Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Wright Residence Builder Name: Street: 6400 Koblegaurd Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34961 Permit Number: Owner. James Wright Jurisdiction: St. Lucie County Design Location: ' FL, Fort Pierce County: St. Lucie (Florida Climate zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41938.9 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Polystyrene Bead AgGR=0.0 1724.30 fta b. Frame - Wood, Adjacent R=11.0 214.67 fta 3. Number of units, if multiple family 1 c. N/A R= fta 4. Number of Bedrooms 2 d. N/A R= fta 5. Is this a worst case? No 11. Ceiling Types (1718.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1718.00 ft a 6. Conditioned floor area above grade (fta) 1718 b. N/A R= fta Conditioned floor area below grade (fta) 0 c. N/A R= fta 7. Windows(448.0 sqft.) Description Area 12. Ducts a. Sup: Living, Ret: AHU, AH: AHU R fta 6 80 a. U-Factor: Sgl, U=0.65 232.00 fta SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 216.00 fta 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 34.2 SEER:16.00 c. U-Factor. N/A fta SHGC: Weighted Average Overhang Depth: 7.799 ft. 14. Heating systems kBtu/hr EfficiencyArea Area Weighted Average SHGC: 0.274 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor(AVG) N/A fta 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1718.0 sgft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1718.00 fta b. Conservation features b. N/A R= fta None c. N/A R= fta 16. Credits CF, Pstat Total Proposed Modified Loads: 58.30 Glass/Floor Area: 0.261 PASS Total Baseline Loads: 58.36 1 hereby certify that the plans and specifications covered by Review of the plans and F'tHE STAp this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance y `,.=��..� rs+ with the Florida Energy Code. %Ihrr''+• "-•'',i �O Bxx' PREPARE�D4-9-L DATE: b 1 Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD yyg'i�� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested In accordance with ANSI/RESNET/ICC 380, Is not greater than 0,030 Qn for whole house. 2101'oX_3s 4/9/2021 9:47 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Comp '`an Eig anVpm §bage 1 of 6 FORM-R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Wright Residence Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1718 Lot # Owner Name: James Wright Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 6400 Koblegaurd Road Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.6 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1718 17643.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Laundry 60 564 No 0 1 Yes Yes Yes 2 Dining 198 2257.2 No 0 1 Yes Yes Yes 3 Kitchen 276 3146.4 Yes 1 1 Yes Yes Yes 4 AHU 12 112.8 No 0 1 No Yes Yes 5 Bedroom 2 231 2171.4 No 0 1 1 Yes Yes Yes 6 Bath 2 72 676.8 No 0 1 No Yes Yes 7 M Bath 120 1128 No 0 1 Yes Yes Yes 8 Toilet 28 263.2 No 0 1 Yes Yes Yes 9 WIC 80 752 No 0 1 Yes Yes Yes 10 Master Bedroom 340 3196 No 0 1 1 Yes Yes Yes 11 Hall 28 263.2 No 0 1 No Yes Yes 12 Living 273 3112.2 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Laundry 3 ft 60 ft2 1 0 0 2 Slab -On -Grade Edge Insulatio Dining 16 ft 198 ft2 1 0 0 3 Slab -On -Grade Edge Insulatio Kitchen loft 276 ft2 1 0 0 4 Slab -On -Grade Edge Insulatio AHU 1 8 12 ft2 1 0 0 5 Slab -On -Grade Edge Insulatio Bedroom 2 $6 ft 231 ft2 ___ 1 0 0 4/9/2021 9:47 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 F.ORM, R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Stab -On -Grade Edge Insulatio Bath 2 1 ft 72 ft2 1 0 0 7 Slab -On -Grade Edge Insulatio M Bath 12 ft 120 ft2 1 0 0 8 Slab -On -Grade Edge Insulatio Toilet 5 ft 28 W ____ 1 0 0 9 Slab -On -Grade Edge Insulatio WIC loft 80 ft2 _W 1 0 0 10SIab-On-Grade Edge Insulatio Master Bedroom 48 ft 340 ft2 ___ 1 0 0 11SIab-On-Grade Edge Insulatio Hall 1 ft 28 ft2 -__- 1 0 0 12SIab-On-Grade Edge Insulatio Living 31 ft 273 ft2 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insui. (deg) 1 Hip Metal 1921 ft2 0 ft2 Light N 0.6 No 0.9 No 20 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1718 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Laundry 0 Blown 60 ft2 0.1 Wood 2 Under Attic (Unvented) Dining 0 Blown 198 ft2 0.1 Wood 3 Under Attic (Unvented) Kitchen 0 Blown 276 ft2 0.1 Wood 4 Under Attic (Unvented) AHU 0 Blown 12 ft2 0.1 Wood 5 Under Attic (Unvented) Bedroom 2 0 Blown 231 ft2 0.1 Wood 6 Under Attic (Unvented) Bath 2 0 Blown 72 ft2 0.1 Wood 7 Under Attic (Unvented) M Bath 0 Blown 120 ft2 0.1 Wood 8 Under Attic (Unvented) Toilet 0 Blown 28 ft2 0.1 Wood 9 Under Attic (Unvented) WIC 0 Blown 80 ft2 0.1 Wood 10 Under Attic (Unvented) Master Bedroom 0 Blown 340 ft2 0.1 Wood 11 Under Attic (Unvented) Hall 0 Blown 28 ft2 0.1 Wood 12 Under Attic (Unvented) Living 0 Blown 273 ft2 0.1 Wood WALLS Adjacent a amt To Wall Type Space Cavity Width Height Sheathing Framing Solar Below 1 S Exterior Concrete Block - Polystyrelmundry 0 3 0 9 5 28.3 ft2 0 0 0.3 0 _ 2 N Exterior Concrete Block - PolystyrerDining 0 16 0 11 5 182.7 ft2 0 0 0,3 0 _ 3 W Exterior Concrete Block - PolystyreKitchen 0 10 0 11 5 114.2 ft2 0 0 0.3 0 4 N Exterior Concrete Block - Polysty8rdroom 2 0 17 0 9 5 160.1 ft2 0 0 0,3 0 4/9/2021 9:47 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS nrnf Adjacent Sin ToWall Typepace Cavity Width Height Et Sheathing Framing Walup Solar Below 'mde% _ 5 E Exterior Concrete Block - Polysty&droom 2 0 15 0 9 5 141.3 ft2 0 0 0.3 0 _ 6 S Exterior Concrete Block - Polystyftedroom 2 0 1 0 9 5 9.4 ft2 0 0 0,3 0 _ 7 W Exterior Concrete Block - Polystyrtdroom 2 0 3 0 9 5 28.3 ft2 0 0 0.3 0 8 E Exterior Concrete Block - PolystyreM Bath 0 12 0 9 5 113.0 W 0 0 0.3 0 _ 9 N Exterior Concrete Block - PolystyrenToilet 0 1 0 9 5 9.4 ft2 0 0 0.3 0 10 E Exterior Concrete Block - PolystyrenToilet 0 4 0 9 5 37.7 ft2 0 0 013 0 11 E Exterior Concrete Block - PolystyrenWIC 0 10 0 9 5 94.2 ft2 0 0 0,3 0 _ 12 E Exterior Concrete Block - Polystpeater Bedro 0 17 0 9 5 160.1 ft2 0 0 0.3 0 _ 13 S Exterior Concrete Block - Polyst1dester Bedro 0 17 0 9 5 160.1 ftz 0 0 0.3 0 14 W Exterior Concrete Block - Polystpeeter Bedro 0 14 0 9 5 131.8 ft2 0 0 0.3 0 _ 15 S Exterior Concrete Block - PolystyrerLiving 0 18 0 11 5 205.5 ft2 0 0 0,3 0 16 W Exterior Concrete Block - Polystyrert-iving 0 13 0 11 5 148.4 ft2 0 0 0.3 0 _ 17 W Garage Frame - Wood Laundry 11 9 9 4 84.0 ft2 0.23 0.3 0 _ 18 N Garage Frame - Wood Laundry 11 5 9 4 46.7 ft2 0.23 0.3 0 _ 19 W Garage Frame - Wood Dining 11 9 9 4 84.0 ft2 0.23 0.3 0 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 2 Metal Low-E Single Yes 0.65 0.3 Y 48.0 ft2 8 ft 0 in 1 ft 4 in None None 2 N 2 Vinyl Low-E Single Yes 0.66 0.25 Y 27.0 ft2 8 ft 0 in 1 ft 4 in None None 3 W 3 Vinyl Low-E Single Yes 0.65 0.25 Y 27.0 ft2 14 ft 0 in 1 ft 4 in None None 4 N 4 Vinyl Low-E Single Yes 0.66 0.25 Y 36.0 ft2 2 ft 0 in 1 ft 4 in None None 5 E 12 Vinyl Low-E Single Yes 0.65 0.25 Y 20.0 ft2 2 ft 0 in 1 ft 4 in None None 6 S 13 Vinyl Low-E Single Yes 0.65 0.25 Y 50.0 ft2 2 ft 0 in 1 ft 4 in None None 7 W 14 Vinyl Low-E Single Yes 0.65 0.25 Y 72.0 ft2 2 ft 0 in 1 ft 4 in None None 8 S 15 Vinyl Low-E Single Yes 0.65 0.3 Y 96.0 ft2 12 ft 0 in 1 ft 4 in None None 9 W 16 Vinyl Low-E Single Yes 0.65 0.3 Y 72.0 ft2 14 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 330 ft2 330 ft2 23 ft 9.4 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000326 1470.3 80.66 151.44 .0997 5 4/9/2021 9:47 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 34.2 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / -- Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Living 6 80 ft2 AHU 10 ft2 Prop. Leak Free AHU — cfm 51.5 cfm 0.03 0.50 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb [[ ]] Mar HeatinJan Feb [X] Mar [ ] Apr I [ ] Apr May Jun Jul riAugX] May Jun Jul Au[ i Se ] Sep [ ] Oct [ ] Oct Nov WNov Dec Dec Ventin Jan Feb [[�X�) Mar [x] Apr May Jun Jul Aug I ] Se [x] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibslsq.ft. 0 ft2 Oft 0.3 Laundry Default(8 Ibslsq.ft, ft2 ft 0.3 Dining Default(8 lbs/sq.ft, ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibslsq.ft. ft2 ft 0.3 M Bath Default(8 Ibs/sq.ft. ft2 It 0.3 Toilet 4/9/2021 9:47 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft' ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8 lbslsq.ft. ft' ft 0.3 Hall Default(8 Ibs/s .ft. ft' ft 0.3 Living 4/9/2021 9:47 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 - - wrightsoftg Project Summary Date: Enure House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466.6799 Email: quickcalcs@aol.com Project I• • For: James Wright 6400 Koblegaurd Road, Fort Pierce, FL 34951 Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 26609 Btuh Structure 22945 Btuh Ducts 3713 Btuh Ducts 2530 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30323 Btuh Use manufacturer's data n Rate/swing multiplier Equipment load 0.95 Infiltration sensible 24201 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4057 Btuh Ducts 1972 Btuh Central vent (0 cfm) 0 Btuh Area Heatingg Coolingg (none) (ft5 1718 1718 Equipment latent load 6029 Btuh Volume (fe) 17643 17643 Air changes/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 30230 Btuh Equiv. AVF (cfm) 112 59 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond CA16NA03600GOCO AHRI ref Coil FX4DNF037L AHRI ref 20$463054 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 8.8 kW Sensible cooling 23940 Btuh Heating output 29974 Btuh Latent cooling 10260 Btuh Temperature rise 24 OF Total cooling 34200 Btuh Actual air flow 1140 cfm Actual air flow 1140 cfm Air flow factor 0,038 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigttitsoit- 2020-Nov-11 10:35:54 A:—:. ---.-.<--.--. Rght,sulteeUniverml201919.0.21 RSU08101 Pagel r r-C&-TocumentsUrightsoft HVAC\Wdght Residenoe.rup Cato = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL M Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox 0 1140 1140 0 0 0 0 Ox 0 VIFx wrightsoft- 2020-Nov-11 10:35:65 ^ti �. .•.. ---q R1ghtSuita®Universa12019 19.021 RSU08101 Paget C ...IDoc umentslWrightsoft HVAC%Wdght Residence.rup Calc - MJ8 Front Door faces: N - wrightsoft° Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com 1 2 Room name Exposed wall Entire House 171.0 ft Laundry 3.0 ft 3 Room height 10.3 ft 9.4 ft heaUcool 4 5 Room dimensions Room area 1718.0 fN 1.0 x 60.0 ft 60.0 fN Ty Construction number U-value (Btuhlft2` Or I Hl M (Bluhlft2) I Area (ft2) or perimeter (ft) I Load (Btuh) I Area (ft2) or perimeter (ft) I Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 V1 13A-7.5ocs 10A-m 1A-r1ov 0.095 1.670 0.900 n h n 2.66 46.76 25.20 1.26 25.31 19.79 352, 48 36 241 0 0 640 2244 907 304 1215 712 0 0 0 0 0 0 0 0 0 D 0 0 11 IA-rlov 13A-7.5ocs 0.900 0.095 n a 26.20 2.66 19.79 1.26 27 545 0 525 680 1397 534 664 0 0 0 0 0 0 0 0 V)/ ' 1A-r1ov 13A-7.5ocs 1A-rlov 0.900 0.095 0.900 a s s 25.20 2.66 2520 40.70 1.26 19.79 20 403 50 3 257 100 504 683 1260 814 324 989, 0 28 0 0 28, 0 0 75 0 0 36 0 C 1A-rtovd 13A-7.5ocs o.900 0.095 s w 25.20 2.66 19.79 1.26 96' 422 192 251 2419 668 1900 317 0 0 0 0 0 0 0 0 VVV���JJJ 1A-rlov 0.900 w 25.20 19.79 27 54 680 534 0 0 0 0 1A-r1ovd 0.900 w 25.20 41.31 72 6 1814 2975 0 0 0 0 1A-rtovd 0,900 w 25.20 19.79 72 144 1814 1425 0 0 0 0 C 16XI9.0ad 