HomeMy WebLinkAboutInspection ChecklistCREScheck Software Version 4.6.5
�(J Inspection Checklist
Energy Code: 2017 Florida Building Code, Energy Conservation
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
#
'Pre-Inspection%Plan ReviewComplies?
PlansValue
FielV Verified
Value
Comments/Assumptions
& ,Req.ID.
° m
103.1,
Construction drawings and
❑Complies
103.2
documentation demonstrate
❑Does Not
[PR111
energy code compliance for the
❑Not Observable
lopbuilding
envelope. Thermal
envelope represented on
❑Not Applicable
construction documents.
103.1,
Construction drawings and
❑Complies
103.2,
documentation demonstrate
F ° :'
❑Does Not
403.7,
energy code compliance for
;
❑Not Observable
'
403.8
[PR3]1
lighting and mechanical systems
Systems serving multiple
❑Not Applicable
(Qt
dwelling units must demonstrate
zJ:
compliance with the IECC
Commercial Provisions.n
302.1,
Heating and cooling equipment is
Heating:
Heating:
❑Complies
403.7
sized per ACCA Manual S based
Btu/hr
Btu/hr
❑Does Not
[PR2]2
on loads calculated per ACCA
Cooling:
Cooling:
❑Not Observable
j n
Manual J or other methods
approved by the code official.
Btu/hr
Btu/hr
❑Not Applicable
302.1,°
Heating and cooling equipment is
Heating:
Heating:
❑Complies
403.7
sized per ACCA Manual S based
Btu/hr
Btu/hr
❑Does Not
[PR2]2
on loads calculated per ACCA
Cooling:
Cooling:
❑Not Observable
Manual J or other methods
_
Btu/hr
Btu/hr
❑Not Applicable
approved by the code official.
Refer to R403.7.1 for full details.
Additional Comments/Assumptions:
111 High Impact (Tier 1) 2I Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: M-1426 Report date: 07/09/18
Data filename: W:\online.ntainc.com\050918-54\Project Documents\1426 RESCHECK.rck Page 2 of 9
Section
#
& Req.l�
Foundation Inspect'onr
_°...
Complies? =
Comments/Assumption`s,
303.2.1.3;
A protective covering is installed to
❑Complies
[FO11]2�:,
protect exposed exterior insulation
❑Does Not ,
° ,
and extends a minimum of 6 in. below
❑Not Observable
grade.
❑Not Applicable
403.9': : ',
Snow- and ice -melting system controls
❑Complies
[FO12]2a1a
installed.
❑Does Not
[]Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact (Tier 1) =2, Medium Impact (Tier2) 3 Low Impact (Tier 3)
Project Title: M-1426 Report date: 07/09/18
Data filename: W:\online.ntainc.com\050918-54\Project Documents\1426 RESCHECK.rck Page 3 of 9
Section
#
Framing / Rough -In Inspection
Plans. Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.ID
303.1.3
U-factors of fenestration products
❑Complies
[FR4]1
are determined in accordance
❑Does Not
00
with the NFRC test procedure or
taken from the default table.
❑Not Observable
❑Not Applicable
402.1.1,
Glazing U-factor (area -weighted
U-
U-
❑Complies
See the Envelope Assemblies
402.3.1,
average).
-
❑Does Not
table for values.
402.3.3,
503.1.1.1
❑Not Observable
[FR2]1
❑Not Applicable
402.1.1,
Glazing SHGC value (area-
SHGC:
SHGC:
❑Complies
See the Envelope Assemblies
402.3.2,
weighted average).
❑Does Not
table for values.
402.3i3
[FR3]
❑Not Observable
❑Not Applicable
402.1.1,
Door U-factor.
U-
U-
❑Complies
See the Envelope Assemblies
402.3.4
❑Does Not
table for values.
[FRI]1
❑Not Observable
❑Not Applicable
402.4.1.1
Air barrier and thermal barrier
❑Complies
[FR23]1
installed per manufacturer's
❑Does Not
instructions.a"
.°
❑Not Observable
❑Not Applicable
402.4.3
Fenestration that is not site built
❑Complies
[FR20]1
is listed and labeled as meetings
❑Does Not
AAMA /WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC
❑Not Observable
400 that do not exceed code,
❑Not Applicable
limits.
402.4.5 °..
IC -rated recessed lighting fixtures
6'
❑Complies
[FR16]2
sealed at housing/interior finish
�':
�. �`°
❑Does Not
°leakage
and labeled to indicate :52.0 cfm
at 75 Pa.
x t u
❑Not Observable
❑Not Applicable
403.3.1
Supply and return ducts in attics
° r
❑Complies
[FR12]1
insulated >= R-8 where duct is
_"°
❑Does Not
>= 3 inches in diameter and >_
;
'
❑Not Observable
R-6 where < 3 inches. Supply and
return ducts in other portions of
❑Not Applicable
the building insulated >= R-6 for.
diameter >= 3 inches and R-4.2
for < 3 inches in diameter.
