HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Wright Residence
Builder Name:
Street: 6400 Koblegaurd Road
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL, 34961
Permit Number:
Owner. James Wright
Jurisdiction: St. Lucie County
Design Location: ' FL, Fort Pierce
County: St. Lucie (Florida Climate zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type41938.9 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Polystyrene Bead AgGR=0.0 1724.30 fta
b. Frame - Wood, Adjacent
R=11.0 214.67 fta
3. Number of units, if multiple family 1
c. N/A
R= fta
4. Number of Bedrooms 2
d. N/A
R= fta
5. Is this a worst case? No
11. Ceiling Types (1718.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 1718.00 ft a
6. Conditioned floor area above grade (fta) 1718
b. N/A
R= fta
Conditioned floor area below grade (fta) 0
c. N/A
R= fta
7. Windows(448.0 sqft.) Description Area
12. Ducts
a. Sup: Living, Ret: AHU, AH: AHU
R fta
6 80
a. U-Factor: Sgl, U=0.65 232.00 fta
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65 216.00 fta
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
34.2 SEER:16.00
c. U-Factor. N/A fta
SHGC:
Weighted Average Overhang Depth: 7.799 ft.
14. Heating systems
kBtu/hr EfficiencyArea
Area Weighted Average SHGC: 0.274
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor(AVG) N/A fta
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1718.0 sgft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1718.00 fta
b. Conservation features
b. N/A R= fta
None
c. N/A R= fta
16. Credits
CF, Pstat
Total Proposed Modified Loads: 58.30
Glass/Floor Area: 0.261
PASS
Total Baseline Loads: 58.36
1 hereby certify that the plans and specifications covered by
Review of the plans and
F'tHE STAp
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
y `,.=��..� rs+
with the Florida Energy Code.
%Ihrr''+• "-•'',i �O
Bxx'
PREPARE�D4-9-L
DATE: b 1
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
COD yyg'i��
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested In accordance with ANSI/RESNET/ICC 380, Is not greater than 0,030 Qn for whole house.
2101'oX_3s
4/9/2021 9:47 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Comp '`an Eig anVpm §bage 1 of 6
FORM-R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Wright Residence
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1718
Lot #
Owner Name: James Wright
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
6400 Koblegaurd Road
Permit Office: St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: St. Lucie County
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
Family Type: Detached
FL, 34951
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location TMY
Site 97.5 %
2.6 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1718 17643.2
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 Laundry 60
564 No
0
1
Yes
Yes
Yes
2 Dining 198
2257.2 No
0
1
Yes
Yes
Yes
3 Kitchen 276
3146.4 Yes
1
1
Yes
Yes
Yes
4 AHU 12
112.8 No
0
1
No
Yes
Yes
5 Bedroom 2 231
2171.4 No
0
1
1
Yes
Yes
Yes
6 Bath 2 72
676.8 No
0
1
No
Yes
Yes
7 M Bath 120
1128 No
0
1
Yes
Yes
Yes
8 Toilet 28
263.2 No
0
1
Yes
Yes
Yes
9 WIC 80
752 No
0
1
Yes
Yes
Yes
10 Master Bedroom 340
3196 No
0
1
1
Yes
Yes
Yes
11 Hall 28
263.2 No
0
1
No
Yes
Yes
12 Living 273
3112.2 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Laundry 3 ft
60 ft2
1 0
0
2 Slab -On -Grade Edge Insulatio
Dining 16 ft
198 ft2
1 0
0
3 Slab -On -Grade Edge Insulatio
Kitchen loft
276 ft2
1 0
0
4 Slab -On -Grade Edge Insulatio
AHU 1 8
12 ft2
1 0
0
5 Slab -On -Grade Edge Insulatio
Bedroom 2 $6 ft
231 ft2
___
1 0
0
4/9/2021 9:47 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
F.ORM, R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
6 Stab -On -Grade Edge Insulatio
Bath 2 1 ft
72 ft2
1 0
0
7 Slab -On -Grade Edge Insulatio
M Bath 12 ft
120 ft2
1 0
0
8 Slab -On -Grade Edge Insulatio
Toilet 5 ft
28 W
____
1 0
0
9 Slab -On -Grade Edge Insulatio
WIC loft
80 ft2
_W
1 0
0
10SIab-On-Grade Edge Insulatio
Master Bedroom 48 ft
340 ft2
___
1 0
0
11SIab-On-Grade Edge Insulatio
Hall 1 ft
28 ft2
-__-
1 0
0
12SIab-On-Grade Edge Insulatio
Living 31 ft
273 ft2
1 0
0
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials
Area
Area
Color
Barr
Absor.
Tested
Tested Insui.
(deg)
1 Hip
Metal 1921 ft2
0 ft2
Light
N
0.6
No 0.9
No 20
26.57
ATTIC
V # Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Unvented
0
1718 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Unvented)
Laundry
0
Blown
60 ft2
0.1
Wood
2 Under Attic (Unvented)
Dining
0
Blown
198 ft2
0.1
Wood
3 Under Attic (Unvented)
Kitchen
0
Blown
276 ft2
0.1
Wood
4 Under Attic (Unvented)
AHU
0
Blown
12 ft2
0.1
Wood
5 Under Attic (Unvented)
Bedroom 2
0
Blown
231 ft2
0.1
Wood
6 Under Attic (Unvented)
Bath 2
0
Blown
72 ft2
0.1
Wood
7 Under Attic (Unvented)
M Bath
0
Blown
120 ft2
0.1
Wood
8 Under Attic (Unvented)
Toilet
0
Blown
28 ft2
0.1
Wood
9 Under Attic (Unvented)
WIC
0
Blown
80 ft2
0.1
Wood
10 Under Attic (Unvented)
Master Bedroom
0
Blown
340 ft2
0.1
Wood
11 Under Attic (Unvented)
Hall
0
Blown
28 ft2
0.1
Wood
12 Under Attic (Unvented)
Living
0
Blown
273 ft2
0.1
Wood
WALLS
Adjacent
a amt To Wall Type
Space Cavity Width
Height
Sheathing Framing Solar
Below
1 S Exterior Concrete Block - Polystyrelmundry
0 3
0 9
5
28.3 ft2
0
0 0.3
0
_ 2 N Exterior Concrete Block - PolystyrerDining
0 16
0 11
5
182.7 ft2
0
0 0,3
0
_ 3 W Exterior Concrete Block - PolystyreKitchen
0 10
0 11
5
114.2 ft2
0
0 0.3
0
4 N Exterior Concrete Block - Polysty8rdroom 2
0 17
0 9
5
160.1 ft2
0
0 0,3
0
4/9/2021 9:47 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
nrnf
Adjacent Sin
ToWall Typepace
Cavity
Width
Height
Et
Sheathing Framing
Walup
Solar
Below
'mde%
_ 5
E
Exterior
Concrete Block - Polysty&droom 2
0
15
0
9
5
141.3 ft2
0
0
0.3
0
_ 6
S
Exterior
Concrete Block - Polystyftedroom 2
0
1
0
9
5
9.4 ft2
0
0
0,3
0
_ 7
W
Exterior
Concrete Block - Polystyrtdroom 2
0
3
0
9
5
28.3 ft2
0
0
0.3
0
8
E
Exterior
Concrete Block - PolystyreM Bath
0
12
0
9
5
113.0 W
0
0
0.3
0
_ 9
N
Exterior
Concrete Block - PolystyrenToilet
0
1
0
9
5
9.4 ft2
0
0
0.3
0
10
E
Exterior
Concrete Block - PolystyrenToilet
0
4
0
9
5
37.7 ft2
0
0
013
0
11
E
Exterior
Concrete Block - PolystyrenWIC
0
10
0
9
5
94.2 ft2
0
0
0,3
0
_ 12
E
Exterior
Concrete Block - Polystpeater Bedro
0
17
0
9
5
160.1 ft2
0
0
0.3
0
_ 13
S
Exterior
Concrete Block - Polyst1dester Bedro
0
17
0
9
5
160.1 ftz
0
0
0.3
0
14
W
Exterior
Concrete Block - Polystpeeter Bedro
0
14
0
9
5
131.8 ft2
0
0
0.3
0
_ 15
S
Exterior
Concrete Block - PolystyrerLiving
0
18
0
11
5
205.5 ft2
0
0
0,3
0
16
W
Exterior
Concrete Block - Polystyrert-iving
0
13
0
11
5
148.4 ft2
0
0
0.3
0
_ 17
W
Garage
Frame - Wood Laundry
11
9
9
4
84.0 ft2
0.23
0.3
0
_ 18
N
Garage
Frame - Wood Laundry
11
5
9
4
46.7 ft2
0.23
0.3
0
_ 19
W
Garage
Frame - Wood Dining
11
9
9
4
84.0 ft2
0.23
0.3
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 2
Metal Low-E Single Yes
0.65
0.3
Y
48.0 ft2
8 ft 0 in
1 ft 4 in
None
None
2
N 2
Vinyl Low-E Single Yes
0.66
0.25
Y
27.0 ft2
8 ft 0 in
1 ft 4 in
None
None
3
W 3
Vinyl Low-E Single Yes
0.65
0.25
Y
27.0 ft2
14 ft 0 in
1 ft 4 in
None
None
4
N 4
Vinyl Low-E Single Yes
0.66
0.25
Y
36.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
E 12
Vinyl Low-E Single Yes
0.65
0.25
Y
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
S 13
Vinyl Low-E Single Yes
0.65
0.25
Y
50.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
W 14
Vinyl Low-E Single Yes
0.65
0.25
Y
72.0 ft2
2 ft 0 in
1 ft 4 in
None
None
8
S 15
Vinyl Low-E Single Yes
0.65
0.3
Y
96.0 ft2
12 ft 0 in
1 ft 4 in
None
None
9
W 16
Vinyl Low-E Single Yes
0.65
0.3
Y
72.0 ft2
14 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
330 ft2 330 ft2
23 ft
9.4 ft
11
INFILTRATION
#
Scope
Method SLA CFM 50
ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000326 1470.3
80.66
151.44
.0997
5
4/9/2021 9:47 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Strip Heat/
None
COPA 27 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16 34.2 kBtu/hr cfm
0.8
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/ -- Supply —
— Return — Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type Handler
TOT
OUT QN
RLF
Heat Cool
1 Living 6 80 ft2
AHU
10 ft2 Prop. Leak Free AHU
— cfm
51.5 cfm 0.03
0.50
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb [[ ]] Mar
HeatinJan Feb [X] Mar
[ ] Apr I
[ ] Apr
May Jun Jul riAugX]
May Jun Jul Au[
i
Se
] Sep
[ ] Oct
[ ] Oct
Nov
WNov
Dec
Dec
Ventin Jan Feb [[�X�) Mar
[x] Apr
May Jun Jul Aug
I ] Se
[x] Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6 7
8
9
10
11
12
Cooling (WD) AM 78
78 78
78 78 78 78
78
80
80
80
80
PM 80
80 78
78 78 78 78
78
78
78
78
78
Cooling (WEH) AM 78
78 78
78 78 78 78
78
78
78
78
78
PM 78
78 78
78 78 78 78
78
78
78
78
78
Heating (WD) AM 66
66 66
66 66 68 68
68
68
68
68
68
PM 68
68 68
68 68 68 68
68
68
68
66
66
Heating (WEH) AM 66
66 66
66 66 68 68
68
68
68
68
68
PM 68
68 68
68 68 68 68
68
68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibslsq.ft.