0.408 1.59 1.37 1718 1718 2724 2351 60 60 95 82 F 22A-tpl 0.989 27.69 0.00 1718 171 4735 0 60 3 83 0 61 c) AED excursion 2577 .9 Envelope loss/gain 23171 17635 2531 108 12 a) Infiltration 3438 969 56 16 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 8 1840 0 0 Appllanoes/other 2500 500 Subtotal (lines 6 to 13) 28609 22945 310 624 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 26609 22945 310 624 15 Duct loads 14% 11% 3713 2530 14%1 11% 43 69 Total room load 30323 25474 353 893 Air required (cfm) 1140 11401 13 31 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Ad- wrAfj"* daft- 2020-Nov-11 10:35:64 ^- - RlghtSuite®Unlvenal201919.021 RSU08101 Pagel ...TocumentslWrightsoft HVAQWright Resldence.rup Calc = MJ8 Front Door faces: N wrightsoft• Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466.6799 Emall: quickcsics@aol.com 1 Room name Dining [Kitchen 2 Exposed wall 16.0 It 10.0 ft 3 Room height 11.4 ft heaticool 11.4 ft heat/cool 4 5 Room dimensions Room area 1.0 x 198.0 ft 198.0 f12 1.0 x 276.0 ft 276.0 fP Ty Construction number U-value (Btuh/ft2= Or HTM (Btuhlft2) Area (ft2) or perimeter (ft) Load I (Btuh) Area M I or perimeter (ft) Load I (Btuh) Heat Cool Gross N/PIS Heat Cool Gross NIP/S Heat Cool 6 13A-7.6ocs 0.095 n 2.66 1.26 182 107 me 136 0 0 0 0 10A-m 1.670 n 46.76 25.31 48 0 2244 1215 0 0 0 0 V 1A-r1ov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 11 1A-r1ov 0.900 0.095 n a 25.20 2.68 _ 19.79 1.26 27 0 0 0 680 0 534 0 0 0 0 0 0 0 0 0 %13A-7.6ocs 1A-r1ov 13A-7.6ocs 1A-r1ov 0.900 0.095 0.900 a s s 25.20 2.e6. 25.20 40.70 1.26 19.79, 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-rlovd 0.900 s. 25.20 ,. 19.79 .01 0 0 0 0 0 0 0 VVV���lll 13A-7.5ocs 0.095 w 2.66 1.26 0 0 0 0 114 87 231 110 1A-r1ov 0.900 w 25.20 19.79 0 0 0 0 27 27 680 534 1A-r1ovd 0.900 w 25.20 41.31 0 0 0 0 0 0 0 0 1A-r1ovd 0.900 w 25.20 19.79 0 0 0 0 0 0 0 0 C 16XI9.Oad 0.406 - 1.59 1.37 198 198 '314 271 276 276 438 - 378 F 22A-tpl 0.089 27.69 0.00 198 16 443 0. 276 10 277 0 6 c) AED excursion 586 Envelope loss/galn 3968 2119 1 16261 1608 12 a) Infiltration 364 103 228 64 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 230 1 230 2 460 Appllanoestother 0 2000 Subtotal (lines 6 to 13) 4332 2452 1854 4132 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 8 8 7 14 Subtotal 4341 2460 1862 4139 15 Duct loads 14% 11% 606 271 14°/u 11% 260 456 Total room load 4947 2732 2122 4595 Air required (cfm) 186 122 80 206 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed, wr Sft1;=C'1 t- 2020-Nov-11 10:35:54 ^ -- -� RightSulte®Universal 2019 19.021 RSLI08101 Paget tDocuments%Wdghtsoft WAC\Wright Residence.rup Cale - MA Front Doorfaces: N - wrightsoft° Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 77246M799 Email: quickcalcs@aol.com 1 Room name AHU Bedroom 2 Exposed wall 0 It 36.0 ft 3 Room height 9.4 ft hea/cool 9.4 ft heat/cool 4 5 Room dimensions Room area 3.0 x 4.0 it 12.0 ft' 1.0 x 231.0 ft 231 n ft' Ty Construction U-value Or I HTM I Area (ft� I Load I Area (ft') Load number (Btuh/Ft'= (Btuh/ft2) or perimeter (ft) (Bluh) or perimeter (ft) I (Stuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 8 13A-7.5ocs, 0:095 n 1.31 0 0 0 0 160 120 320 150 10A-m 1.070 'n 6.76 48.78 25.31 0 0 0 0 0 0 0 0 � 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 36 0 907 712 11 1A-rtov 13A-7.5ocs 0:900 0.095 n a 25.20 2.66 19.79 1.26 0 0 0 0 0 0 0 0 0 141 0 141 0 375 0 178 At 1A-r1ov 13A-7.5ocs 1A-r1ov 0.900 0.095 0.900 e. s s 25.20 2.66 25.20 40.70 1.26 19.79 0 0 0 0 0 0 0 0 0 0 0 0 0 9 0 0 9 0 0 25 0 0 12 0 1A-r1ovd 0.900 s 25.20 19.79 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.66 1.26 0 0 0 0 28 28 75 36 1A-r1ov 1A-rlovd 0.900 0.900 w w 25.20 25.20 19.79 41.