HomeMy WebLinkAboutAPPROVED 5v metal noa 2020 codeProfessionalBusiness &
Regulation
BCIS Home Log To User Registration Hot Topics i Submit SArcharge I Stats & Facts Public Oons Contact ils BCIS Site Map Links Seel rh
bpr
h
Product Approval
USER: i=abrc user
Product Auproval Menu > Product or A liration Search > huoiieaHon List > Application Uetai[
FL # FL20484-R2
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived i—i
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S. KING ST.
FAYETTEVILLE, NC 28301
(910) 813-2432
rbla ke@unioncorrugating.com
Authorized Signature Randy Blake
rblake@u nioncorrugating,com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 09/07/2027
Validated By Yoosef Lavi, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL20484 R2 COI Cerfficatelridependence.ladf
Standard
FM 4470
TAS 125
UL 1897
UL 580
Year
2016
2003
2012
2006
https:llwww.floridabuilding-orglprlpr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJ... 1 /12/2021
Florida Building Code Online
Page 2 of 3
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
10/10/2020
10/12/2020
10/22/2020
12/16/2020
FL # I Model, Number or blame I Description
20484.1 5V Min 26 ga., 24" wide through fastened panel over 15/32"
thick plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20464 R2 II EvaluationRenortC2401 1.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam, P.E. 52240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-169 Evaluation Reports
Other: Uplift load of 7 1. 0 psf @ fastener spacing of 24" o.c. FL20484 R2 AE EvaluationReoortC2401 1.pdf
& 169.0 psf @ fastener spacing of 6" o.c. Created by Independent Third Party: Yes
20484.2 Advantage-Lok II Min 26 ga., 16" wide concealed fastened panel over 7/16"
thick OSB & 15/32" & thick plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20484 R2 II EvaluationRe ortC2401 2. df
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A Created by independent Third Party: Yes
Design Pressure: +N/A/-131.5 Evaluation Reports
Other: Maximum uplift load of 131.5 psf @ seam fastener FL20484 R2 AF Eva luationReportC2401 2.pdf
spacing of 4-5/8" o.c. along seam into min. 15/32" thick APA Created by Independent Third Party: Yes
rated plywood with retainer strap.
20484.3
Aluminum Advantage-Lok II
Max 16.375" wide, nom 0.032" thick (min.) aluminum
concealed fastener roof panel over min 15/32" thick plywood
deck or 7/16" thick OSB.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R2 II Evaluation ReoortC240I 3.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Evaluation Reports
Other. Uplift load of 22.5 psf at fastener spacing of 18.5"
FL20484 R2 AE EvaluationReoortC2401 3.pdf
o.c. and 86.0 psf at fastener spacing of 4.63" o.c. in 15132"
Created by Independent Third Party: Yes
plywood or 7/16" OSB. Uplift load of 93.5 psf at fastener
spacing of 4.63" o.c. with adhesive in 15/32" plywood.
20484.4
Aluminum SL150
Max 16" wide, nom 0.032" thick (min.) aluminum snap -lock
standing seam metat panel over min 15/32" thick plywood
deck or 7/16" thick OSB
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R2 II FvaluationReportC2401 4 odf
Approved for use outside HVHZ: Yes
Verified By: Baia Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-86
Evaluation Reports
Other: Uplift load of 45.0 psf at clip spacing of 24" o.c. and
FL20484 R2 AF FvaluationReportC2401 4.pdf
78.5 psf at clip spacing of 6" o.c. in 15/32" plywood or 7/16"
Created by Independent Third Party: Yes
OSB. Uplift load of 86.0 psf at clip spacing of 6" o.c. with
adhesive in 15/32" plywood.
20484.5
MasterRib
Min 29 ga., 36" wide through fastened panel over 15/32"
thick plywood or 7/16" thick OSB
Limits of Use
Installation instructions
Approved for use in HVHZ: No
FL20484 R2 II Evaluation ReportC24015.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/--124
Evaluation Reports
Other: Uplift load of 56.0 psf @ fastener spacing of 24" o.c.