0 ft2
Oft 0.3
Laundry
Default(8 Ibslsq.ft,
ft2
ft 0.3
Dining
Default(8 lbs/sq.ft,
ft2
ft 0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft 0.3
AHU
Default(8 Ibs/sq.ft.
ft2
ft 0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft 0.3
Bath 2
Default(8 Ibslsq.ft.
ft2
ft 0.3
M Bath
Default(8 Ibs/sq.ft.
ft2
It 0.3
Toilet
4/9/2021 9:47 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. ft' ft 0.3 WIC
Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom
Default(8 lbslsq.ft. ft' ft 0.3 Hall
Default(8 Ibs/s .ft. ft' ft 0.3 Living
4/9/2021 9:47 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6
- - wrightsoftg Project Summary Date:
Enure House By:
Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466.6799 Email: quickcalcs@aol.com
Project I• •
For: James Wright
6400 Koblegaurd Road, Fort Pierce, FL 34951
Notes:
Design
Information
Weather: Fort Pierce,
FL, US
Winter Design
Conditions
Summer Design Conditions
Outside db
42 °F
Outside db
90
OF
Inside db
70 OF
Inside db
75
OF
Design TD
28 OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
gr/lb
Heating Summary
Sensible Cooling Equipment
Load
Sizing
Structure
26609 Btuh
Structure
22945
Btuh
Ducts
3713 Btuh
Ducts
2530
Btuh
Central vent (0 cfm)
0 Btuh
Central vent (0 cfm)
0
Btuh
none
(none)
Humidification
0 Btuh
Blower
0
Btuh
Piping
0 Btuh
Equipment load
30323 Btuh
Use manufacturer's data
n
Rate/swing multiplier
Equipment load
0.95
Infiltration
sensible
24201
Btuh
Method
Simplified
Latent Cooling Equipment Load
Sizing
Construction quality
Average
Fireplaces
0
Structure
4057
Btuh
Ducts
1972
Btuh
Central vent (0 cfm)
0
Btuh
Area
Heatingg Coolingg
(none)
(ft5
1718 1718
Equipment latent load
6029
Btuh
Volume (fe)
17643 17643
Air changes/hour
0.38 0.20
Equipment Total Load (Sen+Lat)
30230
Btuh
Equiv. AVF (cfm)
112 59
Req. total capacity at 0.70 SHR
2.9
ton
Heating Equipment Summary
Cooling Equipment Summary
Make
Make Carrier
Trade
Trade CARRIER
Model
Cond CA16NA03600GOCO
AHRI ref
Coil FX4DNF037L
AHRI ref 20$463054
Efficiency
100 EFF
Efficiency 13.0 EER,
16 SEER
Heating input
8.8 kW
Sensible cooling
23940
Btuh
Heating output
29974 Btuh
Latent cooling
10260
Btuh
Temperature rise
24 OF
Total cooling
34200
Btuh
Actual air flow
1140 cfm
Actual air flow
1140
cfm
Air flow factor
0,038 cfm/Btuh
Air flow factor
0.045
cfm/Btuh
Static pressure
0.50 in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.81
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrigttitsoit- 2020-Nov-11 10:35:54
A:—:. ---.-.<--.--. Rght,sulteeUniverml201919.0.21 RSU08101 Pagel
r r-C&-TocumentsUrightsoft HVAC\Wdght Residenoe.rup Cato = MJ8 Front Door faces: N
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
M
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb2
Ox 0
1140
1140
0
0
0
0
Ox 0
VIFx
wrightsoft- 2020-Nov-11 10:35:65
^ti �. .•.. ---q R1ghtSuita®Universa12019 19.021 RSU08101 Paget
C ...IDoc umentslWrightsoft HVAC%Wdght Residence.rup Calc - MJ8 Front Door faces: N
- wrightsoft° Right-J® Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com
1
2
Room name
Exposed wall
