Loading...
HomeMy WebLinkAboutAPPROVED Specialty Window NON-HVHZ FL 14608.83/17/2021 Florida Building Code Online Professional 1 , / BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map Links Search bpr,-a a Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL14608-R12 Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft. Myers, FL 33912 (800) 432-2204 Ext4305 jflesher@easternmetal.com Authorized Signature James Flesher jflesher@easternmetal.com Technical Representative Jim Flesher Address/Phone/Email 10030 Bavaria Rpad Fort Myers, FL 33913 (800) 432-2204 jflesher@easternmetal.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2011 ASTM E1886 2012 ASTM E1996 2012 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL14608 R12 Equiv FL14608 AAMA EQ,pdf FL14608 R12 Equiv FL14608 ASTM EQ,pdf https://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7Zpdfbg71 X7FgCl m KBtlfjFag3KZjeCnA%3d%3d 1 /3 3/17/2021 Florida Building Code Online Product Approval Method Method 1 Option A Date Submitted 02/23/2021 Date Validated 02/25/2021 Date Pending FBC Approval Date Approved 03/02/2021 Summary of Products FL # Model, Number or Name Description 14608.1 Series "FWI 2000" Aluminum Impact Series "FWI 2000" Aluminum Impact Fixed Window Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14608 R12 C CAC NI009023.01-R3-signed.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 02/28/2021 Design Pressure: +90/-90 Installation Instructions Other: Maximum Size: 144" x 48". GLASS INTERLAYER FL14608 R12 II 08-02395B.pdf COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 BUILDING CODE ACCORDING TO MIAMI-DADE FOR EASTMAN Created by Independent Third Party: Yes INTERLAYERS Evaluation Reports FL14608 R12 AE 513168C.pdf Created by Independent Third Party: Yes 14608.2 Series 1436 Vinyl Non -Impact Fixed Series 1436 Vinyl Non -Impact Fixed Window with Nailing Fin Window with Nailing Fin Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14608 R12 C CAC NI010609-R2.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/31/2024 Design Pressure: +80/-80 Installation Instructions Other: Maximum Size: 71 1/2" x 71 1/2". Frame material to FL14608 R12 II 08-00557C.pdf be rigid PVC from Deceuninck North America AAMA Certified Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 (DEP-1) Created by Independent Third Party: Yes Evaluation Reports FL14608 R12 AE 510946B.pdf Created by Independent Third Party: Yes 14608.3 Series 1446 Vinyl Non -Impact Fixed Window with Flange Series 1446 Vinyl Non -Impact Fixed Window with Flange Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14608 R12 C CAC NI010609.01-R2.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/31/2024 Design Pressure: +80/-80 Installation Instructions Other: Maximum Size: 74 1/2" x 72". Frame material to be FL14608 R12 II 08-00559C.pdf rigid PVC from Deceuninck North America AAMA Certified (DEP- Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 1) Created by Independent Third Party: Yes Evaluation Reports FL14608 R12 AE 510948C.pdf Created by Independent Third Party: Yes 14608.4 SERIES 176 PW PVB VINYL PICTURE SERIES 176 PW PVB VINYL PICTURE WINDOW WINDOW Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: RIGID PVC FROM DECEUNINCK NORTH AMERICA AAMA CERTIFIED (DEP-1). GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR KURARAY INTERLAYERS Certification Agency Certificate FL14608 R12 C CAC NI015127.pdf Quality Assurance Contract Expiration Date 11/30/2024 Installation Instructions FL14608 R12 II 08-03661.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL14608 R12 AE 514777.pdf Created by Independent Third Party: Yes 14608.5 Series 176 Vinyl Impact Fixed Series 176 Vinyl Impact Fixed Window with Flange HVHZ Window with Flange HVHZ Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80.0/-80.0 Certification Agency Certificate FL14608 R12 C CAC NI011878.01-R2.pdf FL14608 R12 C CAC NI011878-R2.pdf FL14608 R12 C CAC NI011879.01-R2.pdf FL14608 R12 C CAC NI011879-R2.pdf https://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7Zpdfbg71 X7FgClmKBtlfjFag3KZjeCnA%3d%3d 2/3 3/17/2021 Florida Building Code Online Other: Maximum Size: 72" x 63". Frame material to be rigid Quality Assurance Contract Expiration Date PVC from Deceuninck North America AAMA Certified (DEP-1). 01/31/2022 WHEN INSTALLED IN THE HVHZ THIS PRODUCT IS TO BE Installation Instructions INSTALLED AT 30' OR LESS ABOVE GROUND LEVEL. GLASS FL14608 R12 II 08-02294C.pdf INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE Verified By: Luis R. Lomas, P.E. 62514 FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR Created by Independent Third Party: Yes KURARAY INTERLAYERS Evaluation Reports FL14608 R12 AE 513043D.pdf Created by Independent Third Party: Yes 14608.6 Series 176 Vinyl Impact Fixed Series 176 Vinyl Impact Fixed Window with Flange HVHZ Window with Flange HVHZ Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14608 R12 C CAC NI011880.01-R2.pdf Approved for use outside HVHZ: Yes FL14608 R12 C CAC NI011880-R2.pdf Impact Resistant: Yes FL14608 R12 C CAC NI011881.01-R2.pdf Design Pressure: +80.0/-80.0 FL14608 R12 C CAC NI011881-R2.pclf Other: Maximum Size: 72" x 84". Frame material to be rigid Quality Assurance Contract Expiration Date PVC from Deceuninck North America AAMA Certified (DEP-1) 01/31/2022 WHEN INSTALLED IN THE HVHZ THIS PRODUCT IS TO BE Installation Instructions INSTALLED AT 30' OR LESS ABOVE GROUND LEVEL. GLASS FL14608 R12 II 08-02293C.pdf INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE Verified By: Luis R. Lomas, P.E. 62514 FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR Created by Independent Third Party: Yes KURARAY INTERLAYERS Evaluation Reports FL14608 R12 AE 513042D.pdf Created by Independent Third Party: Yes 14608.7 Series 2456 Vinyl Impact Fixed Series 2456 Vinyl Impact Fixed Window with Nailing Fin Window with Nailing Fin Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14608 R12 C CAC NI010610-R2.pdf Approved for use outside HVHZ: Yes FL14608 R12 C CAC NI010656-R2.pdf Impact Resistant: Yes Quality Assurance Contract Expiration Date Design Pressure: +50/-50 06/30/2024 Other: Maximum Size: 64" x 84". Frame material to be rigid Installation Instructions PVC from Deceuninck North America AAMA Certified (DEP-1). FL14608 R12 II 08-00563C.pdf GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE Created by Independent Third Party: Yes FOR EASTMAN INTERLAYERS Evaluation Reports FL14608 R12 AE 510952B.pclf Created by Independent Third Party: Yes 14608.8 Series 2466 Vinyl Impact Fixed Series 2466 Vinyl Impact Fixed Window with Flange Window with Flange Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14608 R12 C CAC NI010610.01-R2.pdf Approved for use outside HVHZ: Yes FL14608 R12 C CAC NI010656.01-R2.pdf Impact Resistant: Yes Quality Assurance Contract Expiration Date Design Pressure: +60/-60 06/30/2024 Other: Maximum Size: 64" x 84". Frame material to be rigid Installation Instructions PVC from Deceuninck North America AAMA Certified (DEP-1). FL14608 R12 II 08-00565C.pdf GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE Created by Independent Third Party: Yes FOR EASTMAN INTERLAYERS Evaluation Reports FL14608 R12 AE 510954C.