HomeMy WebLinkAboutAPPROVED Rico-Metal Alliance-24ga-1.5 inch-FL Approval.pdf 1/1 21202 1 Florida Building Code Online
4:
Business & Professional Regulation
BCIS Home Leg In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Lime: Search
Ada
Product Approval" pr
lim-
USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL29523-Rl
f Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Metal Alliance Inc.
Address/Phone/Email 2120 SW Poma Dr.
Palm City, FL 34990
(844) 638-2548
orders@metalalliance.com
Authorized Signature Tara Faulkner
orders@metalalliance.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2030
Validated By lames R Wally, PE
Validation Checklist- Hardcopy Received
Certificate of Independence EL29523 RI COl 32AI 100SL p ywo0d nonHVH;'_pdf
Referenced Standard and Year(of Standard) Standard Year
TAS 100 1995
TAS 125 2003
UL580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
https:/ANww.floridabuilding-org/pr/pr app_dtl.aspx?param=wGEVXQwtDquDjJZGKCHOBeuJtRZVS4wAPLbCuLWfBsMgrM4sxtfrSA%3d%3d 113
1/12/2021 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 08/11/2020
Date Validated 08/13/2020
Date Pending FBC Approval 08/19/2020
Date Approved 10/13/2020
Summary of Products
FL• Model,Number or Name Description
29523.1 01: 100SL 1"Nallstrlp 032 Aluminum SOOSL 1"Nallstrip panel from nominal 0.032"aluminum or
thicker on 15/32"(min)plywood or 3/4"(min)wood plank
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL29523 RI It 32AI SOOSL p)ywogd nonHVHZ.odf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-168.5 Evaluation Reports
Other: 168.5 psf @ 6"oc FL29523 RI AE 32AI 1095L (11 wood ngnHVHZ.g f
Created by Independent Third Party:Yes
29523.2 02: 100SL 1"Nallstrip 24ga 100SL 1"Nailstrip panel from 24ga(min)on I5/32"(min)
plywood or 3/4"(min)wood plank
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL29523 RI II 24ga 100SL plywood nonHVHZ.odf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-206 Evaluation Reports
Other: 206 psf @ 6"oc FL29523 R1 AE 24ga 100SL plywood aQaLWHZ.oQf
Created by Independent Third Party: Yes
29523.3 03: 100SL 1"Nailstrip 26ga HVHZ 100SL 1"Nailstrip panel from 26ga(min)on 15132"(min)
plywood or 3/4" (min)wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL29523 RI Il 26ga 1005L pl wv ood.p9lf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-176 Evaluation Reports
Other: 176 psf @ 6"oc WITH sealant, 116 psf @ 6"oc without FL29523 Rl AE 26ga 100SL plywood.gd(
sealant Created by Independent Third Party:Yes
29523.4 04: 100SL I"Nallstrip 032 Aluminum 100SL 1"Nallstrip panel from nominal 0.032"aluminum or
HVHZ thicker on 15/32"(min)plywood or 3/4"(min)wood plank
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL29523 R3 11 32AI IOOSL plyWkQd.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-175 Evaluation Reports
Other: 175 psf @ 6"oc WITH sealant FL29523 R3 AE 32AI 100SL olywood.odf
Created by Independent Third Party:Yes
29523.5 05: 150SL 1.5" Nallstrip 24ga 150SL 1.5"Nallstrip panel from 24ga(min)on 15132"(min)
plywood or 3/4"(min)wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL29523 RI 11 24ga 1505E olywood rQUHVHZ.pf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/Ay-153.5 Evaluation Reports
Other: 153.5 psf @ 6"oc WITH sealant FL29523 RS AE 24ga 150SL plywood nonHVHZ.ILdf
Created by Independent Third Party:Yes
29523.6 06: 1SOSL 1.5" Nailstrip 032 1SOSL 1.5"Nailstrip panel from nominal 0.032"aluminum or
Aluminum thicker on 15/32"(min) plywood or 3/4"(min)wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL29523 RS 11 32AI 150SL plywood nonHVHZ.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-168.5 Evaluation Reports
Other: 168.5 psf @ 6"oc WITH sealant FL29523 R1 AE 32AI ISOSL pjywootl nonHVHLPdff
Created by Independent Third Party:Yes
29523.7 07: 150SL 1.5" Nailstrip 032 150SL 1.5" Nailstrip panel from nominal 0.032"aluminum or
Aluminum HVHZ thicker on 15/32"(min) plywood or 3/4"(min)wood plank I
19"coverage
Limits of Use Installation Instructions
https:/twww.floddabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquDjJZOKCHOSouJtRZVS4wAPLbCuLVMsMgrM4sx,tfrSA%3d%3d 2/3
1/12/2021 Florida Building Code Online
Approved for use in HVHZ:Yes FL29523 Rl if 32AI 1505L Dlywood.Ddf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party:Yes
Design pressure:+N/A/-168.1 Evaluation Reports
Other: 168.1 psr 0 6"oc WITH sealant FL29523 R1 AE 32AI 150SL Dlywood.Ddf
Created by Independent Third Party:Yes
29523.8 08: 150SL 1.5"Nailstrip 24ga HVHZ 150SL 1.50 Nailsbip panel from 24ga(min)on 15/32" (min)
plywood or 3/4"(min)wood plank 1 19"coverage
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL29523 R1 II 24ga 1505E Dlv_ff g pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-112.5 Evaluation Reports
Other: 112.5 @ 6"oc WITH sealant FL29523 RS AE 24ga 150SL QbwD4d,adf
Created by Independent Third Party:Yes
Bad N<xt
Contact Us::2601 Blair Some Road,Tallahassee FL 32399 Phone:850-4E7-1824
The State of Florida is an AMEEO employer.$,9Rvrioht 2007-2013 State of Ronda.::privacy Statement::Aacesibility Statement::Refund Statement
Under Moral law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entry.Instead,contact the oMce by phone or by traditional mall.If you have any questions,please contact B50.4a7.1395.*Pursuant to Sect on 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls
provided may the used for of caul communication wall the licensee.however email addresses are public record.If you do not wish m supply a personal address,please
provide Me Department with an email address which can be made available to the public.To determine If you are a licensee under chapter 455,F.S.,please dick b=.