403.3.5
Building cavities are not used as
`.
❑Complies
[FR15]3
ducts or plenums.
❑Does Not
❑Not Observable
❑Not Applicable
403.4.
HVAC piping conveying fluids
R-
R-
❑Complies
[F,R17]2 , .
above 105 °F or chilled fluids
❑Does Not
below 55 °F are insulated to >_R-
[-]Not Observable
❑Not Applicable
403.4.1
Protection of insulation on HVAC
❑Complies
[FR24]1
piping.
`❑Does
Not
❑Not Observable
❑Not Applicable
403.5.3
Hot water pipes are insulated to
R-
R-
❑Complies
,
[FR18]21'
>_R-3.
❑Does Not
'
❑Not Observable
❑Not Applicable
1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: M-1426 Report date: 07/09/18
Data filename: W:\on line. ntainc.com\050918-54\Project Documents\1426 RESCHECK.rck Page 4 of 9
section
`#
Framingo/ Rough In Inspection
Plans Verified
Field Ver�f�ed„
Comphes2
"'�
Comments/Assumptions
Value,
Value
,
&Jteq.ID,
_< a
40.35.5 °
Storage water heaters not
a
❑Complies
[FR26]?
equipped with integral heat traps
❑Does Not
and having vertical pipe risers
❑Not Observable
have heat traps installed on both
❑Not Applicable
the inlets and outlets. External
heat traps installed per code
guildlines.„
e
403.5 fi 1.1
Service water heating systems
w ,. P
❑Complies
1 „
are equipped with automatic
z
❑Does Not
[FR27]z "
temperature controls.a
r
❑Not Observable
❑Not -Applicable
403.5 6 L`
A separate switch permits the
y
❑Complies
2
power supplied to electric service
❑Does Not
[FR283 z
water systems to be turned off. A
xF
_ E`.
❑Not Observable
separate valve permits the
a ;
energy supplied to the main
��`
k .F� �k
+��'
❑Not Applicable
burner(s) of combustion types of
�U^�
„
service water heating systems to
be turned off.
4035 6:2 `
Water heating equipment meets
Table 404.2
Table 404.2
❑Complies
[FR293?'
minimum efficiencies of Table
(required
(required
❑Does Not
^'>
C404.2 in Chapter 4 of the
Ef):
Ef):
[]Not Observable
Florida Building Code, Energy
❑Not Applicable
Conservation, Commercial
Provisions. Equipment used to
provide heating functions as part
„.`
of a combination system satisfies
all stated requirements for the
appropriate water heating
category.
403`5.6.2.;
Solar systems for domestic hot
a: `r
❑Complies
1
water production satisfy energy
A,❑Does
Not
[FR
factor requirements determined_
F
❑Not Observable
-
from the Florida Solar Energy
r
❑Not Applicable
Center Directory of Certified
Solar Systems.
a
403:6
Automaticor gravity dampers are
a�
�'
❑Complies
Z
[FR193
installed on all outdoor air
t °10 y4s Y� 2 �§i ..$
ao p F ..
.. `.
❑Does Not
intakes and exhausts.
-
❑Not Observable
❑Not Applicable
403i6 2
Buildings designed to operate at%��
❑Complies
[FR313�
positive indoor pressure or have
�" ' ��
��
ODoes Not
mechanical ventilation meet they❑Not
Observable
following criteria: 1) Maximum
&
❑Not Applicable
air -change -hour equal minimums
�:
from ASHRAE 62, Ventilation for
Acceptable Indoor Air Quality, 2)
No ventilation'or air-conditioning
3.4
.
system make-up air provided
Y
from attics, crawlspaces,
E
attached enclosed garages or
a �,
A S
.g
outdoor spaces adjacent to
swimming pools or spas, and 3)
o
Air drawn from enclosed space(s)
-
have walls insulated >= R-11�
and ceiling >= R-19, space
permitting, or R-10 otherwise.
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 2;; Medium Impact (Tier 2) 3'^ Low Impact (Tier 3)
Project Title: M-1426 Report date: 07/09/18
Data filename: W:\online.ntainc.com\050918-54\Project Documents\1426 RESCHECK.rck Page 5 of 9
Section
#
Insulation Inspection
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.ID'
303.1
All installed insulation is labeled
❑Complies
[IN13]2
or the installed R-values
❑Does Not
01
provided.
❑Not Observable
❑Not Applicable
303.2
Wall insulation is installed per
❑Complies
[IN4]1
manufacturer's instructions.