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: = ® ® Kid E Credit Gard Safe https://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7Zpdfbg71 X7FgClmKBtlfjFag3KZjeCnA%3d%3d 3/3 NOTICE OF PRODUCT CERTIFICATION to CERTIFIcq,� A ,� 4f� + � ®rx N 1 [7 AIENYI� F �F7ED P CERTIFICATION NO: DATE: CERTIFICATION PROGRAM: COMPANY: CODE: REVISION DATE: NI010610.01-112 05/09/2011 Structural Eastern 1783-1 02/11/2020 To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series "2466" Impact Rated 10030 Bavaria Road Vinyl Fixed Window Ft. Myers, FL 33913 w/Flange Frame Configuration: O Glazing: IG-3/16" Annealed Glass/ Laminate-3/16" Annealed Glass/0.075" Solutia Sea Storm Interlayer/3/16" Annealed Glass Frame: W-1626mm(64") H-2134mm(84") DLO: W-1486mm(58.5") H-2007mm(79") SPECIFICATION PRODUCT RATING ASTM E1886-02/E1996-02 Design Pressure: +60/-60 psf Wind Zone 4-Missile Level D Product Tested By: Report No: Expiration Date: June 30, 2024 Administrator's Signature: Certified Testing Laboratories. CTLA-2062W-5 .004 NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 NOTICE OF PRODUCT CERTIFICATION to CERTIFIcq, f, A� pCCk�.4f� + � ®rx N 1 ED PR� CERTIFICATION NO: DATE: CERTIFICATION PROGRAM: COMPANY: CODE: REVISION DATE: NI010656.01-112 05/24/2011 Structural Eastern 1783-1 09/17/2019 To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series 112466" Vinyl 10030 Bavaria Road Impact Fixed Window Ft. Myers, FL 33913 Configuration: O Glazing: IG-3/16" Annealed Glass/ Laminate-3/16" Annealed Glass/0.075" Sea Storm Solutia/3/16" Annealed Glass Frame: W-1626mm(64") H-2134mm(84") DLO: W-1495mm(58.88") H-2003mm(78.88") SPECIFICATION PRODUCT RATING AAMA/WDMA/CSA 101/I.S.2/A440-05 FW-C80 1626 x 2134 (64 x 84) Product Tested By: Architectural Testing, Inc. Report No: 68099.03-701-47 Expiration Date: September 30, 2024 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 L. Roberto Lomas P.E. 1432 Woodford Rd Lewisville, NC 27023 434-688-0609 Manufacturer: Eastern Architectural Systems 16341 Domestic Ave FT Myers, FL 33912 Product Line: 2466 Picture Window Engineering Evaluation Report Report No.: 510954C Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a). The product listed herein complies with requirements of the Florida Building Code. Supporting Technical Documentation: 1. Approval document: drawing number 08-00565 revision C, prepared, signed and sealed by Luis Roberto Lomas P.E. 2. Test Report No.: CTLA-2062W-5 signed and sealed by Ramesh Patel, P.E. Certified Testing Laboratories, Orlando, FL. ASTM E1886/ E1996 Large Missile Impact Test, Level D, Wind Zone 4 Cyclic Load Test, ±60.0 psf design pressure 3. Test Report No.: ATI 68099.03-701-47 signed by Michael L. Mackereth Architectural Testing, York, PA. AAMA/WDMA/CSA 101/I.S.2/A440 Design pressure: ±80.Opsf Water penetration resistance 12.Opsf 4. Anchor calculations, report number 510954, prepared, signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: ±60.Opsf • Maximum unit size: 64" x 84" • Units must be glazed per ASTM E 1300. See installation instructions for details. • This product is not rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection in wind borne debris regions. • PVC profiles certified by AAMA Deceunick North America DEP-1 and VBP-2 Installation: Units must be installed in accordance with approval document, 08-00565 revision C. Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). 1 of 1 . , ! (P TAT rOF OR Ot Luis R. Lomas, P.E. FL No.: 62514 10/24/2020 REVISIONS NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1 X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE IX BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1 /1 6" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1 /4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. REV DESCRIPTION DATE APPROVED A MANUFACTURER'S NAME CHANGE 03/03/09 R.L. B UPDATED PER NEW CERTIFICATION 06/26/14 R.L. C REVISED INSTALLATION DETAILS 06/22/15 R.L. 15. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1 /4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1 /2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17. ALL FASTENERS TO BE CORROSION RESISTANT. 18. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD MINIMUM SPECIFIC GRAVITY OF G-0.42 B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 1/8" THICK MINIMUM 19. UNITS MAY BE INSTALLED WITH OR WITHOUT ADD —ON FLANGE. TABLE OF CONTENTS 1 SHEET NO.I DESCRIPTION 1 1 I NOTES 2 I ELEVATION 3 — 4 I INSTALLATION DETAILS SIGNED: 0612312015 EASTERN ARCHITECTURAL SYSTEMS � 1 L 1 l l 11 l/ A DIVISION OF ,1 ■ Eastern EASTERN METAL SYPPLY ,,;�+ R , L 0 f� „ ALUM1NlJM qHQ of �y� 16341 DOMESTIC AVE ., • • I C f ♦ �/ �..,.raer w�.aa.,.• ....a ws FORT MYERS, FLORIDA 33912 = • �Cj Ly ♦ •�7 800-432-2204 • 2466 PICTURE WINDOW f: *■ p $q 64 x 84 • NOTES o'00�w TAT QF .��� DRAWN: DWG NO. REV /,��n ��0R`�� A.ME oarE 08 s00565 C AL SCALE NITS 7 /29 /08 1 OF 4 WOOD FRAMING OR 2X BUCK BY OTHERS APPROVED SEALANT #10 WOOD SCREW CVTCn►!1 n APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS ►A►-rr!'n►nn tUht UIJI/HIHI t 1 1?" MIN. DISTANCE MIN. v1ENT AX. ACE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 M ETAL STRUCTURE BY OTHERS APPROVED SEALANT EXTERIOR APPROVED {. SEALANT E M ETA MIN. STRUCTUR v1ENT BY OTHER 3/4" MIN. FF)rF N'�TANC'F I ►A ►-rcn ►/'N n 3/4" MIN. EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION REVISIONS REV DESCRIPTION DATE APPROVED A MANUFACTURER'S NAME CHANGE 03/03/09 R.L. B UPDATED PER NEW CERTIFICATION 06/26/14 R.L. C REVISED INSTALLATION DETAILS 06/22/15 R.L. 3/4" MIN. EDGE DISTANCE #10 SMS OR SELF DRILLING SCREWS M ETAL STRUCTURE BY OTHERS 1 /4" MAX. SHIM SPACE INTERIOR APPROVED EXTERIOR SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION 1 1 /4" MIN. 1 /4" MAX. EMBEDMENT SHIM SPACE 1/2" MIN. EDGE DISTANCE INTERIOR SMS OR #10 WOOD a F DRILLING SCREW ;EW WOOD FRAMING 1 /4" MAX. OR 2X BUCK EXTERIOR SHIM SPACE BY OTHERS APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION SIGNED: 0612312015 EASTERN ARCHITECTURAL SYSTEMS 1 � 1 l l l ill 1 l/ AS Wd A DIVISION OF , ■ astern EASTERN METAL SYPPLY R , L OIff�� • ■ A•f �Q _ FORT MYYERS, FLORIDA 33912 = • •�Cj tr �~ . •�7 A LUMINLJM AHQ YlHTL 800-432-2204 . �► . 2466 PICTURE WINDOW *■ o 64 x 84 INSTALLATION DETAILS O�w TAT QF DRAWN: DWG No. REV SACAME 08 s00565 c AL SCALE NDATE TS 7 /29 /08 3 OF 4 CONCRETE/MASONRY BY OTHERS OPTIONAL 1 X BUCK SEE NOTES 3-7 SHEET 1 APPI SE APPROVED SEALANT OPTIONAL IX BUCK SEE NOTES 37 SHEET 1 CONCRETE/MASONRY BY OTHERS 7 1 /')" KAINI EDGE DISTANCE VERTICAL CROSS SECTION CONCRETE/MASONRY INSTALLATION REVISIONS REV DESCRIPTION DATE APPROVED A MANUFACTURER'S NAME CHANGE 03/03/09 R.L. B UPDATED PER NEW CERTIFICATION 06/26/14 R.L. MIN. C REVISED INSTALLATION DETAILS 06/22/15 R.L. MENT 1 1 /4" MIN. EMBEDMENT CONCRETE/MASONRY BY OTHERS D OPTIONAL 1 X BUCK a 1 /4" MAX. SEE NOTES 3-7 SHEET 1 e ° SHIM SPACE p D v 3/16" TAPCON D� v v D Dv �� INTERIOR v 2 1 /2" a MIN. ° EDGE DISTANCE °� D O D a v EXTERIOR APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 0612312015 MIN. �A VIENT +■•� Eastern EASTERN ARCHITECTURAL SYSTEMS DIVISION y ,,,,y�� rrrr� EASTERN ,�;.�5 R. L o,f,� 'EN'. . • ` • FORT MYYERS, FLORIDA 33912 800-432-2204 ~ �• • ii • +� �• y` �� •� 2466 PICTURE WINDOW *■ p $q �• * �_ 64 x 84 INSTALLATION DETAILS O�w TAT OF DRAWN: DWG NO. REV • /,��n �L0R N ME 08 c ALIEa.�`� SA. DATE NTS 7 /29 /08 s00565 4 OF 4 110