HomeMy WebLinkAboutApplication Engineering for Heating & CoolingAPPLICATION ENGINEERING FOR HEATING AND COOLING JACOBSEN HOMES 901 4th St North Safety Harbor, FL 34695 /0 7-13-18 =` � N Manufacturer's Model #: MCP-3037-M1426 CqR ER P" HVAC System Type: OVERHEAD GRAD FLEX FOR UP -FLOW (SPLIT A/C) Prepared By LaSalle Air Systems 71512018 (Method & Output 20181 All rights reserved: this information proprietary to LaSalle Bristol Co. and JACOBSEN HOMES Calculations on this page are based on design standards set forth in ASHR4E and ACCA Manuals J Rev 8.2 and D Rev 1.1. System registers are located for best distribution based on Manual T. Design calculations are based on ACTUAL orientation. Room loads may vary based on actual conditions. ENTIRE HOUSE VALUES - DESIGN ZONE: FL, Region 2A FBC (2017)/IECC (2015) 30N Latitude COOLING LOAD: 19,716 Btuh for Outside Temp/Humidity of 96 ° F ( 35 C)/ 48% and Inside reduced to 75 ° F (23 C)/ 50% HEATING LOAD: 18,066 Stuh based on outside temp of 17 ° F ( -9 C) with inside temp raised to 72 ° F (22 C) Crawlspace is not heated by the primary air handler. Actual UA =181.7 Max UA (Table R402.1.2) = 229.4 Use net wall area, not gross wall CONSTRUCTION DETAILS & U / SHGC VALUES: (22+Non-ins Rim -19 - 30) GREEN ORIENTATION Total Cond. Floor Area: 862.00 s.f. TRUE Outside Perimeter: 135.00 ft Level 1 Ceiling: 108 to 108 in. Level 2 Ceiling: 0 to 0 in. Level 3 Ceiling: 0 to 0 in. Net Roof Area (less ducts): 785.7 s.f. Primary Wall Area: 1072.46 s.f. (Net) Dark Roof(U): 0.032 FLOOR DUCTS (U): n/a Duct TEL Secondary Wall Area: 0.00 s.f. (Net) Prim Wall (U): 0.059 ATTIC DUCTS (U): 0.125 363.2 ft TOTAL Low-E window 120.83 s.f. Sec Wall (U): 0.030 EXT. DUCTS (U): 0.125 TOTAL S.G.D. 0.00 s.f. Exp Floor(U): 0.044 INFLOOR DUCT AREA: 0 S.F. @ 51 TD/ 29.8 TD TOTAL Glass Block 0.00 s.f. Low-E wi 0.350 / 0.28 ATTIC DUCT AREA: 89.372 S.F. @ 95 TD/ 94.1 TD TOTAL Skylite 0.00 s.f. S.G.D. 0.480 / 0.39 EXT. DUCT AREA: 0 S.F. @ 95 TD/ 49 TD TOTAL Doorl Area: 21.70 s.f. Glass Blc 0.630 / 0.51 PEOPLE: 3 3421.3 Btuh Total Appliances TOTAL Door2 Area: 0.00 s.f. Skylite 0.790 / 0.64 FIREPLACES: 0 All Glass % of Floor: 14.02 % Door 1: OA60 DUCT GAIN: @ Semi -Tight 1102 Btuh All Glass % of Wall: 9.95 % Door 2: 0.670 DUCT LOSS: 1194 Btuh LATENT GAIN: 4405 Btuh Summer Infiltr (7.5 mph): 28.1 cfm Mech. Ventilation : 63.12 cfn ( 29.8 L/s) Altitude: 40 ft Winter Infiltration (15 mph): 52.9 cfm @ Semi -Tight ROOM BY ROOM VALUES: 585.3 FPM, max velocity in trunk#: 2 Heat Exiting Furnace: 96 deg A/C Exiting : 50 deg 0.13 Max pressure at A/H NOTICE: Due