Entire House
171.0 ft
Laundry
3.0 ft
3
Room height
10.3 ft
9.4 ft heaUcool
4
5
Room dimensions
Room area
1718.0 fN
1.0 x 60.0 ft
60.0 fN
Ty
Construction
number
U-value
(Btuhlft2`
Or
I Hl M
(Bluhlft2)
I Area (ft2)
or perimeter (ft)
I Load
(Btuh)
I Area (ft2)
or perimeter (ft)
I Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
NIP/S
Heat
Cool
6
V1
13A-7.5ocs
10A-m
1A-r1ov
0.095
1.670
0.900
n
h
n
2.66
46.76
25.20
1.26
25.31
19.79
352,
48
36
241
0
0
640
2244
907
304
1215
712
0
0
0
0
0
0
0
0
0
D
0
0
11
IA-rlov
13A-7.5ocs
0.900
0.095
n
a
26.20
2.66
19.79
1.26
27
545
0
525
680
1397
534
664
0
0
0
0
0
0
0
0
V)/
'
1A-r1ov
13A-7.5ocs
1A-rlov
0.900
0.095
0.900
a
s
s
25.20
2.66
2520
40.70
1.26
19.79
20
403
50
3
257
100
504
683
1260
814
324
989,
0
28
0
0
28,
0
0
75
0
0
36
0
C
1A-rtovd
13A-7.5ocs
o.900
0.095
s
w
25.20
2.66
19.79
1.26
96'
422
192
251
2419
668
1900
317
0
0
0
0
0
0
0
0
VVV���JJJ
1A-rlov
0.900
w
25.20
19.79
27
54
680
534
0
0
0
0
1A-r1ovd
0.900
w
25.20
41.31
72
6
1814
2975
0
0
0
0
1A-rtovd
0,900
w
25.20
19.79
72
144
1814
1425
0
0
0
0
C
16XI9.0ad
0.408
1.59
1.37
1718
1718
2724
2351
60
60
95
82
F
22A-tpl
0.989
27.69
0.00
1718
171
4735
0
60
3
83
0
61
c) AED excursion
2577
.9
Envelope loss/gain
23171
17635
2531
108
12
a) Infiltration
3438
969
56
16
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
8
1840
0
0
Appllanoes/other
2500
500
Subtotal (lines 6 to 13)
28609
22945
310
624
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
26609
22945
310
624
15
Duct loads
14%
11%
3713
2530
14%1
11%
43
69
Total room load
30323
25474
353
893
Air required (cfm)
1140
11401
13
31
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Ad- wrAfj"* daft- 2020-Nov-11 10:35:64
^- - RlghtSuite®Unlvenal201919.021 RSU08101 Pagel
...TocumentslWrightsoft HVAQWright Resldence.rup Calc = MJ8 Front Door faces: N
wrightsoft• Right-J® Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466.6799 Emall: quickcsics@aol.com
1
Room name
Dining
[Kitchen
2
Exposed wall
16.0 It
10.0 ft
3
Room height
11.4 ft heaticool
11.4 ft heat/cool
4
5
Room dimensions
Room area
1.0 x 198.0 ft
198.0 f12
1.0 x 276.0 ft
276.0 fP
Ty
Construction
number
U-value
(Btuh/ft2=
Or
HTM
(Btuhlft2)
Area (ft2)
or perimeter (ft)
Load
I (Btuh)
Area M
I or perimeter (ft)
Load
I (Btuh)
Heat
Cool
Gross
N/PIS
Heat
Cool
Gross
NIP/S
Heat
Cool
6
13A-7.6ocs
0.095
n
2.66
1.26
182
107
me
136
0
0
0
0
10A-m
1.670
n
46.76
25.31
48
0
2244
1215
0
0
0
0
V
1A-r1ov
0.900
n
25.20
19.79
0
0
0
0
0
0
0
0
11
1A-r1ov
0.900
0.095
n
a
25.20
2.68
_ 19.79
1.26
27
0
0
0
680
0
534
0
0
0
0
0
0
0
0
0
%13A-7.6ocs
1A-r1ov
13A-7.6ocs
1A-r1ov
0.900
0.095
0.900
a
s
s
25.20
2.e6.
25.20
40.70
1.26
19.79,
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1A-rlovd
0.900
s.
25.20
,. 19.79
.01
0
0
0
0
0
0
0
VVV���lll
13A-7.5ocs
0.095
w
2.66
1.26
0
0
0
0
114
87
231
110
1A-r1ov
0.900
w
25.20
19.79
0
0
0
0
27
27
680
534
1A-r1ovd
0.900
w
25.20
41.31
0
0
0
0
0
0
0
0
1A-r1ovd
0.900
w
25.20
19.79
0
0
0
0
0
0
0
0
C
16XI9.Oad
0.406
-
1.59
1.37
198
198
'314
271
276
276
438
- 378
F
22A-tpl
0.089
27.69
0.00
198
16
443
0.
