HomeMy WebLinkAboutProduct Data SubmittalJohnson 01( Controls ! =RECE.PRODUCT DATA SUBMITTAL FIRE ALARM SYSTEM PRODUCT DATA SUBMITTALS PREPARED FOR: WW,AF- ELEVEIR a . E 7-Eleven, Inc. United States 7310 Indrio Rd, Fort Pierce, FL 34951 Prepared By: JOHNSON CONTROLS INTERNATIONAL O� L'Sc" pow Ax ' vt P V �► tOR10 P ; 48d�7NAL �4B1��DOg1� 14200 E. EXPOSITION AVE., AURORA, COLORADO 80012 14 GIBBENS DRAKE SCOTT, INC 9201 E 63r4 STREET, SUffE 100 RAYTOVK MISSOURI 64133 ENGIIOMWG FLARMACOA04630 DF-60953:C ES-50X Intelligent Addressable FACP with Communicator General The ES-50X is the latest intelligent addressable fire alarm control panel (FACP) from Fire-Lite Alarms and is a direct replacement for the MS-9050UD/LS. The ES-50X comes with a pre -installed communi-cator and supports up to 50 addressable devices in any combination of detectors or modules. With an extensive list of powerful features, the ES-50X programs just like Fire-Lite's other addressable panels, yet fits into applications previously served only by conventional panels. The pre -installed ]POTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL -MOD or CELL -CAB -FL. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk -test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTMF). Features • Listed to UL Standard 864, 10th edition • Pre -installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator • Optional CELL -MOD or CELL -CAB -FL GSM Central Station Communicator overAlarmNet® • Compatible with SWIFT® wireless devices • Auto -programming (learn mode) reduces installation time. Reports two devices set to the same address • Two independently programmable, built-in Style Z (Class A) or Style Y (Class B) NAC circuits • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices • Notification Appliance Circuit End of Line resistor matching • Four programmable function keys for ease of maintenance • Two programmable relays and one fixed trouble relay • Built-in Programmer • Integral 80-character LCD display with backlighting • Real-time clock/calendar with automatic daylight savings control • History file with 1,000 event capacity • Addressable sounder base • Multi -criteria detector (smoke, heat, CO) with programmable response • Control module delay timer • Automatic detector sensitivity testing (NFPA 72 compliant) • Automatic device type -code verification • Point trouble identification • Waterflow selection per module point • Alarm verification selection per detector point 18 FII'e•LITe''Alc'1YIl1S by Honeywell • Maintenance alert warns when smoke detector dust accumula- tion is excessive • One -person audible or silent walktest with walktest log & printout • System alarm verification selection per detector point • PAS (Positive Alarm Sequence) and Pre -signal per point (NFPA 72 compliant) • Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus • Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator • Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP • Supports LiteSpeed rm and CLIP protocols • SLC operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with twisted, unshielded wire • Single addressable SLC loop which meets NFPA Class B and Class A requirements • 50 addressable device capacity (any combination of addressable detectors and modules) • Compatible with Fire-Lite's addressable devices (refer to the SLC Wiring Manual) NOTIFICATION APPLIANCE CIRCUITS (NA CS) • Two independently programmable output circuits. Circuits can be configured for the following outputs: — Style Y (Class B) — Style Z (Class A) • Silence Inhibit and Autosilence timer options • Continuous, March Time, Temporal, or California code for main circuit board NACS with two -stage capability • Selectable strobe synchronization per NAC • 2.5 A special application, 250mA regulated, total power for NACs NOTE. Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A PROGRAMMING AND SOFTWARE • Autoprogramming (learn mode) reduces installation time DF-60953:C • 7/16/2018 — Page 1 of 4 • Custom English labels (per point) may be manually entered or selected from an internal library file • Two programmable Form-C relay outputs • 50 software zones • Continuous fire protection during online programming • Program Check automatically catches common errors not linked to any zone or input point • OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows&based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on www.firelite.com. User interface LED INDICATORS • Fire Alarm (red) • CO Alarm (red) • AC Power (green) • Supervisory (yellow) • Trouble (yellow) • Ground fault (yellow) • Battery fault (yellow) • Disabled (yellow) • Maintenance (yellow) • Communication (yellow) • Alarm Silenced (yellow) • F1-F4 Programmable Function Keys (yellow) KEYPAD • 16 key alpha -numeric pad • Acknowledge • Alarm Silence • Drill (Manual Evacuate) • Four (4) programmable function keys • Reset (lamp test) Product Line Information ES-50X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, pre -installed IPOTS-COM communicator, chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc. (For ES-50XC, refer to DF- FS-Tools: Programming software for Windows® -based PC com- puter. Available for download at www.firelite.com. CELL-CAB-FUCELL-MOD: Optional GSM communicator . IPOTS-COM: Dual technology (POTS and I municator. (replacement board DP-ES-R: Optional dress panel for the ES-50X. TR-CE: Optional trim ring for semi -flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries & CHG-75. BB-55F: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi -modules in a BB-6F cabinet. CHG-75: Battery charger for lead -acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead -acid batteries with a rating of 55 to 120 AH. Requires additional BB-55F for mount- ing. BAT Series: Batteries, see data sheet DF-52397. PRN Series: UL listed compatible event printer. Uses tractor -fed paper. Page 2 of 4 — DF-60953:C • 7/16/2018 OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. COMPATIBLE ANNUNCIATORS ANN-80: Remote, red LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. ANN-100: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. ANN-1/0: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DF- 60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a con- nection for a serial or parallel printer. (See DF-52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. SD365: Addressable low -profile photoelectric smoke detector. Lite- Speed only. SD365-IV: Addressable low -profile photoelectric smoke detector. Ivory. LiteSpeed and CLIP mode. SD365T: Addressable low -profile photoelectric smoke detector with thermal sensor. LiteSpeed only. SD365T-IV: Addressable low -profile photoelectric smoke detector with thermal sensor. Ivory. LiteSpeed