HomeMy WebLinkAboutSewage Final ApprovaleBridge, Web Viewer Page 1 of 9
• APPLICATION # : AP 1612764
STATE OF FLORIDA PERMIT #:56-SF-2220899
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:F11584083
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:01/13/2021
-�� Wei FEE PAID:95.00
RECEIPT #.56-PID-4855955
APPLICANT: Alexander Hensley J
AGENT: Leyva Plumbing Srvs,
PROPERTY ADDRESS: 1901 S 33rd St Fort Pierce, FL 34947
LOT: 22,23,24 BLOCK: 3
SUBDIVISION: Westwood Manor ID#: 2417'-702.0048.000-9
CHECKED [XI ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION SETBACKS
[ 1 (011 TANK SIZE [13 [21- L 1 (273 SURFACE WATER FT
( 3 [021 TANK MATERIAL ( 1 [281 DITCHES FT
[ ) [03) OUTLET DEVICE [ 1 [291 PRIVATE WELLS FT
[ 1 (041 MULTI -CHAMBERED [ Y. / N 1 [ 1 [303 PUBLIC WELLS FT
[ 1 [051 OUTLET FILTER [ 3 [313 IRRIGATION WELLS FT
( ) (063 LEGEND 1. 2. ( 1 [321 POTABLE WATER FT
[ 1 (073 WATERTIGHT [ 1 [331 BUILDING FOUNDATIONS FT
[ 1 [081 LEVEL ( 1 [341 PROPERTY LINES FT
[ 1 [091 DEPTH TO LID [ 1 [351 OTHER FT
DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM
[ ) [101 AREA [1) (21 SOFT ( 1 [361 DRAINFIELD COVER
[ 1 1111 DISTRIBUTION BOX HEADER [ 1 (371 SHOULDERS
[ 1 [121 NUMBER OF DRAINLINES 1. 2. [ 1 [381 SLOPES
[ 1 (131 DRAINLINE SEPARATION ( 1 (391 STABILIZATION
L 1 [141 DRAINLINE SLOPE
[ 1 [151 DEPTH OF COVER ADDITIONAL INFORMATION
[ 1 [161 ELEVATION ( ABOVE J BELOW IBM [ 1 [401 UNOBSTRUCTED AREA
[ 1 [171 SYSTEM LOCATION [ 1 [411 STORMWATER RUNOFF
[ 1 (181 DOSING PUMPS [ 1 (421 ALARMS
[ 1 (191 AGGREGATE SIZE ( 1 1431 MAINTENANCE AGREEMENT
L 1 (201 AGGREGATE EXCESSIVE FINES [ 1 [441 BUILDING AREA
[ 1 [211 AGGREGATE DEPTH [ 1 [451 LOCATION CONFORMS WITH SITE PLAN
FILL / EXCAVATION MATERIAL ( 1 (461 FINAL SITE GRADING
[ ) [221 FILL AMOUNT ( 1 [471 CONTRACTOR Abner Leyva (Leyva Plumbing
( 1 (231 FILL TEXTURE [ 1 [481 OTHER
( ) (241 EXCAVATION DEPTH ABANDONMENT
L 1 [25I AREA REPLACED L 1 [491 TANK PUMPED 02/22/2021
( ) [261 REPLACEMENT MATERIAL [ 1 [501 TANK CRUSHED S FILLED 02/22/2021
Comments: Comments are on page 2.
CONSTRUCTION [ APPROVED J r_ St. Lucie CHD DATE: 02/22/2021
DISAPFROVED 1: Env ro mental Specialist jKplan J Ingram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM ( APPROVED J DISAPPROVED ) : St. Lucie CHD DATE: 02/22/2021
Environmental Spod Ill Brian J Ingram (ENVIRONMENTAL HEALTH)
(Explanation of Violations on following pago)
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1612764 E102220890
https://s1.ebridge.com/ebridge/3.0/webviewer/Viewer.aspx?ref=dkk5Ki7Exi%2fNvpTQt3gTLoOX... 4/23/2021
e Bridge, Web Viewer
Page 2of9
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
'y 1 CONSTRUCTION INSPECTION AND FINAL APPROVAL
APPLICATION # : AP 1.612764
PERMIT #:56-SF-2220899
Dommar # : FI1584083
DATE PAID : 01 /13/2021
FEE PAID:95.00
rZA Dlr) ASiRtiOACZ
1t�lailYT $:VV-1 Iy-TV Vvv vv
Violation Number Comment
Comments
Unpermitted tank was installed, but never used. No pumping required. ST abandoned.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1GU764 EID2220899
https://sl .ebridge.com/ebridge/3.0/webviewerNiewer.aspx?ref=dkk5Ki7Exi%2fNvpTQt3gTLoOX... 4/23/2021
eBridge, Web Viewer
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL
SYSTEM
CONSTRUCTION PERMIT FOR: OSTDS Abandonment
APPLICANT: Alexander Hensley
PROPERTY ADDRESS: 1901 S 33rd St Fort Pierce, FL 34947
LOT: 22.23,24 BLOCK: 3
SUBDIVISION: Westwood Manor
Page 3 of 9
PERMIT #:56-SF-2220899
APPLICATION #:AP1612764
DATE PAID:
FEE PAID:
RECEIPT #:
DOCUMENT # : PR1498371
PROPERTY ID #: 2417'-702-0048-000-9 [SECTION,. TOWNSHIP, RANGE, PARCEL NUMBER]
[OR TAX ID NUMBER]
SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION
381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE
SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS,
WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID.
ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND SPECIFICATIONS
T [ ] GALLONS / GPD CAPACITY
A [ ] GALLONS / GPD CAPACITY
N ( ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps
D [ ] SQUARE FEET SYSTEM
R ( I SQUARE FEET SYSTEM
A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [ ] MOUND [ ]
I CONFIGURATION: [ ] TRENCH [ ] BED [ J
N
F LOCATION OF BENCHMARK:
I ELEVATION OF PROPOSED SYSTEM SITE [ J[ / ][ABOVE/ BELOW] BENCHMARK/REFERENCE POINT
E BOTTOM OF DRAINFIELD TO BE [ j[ / I ABOVE / BELOW I BENCHMARK/REFERENCE POINT
L
D FILL REQUIRED: r 0.001 INCHES EXCAVATION REOUIRED: r 1 INCHES
0
T
H
E
R
Have the tank abandoned in accordance with the following procedures: (a) The tank shall be pumped out.(b) The bottom of
the tank shall be opened or ruptured, or the entire tank collapsedso as to prevent the tank from retaining water, and(c) The
tank shall be filled with clean sand or other suitable material, and completely covered with soil.Have the system inspected
by the health department after it has been pumped and ruptured but before it is filled with sand and covered.
SPECIFICATIONS BY: � TITLE:
APPROVED BY: TITLE: Environmental Specialist II St. Lucie CHD
Brian J yngram
DATE ISSUED: 01/13/202 EXPIRATION DATE: 04113/2021
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 1 of 3
v 1.2.4 API G' 276: SF.
https://s1.ebridge.com/ebridge/3.0/webviewerNiewer.aspx?ref=dkk5Ki7Exi%2fNvpTQt3gTLoOX... 4/23/2021
eBridge, Web Viewer
NOTICE OF RIGHT,,
Page 4of9
A party whose substantial interest is affected by this order may petition for an
administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such
proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for
administrative hearing must be in writing and must be received by the Agency Clerk for the
Department, within twenty-one (21) days from the receipt of this order. The address of the
Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency
Clerk's facsimile number is 850-413-8743.
Mediation is not available as an alternative remedy.
Your failure to submit a petition for hearing within 21 days from receipt of this order will
constitute a waiver of your right to an administrative hearing, and this order shall become a'final
order'.
Should this order become a final order, a party who is adversely affected by it is entitled
to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are
governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced
by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a
second copy, accompanied by the filing fees required by law, with the Court of Appeal in the
appropriate District Court. The notice must be filed within 30 days of rendition of the final order.