Product Approval Accapio:
®KI ® EI
Credit Card
Sale
https://www.floridabuilding.org/pr/pr_app_dd.aspx7param=wGEVXOwtDquDjJZOKCHOBeuJtRZVS4wAPLbCuLWf8sMgrM4sxtfrSA%3d%3d 3/3
METAULLIANCE
A Value Added Supplier of Metals Ado
1 . 5 " NailStrip 24ga Steel Panels
24ga ( min ) 1.5" Nail Strip over 15/32" (min ) plywood
Metal Alliance, Inc
2120 SW Poma Dr I Palm City FL 34990
Produced by Metal Alliance's Network of Approved Regional Manufacturers
Product Description
Noilstrip, snaplock style panel with a 15" maximum panel width and a
nominal rib height of 1.5"
Product Material
24ga (min) steel
24ga is nominally 0.0239" with yield strength of at least 50ksi, and shall be corrosion
resistant per FBC 1507.4.3 where required.
Fastener
#10 1-inch pancake style fastener
Compliant with FBC 1506.6 where required.
Substrate/ Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave #2061 Gainesville FL
FL PE 81377 1 FL CA 33344 QP' 10EN
1 S'
www_TimberLake C_ove.co_m
No. 81377
;gyp STATE OF !(yam\
On `1
09vid E Eng
.10
15 0 S L — - - 19:18: 7-0
19:18:07-04'00'
This item has been digitally signed and sealed
1.5" NAI LSTR I P 24GA by D E Eng,PE,on the date indicated Printed
copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies
Underlayment: Comply with local building code or FBC 1507.1.1 where required.
Slope: Comply with local building code or FBC 1507.4.2 where required.
Re-Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511, provided the existing roof meets the conditions required by
the applicable code.
Maximum Allowable Loads & Installation Requirements:
Method A: #10_x_ 1" fasten,e_r_at 6" o.c. alon nail strip_WITH sealant:_153.5 PSF
A factor of safety of 2 has been applied.
Fasteners are installed through the metal flange, NOT through the pre-punched slots.
Technical Documentation:
This product has been tested to the UL 580 standard by Intertek Testing (TST-1527), report
J6368.12-450-44 RO.
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2
(non-HVHZ) as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any
company manufacturing or distributing products under this evaluation. The same entities do
not have, nor will acquire, a financial interest in any other entity involved in the approval
process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be
completed by others. Fire classification and shear diaphragm design are outside the scope of
this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as
required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible
for any conclusions, interpretations, or designs made by others based on this evaluation
report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no
express or implied warranty regarding performance of this product.
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use
of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across-wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
METALALLIANCE
A Value Added Supplier of Metals
ENGINEERING LOAD TABLES
Instructions: i a
Select the appropriate load table that applies to e 2 2 3
the structure in question. a
2
Determine the design wind speed for the project 1 2
location. 2\.
2- 2 _ a .
Use the attachment method indicated for that 2 1 �_--- --- - .-3
2 2 -3 a
windspeed within each roof zone. 1
2
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone 2 1 1 2
concept. For the load tables below, the worst case f
was taken for each zone and reported using the a---131 2 -2
standard zones 1-2-3: 11
Zone 1 includes zones 1 and 1' -- a— HIPROOF DABLEROOF —a—
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3e and 3r
rn Aa¢reAwxeP a.usuR oA o r.aR Arnw.L cTm
Combining these zones creates a clear, simple ROOF ZONES FOR GENERIC BUILDING
scheme, at the expense of some design efficiency.
Contact Metal Alliance Inc for further information,
or consult a licensed design professional.
METHOD A
FEMALE LEG SNAPS
Ot OMALE LEG
SEA NT APPLIED TO
BOTH SIDES
V FASTENER
AT Bb G
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B, C,or D exposure area
Have either a flat roof.or gable/hip roof with max slope of 45° Have either a flat roof.or gable/hip roof with max slope of 450
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL29523.05: 24 a 150SL 1.5" nail strip on 15/32" plywood FL29523.05: 24 a 150SL 1.5" nail strip on 15/32" Dlvwood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A
Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A
Zone 3: A A A A A A A A A A A Zone 3: A A A A A A A
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located In B, C,or D exposure area
Have either a flat roof less than 7°,hip roof with Have either a flat roof less than 7°, hip roof with
max slope of 45°,or gable roof with slope between 20'and 45' max slope of 45°, or gable roof with slope between 20°and 45'
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL29523.05: 24 a 150SL 1.5" nail strip on 15/32" plywood FL29523.05: 24 a 150SL 1.5" nail strip on 15/32" I wood
Ein
nd 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
ne 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A Ae 2: A A A A A A A A A A A Zone 2: A A A A A A A A A Ane 3: A A A A A A A A A A A Zone 3: A A A A A A A A
METAULLIANCE
A Value Added Supplier of Metals 'A