Aal FL# FL10626-R20
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived L`:1
;
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany, NJ 07054
(800)766-3411
mstieh@gaf.com
Authorized Signature Robert Nieminen
Ireith@nemoetc.com
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(800)766-3411
TechnicalQuestionsGAF@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
(mm Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/17/2021
Validated By John W. Knezevich,PE
0 Validation Checklist-Hardcopy Received
Certificate of Independence FL10626 R20 COI 2021 01 COI NIEMINEN.pd
Referenced Standard and Year(of Standard) Standard year
ASTM D1970 2015
ASTM D4533 2015
ASTM D4798 2011
ASTM D4869 2016
ASTM D5035 2011
ASTM D6164 2011
ASTM D6757 2016
FM 4474 2011
FRSA/TRI,6th Edition 2018
r
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02/01/2021
Date Validated 02/07/2021
Date Pending FBC Approval 02/09/2021
Date Approved 04/13/2021
Date Revised 04/14/2021
Summary of Products
FL# Model,Number or Name Description
10626.1 �- GAF Roof Underlayments Roofing Underlayments for use in sloped roof systems
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10626 R20 II 2021 01 28 FINAL ER GAF UNDERLAYMENTS FL10626-
Approved for use outside HVHZ:Yes R20.0f
Impact Resistant:N/A Verified By: Robert Niemien 59166
Design Pressure:+N/A/-442.5 Created by Independent Third Party:Yes
Other: 1.)The design pressure noted in this Evaluation Reports
application relates to one particular FL10626 R20 AE 2021 01 28 FINAL ER GAF UNDERLAYMENTS FL10626-
underlayment system. Refer to ER Section 5.8.3 R20.pdf
for details. 2.)Refer to ER Section 5 for other Created by Independent Third Party:Yes
Limits of Use.
—iJ Next
Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824
The State.of Florida is an AA/EEO employer.Copght 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
flit Gard
t i
NEMO etc.
Certificate of Authorization#32455
353 Christian Street,Unit#13
� Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION .O.
GAF Evaluation Report 01506.04.08-R20
1Campus Drive FL10626-1120
Parsippany, NJ 07054 Date of Issuance:04/25/2008
(800)766-3411 Revision 20:01/28/2021
SCOPE:
This Evaluation Report is issued under Rule'61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has.been reviewed by Robert Nieminen,
P.E.for use of the product underthe Florida Building Code and Florida Building Code,Residential Volume. The products
described herein have been evaluated for compliance with the 71h Edition(2020) Florida Building Code sections noted
herein.
DE5CRIPTION -=GAF Roof.UnclMaymentS
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the.Quality Assurance or the production facility location(s). NEIVIO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
-41
Robert J.M.Nieminen,P.E. �� w The facsimile seal appearing was authorized by Robert
* �h
Florida Registration No.59166,Florida DCA ANE1983 4 Nieminen,P.E.on 01/28/2021.This does not serve as an"y,��;�<x,�s��wy ;,
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEW ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 NEMO ETC,LLC
c
NEMO l etc.
ROOFING COMPONENT EVALUATION:
SCOPE'1.
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: GAF Roof Underlayments,as produced by GAF,have demonstrated compliance with the
following sections of the 7"Edition(2020)Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth
herein.
STANDARDS:2.