❑Does Not
❑Not Observable
❑Not Applicable
303.2,
Floor insulation installed per
❑Complies
402.2.7
manufacturer's instructions and
❑Does Not
[IN2]1
in substantial contact with the
❑Not Observable
underside of the subfloor, or floor
framing cavity insulation is in
❑Not Applicable
contact with the top side of
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
r
top of all perimeter floor framing
members.
402.1.1,
Wall insulation R-value. If this is a
R-
R-
❑Complies
See the Envelope Assemblies
402.2.5,
mass wall with at least 1/2 of the
❑ Wood
❑ Wood
❑Does Not
table for values.
402.2.6
[IN3]1
wall insulation on the wall
exterior, the exterior insulation
❑ Mass
❑ Mass
❑Not Observable
{
requirement applies (FR10).
El Steel
❑Steel
❑Not Applicable
402.1.1, '
Floor insulation R-value.
R-
R-
❑Complies
See the Envelope Assemblies
402.2.6
❑ Wood
❑ Wood
❑Does Not
table for values.
[IN1]1
❑ Steel
❑ Steel
❑Not Observable
❑Not Applicable
40 .'2.14' =
[IN14]2 ` :
Walls, ceilings or floors common
to separate conditioned
❑Complies
❑Does Not
tenancies are insulated to >= R-
"^'
�`
❑Not. Observable
'
11, space permitting. Mass
common walls are insulated to
❑Not Applicable
>= R-6.
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 1 2 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: M-1426 Report date: 07/09/18
Data filename: W:\online.ntainc.com\050918-54\Project Documents\1426 RESCHECK.rck Page 6 of 9
sec#ion
'#
Plans Verified
Feld Verified;
`
•=Final,'ltispection PioV-isions.'
`n
.Value'
Value
Complies?
Comments/Assumptions
& Req.ID
=a= ._•
303.1.1.2.
Ceiling insulation installed per
❑Complies
1,303.2
manufacturer's instructions.
❑Does Not
[FI2]1
Blown insulation marked every
❑Not Observable
300 ftz .
❑Not Applicable
303.3
Manufacturer manuals for
z� '
❑Complies
[FI18]3.r�
mechanical and water heating
?
❑Does Not
_
systems have been provided.
❑Not Observable
❑Not Applicable
y:. g
401:3
An energy performance level
❑Complies
,'
(EPL) display card must be
❑Does Not
completed and certified by they
�� a
❑ Not Observable
builder before final approval of
;.�
the building for occupancy.
�=
r�
❑Not Applicable
Florida law (Section 553.9085,
8
Florida Statutes) requires the EPL
s
i
display card to be included as an
addendum to each sales contractT->-
for both presold and nonpresold
residential buildings. A copy of
;
the EPL card form can be found��
r
T
in Appendix C of the TB ,
'z
Energy Conservation".
����
402.1.1,
Ceiling insulation R-value.
R-
R-
❑Complies
See the Envelope Assemblies
402.2.1,
❑ Wood
❑ Wood
❑Does Not
table for values.
402.2.2,
❑ Steel
❑ Steel
❑Not Observable
402.2.6
❑Not Applicable
[Fill'
402.2 3
vented attics with air permeable
❑Complies
a�
[17I221�, '
insulation include baffle adjacent
❑Does Not
to so ffit and eave vents that
�� r
'
Observable
extends over insulation.
m❑Not
g
❑Not Applicable
402.2.4
Attic access hatch and door
R-
R-
❑Complies
[17I3]1
insulation >_R-value of the
❑Does Not
adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.1.2
Blower door test @ 50 Pa. <=7
ACH 50 =
ACH 50 =
❑Complies
[FI17]1
ach.
❑Does Not
❑Not Observable
❑Not Applicable
403:1 1 ,�
Each separate heating/cooling
tiT _
❑Complies
[FI9]? r:system
has a thermostat
"�`�
❑Does Not
❑Not Observable
i
❑NotApplicable .
4�03.1 2
Programmable thermostats
•.° ti -p
❑Complies
[17I9]1
installed for control of primary~�rc
❑Does Not
heating and cooling systems and
-
'�
❑Not Observable
initially set by manufacturer to
4
�t��
�°
❑Not Applicable
code specifications.,
r
�� ,,
403:1 3. _
Heat pump thermostat installed
��
❑Complies
[FI10]2
on heat pumps.
❑Does Not
❑Not Observable
e
cq
❑NotApplicable
403.2
Hot water boilers supplying heat
-]Complies
[F12612
through one- or two -pipe heating
❑Does Not
systems have outdoor setback
k,
m r;
❑Not Observable
control to lower boiler water
�'°,` ;'
A �.❑Not
Applicable
temperature based on outdoor
temperature.
