Loading...
HomeMy WebLinkAboutRoof formLuc" o fco LLP r T LUCIE COUNTY ROOFING PERMIT INFORMATION SKEET Florida Building Code 7th Edition (020) Based on Section 152_�p of the Florida Building Code - Building INSTRUCTION PACE CC)MPLETE THE NECESSARY SECTIONSOF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS (VOTED BELOW: Roof System Low Slope Application Prescriptive BIER-RAS 150 Asphaltic shingles - Concrete or Clay Tile Meta Roofs - Wood Shingles and Shakes Other -- — Required Sections of the Permit Application Farm A,B,C A, B, C A,B,D A, B, D, E A, B, D A,B,D AS Applicable -- - Attachments Required See List Below 1=4, 15A7 2AS,6,T 1 7 1, UAV t„4A6,7 1AA4A o7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings . Design Calculations per Chapter 26, or If applicable, RAS 127 or RAS 1 B 4. Other Component of Product Approval 5. Municipal Permit Application 6. 1 owners Notification for Rang ConsldeWions (Reroofing Only) 7, 1 Any Required Roof Testing/Calculation Documentation Farm RoofinfoFeb2i Rev Feb 18, 2021 Section A (General Information) Master Permit No. Process No. i' Contractors Name: De- o Job Addres5 M jp­ ROOF CATEGORY G Low Slope Z3 Mechanically Fastened Tile 11 Mortar/Adhesi►+e Set Tiles E3Asphaltic Shingles tal Panel/Shinilies Mood Shingles/Shakes 0 New roof © Repair how Slope Roof Area (SF) El Prescriptive BUR-RAS 150 ROOF ROOF TYPE- 0 Maintenance e ooflr�g -ROOF SYSTEM INFORMATION - Steep Sloped Roof Area {SF) El Recovering Total (SFJ Section B (Roof Nanj Sketch Roof Plan: Illustrate Ali levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. MEN SEEN MEMO MORME ■■ Ell i�°■uiuii�� mom 11RE INN i ST. Ll 'r* i c 1 Section D (Steep Slope Roof System) Root System Manufacturer: Notice of Acceptance Number: -mac. 1-0 1-;k- / 70 z2-. i Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: 2one 2e: Zone 2n:-Zone 2r:-----Zone 3e: - ne 3r: Mean Roof Height: Deck Type: Type Underleyment Insulation: Fire Barrier: ti Fastener Tpe & paeng: Adhesive Type: Type Cep Sheaf /C Roof Covering: L tk Type & Size Drip r Edge: Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from mf. if the Mr valuf}s are greater than or equal to the M, values, for each a rea of the roof, then the tile attachment method is ac-ceptable, Method 1 'Moment Based Tile Calculations Per RAS 12T (Zone 1: x � m Product Approval M {Zone 2e: 7K — Mg: �. M�, Product Approva (Zone 2n; _ x � i a-- Mg; __. = M� , Product Appr al Mf ItZone 2r: 7� — Mg: � i M Product Apt raval Mf Zone 3e: �� � — Mg: i = M,%-...� Produc Approval Mr„ .� (Zone 3 r: ,_._ — EiA : » Mra Pro icl Approval Method 2 "SlijmpiIfied Tile Calculations Per TAW e Below" Required Moment of Resistance (Mr) From Table Ulow� Product Ap IFoval M"--. M, requlred Moment Resistance* Mean hoof Height Roof Slope 15 21Y 25,1- 30' MY 2.12 34.4 36,5 38.2 39.7 42.2 3:12 32.2 34.4 "36.0 37.4 39.8 4:12 30A 32.2 33.8 35.1 373 9:12 28A .30.1 _ 31.6 32.9 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 . ' 27.1 28.2 30.0 *Must be used In conjunction with a list of moment based the systems — * For Upllfi Lased file systems use Method 8. Compare the values for F' wkh the values for Fr If the F' values are greater than or equal to the F, values, for each area of the roof, then the File attachment method is acceptable, Method 3 "UpiIft Based Tile Calculations Per RAS 12T (Zone 1: -----x L__ =x W-.m - r:� cos r,=Fri Product Approval F' (Zone 2e: � € L =�€ W: =___) -W: cos r =Frx Product Approval r (Zone 2n: _x L_ =x W: =----)"-W cos r =Fan Product Approval Fr (Zone 2r- -- x L�=x W.-z ) -Vie: cos r =Frz► Product Approval F' (Zone 3e: _ x L'=x Ulf:= -W:—Cos r =F.3. Product Approval F' (Zone 3r: x L =x W:= ) -Vie:, cos r— =Fr3r Product Approval V Where to Obtain Information -- De.scription Where t0 find From applicable Fable in RAS 127 or by an engineering analysts prepared by PE based on ASCE 7 Symbol Design Pressure Zones ], 2e, 2n, 2r, 3e, 3r — Mean Roof Height H Job Site Roof Slope Job Site 0 Aerodynamic Multiplier 3 M5 Product Approval Product Approval - Restoring Moment due to Gr"ty Attachment ReWstance Mr Product Approval - Required Moment Resistance Ma Calculated N1IMmurn Attwhrnenq Resistance V Product Approval Calculated - Required Uplift Resistance _ 1=F W Average Tile Weight ProductApproml Tile Dimensions L length W= width Product Approval All calculations must be submitted to the building officfal at the time of permit application Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (if a component is not used, identify as "NA") SYStem Manufacturer - Product Approval No.: Design wind Pressures, From RAS 128 Or Calculations: Zone 1' • —zone 1: Zone : Zone 3: _ Max. Design Pressure, from the specific product appridval system: Deck: Type ; _ jej Gauge Thickness: Slope; Anchor/Base Sheet & No_ df Ply( Anchor/Base Sleet Fastener/ onding Material: Insulation Rase Layer: _ Base Insultation Size and Base Insulation Fastener Top Insulation Layer: f hickness; Bonding Material: Top Insulation Size and Thickness: Tap Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s)- Base Sheet Fastener/Bonding Material: Ply Streets)' &, No. of PIV(s); ply Sheet FasteneIBon ding Material; Top Ply: Top Ply Fastener/Bonding Material: Surfacing. Fastener Spacing for hor/Base Sheet Attachment: Zone 1' @ Lap, # Rows 0"a Za/-Or- oc Lap, # Roves � � ac ZoLap, # Rows �. '° QC Zooc @ Lap, # Rows.. Q " as umber of Fasteners Per Insulation Board: Zone 1'_— Zone 1:—Zone 2:—Zone 3:_ Illustrate Components Noted and Details as Applicable- Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Materlail, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Detailsthat Comply with RAS 111 and Chapter 16. _