Se"coon Pro'e „ Standard Year
1504.3.1 Wind resistance FM 4474 2011
1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015
R905.1.1,R905.2.8.2
1507.1.1.1(2&3,Exception), Tear Strength ASTM D4533 2015
1507.1.1.1(5)/R905.1.1.1(2&3,
Exception),R905.1.1.1(5)
1507.1.1.1(2&3,Exception), Tensile strength ASTM D5035 2011
1507.1.1.1(5)/R905.1.1.1(2&3,
Exception),R905.1.1.1(5)
1507.1.1.1(5)/R905.1.1.1(5) Liquid water transmission ASTM D4869 2016
1507.1.1/R905.1.1 Material standard ASTM D6757 2016
1507.3.3,R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2 Material standard ASTM D6164 2011
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Entity Examination Reference Daie
ERD(TST 6049) ASTM D1623&FRSA/TRI(Slippage) G34150.08.11 11/14/2011
ERD(TST 6049) ASTM D6164(GA) G40630.01.14-2B 01/07/2014
ERD(TST 6049) ASTM D6164(GA) G46160.09.14-3A 09/09/2014
ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-3 03/01/2017
ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-4 03/01/2017
ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-1 03/08/2017
ERD(TST6049) ASTM D1970(IN) GAF-SC16440.12.17 12/31/2017
Intertek(TST 1558) ASTM D4869(Dadra,India) F8549.02-106-18 11/08/2016
NEMO(TST 6049) Physical Properties(ON) 4q-GAF-I9-SSMBB-03.A 05/13/2019
PRI(TST 5878) ASTM D1970(IN) GAF-324-02-01 11/30/2011
PRI(TST 5878) ASTM D226(OK) GAF-339-02-01 03/13/2012
PRI(TST 5878) ASTM D4798(NC) GAF-349-02-01 07/03/2012
PRI(TST 5878) Wind Uplift GAF-434-02-01 09/16/2013
PRI(TST 5878) Wind Uplift GAF-434-02-03 09/16/2013
PRI(TST 5878) Wind Uplift GAF-434-02-04 09/16/2013
III PRI(TST 5878) ASTM D4533(various) GAF-818-02-01 12/05/2017
PRI(TST 5878) ASTM D1970(AL) MSA-047-02-01 04/11/2018
PRI(TST 5878) ASTM D4533(LA) GAF-826-02-01 06/4/2018
PRI(TST 5878) ASTM D4533(Dadra,India) GAF-847-02-01 06/4/2018
PRI(TST 5878) ASTM D4533(Dadra,India) GAF-914-02-01 04/10/2019
PRI(TST 5878) ASTM D4533,D5035(VA) 376T0012 07/15/2019
PRI(TST 5878) ASTM D4533(Umerkui Kilvani,India) 376T0018 07/31/2019
PRI(TST 5878) ASTM D4533(Parzai,India) 376T0018 07/31/2019
PRI(TST 5878) ASTM D1970(AR) 376T0032 10/22/2019
PRI(TST 5878) ASTM D5035(various) 376TO103 09/11/2020
UL(TST 1740) ASTM D6757(TX) 02NK22569 06/04/2002
NEMO ETC,LLC Evaluation Report 01506.04.08-1120
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R20
GAF Roof Underlayments Revision 20:01/28/2021
Page 2 of 8
MEMO etc.
UL(TST 1740)� ASTM D6757(NC) IONK11990 05/18/2011
NEMO ETC Traceability FBC Cross-Listing 04/22/2020
UL,LLC(QUA 9625) Quality Control Service Confirmation 09/29/2020
UL,LLC(QUA 9625) Quality Control Service Confirmation(AL) 05/04/2020
UL,LLC(QUA 9625) Quality Control Florida BCIS Current
4. PRODUCT
ProductMaterial 5andard Plants)
v. ..,
4.1 Liberty"'SBS Self-Adhering Base/Ply ASTM D1970 Mt.Vernon,IN
Sheet Savannah,GA
4.2 StormGuard®Film Surfaced Leak Barrier ASTM D1970 Mt.Vernon,IN
Savannah,GA
Arkadelphia,AR
4.3 WeatherWatch®Mineral Surfaced Leak ASTM D1970 Mt.Vernon,IN
Barrier Savannah,GA
Tuscaloosa,AL
Deck-Armor'""Premium Breathable Roof 1507.1.1.1(2&3,Exception)/
4.4 Deck Protection R905.1.1.1(2&3,Exception) Dadra,India
FeltBuster®High-Traction Synthetic 1507.1.1.1(2&3,Exception), Dadra,India
4.5 Roofing Felt 1507.1.1.1(5)/R905.1.1.1(2&3, Richmond,VA
Exception),R905.1.1.1(5) Spartanburg,SC
4.6 Shingle-Mate®Roof Deck Protection ASTM D226,Type II(Table 1) Pryor,OK
1507.1.1.1(2&3,Exception)/
4.7 StormSafeT""Anchor Sheet R905.1.1.1(2&3,Exception) North Bay,ON
1507.1.1.1(2&3,Exception)/ Dadra,India
4.8 Tiger Paw—Roof Deck Protection R905.1.1.1(2&3,Exception) Parzai,India
Umerkui Kilvani,India
4.9 VersaShield®Fire-Resistant Roof Deck ASTM D6757 Conover,NC
Protection
4.10 Ruberoid®Mop Granule ASTM D6164 Savannah,GA
FRSA/TRI09-18
4.11 Ruberoid®Mop Granule FR ASTM D6164 Savannah,GA
FRSA/TRI09-18
5. LIMITATIONS'
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
I'I accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
j5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
MEMO ETC,LLC Evaluation Report 01506.04.08-R20
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R20
GAF Roof Underlayments Revision 20:01/28/2021
Page 3 of 8
NEMO etc.
5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
1 within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1. ROOF COVER OPTIONS'Z 5
e
FBt 5echon 1507 2„ .... ..1507 3 , 1507,4 on`d 1507.5 1507,7. 1 S07 8 and 2507 9
Cla and Concrete Tile Metal
Asphalt y Panels Shingles Slateor Shin wood
Underlayment Shm les Mechanical Adhesive Slate Type
gles Shakes
�,
Attach - a Set_ , .. �Shingles
Liberty'"SBS Self-Adhering Yes Yes
Base/Ply Sheet Yes No No No No No 150711.3/ 150�1oint t1.3/
R905.1.1.3) R905.1.1.3)
Yes Yes
StormGuard"Film Surfaced Leak
Yes No No Yes Yes Yes 1s 15o�1 s, Coint tig%
Barrier 50�1.1. /
R905.1.1.3) R905.1.1.3)
WeatherWatch®Mineral Surfaced Yes Yes
Leak Barrier Yes No No No No No 10int strips, Goint strips,
507.1.1.3/ 1507.1.1.3/
R905.1.1.3) R905.1.1.3)
Deck-Armor—Premium Breathable Yes No No Yes Yes Yes No No
Roof Deck Protection
FeltBuster®High-Traction
Yes No No No No No No No
Synthetic Roofing Felt
Shingle-Mate®Roof Deck
Yes No No No No No No No
Protection
Tiger Paw"Roof Deck Protection Yes No No Yes Yes Yes No No
VersaShield®Fire-Resistant Roof
Yes No No No No No No No
Deck Protection
Yes Yes
Ruberoid®Mop Granule No (Cap Sheet in (Cap Sheet in No No No No No
2-ply system) 2-ply system)
See 5.6.1
Yes Yes
Ruberoid®Mop Granule FR No (Cap Sheet in (Cap Sheet in No No No No No
2-ply system)
2-ply system)
See 5.6.1 1 E 1
5.6.1 Adhesive-set is limited to use of following underlayment/tile-adhesive combinations.
TABLE 1'A ALLOWABLE LINDEI2LAYMENTtTILf ADHESIVE COMBINATION51
M. .._.
Underlayment Adhesive Florida Product Approval
.�.
Ruberoid®Mop Granule;Ruberoid®Mop Granule FR Dupont"Tile Bond'"Roof Tile Adhesive" FL22525
'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
MEMO ETC,LLC Evaluation Report 01506.04.08-R20
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-1120
GAF Roof Underlayments Revision 20:01/28/2021
Page 4 of 8
MEMO I etc.
5.7 Allowable Substrates:
TAKE:2:.SUBSTRATE QPTIONS FOR AuHEREO UNOERLAXMENTS
e sUnder)ayment Apphcatitin ';Primer'; ..,.. Substrates
Liberty'"SBS Self-Adhering Base/Ply Sheet
StormGuard®Film Surfaced Leak Barrier self-adhering (Optional) plywood
ASTM D41
Weather Watch®Mineral Surfaced Leak Barrier
Liberty-SBS Self-Adhering Base/Ply Sheet
StormGuard®Film Surfaced Leak Barrier self-adhering None ASTM D226 felt,Type II
Weather Watch®Mineral Surfaced Leak Barrier
Liberty'"'SBS Self-Adhering Base/Ply Sheet
StormGuard®Film Surfaced Leak Barrier self-adhering ASTM D41 metal(flashing metal,valley metal,
Weather Watch®Mineral Surfaced Leak Barrier etc.)