https://sl .ebridge.com/ebridge/3.0/webviewerNiewer.aspx?ref=dkk5Ki7Exi%2fNvpTQt3gTLoOX... 4/23/2021
eBridge- Web Viewer Page 5 of 9
St. Lucie County Health Department
H0iH 5150 NW Milner Dr Port Saint Lucie, FL 34983
PAYING ON: a 6 SF-222089 BILLDOC#:56-BID-5152019 CONSTRUCTION APPLICATION 4: AP1612764
RECEIVED FROM: Lewa Plumbinq Srvs. AMOUNT PAID: $ 95.00
PAYMENT FORM: CREDIT CARD 000475 PAYMENT DATE: 01/13/2021
MAIL TO: Alexander Hensley
FACILITY NAME:
PROPERTY LOCATION:
1901 S 33rd St
Fort Pierce, FL 34947
Lot: 22,23.24
3
Block:
Property ID: 2417'-702-0048-000-9
EXPLANATION or DESCRIPTION: QUANTITY FEE
147 - OSTDS Construction Pert Based - Abandonment
-1 - Surcharge (All)
RECEIVED BY: AdamsC
1 $ 50.00
1 $ 45.00
AUDIT CONTROL NO. 56-PID-4855955
https://s1.ebridge.com/ebridge/3.0/webviewerNiewer.aspx?ref=dkk5Ki7Exi%2fNvpTQt3gTLoOX... 4/23/2021
eBridgq Web Viewer
r
Page 6of9
STATE OF FLORIDA
DEPARTMENT OF HEALTH
p ONSITS SEWAGE TREATMENT AND DISPOSAL
SYSTEM
APPLICATION FOR CONSTRUCTION PERMIT
APPLICATION FOR:
PERMIT NO.✓� !/✓
DATE PAID:
FEE PAID:
RECEIPT #:
( ] New System [ ] Existing System ( ] Holding Tank [ ] Innovative
( j Repair [�/] Abandonment [ ] Temporary [ ]
APPLICANT: A1exC4^,jer
AGENT: ,t4/a 0 L,4y-,n6ngj SL-r V, ce s TELEPHONEi 7pG'-5�(-6 Z$ Q
MAILING ADDRESS: 1SG> Z 5,� yy-% er+; d A%k Q:2c± Sc4',r+ Lo r-,' �� 7
aeaannnnaaaoaaaaaaaavaaaaaaaacaacaaaaaaaacaaaaooaoaaaaaaaaaaaaaaancaa=aaa=aaaeeaae=aeaa=aa
TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED
BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE
APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR
PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS.
ancaaaaaaaaaoacaaa�aaaaaaneoaaaacaaaaaaaaaaaaaaaaaoaaaaaaaanaaaoaaaanaaaaaaacaanocaaaavaaa
PROPERTY INFORMATION
LOT: 12-2 Zi BLOCK: 3 SUBDIVISION: 11JGSjI'Vw d Ance ee- PLATTED:
PROPERTY ID #: VDI-702- cl;1/13 -- 00-0- ! ZONING: I/M OR EQUIVALENT: [ Y / N ]
PROPERTY SIZE: Q.� Qj ACRES WATER SUPPLY: [ ] PRIVATE PUBLIC [x]<a2000GPD [ 1>2000GPD
IS SEWER AVAILABLE AS PER 381.0065, FS? [ Y/O ] DISTANCE TO SEWER: FT
PROPERTY ADDRESS: �1,161 S -33(.t) 19rr"eet- Fvct' p;erCe, FL 311911 i
DIRECTIONS TO PROPERTY:
BUILDING INFORMATION
Q(I RESIDENTIAL
[ ] COMMERCIAL
Unit Type of
No. of Building
Commercial/Institutional System Design
No Establishment
Bedrooms Area Sgft
Table 1, Chapter 64E-6, FAC
1 sins), 9'I'yl4 'CKi�/�(e
Z �i1Z�',!-t'.C�
?'�t'G:n
j
-dre: 1V
2
3
4
[),_] Floor/Equi t Drains
[ ] Other (Specify)
8XGNATUREs
DATE:
C)%^
DH 4015, 08/09 (obso ttea previous editions which may not be used)
Incorporated 64E-6.001, FAC
Page 1 of 4
https://sl .ebridge.com/ebridge/3.0/webviewerNiewer.aspx?ref=dkk5Ki7Exi%2fNvpTQt3gTLoOX... 4/23/2021
eBridge Web Viewer Page 7 of 9
STATE OF FLORIDA PERMIT #
DEPARTMENT OF HEALTH
r ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
EXISTING SYSTEM AND SYSTEM REPAIR EVALUATION
.yepD N�'�c
APPLICANT: Ales c nmder
CONTRACTOR/AGENT:
n * , Ser-v
I I— 24/1 T- 702 - cxP'i$ -
LOT: ,`7Zr� BLOCK: _ SUBDIV: WeshJ,,uJ AACt-la' ID#: - 0 j(-
a a ca aaa_a� _aa0aa _tea cacao as a aaaaaa Doaa aaaaaaaa as as Ca nn aaaaaa aaaaaaa aaaaa aaaaaaaaaanaa � a_ �-��� - ��
TO BE COMPLETED BY FLORIDA REGISTERED ENGINEER, DEPARTMENT EMPLOYEE, SEPTIC TANK CONTRACTOR OR
OTHER CERTIFIED PERSON. SIGN AND SEAL ALL SUBMITTED DOCUMENTS. COMPLETE ALL APPLICABLE ITEMS.