and CLIP mode. SD365R: Remote test capable addressable photoelectric smoke detect or use with DNR(W11) duct detector housing. LiteSpeed only. S 5R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(WW) duct detector housing. Ivory. Lite- Tpeed and CLIP mode. H365: Low -profile 135•F fixed thermal sensor. LiteSpeed only. H365-IV: Low -profile 135°F fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. H365R: Low -profile, intelligent, rate -of -rise thermal sensor. Lite- Speed only. H365R-IV: Low -profile, intelligent, rate -of -rise thermal sensor. Ivory. LiteSpeed and CLIP mode. H365HT: Low -profile intelligent 190°F/88°C fixed thermal sensor. LiteSpeed only. H365HT-IV: Low -profile intelligent 190°F/88°C fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. Legacy Devices SD355: Addressable low -profile photoelectric smoke detector. SD355T: Addressable low -profile photoelectric smoke detector with thermal sensor. SD355R: Remote test capable addressable photoelectric smoke detector for use with DNR(WW) duct detector housing. SD355CO: Addressable, low -profile device that provides fire, heat, and carbon monoxide (CO) detection. H355: Fast -response, low -profile heat detector. H355R: Fast -response, low -profile heat detector with rate -of -rise option. H355HT: Fast -response, low -profile heat detector that activates at 190°F/88°C. AD355: Low -profile, intelligent, "Adapt" multi -sensor detector (6350LP base included). B20OS: Programmable, addressable sounder base B200SR: Addressable sounder base. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitiv- ity test. D355PL: InnovairFlex low -flow non -relay duct -detector housing; includes SD355R. DNR: InnovairFlex low -flow non -relay duct -detector housing. (Order SD355R/SD365R separately.) DNRW: InnovairFlex low -flow non -relay duct -detector housing, with NEMA-4 rating. Watertight. (Order SD355R/SD365R separately.) Addressable Modules MMF-300: Addressable Monitor Module for one zone of normally - open dry -contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end -of -line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- vides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300. Addressable Monitor Module for one zone of conventional two -wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style Y/Z (Class B/ A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SM6500. BG-12LX: Addressable manual pull station with interface module mounted inside. 1300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). ISO-6: Six -fault isolator module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SMB500: Used to mount all modules except MMF-301 and M301. MMF-300-10: Ten -input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six -zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six -circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six -relay control module (Form-C relays). Mount one or two modules in a 1313-217 cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SWIFT Wireless Devices W-GATE: LiteSpeed Wireless Gateway WSD355: LiteSpeed intelligent, wireless photo detector. W-H355R: LiteSpeed intelligent wireless rate of rise (135") heat detector. W-SD355T: intelligent wireless photo/heat detector. W-H355: LiteSpeed intelligent wireless fixed -temperature (135°) heat detector. W-MMF: LiteSpeed Intelligent wireless monitor module. W-CRF: LiteSpeed Intelligent wireless relay module. W-BG12LX: LiteSpeed Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed IntelligentAV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE. For more information on Compatible Addressable Devices for use with the ES-50X, see the following data sheets (document num- bers): SD365 Series (DF-61010), H365 Series (DF-61011), AD355 (DF-52386), BG-12LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/CRF Series (DF-52130), CP355 (DF-52383), H355 Series (DF-52385), 1300 (DF-52389), ISO-6 (DF-60485), MMF-300 Series/MDF--300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), SD355ISD355T (DF-52384), and SLC Wiring Manual (51309). NOTE: Legacy 300 Series detection devices such as the CP300/CP350, SD300(7)ISD350(7) and older modules such as the M300, M301, M302, C304, and BG-10LX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard CLIP protocol. Please consult factory for further information on previous 300 Series devices. ADDRESSABLE DEVICE ACCESSORIES End -of -Line Resistor Assembly (R-47K and R-3.91K): The 47k ohm assembly supervises the MMF-300, MDF-300, MMF-301, and CMF-300 module circuits. The 3.9k ohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted -pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. DF-60953:C - 7/16/2018— Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity • Intelligent Signaling Line Circuits................................................1 • Addressable device capacity ....................................................50 • Programmable software zones.................................................50 • Annunciators.............................................................................16 Electrical Specifications AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, auto -sensing- no switch required. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead -acid batteries. Battery Charger Capacity: 7-18 AH (ES-50X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power -limited. Notification Appliance Circuits: Terminal Block provides connec- tions for two NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power -limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA regulated. End -of -Line Resistor: 4.7k ohm, % watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 kL2 - 22 kL2 ELR range. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non -power -limited, non -supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49•C/32 —120•F and at a relative humidity 93%u ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 27°C/60 — 80°F. NFPA Standards The ES-50X complies with the following NFPA 72 Fire Alarm Sys- tems requirements: — LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). — AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). — REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) — PROPRIETARY (Automatic, Manual and Waterflow). — CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). — OT, PSDN (Other Technologies, Packet -switched Data Net- work) — IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). — CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic ES-50X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL: S624 • FM approved • CSFM: 7165-0075:0500 • FDNY: COA #6261 NOTE. See DF-60954 for ULC-listed