Ruberoid°Mop Granule
hot asphalt ASTM D41 structural concrete
Ruberoid°Mop Granule FR
Ruberoid®Mop Granule hot asphalt None GAFGLAS®#80 Ultima-Base Sheet
Ruberoid®Mop Granule FR or Ruberoid®20 Smooth
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but—for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein(for other underlayment systems).
5.8.3 Wind Resistance for underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined'in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-442.5 psf.
Deck: Min.2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction
Base Sheet: GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet,GAFGLAS#80 Ultima Base Sheet,GAFGLAS Ply 4,
Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312,Type IV hot asphalt at 20
to 25 Ibs/square.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
NEMO ETC,LLC Evaluation Report 01506.04.08-1120
Certificate of Authorization#32455 7`EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R20
GAF Roof Underlayments Revision 20:01/28/2021
Page 5 of 8
NEMO etc.
5.8.3.2 Mechanically-Attached Base Sheet:The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#2 Maximum Design Pressure=-45 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 UltimaT" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min. 1.25-inch long ring shank nails through 32 ga.,1-5/8-inch diameter tin caps spaced 9-inch o.c.
at the min.4-inch wide side laps and 9-inch o.c.at two(2),equally spaced,staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
#3 Maximum Design Pressure=-75 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction. -
Base Sheet: GAFGLAS® #80 UltimaT" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min.1.25-inch long ring shank nails through 32 ga.,1-5/8-inch diameter tin caps spaced 8-inch o.c.
at the min.4-inch wide side laps and 8-inch o.c.at three(3),equally spaced,staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
#4 Maximum Design Pressure=-97.5 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 UltimaTm Base Sheet or Ruberoid® 20 Smooth mechanically attached with 11 ga.,
min.1.25-inch long ring shank nails through 32 ga.,1-5/8-inch diameter tin caps spaced 4-inch o.c.
at the min.2-inch wide side laps and 4-inch o.c.at four(4),equally spaced center rows in the field
of the sheet.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
NEW ETC,LLC Evaluation Report 01506.04.08-R20
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-1120
GAF Roof Underlayments Revision 20:01/28/2021
Page 6 of 8
NEM01 etc.
5.9 Exposure Limitations:
-
- e TAB!E 3 EXPOSURE LIMITATIONS' ux t
r d R f C er Maximum
h Underlayment s Plnstallati
�, on Type Exposure
(days)
Deck-ArmorTM Premium Breathable Roof Deck Protection,FeltBuster®High-Traction
Synthetic Roofing Felt,Shingle-Mate®Roof Deck Protection,StormSafeT Anchor
Sheet,Tiger Paw'"Roof Deck Protection,VersaShield®Fire-Resistant Roof Deck Mechanically attached 30
Protection,Liberty—SBS Self-Adhering Base/Ply Sheet,StormGuard®Film Surfaced
Leak Barrier and WeatherWatch®Mineral Surfaced Leak Barrier
Ruberoid®Mop Granule and Ruberoid®Mop Granule FIR Adhesive-set tile roof system 180
Mechanically attached UNLIMITED
5.10 Tile Slippage Limitations:When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
=TABLE 4. TllE SlIRPAGE LIMITATIONS FOR DIRECT DECK-TILE[NSALLA7ION5
Underlayment,, Tile Profile x, Staging Method ,..,. ., _ ;IVlaximu`m`Stagirig$lope.
e._
Flat Max.10-tile stack 4:12
Ruberoid®Mop Granule Flat Max.6-tile stack(4 over 2) 5:12
Lugged Max.10-tile stack 5:12
Ruberoid®Mop Granule FR Flat or Lugged Max.6-tile stack(4 over 2) 5:12
Lugged Max.10-tile stack 4:12
•
6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application and prime the substrate(if applicable).
Deck Armo Mi lum Breathable Roof Deck Pratectiori'or Th'r,PawT°"Roof Deck Pro#ectlon ,
6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception)
or 1507.1.1.1(3,Exception)or FBC Residential R9O5.1.1.1(2,Exception)or R905.1.1.1(3,Exception)for the type
of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
6 4 FeltBuster Hlgh 7raetion Synthetrc Roofing Felt a
M
6.4.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception),
1507.1.1.1(3,Exception)or 1507.1.1.1(5)or FBC Residential R9O5.1.1.1(2,Exception),R905.1.1.1(3,Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
6 5 5torrnsafeT"^Anchat sheet• ��
6.5.1 StormSafeTm Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems.
6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception)
or 1507.1.1.1(3,Exception)or FBC Residential R905.1.1.1(2,Exception)or R9O5.1.1.1(3,Exception)for the type
of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
NEMO ETC,LLC Evaluation Report 01506.04.08-1120
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R20
GAF Roof Underlayments Revision 20:01/28/2021
Page 7 of 8
NEMO etc.