COMPLETE TANK CERTIFICATION BELOW OR NOTE IN REMARKS WHY THE`TANKS CANNOT BE CERTIFIED.
aaaaaa=aaaaaacacccaaaacaa=aa=a�aacaaaac----------a-as-na-as-aa-as-aa-aa as aa-aa-aa-.aanaaaaaaaa-
EXISTING TANK INFORMATION
[ /1 dco ] GALLONS SEPTIC TANK / GPD ATU LEGEND . L U S - 5 � / MATERIAL: CCPCrZte_ BAFFLED:. [ Y IN )
[. ] GALLONS SEPTIC TANK / GPD ATU LEGEND: MATERIAL: BAFFLED. [ Y / N I
L l GALLONS GREASE INTERCEPTOR LEGEND- MATERIAL:
[ ) GALLONS DOSING TANK LEGEND: MATERIAL: # PUMPS:[
I CERTIFY T THE LISTED TANKS WERE PUMPED ON ii / %/� ? BY A<- -'ay% SCQ+jr_ ' tZ+nIC_ , HAVE
THE VQLUMES PECI IED AS DETERMINED .`BY [ DIMENSIONS / FILLING / LEGEND .I , ARE FREE OF OBSERVABLE
DEFE S OR BAKS AND HAVE A [ SOLIDS DEFLECTION DEVICE / OUTLET FILTER DEVICE ) INSTALLED.
�e��+� nl�„-r,h�n� sen��c�s a/
SIG AT' OF, 'I ENSED CONTRACTOR BUS3fNHSS AM DATE
EXISTING DRAINFIELD INFORMATION
[-2006 ) SQUARE FEET PRIMARY DRAINFIELD SYSTEM NO. OF TRENCHES [ ] DIMENSIONS: 1Z, X
[ ] SQUARE FEET SYSTE14 NO. OF TRENCHES [ ] DIMENSIONS: X
TYPE OF SYSTEM: i-A STANDARD [ ) FILLED [ ] MOUND [ )
CONFIGURATION: TRENCH I j BED [ ] s
DESIGN: [ ) HEADER [ ] D-BOX [>C] GRAVITY SYSTEM [ ) DOSED SYSTEM
ELEVATION OF BOTTOM OF DRAINFIELD IN RELATION TO EXISTING GRADE �i INCHES '[ABOVE/BELOW-]
SYSTEM FAILURE AND REPAIR INFORMATION
[ ] SYSTEM INSTALLATION DATE TYPE OF WASTE [ ] DOMESTIC [ ] COMMERCIAL
[ ] GPD ESTIMATED SEWAGE FLOW BASED ON I ] METERED WATER j ] TABLE 1, 64E-6, PAC
SITE [ ] DRAINAGE STRUCTURES [ ] POOL [ ] PATIO / DECK [ ] PARKING
CONDITIONS: [ ] SLOPING PROPERTY [ ]
NATURE OF [ ] HYDRAULIC: OVERLOAD [ ] SOILS [ ] MAINTENANCE [ ] SYSTEM DAMAGE
FAILURE': [ ] DRAINAGE / RUN OFF ( ] ROOTS [ ] WATER TABLE [ ]
FAILURE [ ] SEWAGE ON GROUND EX TANK [. ] D BOX/HEADER [;,C] DRAINFIELD
SYMPTOM: [ ] PLUMBING BACKUP I>ejn 4 �O'C. ; n. %� G;,%y1tJ(7�1 (�►'��y,
REMARKS/ADDITIONAL CRITERIA
SUBMITTED BY: TITLE/LICENSE DATE:
DH 4015, 08/09,(Obsoletes previous editions which may not be used)
Incorporated 64E-6.001, FAC Page 4 of 4
https://sl .ebridge.com/ebridge/3.0/webviewerNiewer.aspx?ref=dkk5Ki7Exi%2fNvpTQt3gTLoOX... 4/23/2021
eBridg@ Web Viewer
Page 8of9
INSTRUCTIONS:
PERMIT N
Permit tracking number assigned by department
APPLICANT
Property owner's full name
CONTRACTOR/AGENT
Licensed contractor or property owner's legal agent
LOT,BLOCK,SUBDIVISION
Legal description for property
ID N
Property appraiser identification number for property
EXISTING TANK
TANK 1
Complete tank size in gallons or gpd and mark appropriately.
Complete LEGEND (SHO approval number), MATERIAL (concrete, fiberglass,
polyethylene) and whether or not tank in BAFFLED.
TANK 2
Same as TANK 1.
GREASE INTERCEPTOR Same as TANK 1.
DOSING TANK
Same as TANK 1. Complete a# PUMPS installed.