model. AlarmNet®, Fire-Lite® Alarms, SWIFT®, and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. @2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ' O 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. M1111EBI9C 8 M01111 fl61116 QUALITY SYSTEMS For more information, contact Fire•LiteAlarms. Phone: (800) 627-3473, FAX: (877) 6994105. Country of Origin: USA www.fiirelite.com Page 4 of 4 — DF-60953:C • 7/16/2018 B TELGUARD JkMETEK• TG-7FS LTE d COMMERCIAL FIRE CELLULAR ALARM C O M M U N I C A T O R FOR LTE NETWORKS PRODUCT FEATURES F° Certified for use on the AT&T or Verizon LTE networks for sunset -free installations. II- Meets UL 864 requirements for sole, primary or backup path communications. II- Minimizes false alarms by providing dual paths for self -tests. The Telguard TG-7FS LTE is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2019 and earlier editions of NFPA 72, the TG- 7FS LTE can serve as the sole communication path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE„ the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE because of the new five or sixty minute supervision modes. The TG-7FS LTE can also be installed as a backup path and upgraded to sole path at a later date. iFeatures the ability to iu'tilize mWtiple:cellular-te'chnologies,to iincrease 4a6ilability,and fredUce 4ais,e ra`larrns. . . Automaticaelf-fes'ts with<centra'I 'station ndt,ificatioh°ensure =the ;cellular system'is+,operatin.g. . Available rrelay routput foratripping the alarm con,trolpanel when. a , ,trouble condition' occurs. n e TELGUARD .kMETEIC TG-7FS LTE CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS ct( »> _ HerwErK {<� LTL 1 tllirr Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in -building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories TG-PEM: Power & Expansion Module for powering the TG-7FS from 24V DC alarm panel; no need to have an electrician install a dedicated outlet. • ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. • HGDL-0: High gain directional antenna. • EXDL-0: External antenna. UL Listings: AT&T and Verizon Commercial Fire Commercial Burglary Residential 864 • Control units & 365 Police Station 985 Household fire accessories for fire connected burglar warning systems alarm systems alarm units and 1023 • Household burglar systems alarm systems 1610 Central station burglar alarm units; Line security servcies ULC Listings: AT&T Only S545 Canadian household fire warning systems S304 Canadian commercial burglary alarm systems S559 Equipment for fire signal receiving centres and systems C1023 • Canadian household burglary alarm systems ' For the most current product specifications and ILL Listings visit www.Telguard.com. SECURITY SIGNALING cz' 1 � !��'`�',. IG \l� p��q`1, I1 "L �$ t�A I '�%�� X SECURIOY verizon/ : j � ASSOCIATION" network certified " NFPA' �/II\. Connected �+ LISTED �]k Ie91 INTERNATIONAL byAT&T 800.229.2326 13225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 • USA I telguard.com ©2020 Telguard is a brand of Telular Corporation I Telular is a business unit of AMETEK, Inc • All Rights Reserved DF-52417:D • B-90 ANN-80 80-Character Serial LCD Annunciator General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two -wire serial interface employ- ing the ANN-Bus communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. The ANN-80 is red; for white, orderANN-80-W. The ANN-80 displays English -language text of system point informa- tion including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-80s may be connected to the ANN-Bus of each FACP. No programming is required, which saves time during system commissioning. Features • Listed to UL Standard 864, 9th Edition • Backlit 80-character LCD display (20 characters x 4 lines) • Mimics all display information from the host panel • Control switches for System Acknowledge, Signal Silence, Drill, and Reset • Control switches can be independently enabled or disabled at the FACP • Keyswitch enables/disables control switches and mechanically locks annunciator enclosure • Keyswitch can be enabled or disabled at the FACP • Enclosure supervised for tamper • System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence • Local sounder can be enabled or disabled at the FACP • ANN-80 connects to the ANN-Bus terminal on the FACP and requires minimal panel programming • Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels • Time -and date display field • Surface mount directly to wall or to single, double, or 4" square electrical box • Semi -flush mount to single, double, or 4" square electrical box. Use ANN-SB80KITfor angled view mounting • Can be remotely located up to 6,000 feet (1,800 m) from the panel • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC) • Up to eight ANN-80s can be connected on the ANN-Bus Controls and Indicators • AC Power • Alarm • Trouble (a Flre•uTeraLarms by Honeywell • Supervisory • Alarm Silenced Specifications • Operating voltage range: 18 VDC to 28 VDC • Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum • Ambient temperature: 32°F to 120°F (0•C to 49°C) • Relative humidity: 93% ± 2% RH (non -condensing) at 32°C ± 2°C (90°F ± 3•F) • 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep • For use indoors in a dry location • All connections are power -limited and supervised The ANN-Bus POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- IARY POWER SUPPLY The ANN-Bus can be powered by an auxiliary power supply when the maximum number of ANN-Bus devices exceeds the ANN-Bus power requirements. See the FACP manual for more information. ANN-BUS DEVICE ADDRESSING Each ANN-Bus device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-Bus communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-Bus communications cir- cuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-Bus accessory modules, it is nec- essary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-Bus refer to appropriate FACP manual. DF-52417:D • 3/15/2018 — Page 1 of 2 WIRE REQUIREMENTS: POWER CIRCUIT • 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power circuit is acceptable. Power wire distance limitation is set by 1.2 volt maxi- mum line drop form source to end of circuit. • All connections are power -limited and supervised. • A maximum of eight ANN-80 modules may be connected to this circuit. Ordering Options ANN-80: Red 80 character LCD Annunciator. ANN-80-W: White, 80 character LCD Annunciator. ANN-SB80KIT-R: Red surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agen- cies, or listing may be in process. Consult factory for latest listing status. • UL: S2424 • FM approved • CSFM:7120-0075:0211 • MEA:442-06-E Fire -Late® Alarms is a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9oo1 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. BRIB 6iU A L I T B MANIFA EMS QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: 877 699-4105. ( ) Country of origin: USA www.firelite.com Page 2 of 2 — DF-52417:D • 3/15/2018 Standard Features: • 2 Key ring hooks to hold system keys • Business card holder for key contacts • Overall Dimensions are 12" x 13" tall and 2 % deep • 16 gauge steel box and cover for security • Durable powercoat baked on finish other colors available • Standard Wcat 30 key lock other lock as- semblies available • Solid stainless steel piano hinge • Permanently screened white ink 1" high "Fire Alarm Documents" • Legend sheet for passwords and system information �1-ma-w-r- r. n NFPA Made In U.S.A. FDB FIRE DOCUMENT BOX The FDB is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2010 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. Along with your fire alarm software you can store your test & inspection documents, service records, manuals & AS built drawings for the system. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. I50 9ppi R€GISTERED COMPANY , \ V ADA Space Age Electronics, Inc. 2013 ED0447 LT10505 Rev.B 1/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! SPACEAGE Wir ELECTRONICS, INC. Specifications: The fire alarm documents box (FDB) shall be constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS " with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Wi1EA Propertylnformation Minimum Required Documentation (SIG -FUN) aefear m�m..� nmu um.•�zn ae.ba umn.m.ymme.Krymn a uRm..• a u. mamn nedRilmnmpeprn ow. o­mnw rma— o WA o F.rcln•0 p M Laumn Certifications and Approvals 16.1 System Installation Contractor: mwemma•roMmwmea•um.•...mm�ea•meemem „w „e,.tew a•e. mane ma.lmm,.•w•d•.erown wrom.wroa.ro mnc.�mom.rxRwmmsw wa row. . s.m.ie m•oe.memxrormnwuewai..un>om.a.re� mow.. r..m.•a a .vt mrm. � a, ac.wmm 1Mr �cnvm Pam'+EYem.su44mtlN 4<i.Mn.rtlrzulmrum lmnuCen 16.6 Authority Havmp Jurisdkdon: o W. o FrtbW p .V. meramn ew. , �� �;; °�O'1OeOf mom .a mon mm•.w.w+'.2.aom rt•manmron..mraww•�•ooaw�M •mw• a w.,..m.e...c�.. �m� mmwm.aw.n sp.c .ca.o`wi.mmmwe.mM.wemsn.rw.R..m�a.a w>sa ow.. uae..a o. a a w.mrt m_ 10p 0 qK. tmi.vnia.�wmlae.maaf o rmmm�u, e'roi •°w ar u'i� �'a• Equipment Informationet•me. s.mtm • ut r•wmue•epemen, wmo wmawmmemmromu•ne rma•R.cusm•n r.e uwmrm,r.mra K .e.e.m. rc..nn r.� anw . eMmw a eiiiwm m l spampeFbmmm.lx 6BCIUYweaed sense. MAmsN eootedtrn w.r.r 1TIOW R.v.1 Legend sheet for storing system information including contacts, sign -off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SS000672 Fire Document Box RED SS000673 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0447 LT10505 Rev.B 2/2 D50 Series 50k4/o, 25k4lMode Surge Protective Device Genera/ Product Specifications DITEK's D50 industrial surge protectors are designed to provide protection to AC power systems in the most demanding environments. The D50 incorporates individually fused components for maximum performance and protection. Available in a wide range of voltage configurations, the compact D50 is an excellent choice for electrical panel protection. D50 Product Features • Suitable for use on branch panels and small disconnects • Compact size enables close mounting to the protected panel to minimize wire length and maximize performance • 50,000 Amp peak surge current capacity ensures long service life • Available in 8 voltage configurations • Diagnostic LED indicates system power and SPD function • Complies with ANSI/IEEE C62.41 and C62.45 Category B and C3 standards • Ten year limited warranty cf ZEUS '" �h Specifications Agency Approvals: UL 1449, 3rd Edition, cUL IEEE Location Category: Category B and C3 Protector Type: SPD Type 1 (US), Type 2 (Canada) Peak Surge Current: 50kA/Phase, 25kA/Mode Short Circuit Current Rating: 100,000A Protection Modes: See Chart Temperature Range: -40' —A40°F (-40° — 60°C) Maximum Humidity: 95% non -condensing Operating Frequency: 40Hz — 400Hz Housing: NEMA 4X Dimensions: 3.5"H x 3.5"W x 2.4"D (89mm x 89mm x 61 mm) Connection: %2' NPT conduit, watertight fittings Weight: 1.21b. (.5kg) Options: Flush Mount Kit, D50-FMK Dimensions: 5.0" x 5.0" Plate (127mm x 127mm) One DITEK Center 1-800-753-2345 Direct 1-727-812-5000 1720 Starkey Road Technical Support: 1-888-472-6100 Largo, FL 33771 www.ditekcorp.com ISD 900I-2000 I C @V$ Document: SPS-100073-001 Rev 2 09-11 ©2010 DITEK Corp. Specification Subject to Change D50 Series 50"10, 25"lMode Surge Protective Device Genera/ Product Specifications "..' "1Z' A D50 Surge Protection lndustgal Surge Protection Dimensions: Option Codes: Ordering Example: 3.5"H x 3.5"W x 2.4"D Flush Mount Kit: D50-120/2083Y: D50 for 50kA, (89mm x 89mm x 61 mm) D50-FMK 3 Wye for 4W+G, 120/208V system Outdoor Rated Conduit and Nipple Conduit fitting:''/" threaded NPT 350 Technical Specifications D50 Series Service MCOV UL 3.d UL 1449, 3rd Edition Voltage Protection Rating Wiring VZ Ed. 1„ Rating (VPR) L-N L-G N-G L-L D50-12012401 120/240VAC 150V/300V 20kA 600V 1000V 600V 1200V D50-120/24OHD Split 120/208VAC Three 0 150V/300V 20kA 600V 1000V 600V 1200V 50-120 2083 D50-12712203Y Wye D50-120/24OHL 120/240VAC Three 4) 150V/320V 10kA 600V/ 1000V 600V 1200V High Leg Delta HL 1200V HL-G 1500V HL-L 1500V D50-2401 240VAC SINGLE (V 320V 10KA 1200V 1200V 2000V N/A D50-240HW D50-277/4803Y 2771480VAC Three (P 320V/640V 10kA 1200V 2000V 1200V 2000V D50-22013803Y Wye D50-230/4003Y D50-24014153Y D50-34716003Y 347/600VAC Three 0 420/840V 1OKA 1500V 2500V 1500V 2500V Wye D50.2403D 240VAC Three 4) Delta 320V 10kA N/A 1200V N/A 2000V D50.4803D 480VAC Three (P Delta 550V 10kA N/A 1800V N/A 4000V One DITEK Center 1-800-753-2345 Direct 1-727-812-5000 1720 Starkey Road Technical Support: 1-888-472-6100 Largo, FL 33771 www.ditekcorp.com Ilso 9001-2000 1 C @US Document: SPS-100073-001 Rev 2 09-11 ©2010 DITEK Corp. Specification Subject to Change DF-61010:B SD365 Series Addressable Photoelectric Smoke Detectors The Fire-Lite® Alarms SD365(A), SD365R(A), and SD365HT(A) intelli-gent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the SD355 Series. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with Fire-Lite's addressable fire alarm control panels, the SD365(A) Series point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, provid- ing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious res- cue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The SD365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the SD365T(A) and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP: • Two -wire SLC loop connection • Unit uses base for wiring • Compatible with LiteSpeedTm and CLIP protocol systems • Stable communication technique with noise immunity ADDRESSING: • Addressable by device • Rotary, decimal addressing (Refer to the Fire-Lite panel manuals for device capacity.) ARCHITECTURE: • Sleek, low -profile, stylish design • Unique single -source design to respond quickly and dependably to a broad range of fires • Integral communications and built-in device -type identification • Built-in tamper resistant feature • Remote test feature from the panel • Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1(LiteSpeed systems only) • Built-in functional test switch activated by external magnet • Removable cover and insect -resistant screen for simple field cleaning • Expanded color options OPERATION: • Designed to meet UL 268 7th Edition • Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level • LED "blinks" when the unit is polled (communicating with the fire panel) and latches in alarm. • Low standby current rVIrxol:mr[alA&� • Sealed against back pressure • SEMS screws for wiring of the separate base • Designed for direct -surface or electrical -box mounting Fire•uTUaLarms by Honeywell. Plugs into separate base for ease of installation and maintenance Separate base allows interchange of photoelectric, ionization and thermal sensors OPTIONS: • Optional relay, isolator, and sounder bases Installation SD365 Series plug-in intelligent smoke detectors use a detachable base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. wring 7-taps" or branches are permitted for Style 4 (Class `B') wiring only. When using relay or sounder bases, consult the 1300(A) installation sheet 156-3626 for device limitations between isolator modules and iso- lator bases. Construction These detectors are constructed of fire-resistant plastic. The SD365 Series plug-in intelligent smoke detectors are designed to commer- cial standards and offer an attractive appearance. Operation Each SD365 Series detector uses one of the panel's addresses (total limit is panel dependent) on the Fire-Lite Signaling Line Circuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The SD365 Series offers features and performance that represent the latest in smoke detector technology. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an Fire-Lite addressable fire alarm control panel. The results of the sensitivity test can be printed for record keeping. DF-61010:B • 71/2019 — Page 1 of 3 Product Line Information NOTE. VV" suffix indicates CLIP and LiteSpeed device. NOTE. `A" suffix indicates Canadian version. SD365: White, low -profile intelligent photoelectric sensor, LiteSpeed SD365A: Same as SD365 but with ULC listing SD365-IV: Ivory, low -profile intelligent photoelectric sensor SD365A-IV: Same as SD3654V but with ULC listing SD365T: White, same as SD365 but includes a built-in 135°F (57°C) fixed -temperature thermal device, LiteSpeed only SD365TA: Same as SD365T but with ULC listing SD365T-IV: Ivory, same as SD365T but includes a built-in 135°F (57°C) fixed -temperature thermal device SD365TA-IV: Same as SD365T-IV but with ULC listing SD365R: White, low -profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW, LiteSpeed only SD365RA: Same as SD365R but with ULC listing, for use with DNRA SD365R-IV: Ivory, low -profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW SD365RA-IV: Same as SD365R-IV but with ULC listing, for use with DNRA INTELLIGENT BASES NOTE: For details on intelligent bases, see DF-60059. B300-6: White, 6" base, standard flanged low -profile mounting base (CSFM: 7300-1653: 0109) B300-6-IV: Ivory,6" base, standard flanged low -profile mounting base (CSFM: 7300-1653:0109) B300A-6: Same as B300-6, ULC listed B300A-6-IV: Ivory, 6" standard flanged low -profile mounting base, ULC listed B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UUULC listed (CSFM: 7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UUULC listed (CSFM: 7300-1653:0109) B501-IV: Ivory color, 4" standard European flangeless mounting base. UUULC listed (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of B501-WHITE contains 10 B224RB-WH: White, relay base (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base (CSFM: 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing B224RBA-IV: Ivory, relay base, ULC listing B224BI-WH: White, isolator detector base (CSFM: 7300-1653:0216) B224BI-IV: Ivory isolator detector base (CSFM: 7300-1653:0216) B224BIA-WH: White, isolator detector base, ULC listing B224BIA-IV: Ivory isolator detector base, ULC listing B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) Page 2 of 3 — DF-61010:B - 71/2019 H: Same as B200S-WH, ULC listing : Same as B200S-IV, ULC listing §ZOOSCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM. 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653.0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B210LP(A) base TR300-IV: Ivory, replacement flange for B210LP(A) base RAIOOZ(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single -gang electrical box. For use with B501(A) and B300-6(A). M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: Color Kit (includes cover and trim ring), white, 10-pack CK3004V: Color Kit (includes cover and trim ring), ivory, 10-pack CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack SYSTEM SPECIFICATIONS Sensitivity: • ULApplications: 0.5% to 4.0% per foot obscuration. • ULC Applications: 0.5% to 3.5% per foot obscu ration Size: 2.0" (5.3 cm) high; base determines diameter — B300-6: 6.1" (15.6 cm) diameter — B501: 4" (10.2 cm) diameter For a complete list of detector bases see DF-60983 Shipping weight: 3.4 oz. (95 g) Operating temperature range: • SD365: 32°F to 122°F (0•C to 50°C) • SD365T Series: 32•F to 100•F(0°C to 38°C) • SD365R Series installed in a DNR/DNRW, -4•F to 158•F (-20•C to 70°C) UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10% — 93% non -condensing Thermal ratings: fixed -temperature set point 135°F (57°C), rate -of - rise detection 15•F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (one communica- tion every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC ("ON") DETECTOR SPACING AND APPLICATIONS Fire-Lite recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space defectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document A05-1003, is avail- able at www.systemsensor.com. Listings and Approvals Listings and approvals below apply to the SD365 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listing: S1059 FM Approved CSFM: 7272-0075:0502 LiteSpeedTm is a trademark, and Fire-Lite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2019 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 1S0 9oo1 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Uii11YU111N0 6 MMIFlICIL91N6 QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800)627-3473,FAX: (877)699-4105. Country of Origin: Mexico