6.5.3 One the same day, install Liberty'"" SBS Self-Adhering Base/Ply; StormGuardm Film Surfaced Leak Barrier or
WeatherWatch®Mineral Surfaced Leak Barrier over the StormSafeTm Anchor Sheet.
6 6.' Shingle Nlate�',Roof Deck Protection
6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM
D226,Type II)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
r
6 7 Ver`saShteld6 Fire Resistant Roof Deck Protection "
6.7.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM
D6757)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be
installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6 8 Llberty'"' SRS Self-Adhering BaselPly;Sheet, StarrnGuard® 3Filn Surfaced Leak BalCr�er or WeatherWatW,
Mi6641"5u_rfaeed l eak Barrier
-
6.8.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
6.8.2 Back-nailing is required. Back-nailing shall consist of Approved cap nails spaced 18-inch o.c.,encapsulated within
min.4-inch side laps.
6.8.3 When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt,the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.8.4 Liberty'" SBS Self-Adhering Base/Ply Sheet, StormGuard® Film Surfaced Leak Barrier or WeatherWatch®
Mineral Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch wide rolls to
seal plywood deck joints prior to installation of the primary underlayment system.
�6 9,< Ruberold@ Mop Granule,Ruberoid��Mop GranuleFR
_� .
6.9.1 Shall be installed in compliance with requirements as an alternate to the"Hot Asphalt Applied Cap Sheet"in the
"Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth
Edition,and the manufacturer's installation instructions.
6.9.2 Refer to Sections 5.8.2 and 5.8.3 herein for attachment limitations.
6.9.3 Refer to Table 4 for tile staging limitations.
7. BUILDING PERMIT •
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS.
Contact the named CA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALITY 1
UL,LLC.—QUA9625;(414)248-6409;karen.buchmann@ul.com
-END OF EVALUATION REPORT-
NEW ETC,LLC Evaluation Report 01506.04.08-R20
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R20
GAF Roof Underlayments Revision 20:01/28/2021
Page 8 of 8
a ST. LUCIE WORKS
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code-Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Required Sections of Attachments Required
Roof System the Permit 'Application See List Below
Form
Low Slope Application A,B,C
Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7
Asphaltic Shingles A,B, D 124;567
Concrete or Clay Tile A, B, D, E 123,�4k567
Metal Roofs A,B, D 1,234;5fiT
Wood Shingles and A, B, D i 4-45,67
Shakes
Other As'Applicable %A6'.6.7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128
4. Other Component of Product Approval
5. Municipal Permit Application
6. Owners Notification for Roofing Considerations(Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18,2021
T
ST. LUCIE WORKS
Section A (General Information)
Master Permit No. Process No.
Contractors Name: �f License#
Job Address—? `�� y c— R� `urt / `erce FL 0iTj
ROOF CATEGORY
0 Low Slope 0 Mechanically Fastened Tile 0 Mortar/Adhesive Set Tiles
0Asphaltic Shingles O Metal Panel/Shingles Mood Shingles/Shakes
0 Prescriptive BUR-RAS 150
ROOF ROOF TYPE
0 New roof 0 Repair 0 Maintenance JvReroofing 0 Recovering
.ROOF SYSTEM INFORMATIO
Low Slope Roof Area (SF) Steep Sloped Roof Area(SF) I-,( oo Total(SF) V ll
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
Ilk
ST. LUCIE WORKS
Section C(Low Slope Roof) Surfacing:
Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufacturer Zone 1':_" oc @ Lap,#Rows—
(If a component is not used,identify as"NA")
Zone 1:—" oc @ Lap,#Rows
System Manufacturer: Zone 2:_." oc @ Lap,#Rows
Zone 3:—." oc @ Lap,#Rows .