to glass area variations, the hourly cooling Cooling Air Heating Air loads may not be balanced by a single -zone system Values for Values for 30 7.5 KW Maximum A/C capacity HEATING COOLING CFM 2 ton unit 90 % Gas/Oil Elec Calibrated Blower Test ROOM NAME LOSS (Btu) GAIN (Btu) DIST CFM Btuh CFM Btuh E Btuh Btuh (sit adj) Living Room c 4,668 5,118 179 199 5,704 192 6,476 6,137 9,315 Bath#2 h 1,119 986 35 48 1,376 46 1,562 1,481 2,249 M. Bedroom c 3,368 3,522 126 147 4,224 142 4,795 4,545 6,874 Bedroom #2 c 2,714 2,929 104 129 3,689 124 4,188 3,970 6,004 Bath #1 c 943 984 34 46 1,306 44 1,483 1,406 2,136 Kitchen c 1,885 2,113 75 84 2,417 81 2,744 2,601 3,948 Dining c 3,370 4,063 144 175 5,031 169 5,712 5,414 8,139 TOTALS 18,066 19,716 698 828 23,747 798 26,960 25,552 38,665 APPLICATION ENGINEERING DUCT AIR FLOW AND SIZING WORKSHEET (MANUAL D) Manufacturer: JACOBSEN HOMES Model #: MCP-3037-M1426 901 4th St North HVAC System Type: OVERHEAD GRAD FLEX FOR UP -FLOW (SPLIT A/C) Safety Harbor, FL 34695 Design Zone: FL, Region 2A FBC (2017)/IECC (2015) Prepared by LaSalle Air Systems 7/5/2018 All rights reserved. This information proprietary to LaSalle Bristol Co. and JACOBSEN HOMES Calculations include factors for duct air temperature change and pressure drops through ducts. All joints are tightly fitted or sealed. Blower CFM 696 @ 0.7 E.S.P. TEL= 413.2055 FR= 0.0944 (A/C Coil included) Altitude = 40 ft User Input BRANCH DUCT LISTING ANALYSIS Elec (Altitude Adj.) Final I Final BR Trunk Metal F. G. Flex Bends/ Total Eq. Heat Cool Heat Cool Design Round Rectangle Size Round Velocity # # (ft) (ft) (ft) Fittings(ft) Length Btuh Btuh cfm cfm cfm Size (W.) x (i.d.) Size fpm 1 M. Bedroom 2 0 4 20 230.4 254.4 3,368 3,522 114 124 124 5.83 7.0 463.5 2 Bath#2 2 0 4 17 322.6 343.6 1,119 986 38 35 38 4.10 5.0 276.8 3 Living Room 2 0 4 11 227.7 242.7 2,371 2,600 80 91 91 5.18 6.0 465.7 4 Living Room 2 0 4 20 230.4 254.4 2,296 2,518 77 89 89 5.18 6.0 450.9 5 Bedroom #2 3 0 .4 13 285.8 302.8 2,714 2,929 92 103 103 5.74 7.0 385.4 6 Bath #1 3 0 4 16 343.2 363.2 943 984 32 35 35 4.04 5.0 253.8 7 Kitchen 3 0 4 17 287 308.0 1,885 2,113 64 74 74 5.15 6.0 378.4 8 Dining 3 0 4 27 290 321.0 3,370 4,063 114 143 143 6.74 8.0 409.3 N/A Other Rooms - - TRUNK DUCT LISTING ANALYSIS TRUNK# 1 TRUNK# 2 TRUNK# 3 TRUNK # 4 TRUNK # 5 TRUNK# 6 TRUNK# 7 TRUNK# 8 TRUNK # 9 TRUNK# 10 TRUNK# 11 TRUNK# 12 TRUNK # 13 TRUNK # 14 TRUNK# 15 LONGEST RETURN DUCT 18,066 19,716 609 693 696 "0 7-13-18 =� � (A ti 4 90 94.0 18,066 19,716 696 9.72 14.0 651.4 4 94 98.0 18,066 19,716 696 9.76 13 17 16.2 453.8 5 