=m �X
1 I High Impact (Tier 1) [Z'I Medium Impact (Tier 2) ' 3 I Low Impact (Tier 3)
Project. Title: M-1426 Report date: 07/09/18
Data filename: W:\online.ntainc.com\050918-54\Project Documents\1426 RESCHECK.rck Page 7 of 9
Section
#
Final Inspection Provisions
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req:ID
403.3.2,
All ducts, air handlers, and filter
❑Complies
403.3.2.1
boxes shall be constructed and
rr
❑Does Not
[FI24]1
sealed in accordance with
❑Not Observable
Section C403.2.9.2 of the
Commercial Provisions of this
❑Not Applicable
code. Air handler leakage
designated by manufacturer at
<=2% of design air flow.
403.3.3
Ducts are pressure tested to
cfm/100
cfm/100
❑Complies
(FI27]1
determine air leakage with
ft2
ft2
❑Does Not
either: Rough -in test: Total
❑Not Observable
leakage measured with a
pressure differential of 0.1 inch
❑Not Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g: across the entire system
including the manufacturer's air
handler enclosure.
403.3.4,
Duct tightness test result of <=4
cfm/100
. cfm/100
❑Complies
403.3.2
cfm/100 ft2 across the system or
ft2
ft2
❑Does Not
[FI411
<=3 cfm/100 ft2 without air
❑Not Observable
handler @ 25 Pa. For rough -in
tests, verification may need to
❑Not Applicable
occur during Framing Inspection.
Duct tightness verified by testing
in accordance with
ANSI/RESNET/ICC 380-2016 by
either individuals as defined in
Section 553.993(5) or (7), Florida
Statutes, or individuals licensed
as set forth in Section
489.105(3)(f), (g), or (i), Florida
Statutes, to be "substantially leak
free" in accordance with Section
R403.3.3.
403.3.6
Air handling units are not
(
❑Complies
[FI33]2
installed in attic.
' '
❑Does Not
"
❑Not Observable
U,
❑Not Applicable
403.5.1
Circulating service hot water
❑Complies
[FI11]2
systems have automatic or
❑Does Not
accessible manual controls.
s;
❑Not Observable
❑Not Applicable
403.5.1.1
Heated water circulation systems
❑Complies
[F128]2
have a circulation pump. The
❑Does Not
system return pipe is a dedicated
❑Not Observable
return pipe or a cold water supply
❑Not Applicable
pipe. Gravity and thermos-
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
"
when water is in circulation loop
is at set -point temperature and
no demand for hot water exists.
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: M-1426 Report date: 07/09/18
Data filename: W:\online.ntainc.com\050918-54\Project Documents\1426 RESCHECK.rck Page 8 of 9
Section;
#°
Final Inspection Provisions,
Plans Verified
Value
Field Verified
value
Complies?
`°
Comments/Assumptions",
& Req.ID"
403.5.12
Electric heat trace systems
❑Complies
[FI29]2 '
comply with IEEE 515.1 or UL
❑Does Not
515. Controls automatically
❑Not Observable
adjust the energy input to the
❑Not Applicable
heat tracing to maintain the
desired water temperature in the
P1Pin9•
403.5.2
Water distribution systems that
3
❑Complies
[F130]2°
have recirculation pumps that
❑Does Not
PUMP water from a heated water
❑Not Observable
supply pipe back to the heated
❑Not Applicable
water source through a cold
water supply pipe have a
demand recirculation water
F
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1049F.
403.5.4
Drain water heat recovery units
- ' °,
❑Complies
[F131]2
tested in accordance with CSA
❑Does Not
B55.1. Potable water -side
❑Not Observable
pressure loss of drain water heat
❑Not Applicable
•
recovery units < 3 psi for
individual units connected to one
,•
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
„.
403.6.1-
All mechanical ventilation system
❑Complies
[F1251? -
fans not part of tested and listed
❑Does Not
HVAC equipment meet efficacy
•__
[]Not Observable
and air flow limits.
❑Not Applicable
404.1
75% of lamps in permanent
r
❑Complies
[FI6]1
fixtures or 75% of permanent
x n
❑Does Not
fixtures have high efficacy lamps.
°
❑Not Observable
Does not apply to low -voltage
❑Not Applicable
lighting.
a.3
404.1.1
Fuel gas lighting systems have
❑Complies
[FM]3 ";
no continuous pilot light.
❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 18 1 Low Impact (Tier 3)
Project Title: M-1426 Report date: 07/09/18
Data filename: W:\online.ntainc.com\050918-54\Project Documents\1426 RESCHECK.rck Page 9 of 9