HomeMy WebLinkAboutAPPROVED Mullion Non-HVHZ FL 17472.2Document Title: Doc No: FRM B1-02
Structural Performance
Certification
Authorization Report
Rev No: 7 Page: 1 Of: 1
Required By: PRO B1-03
This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review,
and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in
accordance with the specified referenced standard. Actual fenestration product performance may vary based on many
factors, including installation, condition of the wall/roof substrate and the age of the product and installation
components.
This report indicates the product is eligible for the application of Keystone Certification Program certification labels.
Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen
evaluated and documented for certification authorization. Only products bearing such a certification label shall be
considered certified. The information in this report can be verified at www.keystonecerts.com.
622 -101.0
1/16/2015
7/18/2021
622
CAR & Product ID Number:
Issue Date:
Expiration Date:
Company Code:
Licensee Information: Product Information:
Model:1"x3-1/8" Light Alum Mullion H/V/T/X
Operator Type:Mull
Max Width:See Table
Max Height:See Table
Eastern Architectural Systems
16341 Domestic Avenue
Fort Myers FL 33912
Referenced Standard: Product Rating:
AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings
Config:No Reinforcement
Qualifying Test Information:
Test Report No:CTLA-3010W-4A/5A
Test Report Expiration:7/18/2021
Authorized Signature:Keystone Certifications, Inc.
145 Limekiln Rd. Suite 100B
New Cumberland, Pennsylvania 17070
Phone: 717-932-8500
Fax: 717-932-8501
Revision Date:2/16/2018
www.keystonecerts.com
Appendix 1 CAR No: 622‐101.0
Expiration Date: 7/18/2018
Keystone Certifications, Inc. 145 Limekiln Rd, Suite 100B New Cumberland, PA 17070
Phone: 717.932.8500
www.keystonecerts.com
Eastern Architectural Systems
10030 Bavaria Road
Fort Myers, FL 33913
Load Tables for the:
1”x3‐1/8” Light Aluminum Mullion, Horiz/Vert/T/X
DESIGN PRESSURE LIMITS FOR MULLION: 1" x 3‐1/8" (LIGHT) ‐ ONE‐WAY MULLIONS
SPAN 'L'
(IN.)
TRIBUTARY WIDTH 'W' (IN.)
18.00 24.00 30.00 36.00 42.00 48.00 54.00 60.00
24 200.00 200.00 200.00 200.00 200.00 200.00 200.00 200.00
36 200.00 200.00 200.00 200.00 200.00 200.00 200.00 200.00
48 200.00 200.00 200.00 200.00 200.00 200.00 200.00 200.00
60 200.00 200.00 200.00 191.43 176.70 167.50 162.42 160.80
72 180.07 141.81 119.42 105.04 95.33 88.63 84.03 81.03
84 111.13 86.82 72.48 63.14 56.70 52.09 48.74 46.30
96 73.35 56.98 47.27 40.91 36.46 33.24 30.83 29.01
108 50.93 39.39 32.53 28.01 24.84 22.51 20.75 19.39
DESIGN PRESSURE LIMITS FOR MULLION: 1" x 3‐1/8" (LIGHT) ‐ TWO‐WAY MULLIONS
SPAN 'L'
(IN.)
TRIBUTARY WIDTH 'W' (IN.)
18.00 24.00 30.00 36.00 42.00 48.00 54.00 60.00
24 200.00 200.00 200.00 200.00 200.00 200.00 200.00 200.00
36 200.00 200.00 200.00 200.00 191.43 167.50 148.89 134.00
48 200.00 200.00 200.00 167.50 143.57 125.63 111.67 100.50
60 200.00 200.00 160.80 134.00 114.86 100.50 89.33 80.40
72 157.56 118.17 94.54 78.78 67.53 59.09 52.52 47.27
84 99.22 74.42 59.53 49.61 42.52 37.21 33.07 29.77
96 66.47 49.85 39.88 33.24 28.49 24.93 22.16 19.94
108 46.69 35.01 28.01 23.34 20.01 17.51 15.56 14.01
Impact Ratings
ASTM E1996 – Wind Zone 4, Missile Level D
PA/TAS 201/203 – Large Missile and Small Missile compliant
Document Title: Doc No: FRM B1-02
Structural Performance
Certification
Authorization Report
Rev No: 7 Page: 1 Of: 1
Required By: PRO B1-03
This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review,
and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in
accordance with the specified referenced standard. Actual fenestration product performance may vary based on many
factors, including installation, condition of the wall/roof substrate and the age of the product and installation
components.
This report indicates the product is eligible for the application of Keystone Certification Program certification labels.
Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen
evaluated and documented for certification authorization. Only products bearing such a certification label shall be
considered certified. The information in this report can be verified at www.keystonecerts.com.
622 -102.0
1/16/2015
7/18/2021
622
CAR & Product ID Number:
Issue Date:
Expiration Date:
Company Code:
Licensee Information: Product Information:
Model:1"x3-1/8" Heavy Alum Mullion H/V/T/X
Operator Type:Mull
Max Width:See Table
Max Height:See Table
Eastern Architectural Systems
16341 Domestic Avenue
Fort Myers FL 33912
Referenced Standard: Product Rating:
AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings
Config:No Reinforcement
Qualifying Test Information:
Test Report No:CTLA-3010W-6A/7A
Test Report Expiration:7/18/2021
Authorized Signature:Keystone Certifications, Inc.
145 Limekiln Rd. Suite 100B
New Cumberland, Pennsylvania 17070
Phone: 717-932-8500
Fax: 717-932-8501
Revision Date:2/16/2018
www.keystonecerts.com
Appendix 1 CAR No: 622‐102.0
Expiration Date: 7/18/2018
Keystone Certifications, Inc. 145 Limekiln Rd. New Cumberland, PA 17319
Phone: 717.932.8500
www.keystonecerts.com
Eastern Architectural Systems
10030 Bavaria Road
Fort Myers, FL 33913
Load Tables for the:
1”x3‐1/8” Heavy Aluminum Mullion, Horiz/Vert/T/X
DESIGN PRESSURE LIMITS FOR MULLION: 1" x 3‐1/8" (HEAVY) ‐ ONE‐WAY MULLIONS
SPAN 'L'
(IN.)
TRIBUTARY WIDTH 'W' (IN.)
18 24 30 36 42 48 53.125 54 60
24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
60 200.0 200.0 200.0 191.4 176.7 167.5 162.2 161.6 159.4
72 200.0 154.5 126.8 109.1 97.1 88.9 84.0 83.3 79.7
84 126.2 96.1 78.4 66.8 58.9 53.2 49.6 49.1 46.1
96 84.2 63.9 51.8 44.0 38.5 34.5 31.9 31.5 29.3
108 58.9 44.6 36.1 30.5 26.6 23.7 21.8 21.5 19.9
DESIGN PRESSURE LIMITS FOR MULLION: 1" x 3‐1/8" (HEAVY) ‐ TWO‐WAY MULLIONS
SPAN 'L'
(IN.)
TRIBUTARY WIDTH 'W' (IN.)
18 24 30 36 42 48 53.125 54 60
24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
36 200.0 200.0 200.0 200.0 191.4 167.5 151.3 148.9 134.0
48 200.0 200.0 200.0 167.5 143.6 125.6 113.5 111.7 100.5
60 200.0 200.0 160.8 134.0 114.9 100.5 90.8 89.3 80.4
72 196.8 147.6 118.1 98.4 84.4 73.8 66.7 65.6 59.1
84 124.0 93.0 74.4 62.0 53.1 46.5 42.0 41.3 37.2
96 83.0 62.3 49.8 41.5 35.6 31.1 28.1 27.7 24.9
108 58.3 43.7 35.0 29.2 25.0 21.9 19.8 19.4 17.5
Impact Ratings
ASTM E1996 – Wind Zone 4, Missile Level D
PA/TAS 201/203 – Large Missile and Small Missile compliant
Document Title: Doc No: FRM B1-02
Structural Performance
Certification
Authorization Report
Rev No: 7 Page: 1 Of: 1
Required By: PRO B1-03
This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review,
and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in
accordance with the specified referenced standard. Actual fenestration product performance may vary based on many
factors, including installation, condition of the wall/roof substrate and the age of the product and installation
components.
This report indicates the product is eligible for the application of Keystone Certification Program certification labels.
Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen
evaluated and documented for certification authorization. Only products bearing such a certification label shall be
considered certified. The information in this report can be verified at www.keystonecerts.com.
622 -103.0
1/16/2015
7/18/2021
622
CAR & Product ID Number:
Issue Date:
Expiration Date:
Company Code:
Licensee Information: Product Information:
Model:1"x4" Aluminum Mullion H/V/T/X
Operator Type:Mull
Max Width:See Table
Max Height:See Table
Eastern Architectural Systems
16341 Domestic Avenue
Fort Myers FL 33912
Referenced Standard: Product Rating:
AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings
Config:No Reinforcement
Qualifying Test Information:
Test Report No:CTLA-3010W-8A/9A
Test Report Expiration:7/18/2021
Authorized Signature:Keystone Certifications, Inc.