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-rlovd 0.900 w_ 25.20 19.79 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 1.59 1.37 12 12 19 16 231 231 366 316 F 22A-tpl _ 0.989 27.69 0.00 12 0 0 0 231 36 997 0 8 c) AF,D excursion 0 27 Envelope loss/gain 191 16 1 13075 1384 12 a) Infiltration 0 0 676 191 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 8 to 13) 19 16 3751 1804 Less external load 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal -19 0 -16 0 10 3760 a 1812 15 Duct loads 14% 11% 0 0 14% 11% 525 200 Total room load Air required (cfm) 0 01 0 01 42115 16l 2012 90 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrtgi�ftasaf r -^ ---�- a- WghtSuite®Unlwrsa12019 19.022020-Nov-11 10:35:641 RSU06101 Page \Documents\Wdghtsoft WAC\Wright Residence.rup Calc = MJ8 Front Door faces: N -- wrightsoft° Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Plerce, FL 34946 Phone: 772466-6799 Emali: quickcalcs@aol.com 1 Room name Bath 2 M Bath 2 3 Exposed wall Room height 0 ft 9.4 ft heat/cool 12.0 ft 9.4 ft heat/000l 4 5 Room dimensions Room area 6.0 x 12.0 ft 72.0 f? 10.0 x 12.0 It 120.0 ft2 Ty I Construction number U-value (Btuh/ft'° Or HTM (Btuh/ft2 Area (M I or perimeter (ft) Load I (Btuh) AreaLoad or perimeter (ft) I (Btuh) Heat Cool Gross I N/P/S Heat Cool Gross I N/P/S Heat Cool 6 11 13A-7.bocs' 10A-m 1A-r1ov 1A-r1ov 13A-7.5ocs 0.095 1,610 0.900 0.900 0.095 n n n n a 2.66 46.76. 25.20 .25.20 2.66 1.26 25.31 19.79 19.79 1.26 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o. 0 0 0 0 0 0 0. 113 0 0 0 0 113 0 0 0 -0 300 0 0 0 0 143 11 1A-r1ov 13A-7.5ocs 1A-rlov 1A-r1ovd 0.900 0.095 0.900 0.900 0,095 a s s s w 25.20 2.66 25.20 25.20 2.66 40.70 1,26 19.79, .,_ 19.79 1.26 0 0 0 0, 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-r1ov 1A-r1ovd 1A-r1ovd 0.900 0,900 0.900 w w w 25.20 25.20 25.20 19.79 41.31 19.79 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TE�13A-7.50cs C F 16X19.0ad 22A-tpl 0.408 0.989 - 1.59 27.69 1.37 0.00 72 72 72 0 114 0 99. 0 120 120 120. 12 100 332 164 0 61 c) AED excursion -1 S Envelope loss/gain 114 97 1 8231 301 12 a) Infiltration 0 0 225 64 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 114 97 1046 365 Less external load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Duct loads 14% 11°/a 0 6 120 17 0 5 102 11 14% 11% 0 8 1056 147 0 7 372 41 Total room load Alr required (cfm) 137 5 113 5 1 1 1203 45 413 18 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. we'19ti*=Atftt- 2020-Nov-1 1 10:35:64 - - - RlghtSuite®Univerml2019 19.0.21 RSU08101 Page ..,1DocumentsUrightsoft WAC1Wdght Residence.rup Cale = MJ8 Front Door faces: N - wrightsoft• Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc, By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Toilet WIC 2 3 Exposed wall Room height 6.0 ft 9.4 ft heat/cool 10.0 ft 9.4 ft hest/cool 4 5 Room dimensions Room area 7.0 x 4.0 ft 28.0 ft' 8.0 x 10.0 ft 80.0 ft' Ty Construction number U-value (Btuh4t; Or HTM (Btuh/ftj Area (ft') I or perimeter (ft) Load I (Btuh) Area or perimeter (ft) Load I (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-7.5ocs 10A-m 1A-rlov 0.095 1.670 0.900 n n n 2.66 46.76 25.20 1.26 25.31 19.79 9 0 0 9 0 0 25 0 0 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 1A-r1ov 13A-7.50cs 0.900 0.095 n a 25.20 2.66 19.79 1.26 0 38 0 38 0 100 0. 48 0 94 0 94 0 250 0 119 L--O 1Arr1ov 13A-7.5ocs 10-r1ov 0.900 0.095 0.900 a s s 25.20 2.56 25.20. 40.70 1.26 19.79 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Vh13A-7.50cs 1A-r1ovd 0,900. 