276
10
277
0
6
c) AED excursion
586
Envelope loss/galn
3968
2119
1 16261
1608
12
a) Infiltration
364
103
228
64
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants 230
1
230
2
460
Appllanoestother
0
2000
Subtotal (lines 6 to 13)
4332
2452
1854
4132
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
10
8
8
7
14
Subtotal
4341
2460
1862
4139
15
Duct loads
14%
11%
606
271
14°/u
11%
260
456
Total room load
4947
2732
2122
4595
Air required (cfm)
186
122
80
206
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed,
wr Sft1;=C'1 t- 2020-Nov-11 10:35:54
^ -- -� RightSulte®Universal 2019 19.021 RSLI08101 Paget
tDocuments%Wdghtsoft WAC\Wright Residence.rup Cale - MA Front Doorfaces: N
- wrightsoft° Right-M Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By:
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 77246M799 Email: quickcalcs@aol.com
1
Room name
AHU
Bedroom
2
Exposed wall
0 It
36.0 ft
3
Room height
9.4 ft hea/cool
9.4 ft heat/cool
4
5
Room dimensions
Room area
3.0 x 4.0 it
12.0 ft'
1.0 x 231.0 ft
231 n ft'
Ty
Construction
U-value
Or
I HTM
I Area (ft�
I Load
I Area (ft')
Load
number
(Btuh/Ft'=
(Btuh/ft2)
or perimeter (ft)
(Bluh)
or perimeter (ft)
I (Stuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
8
13A-7.5ocs,
0:095
n
1.31
0
0
0
0
160
120
320
150
10A-m
1.070
'n
6.76
48.78
25.31
0
0
0
0
0
0
0
0
�
1A-rlov
0.900
n
25.20
19.79
0
0
0
0
36
0
907
712
11
1A-rtov
13A-7.5ocs
0:900
0.095
n
a
25.20
2.66
19.79
1.26
0
0
0
0
0
0
0
0
0
141
0
141
0
375
0
178
At
1A-r1ov
13A-7.5ocs
1A-r1ov
0.900
0.095
0.900
e.
s
s
25.20
2.66
25.20
40.70
1.26
19.79
0
0
0
0
0
0
0
0
0
0
0
0
0
9
0
0
9
0
0
25
0
0
12
0
1A-r1ovd
0.900
s
25.20
19.79
0
0
0
0
0
0
0
0
13A-7.5ocs
0.095
w
2.66
1.26
0
0
0
0
28
28
75
36
1A-r1ov
1A-rlovd
0.900
0.900
w
w
25.20
25.20
19.79
41.31
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1A-rlovd
0.900
w_
25.20
19.79
0
0
0
0
0
0
0
0
C
16X19-0ad
0.408
-
1.59
1.37
12
12
19
16
231
231
366
316
F
22A-tpl _
0.989
27.69
0.00
12
0
0
0
231
36
997
0
8
c) AF,D excursion
0
27
Envelope loss/gain
191
16
1
13075
1384
12
a) Infiltration
0
0
676
191
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
1
230
Appliances/other
0
0
Subtotal (lines 8 to 13)
19
16
3751
1804
Less external load
0
0
0
0
Less transfer
0
0
0
0
14
Redistribution
Subtotal
-19
0
-16
0
10
3760
a
1812
15
Duct loads
14%
11%
0
0
14%
11%
525
200
Total room load
Air required (cfm)
0
01
0
01
42115
16l
2012
90
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrtgi�ftasaf r -^ ---�- a- WghtSuite®Unlwrsa12019 19.022020-Nov-11 10:35:641 RSU06101 Page
\Documents\Wdghtsoft WAC\Wright Residence.rup Calc = MJ8 Front Door faces: N
-- wrightsoft° Right-J® Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By:
317 St. Lucie Lane, Fort Plerce, FL 34946 Phone: 772466-6799 Emali: quickcalcs@aol.com
1
Room name
Bath 2
M Bath
2
3
Exposed wall
Room height
0 ft
9.4 ft heat/cool
12.0 ft
9.4 ft heat/000l
4
5
Room dimensions
Room area
6.0 x 12.0 ft
72.0 f?
10.0 x 12.0 It
120.0 ft2
Ty
I Construction
number
U-value
(Btuh/ft'°
Or
HTM
(Btuh/ft2
Area (M
I or perimeter (ft)
Load
I (Btuh)
AreaLoad
or perimeter (ft)
I (Btuh)
Heat
Cool
Gross
I N/P/S
Heat
Cool
Gross
I N/P/S
Heat
Cool
6
11
13A-7.bocs'
10A-m
1A-r1ov
1A-r1ov
13A-7.5ocs
0.095
1,610
0.900
0.900
0.095
n
n
n
n
a
2.66
46.76.
25.20
.25.20
2.66
1.26
25.31
19.79
19.79
1.26
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
o.
0
0
0
0
0
0
0.
113
0
0
0
0
113
0
0
0
-0
300
0
0
0
0
143
11
1A-r1ov
13A-7.5ocs
1A-rlov
1A-r1ovd
0.900
0.095
0.900
0.900
0,095
a
s
s
s
w
25.20
2.66
25.20
25.20
2.66
40.70
1,26
19.79,
.,_ 19.79
1.26
0
0
0
0,
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1A-r1ov
1A-r1ovd
1A-r1ovd
0.900
0,900
0.900
w
w
w
25.20
25.20
25.20
19.79
41.31
19.79
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
TE�13A-7.50cs
C
F
16X19.0ad
22A-tpl
0.408
0.989
-
1.59
27.69
1.37
0.00
72
72
72
0
114
0
99.
0
120
120
120.