145 Limekiln Rd. Suite 100B
New Cumberland, Pennsylvania 17070
Phone: 717-932-8500
Fax: 717-932-8501
Revision Date:2/16/2018
www.keystonecerts.com
Appendix 1 CAR No: 622‐103.0
Expiration Date: 7/18/2018
Keystone Certifications, Inc. 145 Limekiln Rd, Suite 100B New Cumberland, PA 17070
Phone: 717.932.8500
www.keystonecerts.com
Eastern Architectural Systems
10030 Bavaria Road
Fort Myers, FL 33913
Load Tables for the:
1"x4" Aluminum Mullion, Horiz/Vert/T/X
DESIGN PRESSURE LIMITS FOR MULLION: 1" x 4" ‐ ONE‐WAY MULLIONS
SPAN 'L'
(IN.)
TRIBUTARY WIDTH 'W' (IN.)
18 24 30 36 42 48 53.125 54 60
24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
72 200.0 200.0 200.0 181.5 161.6 147.9 139.7 138.6 132.6
84 200.0 159.9 130.4 111.2 98.0 88.5 82.5 81.7 76.7
96 140.1 106.3 86.3 73.2 64.1 57.4 53.1 52.5 48.8
108 98.1 74.2 60.1 50.8 44.3 39.5 36.3 35.9 33.1
DESIGN PRESSURE LIMITS FOR MULLION: 1" x 4" ‐ TWO‐WAY MULLIONS
SPAN 'L'
(IN.)
TRIBUTARY WIDTH 'W' (IN.)
18 24 30 36 42 48 53.125 54 60
24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 198.5
48 200.0 200.0 200.0 200.0 200.0 186.1 168.1 165.4 148.8
60 200.0 200.0 200.0 198.5 170.1 148.8 134.5 132.3 119.1
72 200.0 200.0 196.6 163.8 140.4 122.9 111.0 109.2 98.3
84 200.0 154.7 123.8 103.2 88.4 77.4 69.9 68.8 61.9
96 138.2 103.7 82.9 69.1 59.2 51.8 46.8 46.1 41.5
108 97.1 72.8 58.2 48.5 41.6 36.4 32.9 32.4 29.1
Impact Ratings
ASTM E1996 – Wind Zone 4, Missile Level D
PA/TAS 201/203 – Large Missile and Small Missile compliant
Document Title: Doc No: FRM B1-02
Structural Performance
Certification
Authorization Report
Rev No: 7 Page: 1 Of: 1
Required By: PRO B1-03
This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review,
and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in
accordance with the specified referenced standard. Actual fenestration product performance may vary based on many
factors, including installation, condition of the wall/roof substrate and the age of the product and installation
components.
This report indicates the product is eligible for the application of Keystone Certification Program certification labels.
Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen
evaluated and documented for certification authorization. Only products bearing such a certification label shall be
considered certified. The information in this report can be verified at www.keystonecerts.com.
622 -105.0
2/11/2015
7/18/2021
622
CAR & Product ID Number:
Issue Date:
Expiration Date:
Company Code:
Licensee Information: Product Information:
Model:2"x4" Aluminum Mullion H/V/T/X
Operator Type:Mull
Max Width:See Table
Max Height:See Table
Eastern Architectural Systems
16341 Domestic Avenue
Fort Myers FL 33912
Referenced Standard: Product Rating:
AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings
Config:No Reinforcement
Qualifying Test Information:
Test Report No:CTLA-3010W-8A/9A
Test Report Expiration:7/18/2021
Authorized Signature:Keystone Certifications, Inc.
145 Limekiln Rd. Suite 100B
New Cumberland, Pennsylvania 17070
Phone: 717-932-8500
Fax: 717-932-8501
Revision Date:2/16/2018
www.keystonecerts.com
Appendix 1 CAR No: 622‐105.0
Expiration Date: 7/18/2018
Keystone Certifications, Inc. 145 Limekiln Rd, Suite 100B New Cumberland, PA 17070
Phone: 717.932.8500
www.keystonecerts.com
Eastern Architectural Systems
10030 Bavaria Road
Fort Myers, FL 33913
Load Tables for the:
2"x4" Aluminum Mullion, Horiz/Vert/T/X
DESIGN PRESSURE LIMITS FOR MULLION: 2" x 4" ‐ ONE‐WAY MULLIONS
SPAN 'L'
(IN.)
TRIBUTARY WIDTH 'W' (IN.)
18 24 30 36 42 48 53.125 54 60
24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
72 200.0 200.0 200.0 200.0 200.0 197.0 188.0 186.8 180.1
84 200.0 200.0 195.1 166.4 146.6 132.5 123.5 122.2 114.8
96 200.0 159.0 129.1 109.5 95.9 85.9 79.5 78.5 73.0
108 146.7 111.1 89.9 76.0 66.2 59.1 54.4 53.7 49.5
DESIGN PRESSURE LIMITS FOR MULLION: 2" x 4" ‐ TWO‐WAY MULLIONS
SPAN 'L'
(IN.)