0.095 s w 25.20 2.66 19.79 1.26 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-r1ov 1A-r1ovd 1A-r1ovd 0,900 0.900 0.900 w w w 25.20 25.20 25.20 19.79 41.31 19.79 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c F 16X19-0ad 22A-tpl 0.408 0.989 - - 1.59 27.69 _ 1.37 0.00 28 28 28 5 44 138 38 0 80 80 80 10 _ 127 277 109 0 6 c) AED excursion -2 -4 Envelope loss/galn 308 gel 1 1 6541 224 12 a) Infiltration 94 26 188 53 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants ® 230 0 0 0 0 Appliences/other 0 0 Subtotal (lines 6 to 13) 402 122 842 277 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 8 410 0 7 129 0 2 844 0 2 279 15 Duct loads 14% 11% 57 14 14% 11% 118 31 Total room load Air required (cfm) 1 467 18 143 6 1 1 961 36 309 14 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .` wrajo ` 2020-Nov-1 1 10:35:54 - --- �-� WghtSuite®Unlvermi2019 19.0.21 RSU08101 Pages ...\Documents\Wdghtsoft WAC\Wright Residenos.rup Cale - MJ8 Front Door faces: N -- wrightsoft° Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466.6799 Email: quickcaics@aol.com 1 Room name Master Bedroom Hall 2 3 Exposed wall Room height 48.0 ft 9.4 ft heat/000l 0 ft 9.4 ft heat/cool 4 5 Room dimensions Room area 1.0 x 340.0 ft 340.0 ft' 7.0 x 4.0 ft 28.0 ft, Ty Construction number U-value (Btuh/f12° Or I HTM (Btuh/ft5 Area (ft2 or perimeter (ft) I Load (Btuh) I Area (ft) or perimeter (ft) I Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-7.5ocs 10A-m 0.095 1.670 n n 2,66 46.76 1.26 25.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-r1ov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 11 1A-r1ov 13A-7.5ocs 0.900 0.095 n a 25.20 2.66 19.79 1.26 0 160 0 140 0 372 0 177 0 0 0 0 0 0 0 0 1A-r1ov 13A-7.5ocs 1A-r1ov 0.900 0.095 0.900 a s s 25.20 2.66 25.20 40.70 1.26 19.79 20 160 50 1 110 50 504 292 1260 614 139 989 - 0 0 0 0 0 0 0 0 0 0 0 0 1A-rlovd 13A-7.5ocs 0.900 0.095 s w 25.20 2.66 19.79 1.28 _ 0, 132 0 60 0 159 0 75 0 0 0 0 0 0 0 0 ,A-r1ov 0,900 w 25,20 19.79 0 0 0 0 0 0 0 0 1A-r1ovd 1A-r1ovd 0,900 0.900 w w 25.20 25.20 41.31 19.79 72 0 3 0 1814 0 2975 0 0 0 0 0 0 0 0 0 C F 16X19.Oad 22A-tpl 0.408 0.989 - - 1,59 27.69 1.37 0.00 340 340 340 48 539 1329 465 0 28 28 28 0 44 0 38 0 6 c) AED excursion 686 1 Envelope loss/gain 6269 6320 44 38 12 a) Infiltration 901 254 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appllanoes/other 0 0 Subtotal (lines 6 to 13) 7170 7035 44 38 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 12 7183 0 10 1045 0 -44 0 0 -38 0 15 Duct loads 14% 11% 1002 777 14% 11% 0 0 Total room load 8185 7822 0 0 Al, required (cfm) 308 3501 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. we tlgi�tntt r ' 2020-Nov-11 10:35:64 -- ---- - RlghtSuiteOUniversal 201919.021RSU08101 Page 1Documents\Wdghtsoft WAC1Wdght Residence.rup Calc = MJ8 Front Door faces: N - wrightsoft° Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-486-6799 Email: quickcaics@aol.com 1 Room name Living 2 Exposed wall 31.0 ft 3 Room height 11.4 ft heat/cool 4 5 Room dimensions Room area 21.0 x 13.0 ft 273.0 ft' Ty Construction U-value Or HTM Area W) Load I Area I Load number I (Btuh$t'° (Btuhift2 I or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6%1� 13A-7.5ocs 0.095 n 2.66 1.28 0_ 0 0 0 1OA-m 1.670 n 46.78 25.31 0. 0 0 0 to-rlov 0.900 n 25.20. 19.79 0 0 0 0 11 1A-rlov 13A-7.6ocs 0.900 0:095 n a 25.20 2.66 19.79 1.26 0 0 0 0 0 0 0 0 �-G 1A-r1ov 0.900 a 25.20 40.70 0 0 0 0 13A-7.5ocs 0.095 s 2.66 1.26 205 109 290 138 IA-rlov 0.900 s 25.20 19.79 0 0 0 0 IA-r1ovd 0.900 s 25.20 19.79 96 96 2419 1900 13A-7.50cs 0.095 w 2.66 ,., 1.26 148 76 203 96 ,A-rlov 0.900 w 25.20 19.79 0 0 0 0 1A-rlovd 0.900 w 25.20 41.31 0 0 0 0 1A-rlovd 0.900 w 25.20 19.79 72 72 1814 1425 C 16X19-Oad 0.408 1.59 1.37 273 273 .433 374 F 22A-tpl 0.989 - 27.69 0.00 273 31 858 0 8 c) AED excursion 1391 Envelope loss/galn 6018 5323 12 a) Infiltration 706 199 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 2 460 Applianoes/other 0 Subtotal (lines 6 to 13) 6724 5982 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 6724 5982 15 Duct loads 14% 11% 938 660 Total room load 7662 6642 Air required (cfm) 288 297 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. L wr1g1w1tratPt 2020-Nov-11 10:35:54 �c� •-�•-• -•-••-4•--•-^ WghtSuite®Unlvers�12Q79 19.0.21 RSU08101 Pagel \DocumentslWdghtsoft WAC\Wdght Residence.rup Calc = MJ8 Front Door faces: N Duct System Summary Job: 1iVrlgfltS4ft Date: Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcaicsoaol.com Project• • For: James Wright 6400 Koblegaurd Road, Fort Pierce, FL 34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.277 in/100ft 1140 cfm 181 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.277 in/100ft 1140 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath 2 c 137 5 5 0.391 4.0 Ox 0 VIFx 12.8 115.0 st2 Bedroom 2 h 4285 161 90 0.389 8.0 Ox 0 VIFx 13.5 115.0 st2 Dining h 4947 186 122 0.391 8.0 Ox 0 VIFx 12.8 115.0 st1 Kitchen c 2298 40 103 0.359 7.0 Ox 0 VIFx 24.3 115.0 SO Kitchen -A c 2298 40 103 0.380 7.0 Ox 0 VIFx 16.5 115.0 st1 Laundry c 693 13 31 0.369 5.0 Ox 0 VIFx 20.6 115.0 st1 Living c 3321 144 149 0.346 7.0 Ox 0 VIFx 29.7 115.0 st4 Living -A c 3321 144 149 0.348 7.0 Ox 0 VIFx 28.5 115.0 st4 M Bath h 1203 45 18 0.367 5.0 Ox 0 VIFx 21.3 116.0 st3 Master Bedroom c 3911 154 175 0.277 8.0 Ox 0 VIFx 45.7 135.0 sty Master Bedroom -A C 3911 154 175 0.278 8.0 Ox0 VIFx 45.1 135.0 sty Toilet h 467 18 6 0.363 4.0 Ox 0 VIFx 22.9 115.0 st3 Nnc h 961 36 14 0.350 4.0 Ox 0 VIFx 27.7 115.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk SO Peak AVF 308 350 0.277 642 10.0 0 x 0 VinlFix st3 st3 Peak AVF 407 389 0.277 518 12.0 0 x 0 VinlFlx st2 Peak AVF 166 95 0.389 476 8.0 0 x 0 VinlFlx st4 Peak AVF 288 297 0.346 545 10.0 0 x 0 VinlFlx st1 Peak AVF 279 359 0.359 457 12.0 0 x 0 VinlFlx {� wright1`sof[, 2020-Nov-1 1 10:35:55 „ .��• ,....... �,.e RlghtSulte®Universal 2019 19.021 RSU08101 Page 1 j4 i� ..,1DocumentslWrightsoft WACUright Residenoe.rup Celc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 0x 0 1140 1140 0 0 0 0 Ox 0 VIFx •. ' wrightsoft" wr� .,. .,.�,,>.,.... RlghtSulte®Universal 2019 19.0.21 RSU08101 fri�....1Documents\Wdghtsoft HVAC%Wright Residence.rup Cale - MJ8 Front Door faces: N 2020-Nov-11 10:35:55 Page 2 FORM R405-2020 .ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows** Description a. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.65 SHGC: SHGC=0.30 c. U-Factor: N/A SHGC: d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): NIA 6400 Koblegaurd Road, Fort Pierce, FL, 34951 New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Polystyrene Bead A%R=0.0 1724.30 ft2 b. Frame - Wood, Adjacent R=11.0 214.67 ft2 1 c. N/A R= ft2 2 d. N/A R= ft2 No 11. Ceiling Type and insulation level Insulation Area a. Roof Deck (Unvented) R=20.0 1718.00 ft2 1718 b. N/A R= ft2 Area c. NIA R= ft2 232.00 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Living, Ret: AHU, AH: AHU 6 80 216.00 ft2 13. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 34.2 SEER:16.00 ft2 7,799 ft, 0.274 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1718.00 ft2 b. NIA R= ft2 c. NIA R= ft2 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: kBtu/hr Efficiency 27.0 COP:1.00 Cap: 50 gallons EF: 0.95 CF. Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/9/2021 9:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Wright Residence Builder Name: Street; 6400 Koblegaurd Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL, 34951 Permit Number: Y Owner: James Wright Jurisdiction: St. Lucie County w= Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including Insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on Installation readily conforms to available space shall Showerltub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection Of og walls shall be in accordance wnt the provisions of ICC-400. 4/9/2021 9,48 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the. home. 1. New construction or eAtting 2. Single family or multiple family 3: Number of units, if multiple family 4. "Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftJ 7. Windows*" Description a. U-Factor. Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor. Sgf, U=0.65 SHGC: SHGC=0.30 c. U-Factor. N/A SHGC:. d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 6400 Koblegaurd Road, Fort Pierce, FL, 34951 New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Polystyrene Bead Ag¢t=0.0 1724.30 ft2 - b. Frame - Wood, Adjacent R=11.0 214.67 ft2 1 c. N/A R= ft2 2 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area No , a. Roof DecW (Unvented) R=20.0 1718.00 ft2 1718 b. N/A R= ft2 Area c. N/A R= ft' 232.00 ft2 12. Ducts, location & insulation level F2 ft' a. Sup: Living, Ret: AHU, AH: AHU 6 86 216.00 ft2 13. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 34.2 SEER:16.00 ft2 7.799 ft. 0.274 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation . R=0.0 1718.00 ft2 b. NIA R= ftZ c. NIA R= ft2 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida. Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Codecompliant features. Builder Signature: Date: Address of. New Home: City/FL Zip: kBtulhr Efficiency 27.0 COP:1.00 Cap: 50 gallons EF: 0.95 CF, Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient' mortgage (EEM) incentives if you obtain a Florida Energy•Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the. Florida Building Code,- Energy Conservation, if'not DEFAULT. 4/9/2021 9:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 2020 - AIR -BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION .COMPONENT CRITERIA Project Name: Wright Residence Builder Name: Street: 6400 Koblegaurd Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL , 34951 Permit Number: Y U Owner. James Wright Jurisdiction: St. Lucie County W x Design Location: FL, Fort -Pierce . r, COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be Installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air.barder. not be used as a sealing material. Breaks, or joints in the air border shall be sealed, Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in- any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed._ shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities*within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a'thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. - Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air border. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shail'include the air barrier. Rim joists shall be insulated. Floors The air border shall be installed at any exposed, edge of Floor framing cavity Insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all' perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wells. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on. Installation readily conforms to the available cavity spaces. Garage. separation . Air sealing shall be provided between the garage and coriditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on Installation readily conforms to available space shall AYILund hphlnri piping and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electdcallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots WAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids hatween fire sprinkler cover Metes god walls or rgliongs. a. In addition; inspection or Ing walls shall be in accordance with the provisions of ICU-400. 4/9/2021 9,48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1