www.firelite.com Page 3 of 3 — DF-61010:B • 71/2019 DF-52013:D • E-100 BG-12LX Addressable Manual Pull Station General The Fire-Lite BG-12LX is a state-of-the-art, dual -action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and - address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire -ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-1/0) or semi - flush mounted. Semi -flush mount to a standard single - gang, double -gang, or 4" (10.16 cm) square electrical box. • Smooth dual -action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications • Shipping Weight: 9.6 oz. (272.15 g) • Normal operating voltage: 24 VDC. • Maximum SLC loop voltage: 28.0 VDC. • Maximum SLC standby current: 375 NA. • Maximum SLC alarm current: 5 mA. • Temperature Range: 320F to 120°F (0°C to 49°C) • Relative Humidity: 10% to 93% (noncondensing) • For use indoors in a dry location Installation The BG-12LX will mount semi -flush into a single -gang, double - gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-1/0 surface back - box. If the BG-12LX is being semi -flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is 8 Fire•IJTUALarms by Honeywell usually needed for semi -flush mounting with 4" (10.16 cm) or double -gang boxes (not with single -gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 —159 with Breakaway Tab removed for MS-9600 Series, 1 — 99 and MS-92000DLS, 1 — 50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non -coded, with a key - operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red -colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-1/0; or semi -flush mounting on a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box, and shall be installed DF-520130 • 4/13/2012 — Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual -action addressable pull station. Includes key locking feature. (Listed for Canadian and non -Canadian appli- cations.) SB-10: Surface backbox; metal. SB-1/0: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL/ULC Listed: S711 (listed for Canadian and non -Cana- dian applications). • MEA:67-02-E. • CSFM:7150-0075:0184. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. FireLite® Alarms® is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENSIM1111INS 8 MANIfAMM IS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 — DF-520130 • 4/13/2012 MMF-300(A) Series, MDF-300 :1, Addressable Monitor Modules General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry -contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two -wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard -sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry -contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that super- vises a Style B (Class B) circuit of dry -contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single -gang box behind the device it monitors. MMF-302(A) is a standard -sized module used to monitor and supervise compatible two -wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard -sized dual monitor module used to monitor and supervise two independent two -wire Style B (Class B) dry -contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two -wire sys- tems. LiteSpeedTm is a communication protocol developed by Fire-Lite Engineering that greatly increases the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. MMF-300(A) Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the control panel. • Powered directly by two -wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct -dial entry of address: 01 — 159 on MS-9600 series panels, 01 — 99 on other compatible systems. • LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two -wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two -wire or four -wire fault -tolerant Initiating Device Circuit (IDC) for normally -open -contact fire alarm and supervisory devices. The module has a panel -controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPucAnws Use to monitor a zone of four -wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally - open dry -contact alarm activation devices. May also be used to monitor normally -open supervisory devices with special DF-52121:E • E-325 Flrelffe®ALarms by Honeywell n suryn♦jq ue ry,n MMF-300(A) (Type H) supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End -of -Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPErzarioa Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIF/unws Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-301(A) Mini Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the panel. • Powered directly by two -wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. DF-52121:E • 07/30/2015 — Page 1 of 4 • Tinned, stripped leads for ease of wiring. • Direct -dial entry of address: 01 — 159 on MS-9600 series panels, 01 — 99 on other compatible systems A 1415 0 1 ADDRESS 0 1 13 2 � 2 11 O 4 LOOP O 4 109 8 7 65 � 9 8 7 65 TENS ONES OLu m The MMF-301(A) Mini Monitor Module can be installed in a single -gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two -wire systems where the individual address of each module is selected using rotary switches. It provides a two -wire initiat- ing device circuit for normally -open -contact fire alarm devices. The MMF-301(A) can be used to replace M301(A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four -wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally -open dry -contact devices. May also be used to monitor normally -open supervisory devices with special supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End -of -Line Resistor (provided) terminates the circuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 NA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 NA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0•C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65' (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF.302(A) Interface Module • Supports compatible two -wire smoke detectors. Page 2 of 4 — DF-52121:E • 07/30/2015 • Supervises IDC wiring and connection of external power source. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct -dial entry entry of address: 01 — 159 on MS-9600 series panels, 01 — 99 on other compatible systems. • LED flashes during normal operation. • LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two - wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two -wire detectors being monitored must be UL compatible with the module. The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two -wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K Ohm End -of -Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals T10 and T11): • DC voltage: 24 volts power limited. • Ripple voltage: 0.1 Vrms maximum. • Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0•C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF.300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two -wire systems. It provides two independent two - wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel - controlled LED. NOTE. The MDF-300(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32• to 120°F (0• to 49•C). Humidity range: 10% to 93% (non -condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE. "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface -mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power -limited wiring only. The MMF-301(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S2424. • ULC: S2424. • FM Approved. • CSFM:7300-0075:0185. • MEA:72-01-E. Product Line Informatio NOTE: A" suffix indicates ULC-li model. Monitor mo u e MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two -wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface -mount backbox. NOTE. See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects'/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. DF-52121:E • 07/30/2015 — Page 3 of 4 Fire-Lite® is a registered trademark and LiteSpeedTM and FireWatchTA/ are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 'SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MCIN®INC A MRMMIIINB QUALITY SYSTEMS All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4 — DF-52121:E • 07/30/2015 df-60379:A1 • E-400 CRF-300(A) Relay Module General The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry -contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Ad&essability allows the dry contact to be activated through panel programming, on a select basis. LlteSpeedTm is a communication protocol developed by Fire•Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features • Built-in type identification automatically identifies these devices to the control panel. • Internal circuitry and relay powered directly by two -wire SLC loop. • Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. • High noise immunity (EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. • Direct -dial entry of address: 01— 159 for MS-9600(A) series panels, 01 — 99 on MS-92000DLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four -wire smoke detector power. Construction • The face plate is made of off-white heat -resistant plastic. • Controls include two rotary switches for direct -dial entry of address setting. • The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. • The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. (a Flre•LITe®ALarms by Honeywell �.. <�> 141 <Po t "e]" CRF-300(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 320F to 120OF (0°C to 490C). Humidity range: 10% to 93% non -condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.396 mm) deep box. Relay Contact Ratings Load Description Application Maximum Voltage Current Rating Resistive Non -Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non -Coded 110 VDC 0.9 A Resistive Non -Coded 125 VAC 0.9 A Inductive (UR=5ms) Coded 30 VDC 0.5 A Inductive (UR=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non -Coded 125 VAC 0.5 A df-60379:A1 •08/04/09 — Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S2424 • ULC: S2424 • FM approved • CSFM: 7300-0075:185 • MEA:72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. : Intelligent addressable relay module, ULC listed model. SMB500: Optional surface -mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual, document 51309. LiteSpeedTM is a trademark and Fire•Lite® Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I� O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENRIN1111N0 8 MANEM1110 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 — df-60379:A1 •08/04/09 DF-60430:C2 • E-650 D355PL(A)/DNRW InnovairFlex Intelligent Non -Relay Photoelectric Duct Smoke Detector General The Fire•Lite InnovairFlex® D355PL(A) intelligent non -relay photoelectric duct smoke detector and DNRW watertight non - relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capa- ble of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute (0.5 to 20.32 m/s), temperatures of -4°F to 158°F (-20°C to 700C), and a humidity range of 0 to 95 percent (non -condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sensor cover. The Fire•Lite InnovairFlex housing provides a 3/ 4-inch conduit knockout and ample space to facilitate easy wir- ing and mounting of a relay module. The Fire•Lite InnovairFlex duct smoke detector can be custom- ized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. Features • Photoelectric, integrated low -flow technology. • Air velocity rating from 100 ft/min to 4,000 fl/min (0.5 m/s to 20.32 m/s). • Versatile mounting options: square or rectangular configu- ration. • Broad ranges for operating temperature (-4°F to 158°F, - 20°C to 70°C) and humidity (0% to 95% non -condensing). • Patented sampling tube installs from front or back of the detector with no tools required. • Cover tamper signal. • Increased wiring space with a newly added 3/4" conduit knockout. • Available space within housing to accommodate mounting of a relay module. • Easily accessible code wheels on sensor head (sold sepa- rately). • Clear cover for convenient visual inspection. • Remote testing capability. • Requires com line power only. • Accommodates the installation of an addressable relay module, sold separately, (CRF-300) for applications requir- ing a Form-C relay. (a Fire-LITUALarms by Honeywell Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth. Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth. Weight: 1.6 lb (0.73 kg). Operating Temperature Range: -4°F to 158OF (-20°C to 70°C). Storage Temperature Range: -22°F to 158°F (-30oC to 70°C). Operating Humidity Range: 0% to 95% relative humidity (non -condensing). Air Duct Velocity: 100 to 4,000 ft/min (0.5 to 20.32 m/s). Accessories Fire•Lite provides system flexibility with a variety of accesso- ries, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. D355PLs and DNRWs with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote -test -capable detector. ACCESSORY CURRENT LOADS AT 24 VDC Device Standby Alarm RA100Z OmA 12 mA Max RTS151/ OmA 12mA Max RTS151KEY Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. • UL: S1059. • ULC: S1059 DF-60430:C2.12/18/2012 — Page 1 of 2 • CSFM: 3242-1653:0209. • FM approved. Product Line Information D355PL: Intelligent non -relay photoelectric low flow smoke detector housing. Includes SD355R Detector. DNRW: Watertight intelligent non -relay photoelectric low flow duct smoke detector housing. Does not include detector head. SD355R(A): Remote test capable addressable low -profile photoelectric smoke detector. SD355(A): Addressable low -profile photoelectric smoke detec- tor. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1: Metal sampling tube duct width up to 1 ft (0.3m). DST1.5: Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m). DST3: Metal sampling tube duct widths up to 2 ft to 4 ft (0.6 to 1.2 m). DSTS: Metal sampling tube duct widths up to 4 ft to 8 ft (1.2 to 2.4 m). DST10: Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m). DH4000E-1: Weatherproof enclosure. ETX: Metal exhaust tube duct, width 1 ft (0.3 m). M02-04-00: Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z: Remote annunciator alarm LED. RTS151: Remote test station. RTS151 KEY: Remote test station with key lock. Important Note • DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. • DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. Fire•Lite® Alarms is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 9YCIM B N1 A MANIfAMIHN6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 — DF-60430:C2.12/18/2012 SYSTEM SENSORm Duct Smoke Detector Accessories Expand the versatility of the InnovairFlexM line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories APA151 Piezo Annunciator MHR Mini -Horn, Red MHW Mini -Horn, White RA100Z/RA100ZA Remote Annunciator RTS151 Remote Test Station RTS151KEY Remote Test Station with Key RTS2 Multi -Signaling Accessory AOS Add -On Strobe RTS2-AOS Multi -Signaling Accessory Agency Listings FM 73o0-1 ss3:o212 C E LISTED APPROVED 7300-1653:0211 52522 3034401 7135-1653:0196 9080301 Duct smoke detector accessories add functionality to the duct smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. The APA151 piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A. The MHR and MHW SpectrAlert® Advance mini -horns feature temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single -gang back boxes for applications where a small device is desired. The RA100Z, and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The RTS151 and RTS151 KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151 KEY test station features a multi -colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. The RTS2 and RTS2•AOS multi -signaling accessories are designed to work with InnovairFlex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add -On Strobe) is an optional accessory included with the RTS2- AOS model. Specifications, Duct Smoke Detector Accessories Voltage Regulated 24 VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 0°C to 49°C (32°F to 120°F) Relative Humidity 10 to 93% non -condensing Wire Gauge 12 to 18 AWG Dimensions Voltage 4.6"H x 2.9"W x .45"D Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or FWR Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC 29 mA RMS max. at 16 to 33 Volts DC Temperature Range 0°C to 490C (320F to 120°F) Humidity Range 10 to 93% non -condensing Nominal Sounder Frequency 3 kHz Wire Gauge 12 to 18 AWG Dimensions 4.6"H x 2.9"W x 0.45"D Voltage Range Conventional System: 3.1 to 32 VDC Intelligent System: 18 to 32 VDC Maximum Alarm Current 10 mA Dimensions 4.6 "H x 2.8"W x 1.3"D RTS151 UL S4011 RTS151 KEY UL S2522 y C RA10OZ UL S2522 MHW UL S4011 Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Test Switch 10 VA @ 32 VDC Reset Switch 10 VA @ 32 VDC Alarm Response Time 40 seconds max. Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non -condensing Wire Gauge 14 to 18 AWG Dimensions 4.8"H x 2.90"W x 1.4"D RTS1 51 KEY Remote Test Power Requirements Station with Key Power LED (Green): 14 to 35 VDC, 12 mA max. Alarm LED (Red): 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Alarm Response Time 40 seconds max. Temperature Range —10°C to 60oC (14°F to 140°F) Relative Humidity 95% non -condensing Wire Gauge 14 to 18 AWG Dimensions 4.6"H x 2.75"W x 1.8"D RTS2 and RTS2-AOS Multi Voltage -signaling Accessory 20 to 29 VDC Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non -condensing Wire Gauge 14 to 22 AWG Dimensions 4.8"W x 5.3"H x 1.6" D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com fi SMOKE -� o, APA151 UL S4011 RTS2-AOS UL S2522 hr"'•Z ( . o , MHR UL S4011 AOS SYSTE'r, 3825 Ohio Avenue • St. Charles, IL 60174 02013 System Sensor. A, Kp Phone: 800 SENSOR2 • FaX: 630-377-6495 Product specifications subject to change without notice. Visit systemsensoccom SENSOR' ! ' for current product information, including the latest version of this data sheet www.systemsensor.com HVDS20202. 8/13 SYSTEM SENSOR' Indoor Selectable - Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only Aaencv Listinas SIGNALING U` F M �; LISTED APPROVED 55512 FM approved except 7125-1653:0504 $4011 for ALERT models 7135-1653.0503 3057383 � r • The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVOS868-02. 12/0112017 • Page 3 L-Series Specifications General L-Series ceiling -mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double - gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit'' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120OF (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling -Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02. 12/01I2017 • Page 2 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 87 41 60 Range 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded Hiah 42 43 54 DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non -Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non -Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non -Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non -Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1K Non -Temporal High 108 135 179 200 225 255 289 3.1 K Non -Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data iMorn Switch Position .. .: Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 L-Series Dimensions 6.83° di (173 rr 2.47' (62.7 mm) 1.37' (34.8 mm) Ceiling -Mount Horn Strobes 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box A0545.00 -01 L-Series Ordering Information Model Description 7 Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red e, riorn STrobe, f PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White For a ceiling -listed horn -only device, see AVDS865 "Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications". 6.92° rli— (175. Ceiling Surface Mount Back Box 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box DescriptionModel Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceilino Trim Rino Red 2.5' (64 mm) O TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White A0546-00 -01 "STEM /I m207 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject lot change without notice. Visit systemsensor.com _4 SENSOR' Phone: 800-SENSOR2 • Fax: 630-377-6495 or currenlp product infonAVDS,including g-1211/201 version of this data sheet. AVDS666-02. 12I01/2017