FL20484 R2 AE EvaluationeportC2401 5.odF
& 124.0 psf @ fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
20484.E
MasterRib
Min 29 ga., 36" wide through fastened panel over 15/32"
thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
F1.20484 R2 11 EvaluationRepartC2401 6.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-88.5
Evaluation Reports
Other: Uplift load of 56 psf for Fastening System 1. Uplift
FL20484 R2 AF EvaluationRe ortC2401 6.ji,df
load of 88.5 psf for Fastening System 2.
Created by Independent Third Party: Yes
https://www.floridabuilding.org/pr/Pr_app_dtl.aspx?pararn—wGEVXQwtDgsJ9a49YAgXJ... 1 /12/2021
Florida Building Code Online
Page 3 of 3
20484.7
ML150
Max 16.5" wide, min 24 ga. steel standing seam panel over
15/32" thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R2 11 EvaluationReportC2401 7.1)df
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-124
Evaluation Reports
Other: Maximum uplift load of 124 psf @ clip spacing of 6"
FL20484 R2 AE EvaluationReoortC2401 7.pdf
o.c. with 180 seam, self -adhering membrane and fixed clip.
Created by Independent Third Party: Yes
20484.8 7P311
or R Panel
Mtn 26 ga., 36" wide through fastened panel over 15/32"
thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R2 1I Evaluation Re ortC2401 df
Approved for use outside HVHZ: Yes
Verified By: Bala 5ockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161.5
Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 48" o.c.
FL20484 R2 AE EvaluationReportC2401 8.odf
and 161.5 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
20484.9
SL175
Max 18" wide, min 24 ga., snap -lock standing seam metal
panel over 15132" thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
1`1_20484 R2 11 EvaluationReportC2401 9.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Evaluation Reports
Other: Uplift load of 39.8 psf @ clip spacing of 36" o.c. and
FL20484 R2 AE FvaluationReportC2401 9.odf
78.5 psf @ clip spacing of 8" o.c with felt. Uplift toad of 93.5
Created by Independent Third Party: Yes
psf @ clip spacing of 12" o.c. with self -adhering membrane.
Sack Next
Contact Us 2601 Blair Stone Road, Tallahassee FL 32399 Phone, 850-487-1824
The State of Florida is an AA/EEO employer. Convrieht 2007-2013 State of Florida.:: Privacy Statement Accessibility Statement :: Refund State_mert
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional its€i. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455,275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. IF you do not wish to supply a personal address,
please provide the Department with an email address which can he made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
® ® ® gig
Credit Card
Safe
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJ... 1 /12/2021
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
`26 GA. 5V PANEL'
FLORIDA BUILDING CODE 7TH EDITION (2020)
FLORIDA PRODUCT APPROVAL
FL 20484.1-R2
ROOFING
METAL ROOFING
Prepared For -
Union Corrugating Company
701 S. King St.
Fayetteville, NC 28301
Telephone: (910) 483-0479
Fax: (910) 483-1091
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
Load Span Table (1 Page)
Report No. C2401-1
Date: 10.10.2020
aS�,C'KA L�IVQ 6-
g �l0 622 �
OF
1 Q•
FL 20484.1-R2
C2401-1
10.10.2020
Page 2 of 3
Manufacturer: Union Corrugating Company
Product Name: 5V Panel
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755). Corrosion resistant as per FBC 2020 Section 1507.4.3.
Deck Description: Min. 15/32" thick APA rated plywood or min. 3/4" thick wood plank
(min SG of 0.42) for new and existing constructions. Designed by
others and installed as per FBC 2020.
New Underlayment: Minimum Underlayment as per FBC 2020 Section 1507.4.5.1.
Required for new construction.
Existing Underlayment: One layer of asphalt shingles over one layer of 430 felt. For reroofing
(Optional) construction only.
Slope: 112:12 or greater in accordance with FBC 2020 Section 1507.4.2
Design Uplift Pressure: 71.0 psf at fastener spacing of 24" o.c.
(Factor of Safety = 2) 169.0 psf at fastener spacing of 6" o.c.
Panel Attachment: #10-15 x 2" long wood screw with washer. Fasteners are corrosion
resistant as per FBC 2020 Section 1507.4.4.
