Loading...
HomeMy WebLinkAboutAPPROVE,D Roof InfoST. LUCIE Master Permit No. Contractors Name: Job Address_l Section A (General Information) Process No. License # IJ�.0 6.� 2, / 8 _ ROOF CATEGORY ❑ Low Slope ❑ MM hanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ❑Asphaltic Shingles [Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. New roof ❑ Repair ❑ Maintenance ❑ Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Q j—]Qf) Total (SF��Q6 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST. LUCIE WQRKc Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: Deck: IF 1 �� r Type: 1(— Gauge Thickness: ff Slope: t /l-2— Anchor/Base Sheet & No. df Ply(s): S-CR con (ed Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer:_ Base Insultation Size and Base Insulation Fastener, Top Insulation Layer: onding Material: Top Insulation Size and Ihickness: Top Insulation Fastener4Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s) Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_.._." oc @ Lap, # Rows @ " ac Zone 1:—" oc @ Lap, # Rows @ "ac Zone 2:—" oc @ Lap, # Rows @ "oc Zone 3:_.._." oc @ Lap, # Rows @ "oc Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zon-e�— Illustrate Components Noted and ils as Applicable: Woodblocking, Gutter, e Termination, Stripping, Flashing, Continuo Cleat, Cant Strip, Base Flashing, Counterflash' Coping, Etc., Indica . can Roof Height, Parapet Height, Height of Base F ing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 1 11 and Chapter 16.. kV v> INDIAN RIVER COUNTY BUILDING DEPARTMENT +{ .x �LORip� Gable Roofs >7 degrees to 45 degrees (>1'/z:12 to 12:12 Pitch) Gable and Flat Roofs 1.5/12 to less than 12/12 a off Cl 3r 20, ; 3r 3r -------------------------------------------- : 3r a= 4 Feet Roof Zones 160 Exp. 160 Exp. 160 Exp. 160 Exp. 160 Exp. 160 Exp. Slope B B C C D D One Story Two Story Two Story One Story Two Story >1 1/2 :12 Zone 1,2e -41.9 -51.0 -61.8 -71.4 -75.0 -84.7 to Zone2n,2r,3e -61.1 -74.5 -90.2 -104.3 -109.6 -123.7 4 1/2: 12 Zone 3r -66.5 -81.0 -98.1 -113.4 .119.1 .134.7 >4'/2:12 Zone 1,2e -32.3 -39.3 -47.6 -55.1 -57.8 -65.3 to Zone2n,2r,3e -51.5 -62.8 -76.0 -88.0 -92.4 -104.3 6:12 Zone 3r -55.7 -67.5 -81.7 -94.5 -99.3 -112.1 >6:12 Zone 1,2e,2r -38.1 -46.4 -56.2 -65.0 -68.3 -77.1 to Zone 2n,3r -41.9 -51.0 -61.8 -71.4 -75.0 -84.7 12:12 Zone 3e -48.1 -58.6 -71.0 -82.1 -86.2 -97.3 Roof Zones 150 Exp. 150 Exp. 150 Exp. 150 Exp. 150 Exp. 150 Exp. Slope B B C C D D One Story Two Story One Story Two Story One Story Two Story >1 '/2 :12 Zone 1,2e -36.9 -44.9 -54.4 -62.9 -66.1 -74.6 to Zone2n,2r,3e -63.7 -65.4 -79.2 -91.6 -96.2 -108.6 4'/2: 12 Zone 3r -58.4 -71.2 -86.2 -99.7 -104.7 -118.2 >41/2:12 Zone 1,2e -28.4 -34.6 -41.9 -48.5 -50.9 -57.5 to Zone2n,2r,3e -45.3 -55.2 -66.8 -77.3 -81.2 -91.7 6:12 Zone 3r -48.7 -59.3 -71.8 -83.1 -87.2 -98.5 >6:12 Zone 1,2e,2r -33.5 -40.8 -49.4 -57.2 -60.0 -67.8 to Zone 2n,3r -36.9 -44.9 -54.4 -62.9 -66.1 -74.6 12:12 Zone 3e -42.3 -51.5 -62.4 -72.1 -75.8 -85.5 Roof coverings installed on buildings with a Mean Roof Height of 30' or less Exposures B, C or D. Table R301.2 [2] altered per R301.2.1.6 of the FBC Residential. One Story max. roof height of 15 ft., Two Story max. roof height of 30 ft. Zone 3 based on Figure R301.2 [7] 160 mph winds east of 1 95 and 150 mph west of 195, per current I.R.C. Wind speed map. Diagrams from FloridaBuilding.org, 2020 Florida Building Code, Residential, 7th Edition Page 7 of 9 ST. LUCIE °` Section D (Steep Slope Roof System) Roof System Manufacturer: Notice of Acceptance Number: aoi�// Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1.101-Sone 2er—"one 2 Zone 2r��one 3e���one 3r:A*. Deck Type: Type Underla:yment: Roo Slope: 2 Insulation: Fire Barrier: Ridge Ventilation? Fastener Type & Spacing: t �� Adhesive Type: �w tej e L Type Cap Sheet I [Mean Roof Height:- Roof Covering: Type & Size Drip S �� Edge: