Loading...
HomeMy WebLinkAboutPermit WorksheetPERMIT WORKSHEET Page 1' of 2 PERMIT NUMBER Installer CHARLES P. ROGERS License S IH1025311 Manufacturer PALM HARBOR Leng • x width 38.0'/32'8" X_ 24.0' b1 � FEMA or Riverins Zone X & AE Mininumum Required Elevation Floor at or above Min. Required Eievevation OR Minimum W' Piers ❑ Address of home 5348 GALLEY WAY FT PIERCE, FL 34949 Note: Compete diagram below orsuberlt separate diagram. I understand Lateral Arm Systems cannot be used on any home (new or used where the sidewali tie spaong exceeds 5 fr 4 in Typical pier spacing 2' . In. r/ lnstailes initials a�c_ - Lateral Show locations of Longitudinal and Lateral System L g iel Stabilizing Devke {LSD) h oif—Wicturer Model g Longitudinal Stabi0dog Devke W/ Lateral Arms Manufacturer HOME PRIDE Model # LOCK DOWN New Home ® used Home ❑ Home installed to the Manufacturi;r's Installation Manu Home is installed in accordance with Rule 15-C ❑ Single wide ® Wind Zone II ❑ Wind Zone III Double wide Q Installation Decal # TBD TriplelQued ❑ Serial # PER SPACING TABLE FOR USED HOMES Load bearing capacity Fouler {sq siza I 16" x IV (256) 181/2" x 181l2" (342) 20" x 21V (400) 22" x 22" (48V 24" X 24° (578)• 26" x 28• (678) 1000 s 3500 psf at I 8' a' • Interpolated from Mule 15C-1 pier spacing table. PIER PAD SiZE.S !-beam pier pad size 17.5 X 25.5 Perimeter pier pad size Eat er pmr pad sizes (required by the mfg.) 13 x 26 VARIES PER ATTACHED "U,, Draw the approximate locations of marriage wall openings 4 foot or greater. Use this symbol to show the piers. List all marriage wall openings greater than 4 foot and their pier pad sizes below. Opening Pier pa"jze SEE ATTACHED FACTORY DIAGRAM DETAILS POPULAR i�AQ SIZES _ Pad Sipe Sq In 16 x 16 266 16 x i8 288 1&5x k 72.0: 17 x 22 374 13114 x 26114 348 17112 x 22112 394 20 x 2Q 400 17 3t16 x 25 3116 441 24 x 24 676 26 x 26 1 676 d4i iGt�l3$ 4 ft 5 It ❑ FRAME TES X Within 2' of and of home x spaced at 54" oa Uj Bihar Ties Plumber Marriage wall 4 Sidewall 15 Shearwall 4 Longitudinal 4 c W PERMIT WORKSHEET Ipage 2 of 2 PERMIT NUMBER The pocket penetrometer tests are rounded down to Of or check here to declare 1000 lb. soil x without testing. PWKET PEm TR=ETrER Tess i rrie iS;cTmon, 1. Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the tooter. 3. using 5W lb Increments, take the lowest reading and round down to that increment. x....... X. x_._, The results of the torque probe test is NIA inch pounds or check if you are declaring S' anchors without testing . A test showing 275 inch pounds or less will require 6 foot anchors. Note: A state approved lateral arm system is being used and 4 ft. anchors are allowed at the sidewall locations. I understand 6 It anchors are required at all centerline tie points where the torque test reading is 275 or less and w1we the mobile home manufuscturer may requires anchors with 4000 122 h ldi capacity. Installer's initials ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER Installer Name CHARLES P. ROGERS Date Tested Conti& electrical conductors between multi`" units, but not to the main power Conn�all sewer drains to an existing sewer tap or septic tank. Pg. 54-55 Connn t, all potable water supply piping to an existing water meter, ►ester t_p, or ether independent water supply systems. Pg. 78 repast on Debris and organic material removed Water drainage: Natural Swale Other na muuld w units Floor. Type Fastener. LAGS Length: 6° Spacing: 16" Walls: Type Fastener: LAGS Length: 6" Spacing: 12" Roof Type Fastener LAGS Lengin: 6" Spying: 12" For used homes a min. 30 gauge, W wide, galvanized metal strip will be centered over the peak of the root and fastened with gals. roofing nails at 2" on center on both sides of the centerline. [waifh�nxoaNnanau► I understand a property Installed gasket is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result of a poorly installed or no gasket being installed. I understand a strip of tape will not serve as a gasket. Installer's initialsofi^- Type gasket FACTORY INSTALLED Installed: Pg. 36 Between Floors Yes Between Wells Yes Bottom of ridgebeam Yes sa ng The bottomboard wilt be repaired and/or taped 6�( pg. 94 Siding on units is installed to manufacturer's sQ "cation. W Fireplace chimney installed so as not to allow intrusion of rain water, Wiiseeilanoous Skirting to be installe Ye No Qryer vent insured outside of skirting. Ya> NJA Rarhgs downflow vent installed outside of 'tting(� WA Qrain lines supported at 4 foot in ais. Yes Electrical crossovers protected es Ocher - hataller verities all Inforimation given with this permit worksheet Is accurate and true based on the manufacturer's installation Instructions and or Rule 15C-1 & 2 Installer Signature 0� �� ..,, Date