TRIBUTARY WIDTH 'W' (IN.)
18 24 30 36 42 48 53.125 54 60
24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
48 200.0 200.0 200.0 200.0 200.0 197.0 178.0 175.1 157.6
60 200.0 200.0 200.0 200.0 180.1 157.6 142.4 140.1 126.1
72 200.0 200.0 200.0 175.1 150.1 131.3 118.7 116.7 105.1
84 200.0 200.0 180.1 150.1 128.7 112.6 101.7 100.1 90.1
96 200.0 155.1 124.1 103.4 88.6 77.6 70.1 68.9 62.0
108 145.2 108.9 87.1 72.6 62.2 54.5 49.2 48.4 43.6
Impact Ratings
ASTM E1996 – Wind Zone 4, Missile Level D
PA/TAS 201/203 – Large Missile and Small Missile compliant
Document Title: Doc No: FRM B1-02
Structural Performance
Certification
Authorization Report
Rev No: 7 Page: 1 Of: 1
Required By: PRO B1-03
This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review,
and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in
accordance with the specified referenced standard. Actual fenestration product performance may vary based on many
factors, including installation, condition of the wall/roof substrate and the age of the product and installation
components.
This report indicates the product is eligible for the application of Keystone Certification Program certification labels.
Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen
evaluated and documented for certification authorization. Only products bearing such a certification label shall be
considered certified. The information in this report can be verified at www.keystonecerts.com.
622 -106.0
2/11/2015
7/18/2021
622
CAR & Product ID Number:
Issue Date:
Expiration Date:
Company Code:
Licensee Information: Product Information:
Model:2"x6" Aluminum Mullion H/V/T/X
Operator Type:Mull
Max Width:See Table
Max Height:See Table
Eastern Architectural Systems
16341 Domestic Avenue
Fort Myers FL 33912
Referenced Standard: Product Rating:
AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings
Config:No Reinforcement
Qualifying Test Information:
Test Report No:CTLA-3010W-8A/9A
Test Report Expiration:7/18/2021
Authorized Signature:Keystone Certifications, Inc.
145 Limekiln Rd. Suite 100B
New Cumberland, Pennsylvania 17070
Phone: 717-932-8500
Fax: 717-932-8501
Revision Date:2/16/2018
www.keystonecerts.com
Appendix 1 CAR No: 622‐106.0
Expiration Date: 7/18/2018
Keystone Certifications, Inc. 145 Limekiln Rd, Suite 100B New Cumberland, PA 17070
Phone: 717.932.8500
www.keystonecerts.com
Eastern Architectural Systems
10030 Bavaria Road
Fort Myers, FL 33913
Load Tables for the:
2"x6" Aluminum Mullion, Horiz/Vert/T/X
DESIGN PRESSURE LIMITS FOR MULLION: 2" x 6" ‐ ONE‐WAY MULLIONS
SPAN 'L'
(IN.)
TRIBUTARY WIDTH 'W' (IN.)
18 24 30 36 42 48 53.125 54 60
24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
72 200.0 200.0 200.0 200.0 200.0 197.0 188.0 186.8 180.1
84 200.0 200.0 200.0 191.0 171.5 157.6 148.7 147.5 140.1
96 200.0 200.0 186.8 161.6 144.1 131.3 123.0 121.8 114.6
108 200.0 197.0 162.7 140.1 124.2 112.6 104.9 103.8 97.0
DESIGN PRESSURE LIMITS FOR MULLION: 2" x 6" ‐ TWO‐WAY MULLIONS
SPAN 'L'
(IN.)
TRIBUTARY WIDTH 'W' (IN.)
18 24 30 36 42 48 53.125 54 60
24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
48 200.0 200.0 200.0 200.0 200.0 197.0 178.0 175.1 157.6
60 200.0 200.0 200.0 200.0 180.1 157.6 142.4 140.1 126.1
72 200.0 200.0 200.0 175.1 150.1 131.3 118.7 116.7 105.1
84 200.0 200.0 180.1 150.1 128.7 112.6 101.7 100.1 90.1
96 200.0 197.0 157.6 131.3 112.6 98.5 89.0 87.6 78.8
108 200.0 175.1 140.1 116.7 100.1 87.6 79.1 77.8 70.0
Impact Ratings
ASTM E1996 – Wind Zone 4, Missile Level D
PA/TAS 201/203 – Large Missile and Small Missile compliant