At interior max 12" o.c. across panel width through panel rib
At panel ends max 6" o.c. across panel width through panel flat and rib
Minimum fastener length of 1.5" for new construction. For existing
construction, fastener shall be of sufficient length to penetrate through
the deck a minimum of 318".
Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance
of Roof Assemblies' & U1,1897-04 `Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply with test procedures
prescribed in UL 1897-12.
Code Compliance: The product described herein has demonstrated compliance with FBC
2020 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with. FBC 2020 Section 1609 or ASCE 7-16 using allowable stress
FL 20484.1-R2
C2401-1
10.10.2020
Page 3 of 3
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
computed using rational analysis prepared by a Florida Professional
Engineer or based on Union load span table. This evaluation report is
not applicable in High Velocity Hurricane Zone. Refer to current NQA
for use of this product in High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2020 Section 1505 and current approved roofing materials
directory or ASTM E108/UL790 report from an accredited laboratory
for fire ratings of this product.
Supporting Documents: UL580 & UL1897 Test Reports
Farabaugh Engineering and Testing Inc.
Project No. T197-16, Reporting Date 5/12/16
PANEL OVERLAP
NEW UNOERIAYMENT PANEL FASTENER
ROOF PANEL SEE DETAIL 2 SEE DETAIL ) SPACING PER ALLOWABLE
UPLIFT PER
TABLE
EXISTING DNQERLAYMEM EXISTING SHINGLES
(OPTIONAL) (OPTIONAL)
e
DECK ATTACHMENT AND PLYWOOD
SDpppgTS MUST BE 15/32 THICK (MIN.)
DESIGNED AND INSTALLED
BY OTHERS
�....� �
TRU55 AT M.AX. 24" O.C.
010-15 X 2" LONG WOOD
SCREW WITH WASHER
NEW UNDERLAYVENT
EXISTING UNDERLAYMENT
(OPTIMAL)
DETAIL 1
P0-15 X 2" LONG WOOD
SCREW WITH WASHER
NEW UNDERLAYMENT
EXISTING UNDERLAYMENT.— v
(OPTIONAL) DETAIL 2
TYPICAL PANEL INSTALLATION X-SECTION
26 GA. PANEL
EXISTING SHINGLES
(OPTIONAL)
PLYWOOD
15/32" THICK (MIN.)
a Sm
GENERAL NOTES:
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
-
FLORIDA BUILDING CODE (FBC). -
2. ROOF PANELS SHALL BE MINIMUM 26 GA. EFFECTIVE COVERING WIDTH OF�
PANEL = 24'.
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
MIN 26 GA. PANEL
SPECIHLD ON THIS ➢RAWING.
Q_ REQUIRED DESIGN WIND LOADS SHALL 8E DETERMINED FOR EACH PROJECT.
TM15 PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAO TABLE.
5. ALL FASTENER5 MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
EXISTING SHINGLES
OF TH15 DRAWIST NG E. THE CODE SHALL D
(OPTIONAL)
6. RAFTERS/JOISTS/TRUSSES MUUIREMENTS
BE O TO WITHSTAND WIND LOAD'SL AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
PLYWOOD
15/32" THICK (MIN.)
UNION CORRUGATING COMPANY
5V Panel Uplift Loads
(Min 26 ga.)
Description
Fastener Spacing
along Panel Length
(in)
Allowable Uplift
Lead
(psf)
Coverage width, 24"
Panel Fasteners
#10-15 hex head screws with
sealed washer
Panel fasteners spaced at 12"
o.c. across panel width
through ribs.
6
169.0
158.1
147.2
S
10
12
136.3
121.7 -
14 T
16
106.5
94.7
18
20
85.2
22
77.5
24
71.0
Notes:
I. The bold numbers indicate design loads calculated from test data with safety factor of 2.
2. Panels must be installed as per Evaluation Report FL 20484.1 and Union current installation procedure.
1216 N Lansing Ave., Suite C
Tulsa, Ok 74106
918 492 5992
�GCKA E',v. 'Fa
tee' �,P-.,G� N S�`�'•:4��`��
No 62240 .!
��•� STATE OF
10. %O .2012.0
Bala Sockalingam. Ph.D., P.E.
FL 62240