Product Approval No.:
Number of Fasteners Per Insulation Board:
Design Wind Pressures,From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3:
Zone 1':—Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable:
Max. Design Pressure,from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping,
system: Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing,Coping, Etc..
Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base
Type: Flashing,Component Material,Material'Thickness, Fastener
Type,Fastener Spacing or Submit Manufacturers Details that
Gauge Thickness: Comply with RAS 111 and Chapter 16..
Slope:
Anchor/Base Sheet&No.df Ply(s):
An Sheet Fastener/Bonding Material: FT.
Insulation Base Layer:
Base Insultation Size and Thickness: Parapet
Base Insulation Fastener/Bonding Material: Height
Top Insulation Layer:
Top Insulation Size and Thickness: FT.
Top Insulation Fastener/Bonding Material:
Mean
Base Sheet(s)&No.of Ply(s): Roof
Base Sheet Fastener/Bonding Material: Height
Ply Sheet(s)'&No.of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Y ..
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
(v Roof System Manufacturer: P
Notice of Acceptance Number:
Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations):
Zone 1: Zone 2e: Zone 2n: Zone 2r: Zone 3e: Zone 3r:
Deek Type: � rJ
Type.UndedaymbhtPeel ,, <5*L f�
R f Sipe
Il
Insulationb
Fire BaCner
Ridge Ve 'HOMM' Fastener Type&.,Spacuig A.
(� UG (0.:_ �/� ��
,.
L.Ac) 9-y\
adhesive Type_ -
.. Type Cap`•Sf�ee� �r '
Mean RdoP Heights 1' a - Roof,Cdvedn
Type SrS Drip. «
ST. LUCIE 'WORKS
Section E(Tile Calculations)
For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mf.If the Mf values,
are greater than or equal to the Mrvalues,for each area of the roof,then the the attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: _ Product Approval Mi
(Zone 2e: _ X - = _�.- aM,�,. Product Approval Mf
(Zone 2n: X;7L -j - = Product Approval Mf-
(Zone 2r: R110- Product Approval Mf
(Zone 3e: =M Product Approval Mf-
(Zone 3r: Product Approval Mf
Method 2"Simplified Tile Calculations Per Table Below"
Required Moment of Resistance(Mr)From Table Below Product Approval Mf
Mr required Moment Resistance*
Mean Roof Height Roof Slope 15' 20' 25' 30' 40'
2:12 34.4 36.5 38.2 39.7 42.2
3:12 32.2 34.4 36.0 37.4 39.8
4:12 30.4 32.2 33.8 35.1 37.3
5:12 28.4 30.1 31.6 32.8 34.9
6:12 2 . 1 28.0 29.4 30.5 32.4
7:12 24.4 1 25.9 27.1 28.2 30.0
*Must be used in conjunction with a list of moment based tile systems
• For Uplift based tile systems use Method 3. Compare the values for F'with the values for Fr If the F'values are greater than or
equal to the Fr values,for each area of the roof,then the tile attachment method is acceptable.
Method 3"Uplift Based Tile Calculations Per RAS 12T
(Zone 1: x L =x W:= )-W: cos r =Fri Product Approval F'
(Zone 2e: x L =x W:= )-W: cos r =Fr2e Product Approval F'
(Zone 2n: x L =x W:= )-W: cos r =Fr2n Product Approval F'
(Zone 2r: x L =x W:= )-W: cos r =Fr2r Product Approval F'
(Zone 3e: x L =x W:= )-W: cos r =Fr3e Product Approval F'
(Zone 3r: x L =x W:= )-W: cos r =Fr3r Product Approval F'
Where to Obtain Information
Description Symbol Where to find
From applicable table in RAS 127 or by an engineering analysis
Design Pressure Zones 1,2e,2n,2r,3e,3r
prepared by PE based on ASCE 7
Mean Roof Height H Job Site
Roof Slope 0 Job Site
Aerodynamic Multiplier a Product Approval
Restoring Moment due to Gravity Mg Product Approval
Attachment Resistance Mf Product Approval
Required Moment Resistance Mg Calculated
Minimum Attachment Resistance F' Product Approval
Required Uplift Resistance Fr Calculated
Average Tile Weight W Product Approval
Tile Dimensions L=length W=width Product Approval
All calculations must be submitted to the building official at the time of permit application.