12
100
332
164
0
61
c) AED excursion
-1
S
Envelope loss/gain
114
97
1
8231
301
12
a) Infiltration
0
0
225
64
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
114
97
1046
365
Less external load
0
0
0
0
14
15
Less transfer
Redistribution
Subtotal
Duct loads
14%
11°/a
0
6
120
17
0
5
102
11
14%
11%
0
8
1056
147
0
7
372
41
Total room load
Alr required (cfm)
137
5
113
5
1
1
1203
45
413
18
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
we'19ti*=Atftt- 2020-Nov-1 1 10:35:64
- - - RlghtSuite®Univerml2019 19.0.21 RSU08101 Page
..,1DocumentsUrightsoft WAC1Wdght Residence.rup Cale = MJ8 Front Door faces: N
- wrightsoft• Right-J® Worksheet Job:
Entire House Date:
Quick Calcs, Inc, By.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com
1
Room name
Toilet
WIC
2
3
Exposed wall
Room height
6.0 ft
9.4 ft heat/cool
10.0 ft
9.4 ft hest/cool
4
5
Room dimensions
Room area
7.0 x 4.0 ft
28.0 ft'
8.0 x 10.0 ft
80.0 ft'
Ty
Construction
number
U-value
(Btuh4t;
Or
HTM
(Btuh/ftj
Area (ft')
I or perimeter (ft)
Load
I (Btuh)
Area
or perimeter (ft)
Load
I (Btuh)
Heat
I Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
13A-7.5ocs
10A-m
1A-rlov
0.095
1.670
0.900
n
n
n
2.66
46.76
25.20
1.26
25.31
19.79
9
0
0
9
0
0
25
0
0
12
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
1A-r1ov
13A-7.50cs
0.900
0.095
n
a
25.20
2.66
19.79
1.26
0
38
0
38
0
100
0.
48
0
94
0
94
0
250
0
119
L--O
1Arr1ov
13A-7.5ocs
10-r1ov
0.900
0.095
0.900
a
s
s
25.20
2.56
25.20.
40.70
1.26
19.79
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Vh13A-7.50cs
1A-r1ovd
0,900.
0.095
s
w
25.20
2.66
19.79
1.26
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1A-r1ov
1A-r1ovd
1A-r1ovd
0,900
0.900
0.900
w
w
w
25.20
25.20
25.20
19.79
41.31
19.79
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
c
F
16X19-0ad
22A-tpl
0.408
0.989
-
-
1.59
27.69
_
1.37
0.00
28
28
28
5
44
138
38
0
80
80
80
10
_ 127
277
109
0
6
c) AED excursion
-2
-4
Envelope loss/galn
308
gel
1
1
6541
224
12
a) Infiltration
94
26
188
53
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants ® 230
0
0
0
0
Appliences/other
0
0
Subtotal (lines 6 to 13)
402
122
842
277
Less external load
0
0
0
0
14
Less transfer
Redistribution
Subtotal
0
8
410
0
7
129
0
2
844
0
2
279
15
Duct loads
14%
11%
57
14
14%
11%
118
31
Total room load
Air required (cfm)
1
467
18
143
6
1
1
961
36
309
14
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.` wrajo ` 2020-Nov-1 1 10:35:54
- --- �-� WghtSuite®Unlvermi2019 19.0.21 RSU08101 Pages
...\Documents\Wdghtsoft WAC\Wright Residenos.rup Cale - MJ8 Front Door faces: N
-- wrightsoft° Right-J® Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By:
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466.6799 Email: quickcaics@aol.com
1
Room name
Master Bedroom
Hall
2
3
Exposed wall
Room height
48.0 ft
9.4 ft heat/000l
0 ft
9.4 ft heat/cool
4
5
Room dimensions
Room area
1.0 x 340.0 ft
340.0 ft'
7.0 x 4.0 ft
28.0 ft,
Ty
Construction
number
U-value
(Btuh/f12°
Or
I HTM
(Btuh/ft5
Area (ft2
or perimeter (ft)
I Load
(Btuh)
I Area (ft)
or perimeter (ft)
I Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
13A-7.5ocs
10A-m
0.095
1.670
n
n
2,66
46.76
1.26
25.31
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1A-r1ov
0.900
n
25.20
19.79
0
0
0
0
0
0
0
0
11
1A-r1ov
13A-7.5ocs
0.900
0.095
n
a
25.20
2.66
19.79
1.26
0
160
0
140
0
372
0
177
0
0
0
0
0
0
0
0
1A-r1ov
13A-7.5ocs
1A-r1ov
0.900
0.095
0.900
a
s
s
25.20
2.66
25.20
40.70
1.26
19.79
20
160
50
1
110
50
504
292
1260
614
139
989
- 0
0
0
0
0
0
0
0
0
0
0
0
1A-rlovd
13A-7.5ocs
0.900
0.095
s
w
25.20
2.66
19.79
1.28
_ 0,
132
0
60
0
159
0
75
0
0
0
0
0
0
0
0
,A-r1ov
0,900
w
25,20
19.79
0
0
0
0
0
0
0
0
1A-r1ovd
1A-r1ovd
0,900
0.900
w
w
25.20
25.20
41.31
19.79
72
0
3
0
1814
0
2975
0
0
0
0
0
0
0
0
0
C
F
16X19.Oad
22A-tpl
0.408
0.989
-
-
1,59
27.69
1.37
0.00
340
340
340
48
539
1329
465
0
28
28
28
0
44
0
38
0
6
c) AED excursion
686
1
Envelope loss/gain
6269
6320
44
38
12
a) Infiltration
901
254
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
2
460
0
0
Appllanoes/other
0
0
Subtotal (lines 6 to 13)
7170
7035
44
38
Less external load
0
0
0
0
14
Less transfer
Redistribution
Subtotal
0
12
7183
0
10
1045
0
-44
0
0
-38
0
15
Duct loads
14%
11%
1002
777
14%
11%
0
0
Total room load
8185
7822
0
0
Al, required (cfm)
308
3501
0
0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
we tlgi�tntt r ' 2020-Nov-11 10:35:64
-- ---- - RlghtSuiteOUniversal 201919.021RSU08101 Page
1Documents\Wdghtsoft WAC1Wdght Residence.rup Calc = MJ8 Front Door faces: N
- wrightsoft° Right-J® Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-486-6799 Email: quickcaics@aol.com
1
Room name
Living
2
Exposed wall
31.0 ft
3
Room height
11.4 ft heat/cool
4
5
Room dimensions
Room area
21.0 x 13.0 ft
273.0 ft'
Ty
Construction
U-value
Or
HTM
Area W)
Load
I
Area
I
Load
number
I
(Btuh$t'°
(Btuhift2
I or perimeter (ft)
(Btuh)
or perimeter
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6%1�
13A-7.5ocs
0.095
n
2.66
1.28
0_
0
0
0
1OA-m
1.670
n
46.78
25.31
0.
0
0
0
to-rlov
0.900
n
25.20.
19.79
0
0
0
0
11
1A-rlov
13A-7.6ocs
0.900
0:095
n
a
25.20
2.66
19.79
1.26
0
0
0
0
0
0
0
0
�-G
1A-r1ov
0.900
a
25.20
40.70
0
0
0
0
13A-7.5ocs
0.095
s
2.66
1.26
205
109
290
138
IA-rlov
0.900
s
25.20
19.79
0
0
0
0
IA-r1ovd
0.900
s
25.20
19.79
96
96
2419
1900
13A-7.50cs
0.095
w
2.66
,.,
1.26
148
76
203
96
,A-rlov
0.900
w
25.20
19.79
0
0
0
0
1A-rlovd
0.900
w
25.20
41.31
0
0
0
0
1A-rlovd
0.900
w
25.20
19.79
72
72
1814
1425
C
16X19-Oad
0.408
1.59
1.37
273
273
.433
374
F
22A-tpl
0.989
-
27.69
0.00
273
31
858
0
8
c) AED excursion
1391
Envelope loss/galn
6018
5323
12
a) Infiltration
706
199
b) Room ventilation
0
0
13
Internal gains: Occupants @ 230
2
460
Applianoes/other
0
Subtotal (lines 6 to 13)
6724
5982
Less external load
0
0
Less transfer
0
0
Redistribution
0
0
14
Subtotal
6724
5982
15
Duct loads
14%
11%
938
660
Total room load
7662
6642
Air required (cfm)
288
297
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
L wr1g1w1tratPt 2020-Nov-11 10:35:54
�c� •-�•-• -•-••-4•--•-^ WghtSuite®Unlvers�12Q79 19.0.21 RSU08101 Pagel
\DocumentslWdghtsoft WAC\Wdght Residence.rup Calc = MJ8 Front Door faces: N
Duct System Summary Job:
1iVrlgfltS4ft Date:
Entire House By:
Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcaicsoaol.com
Project• •
For: James Wright
6400 Koblegaurd Road, Fort Pierce, FL 34951
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50 in H2O
0 in H2O
0.50 in H2O
0.250 / 0.250 in H2O
0.277 in/100ft
1140 cfm
181 ft
Cooling
0.50 in H2O
0 in H2O
0.50 in H2O
0.250 / 0.250 in H2O
0.277 in/100ft
1140 cfm
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bath 2
c 137
5
5
0.391
4.0
Ox 0
VIFx
12.8
115.0
st2
Bedroom 2
h 4285
161
90
0.389
8.0
Ox 0
VIFx
13.5
115.0
st2
Dining
h 4947
186
122
0.391
8.0
Ox 0
VIFx
12.8
115.0
st1
Kitchen
c 2298
40
103
0.359
7.0
Ox 0
VIFx
24.3
115.0
SO
Kitchen -A
c 2298
40
103
0.380
7.0
Ox 0
VIFx
16.5
115.0
st1
Laundry
c 693
13
31
0.369
5.0
Ox 0
VIFx
20.6
115.0
st1
Living
c 3321
144
149
0.346
7.0
Ox 0
VIFx
29.7
115.0
st4
Living -A
c 3321
144
149
0.348
7.0
Ox 0
VIFx
28.5
115.0
st4
M Bath
h 1203
45
18
0.367
5.0
Ox 0
VIFx
21.3
116.0
st3
Master Bedroom
c 3911
154
175
0.277
8.0
Ox 0
VIFx
45.7
135.0
sty
Master Bedroom -A
C 3911
154
175
0.278
8.0
Ox0
VIFx
45.1
135.0
sty
Toilet
h 467
18
6
0.363
4.0
Ox 0
VIFx
22.9
115.0
st3
Nnc
h 961
36
14
0.350
4.0
Ox 0
VIFx
27.7
115.0
st3
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
SO
Peak AVF
308
350
0.277
642
10.0
0 x 0
VinlFix
st3
st3
Peak AVF
407
389
0.277
518
12.0
0 x 0
VinlFlx
st2
Peak AVF
166
95
0.389
476
8.0
0 x 0
VinlFlx
st4
Peak AVF
288
297
0.346
545
10.0
0 x 0
VinlFlx
st1
Peak AVF
279
359
0.359
457
12.0
0 x 0
VinlFlx
{� wright1`sof[, 2020-Nov-1 1 10:35:55
„ .��• ,....... �,.e RlghtSulte®Universal 2019 19.021 RSU08101 Page 1
j4 i� ..,1DocumentslWrightsoft WACUright Residenoe.rup Celc = MJ8 Front Door faces: N
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb2
0x 0
1140
1140
0
0
0
0
Ox 0
VIFx
•. ' wrightsoft"
wr� .,. .,.�,,>.,.... RlghtSulte®Universal 2019 19.0.21 RSU08101
fri�....1Documents\Wdghtsoft HVAC%Wright Residence.rup Cale - MJ8 Front Door faces: N
2020-Nov-11 10:35:55
Page 2
FORM R405-2020
.ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows** Description
a. U-Factor: Sgl, U=0.65
SHGC: SHGC=0.25
b. U-Factor. Sgl, U=0.65
SHGC: SHGC=0.30
c. U-Factor: N/A
SHGC:
d. U-Factor. N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): NIA
6400 Koblegaurd Road, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Polystyrene Bead A%R=0.0
1724.30 ft2
b. Frame - Wood, Adjacent
R=11.0
214.67 ft2
1
c. N/A
R=
ft2
2
d. N/A
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Roof Deck (Unvented)
R=20.0
1718.00 ft2
1718
b. N/A
R=
ft2
Area
c. NIA
R=
ft2
232.00 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Living, Ret: AHU, AH: AHU
6 80
216.00 ft2
13. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
34.2 SEER:16.00
ft2
7,799 ft,
0.274
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1718.00 ft2
b. NIA R= ft2
c. NIA R= ft2
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
kBtu/hr Efficiency
27.0 COP:1.00
Cap: 50 gallons
EF: 0.95
CF. Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/9/2021 9:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Wright Residence Builder Name:
Street; 6400 Koblegaurd Road Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL, 34951 Permit Number:
Y
Owner: James Wright Jurisdiction: St. Lucie County
w=
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attics aces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be Installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
Insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
Installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
Installation readily conforms to available space shall
Showerltub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection Of og walls shall be in accordance wnt the provisions of ICC-400.
4/9/2021 9,48 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the. home.
1. New construction or eAtting
2. Single family or multiple family
3: Number of units, if multiple family
4. "Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftJ
7. Windows*" Description
a. U-Factor. Sgl, U=0.65
SHGC: SHGC=0.25
b. U-Factor. Sgf, U=0.65
SHGC: SHGC=0.30
c. U-Factor. N/A
SHGC:.
d. U-Factor. N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
6400 Koblegaurd Road, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Polystyrene Bead
Ag¢t=0.0
1724.30 ft2
- b. Frame - Wood, Adjacent
R=11.0
214.67 ft2
1
c. N/A
R=
ft2
2
d. N/A
R=
ft2
11. Ceiling Type and insulation level
Insulation
Area
No ,
a. Roof DecW (Unvented)
R=20.0
1718.00 ft2
1718
b. N/A
R=
ft2
Area
c. N/A
R=
ft'
232.00 ft2
12. Ducts, location & insulation level
F2 ft'
a. Sup: Living, Ret: AHU, AH: AHU
6 86
216.00 ft2
13. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
34.2 SEER:16.00
ft2
7.799 ft.
0.274
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation . R=0.0 1718.00 ft2
b. NIA R= ftZ
c. NIA R= ft2
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida. Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Codecompliant features.
Builder Signature: Date:
Address of. New Home: City/FL Zip:
kBtulhr Efficiency
27.0 COP:1.00
Cap: 50 gallons
EF: 0.95
CF, Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient'
mortgage (EEM) incentives if you obtain a Florida Energy•Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the. Florida Building Code,- Energy Conservation, if'not DEFAULT.
4/9/2021 9:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
2020 - AIR -BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION .COMPONENT CRITERIA
Project Name: Wright Residence Builder Name:
Street: 6400 Koblegaurd Road Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL , 34951 Permit Number:
Y
U
Owner. James Wright Jurisdiction: St. Lucie County
W
x
Design Location: FL, Fort -Pierce .
r,
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be Installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air.barder.
not be used as a sealing material.
Breaks, or joints in the air border shall be sealed,
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in- any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed._
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attics aces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities*within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a'thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum. -
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air border.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shail'include the air barrier.
Rim joists shall be insulated.
Floors
The air border shall be installed at any exposed, edge of
Floor framing cavity Insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all' perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace wells.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on.
Installation readily conforms to the available cavity
spaces.
Garage. separation .
Air sealing shall be provided between the garage and coriditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
Installation readily conforms to available space shall
AYILund hphlnri piping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electdcallphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
WAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
hatween fire sprinkler cover Metes god walls or rgliongs.
a. In addition; inspection or Ing walls shall be in accordance with the provisions of ICU-400.
4/9/2021 9,48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1