3�, f" 3 i O �l SEE DETAIL �I "F" SHT. 2 6„ 6" U w G✓ ATTACHMENT DETAIL 1.25"MIN , ° $ O 0.25" O 1 . ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, MAX o SIGNED AND SEALED BY LUIS R. LOMAS, PE SHIM HARDWARE SCHEDULE w (FLORIDA #62514) WITH THE LOWEST (LEAST) CL �� �-- 1 . KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND a FASTENER RATING FROM THE DIFFERENT FASTENERS 'x:�: BEING CONSIDERED FOR USE. JAMB, HEAD, AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE AT 10-1/2" CENTERLINE. TYPICAL MASONRY o #10 WOOD SCREWS OR 1/4 TAPCONS. A PHYSICAL ANCHOR INSTALLATION 2. 4 X 4 0 FULL MORTISE BUTT HINGES. °0 SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". WOOD SCREW EDGE DISTANCE MIN 3 4". a e. 1"X1/2" CORRUGATED #10X2" WOOD SCREW / 1.50" 3" FROM EACH END 6 FROM EACH END (3) #10X2-1/2" 2. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM MIN AND 7" OC AND 12" OC WO D SCREWS z 0.25 EACH END ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT I no SMAX HIM ` J ACRYLIC OF 1 -1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE I CAULK ® DATE: 5126117 MINIMUM EMBEDMENT OF 1 -1 4". CL/ yi ACRYLIC + SCALE: N.T.S. LATEX DWG. BY: SWS 3. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO :` CAULK CL 1 CHK. BY: TRANSFER LOADS TO STRUCTURE. TYPICAL WOOD BUCK COMBINATION WOOD COMBINATION WOOD INTEGRAL WOOD DRAWING NF 4. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. ANCHOR INSTALLATION MULLION (BOXED) MULLION (BOXED) MULLION (CHS) DWG—MA— LO215-17 SHEET 3 OF 3