194.851 199.9 8,912 10,089 355 8.38 12.0 451.7 - 0 0 0 0 0 0 _ 0 0 0 0 0 0 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7 0 50 50 696 9.30 19 19 20.8 277.8 APPLICATION ENGINEERING EQUIPMENT SELECTION AND SIZING WORKSHEET (MANUAL S) Manufacturer: JACOBSEN HOMES Model #: MCP-3037-M1426 901 4th St North HVAC System Type: OVERHEAD GRAD FLEX FOR UP -FLOW (SPLIT A/C) Safety Harbor, FL 34695 Design Zone: FL, Region 2A FBC (2017)/IECC (2015) Prepared by LaSalle Air Systems 71512018 All rights reserved. This information proprietary to LaSalle Bristol Co. and JACOBSEN HOMES RESULTS FROM MANUAL J CALCULATIONS: Actual Orientation HEATING LOAD: 18,066 Btuh at 17 RECI'D BLOWER CFM: 828 cfm at altitude of 40 ft SENSIBLE CLG LOAD: 15,311 Btuh at 96 Entering Air DRY Bulb: 76.9 Mech. Ventilation : 63 LATENT CLG LOAD: 4,405 Btuh at 96 Entering Air WET Bulb: 61.5 Entering Air RH: 53 GRAINS DIFFERENCE: 60 Outsidewetbulb: 74.7 ° outsideRH: 47.9 FILL IN BLANKS IN EACH SECTION FROM THE H.V.A.C. EQUIPMENT DATA CHARTS: (Do not use ARI Ratings!) Air handler model #: Condenser model M Blower Data Select blower speed in COOLING mode: Blower CFM is between 592 > < 801 for Total (External) Static Pressure between 0.6> <0.8 =Electric, Gas or Oil Furnace Select blower speed in HEATING mode: Output Btuh is between 18969> <25292 Blower CFM is between 316 > < 373 for Temp. rise of 55-65 Blower CFM is between 373 > < 456 for Temp. rise of 45-55 PpPROVEO Blower CFM is between 456 > < 587 for Temp. rise of 35-45 \� o y Cooling Equipment S/T Ratio = 0.77 Leaving Temp = 50.1 ° TD = 24.9 O 7 -13 -18 At 96F outside, Total A/C output from 20109 btuh to 22673 btuh is GOOD. z w At 96F outside, Total A/C output from 22673 btuh to 23658 btuh is MARGINAL. V'r Sensible Capacity is from 13108 btuh to 17513 btuh �F,Q NCO Latent Capacity is from 4316 btuh to 6607 btuh CARTER g P Mechanical Ventilation is 9 % of blower cfm. Dry bulb increases by: 1.9 ° Wet bulb increases by: 1 ° Heat Pump with Supplemental Heating Coils Data from performace charts Data from load calculation btuh at F outside 0 btuh at 72 F outside btuh at _ F outside 18,066 btuh at 17 F outside 25000 lr�raw Loa J Line and Perform 3nce Line z0000 I i 15000 -711 10000 I k i 5000 I 0 10 19.2 28.5 37.8 47.1 56.4 65.7 75 At winter design temperature of 17 F outside, the distance between the lines is btuh which is the Supplemental Heat divided by 3400 = KW. APPLICATION ENGINEERING INTERNATIONAL MECHANICAL CODE - Chapter 4 Ventilation Worsheei Manufacturer: JACOBSEN HOMES Model #: MCP-3037-M1426 901 4th St North HVAC System Type: OVERHEAD GRAD FLEX FOR UP -FLOW (SPLIT A/C) Safety Harbor, FL 34695 Design Zone: FL, Region 2A FBC (2017)/IECC (2015) Prepared by LaSalle Air Systems 7/5/2018 All rights reserved. This information proprietary to LaSalle Bristol Co. and JACOBSEN HOMES RESULTS FROM MANUAL-J CALCULATIONS: Actual Orientation HEATING LOAD: 18,066 Btuh at 17 ° REQ'D BLOWER CFM: 828 cfm at altitude of 40 ft SENSIBLE CLG LOAD: 15,311 Btuh at 96 ° Entering Air DRY Bulb: 76.9 ° Mech. Ventilation : 63 LATENT CLG LOAD: 4,405 Btuh at 96 ° Entering Air WET Bulb: 61.5 ° Entering Air RH: 53 % GRAINS DIFFERENCE: 60 Outside wet bulb: 74.7 outside RH: 48 % Natural or Mechanical: Test the infiltration at 50 Pa should result in 570.2 CFM infiltration being 4.410 ACH (to be confirmed by testing) (5 ACH = 646 CFM) (3 ACH = 387 CFM) Mechanical ventilation is required To Meet Natural Ventilation: Increase Openable Area by 13 % Openable Area Openable Area ROOM NAME Room Area Required Built ROOM NAME Room Area Require Built Living Room 194.0 7.7 18.75 0.0 0.0 0.00 Bath #2 94.0 3.7 0.00 0.0 0.0 0.00 M. Bedroom 174.0 6.9 7.50 0.0 0.0 0.00 Bedroom #2 134.2 5.3 7.50 0.0 0.0 0.00 Bath #1 54:2 2.1 1.25 0.0 0.0 0.00 Kitchen 111.7 4.4 4.17 0.0 0.0 0.00 Dining 100.0 ' 4.0 21.25 0.0 0.0 0.00 0.0 0.0 0.00 0.0 _ 0.0 0.00 _ 0.0 0.0 0.00 0.0 0.0 0.00 TOTAL 862.0 34.1 60.42 Mechanical Ventilation Is Required In These Areas To Meet IMC 2012i2015 Per Table 403.3.1.1: Outdoor Exhaust SPACE CLASSIFICATIONS Occupancy Area Air Air ZONE AIR DISTRIBUTION Private Living Area Private Kitchen Private Baths Total 3.0 602.2 63.1 0.0 111.7 0.0 0.0 148.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3.0 862.0 63.1 25.0 40.0 0.0 0.0 0.0 65.0 7-13-18 ? M C1 R Floor Supply of Warm Air/Floor Return Floor Supply of Warm Air/Floor Return Floor Supply of Warm Air/Floor Return Air Flow 650.2 84.3 93.55 0 0 0 828 System Ventitlation Efficiency: F1 6 351gNulp b MW 7H is WALL lowftlGN J, h BEDROOM #2 6TUIM 6:0r V 9d 30 �(a tee 4ff-R-W *1 2X6, x Fi 5 .8X4, rHIGH 7 SIDE T\76 8 I zr I tw Zo 7 Alp - 72X6. X I 30 N M I : 1 i V A 7; 7]FIT MASTER BEDROOM 11 119 GREEN G un p IX� C-3 I/V L 14 RISER Manufacturing maSalleBristol a n ufactu ri n 9 Engineered System Using Overhead Graduated Flex Ducts w/ Ceiling Diffusers for Up -Flow Split A/C ON —FRAME (2x8) —40'-Cr ri W-0, 24 Ig X 60 lEf I I X 40114! gild ===JjPrE FOTR� I DPM rI---- -- SIP DINING 6 i 2X6 11 2X0- i '14 1 (D Eli, l6 0l1-71 1 8 301 fm 314V 22\ 60 4 6 W. 6. iM OX LIVING VIC z 821/14r fu FW X 00 11t4! 6--2- AAQ252L HDMM .. .... ..... . C Malazu�4= 7-13-18 M alw(a w TER V-t It