TANK CERTIFICATION
Completed by registered septic tank contractor, state -licensed plumber, certified EH
professional, or master septic tank contractor. Show the date the tanks were pumped, the
name of the pumping company, how the tank volumes were determined (measurement of
tank dimensions and calculation of volume, filling the tank from a metered water source,
or recording the tank legend for known tanks). if tank dimensions are used, list the tank
dimensions in the remarks section. Indicate whether the tank has a solids deflection
device or an outletlet filter. If the tanks cannot be certified, note that fact in the remarks
section.
EXISTING DRAINFIELD
FIELD l
Complete size of drainfield in square feet, NO. OF TRENCHES (if applicable) and
DIMENSION (bed width and length or trench width and total length of trenches).
FIELD 2
Same as FIELD I
TYPE OF SYSTEM
Mark appropriate block
CONFIGURATION
Mark appropriate block
DESIGN
Mark appropriate blocks
ELEVATION
Record elevation of lowest point of bottom of drainfield in reference to natural grade
FAILURE / REPAIR INFORMATION
INSTALLATION DATE
Record year of original system installation
TYPE OF WASTE
Mark appropriate block
GPD
Provide estimated sewage flow to system based on metered water flow data (if available)
or Table 1, whichever is greater.
SITE CONDITIONS
Mark all applicable blocks. Record any other significant conditions.
NATURE OF FAILURE
Mark all applicable blocks.
FAILURE SYMPTOM
Mark all applicable blocks.
REMARKS
Record any other significant criteria that may impact system design. If dimensions are
used to determine tank volumes, list the tank dimensions in the remarks section. If the
tanks cannot be certified as tree of observable defects or leaks, explain in remarks.
SUBMITTED BY
Signature of person performing evaluation
TITLE/LICENSE
Title of department person or license number of other evaluators.
DATE
Date of evaluation.
hftps:Hsl .ebridge.com/ebridge/3.0/webviewerNiewer.aspx?ref=dkk5Ki7Exi%2fNvpTQt3gTLoOX... 4/23/2021
eBridge Web Viewer
Page 9of9
Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved.
Property Identification
Site Address: 1.901 S, 33rd ST Parcel ID: 2417-702-0048- Account 9::27021 SeclTown/Range: 17/35S/40E
000-9 Map ID: 24/17S Zoning: RM-5 - Cou
Use Type: 0100 Jurisdiction: Saint Lucie
County
Ownership Legal Description -
Alex Hensley WESTWOOD MANOR BLK 3'LOTS 22 TO 24 INCL (0.48 AC)
2108 S 33rd ST
Fort Pierce, FL 34947
Current Values
Historical Values 3-year
Just/Market:
S62,806 Assessed:
S62,800
Year
Just/Market Assessed Exemptions
Taxable
Exemptions:
SO Taxable:
S62,800
2020
$62,800 $62,800
$0
S62,800
2619
S630,600 $34,405
to
S34;405,
2018
S58200 $31,278. SO
S31,278
Sale History
Date
Book/Page
Sale Code
Deed Grantor
Price
09-27-2019
4327 / 1.496
0001
WD Skinner Bretton K
S18,000
09-18-2009
3132 / 1436
0111
QC Ketcham Brenda H
$!00
03-21-2007
2785 / 0162
XX01
QC Skinner 11 Robert G
S100
Primary Building Information
Finished Area of this building: 912.SF
Gross Sketched Area: 1,432 SF
View: Roof Cover. Metal
Year Built: 1940 Frame:
Primary Walk Abs Shingle Story Height: 1 Story
Bedrooms: 2
Full Baths: I
Half Baths: 0
A/C %: 0%
Heated %: 0%
Sprinkled %: N/A%o
rani
Exterior Data
Roof Structure: Gable
Grade: D
No. Units: 1
Interior Data
Electric: AVERAGE
Heat Type:
Heat Fuel:
Total Areas
Building Type: HD
Effective Year. 1965
Secondary Wall:
Primary Int Wall:
Avg Hgt1Floor: 0
Primary Floors: Double Pine
Finished/UnderAir 912
(SF):
Gross Sketched Area 1,432
(SF):
Land Size (acres): 0.48
Land Size (SF): 20,908.8
Total Building Count: 1
-Special Features and Yard items
Type Qty Units Year BIt
WOOD FEN 6' 1 73 1999
All information is believed to be correct at. this time, but is subject t9 change and is provided without any warranty.
( Copyright 2021 Saint.Lucie County Property Appraiser. All rights reserved.
https://s1.ebridge.com/ebridge/3.0/webviewerNiewer.aspx?ref=dkk5Ki7Exi%2fNvpTQt3gTLoOX... 4/23/2021