HomeMy WebLinkAboutAPPROVED, Truss - Royale6904 Parke East Blvd. Tampa, FL 33610-4115 MiTek USA, Inc. RE: m11324 - THE ROYALE Design Code: FBC2017/TPI2014 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Design Program: MiTek 20/20 8.1 1 of 1 This package includes 27 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Floor Load: N/A psf Site Information: Lot/Block: Customer Info: WYNNE BUILDING CORPORATION Project Name: ROYALE Model: ROYALE Subdivision: Address: UNKNOWN State: FLCity: ST LUCIE Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: February 5,2021 ORegan, Philip The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Chambers Truss. Truss Design Engineer's Name: ORegan, Philip My license renewal date for the state of Florida is February 28, 2023. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. No.Seal#Truss Name 1 T22730705 A Date 2/5/212T22730706A12/5/213T22730707A22/5/214T22730708A32/5/215T22730709A42/5/216T22730710A62/5/217T22730711B2/5/218T22730712BH72/5/219T22730713GRA2/5/2110T22730714GRB2/5/2111T22730715GRC2/5/2112T22730716J12/5/2113T22730717J22/5/2114T22730718J32/5/21 No.Seal#Truss Name 15 T22730719 J4 Date 2/5/2116T22730720J52/5/2117T22730721J62/5/2118T22730722J82/5/2119T22730723JA2/5/2120T22730724JB2/5/2121T22730725JC2/5/2122T22730726KJ52/5/2123T22730727KJ82/5/2124T22730728KJA2/5/2125T22730729KJB2/5/2126T22730730MV22/5/2127T22730731MV42/5/21 This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss A Truss Type COMMON Qty 10 Ply 1 THE ROYALE Job Reference (optional) T22730705 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:26 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-F1JZ2IqpHSvnS07KLQlYXGuiemJgY1kvEQRo?FzoWfN Scale = 1:59.3 1 2 3 4 5 6 7 8 9 10 11 17 16 15 14 13 12 24 25 26 27 28 29 3x6 4x5 3x6 4x5 5x6 WB 2x3 3x8 3x4 2x3 2x3 3x8 3x4 2x3 5x6 WB 4x5 8-4-0 8-4-0 12-11-0 4-7-0 22-1-0 9-2-0 26-8-0 4-7-0 35-0-0 8-4-0 -1-0-0 1-0-0 8-4-0 8-4-0 12-11-0 4-7-0 17-6-0 4-7-0 22-1-0 4-7-0 26-8-0 4-7-0 35-0-0 8-4-0 36-0-0 1-0-0 0-3-156-1-150-3-154.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MS 0.59 0.68 0.63 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.33 -0.64 0.13 (loc) 14-15 14-15 10 l/defl >999 >652 n/a L/d 360 240 n/a PLATES MT20 Weight: 169 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-10-7 oc bracing. REACTIONS.(lb/size)2=1399/0-8-0, 10=1399/0-8-0 Max Horz 2=-223(LC 8) Max Uplift 2=-775(LC 10), 10=-775(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3404/2226, 3-5=-2807/1885, 5-6=-2801/1990, 6-7=-2801/1990, 7-9=-2807/1885, 9-10=-3404/2226 BOT CHORD 2-17=-1946/3218, 15-17=-1946/3218, 14-15=-1116/2053, 12-14=-1946/3188, 10-12=-1946/3188 WEBS 6-14=-598/1034, 7-14=-252/246, 9-14=-702/541, 6-15=-598/1035, 5-15=-253/246, 3-15=-701/541 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 12-8-6, Exterior(2) 12-8-6 to 17-6-0, Interior(1) 22-1-0 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) 100.0lb AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift at joint 2 and 775 lb uplift at joint 10. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss A1 Truss Type SPECIAL Qty 9 Ply 1 THE ROYALE Job Reference (optional) T22730706 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:27 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-jDtxGerR2m1e3AiWu7Gn4TRpkAboHUA2T4AMXhzoWfM Scale = 1:60.3 1 2 3 4 5 6 7 8 9 10 11 14 13 12 21 22 23 24 25 26 3x6 5x8 MT18HS 5x6 WB 3x5 5x12 3x12 3x4 2x3 2x3 2x3 6x10 MT18HS 2x3 7-8-0 7-8-0 13-7-8 5-11-8 23-11-12 10-4-4 35-0-0 11-0-4 -1-0-0 1-0-0 7-8-0 7-8-0 13-7-8 5-11-8 17-6-0 3-10-8 23-11-12 6-5-12 26-9-10 2-9-14 35-0-0 8-2-6 36-0-0 1-0-0 0-3-156-1-150-3-151-8-114.00 12 2.00 12 Plate Offsets (X,Y)-- [2:0-1-2,Edge], [8:0-3-0,Edge], [10:0-1-15,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MS 0.89 0.94 0.62 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.80 -1.39 0.37 (loc) 12 12-13 10 l/defl >525 >302 n/a L/d 360 240 n/a PLATES MT20 MT18HS Weight: 159 lb FT = 0% GRIP 244/190 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 6-12: 2x4 SP M 30 OTHERS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 6-12 REACTIONS.(lb/size)2=1349/0-8-0, 10=1349/0-8-0 Max Horz 2=-223(LC 8) Max Uplift 2=-825(LC 10), 10=-825(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3309/2433, 3-5=-2581/2012, 5-6=-2548/2113, 6-7=-5337/4002, 7-9=-5302/3868, 9-10=-5702/4143 BOT CHORD 2-14=-2151/3113, 13-14=-2151/3113, 12-13=-1450/2202, 10-12=-3809/5431 WEBS 3-14=0/265, 3-13=-813/590, 5-13=-269/317, 6-13=-317/567, 6-12=-2362/3388, 7-12=-298/368, 9-12=-405/352 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 12-8-6, Exterior(2) 12-8-6 to 17-6-0, Interior(1) 22-3-10 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 10. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss A2 Truss Type SPECIAL Qty 1 Ply 1 THE ROYALE Job Reference (optional) T22730707 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:28 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-CPRJT_s3p49VhKHiSrn0chz1NawW0vPChkwv47zoWfL Scale = 1:62.3 1 2 3 4 5 6 7 8 9 10 11 15 14 13 12 22 23 5x10 5x6 4x4 5x6 3x5 5x6 3x12 2x3 3x10 3x8 6x10 MT18HS 8-0-1 8-0-1 13-7-8 5-7-7 19-0-0 5-4-8 23-11-12 4-11-12 35-0-0 11-0-4 -1-0-0 1-0-0 8-0-1 8-0-1 13-7-8 5-7-7 16-0-0 2-4-8 19-0-0 3-0-0 23-11-12 4-11-12 26-9-9 2-9-13 35-0-0 8-2-7 36-0-0 1-0-0 0-3-155-7-150-3-151-8-115-7-154.00 12 2.00 12 Plate Offsets (X,Y)-- [2:0-1-2,Edge], [4:0-2-12,0-3-0], [4:0-0-0,0-1-12], [8:0-3-0,Edge], [8:0-0-0,0-1-12], [9:0-3-2,0-0-0], [10:0-1-15,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MS 0.70 0.98 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.75 -1.02 0.37 (loc) 12 12-21 10 l/defl >559 >412 n/a L/d 360 240 n/a PLATES MT20 MT18HS Weight: 160 lb FT = 0% GRIP 244/190 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 7-13 REACTIONS.(lb/size)2=1349/0-8-0, 10=1349/0-8-0 Max Horz 2=-205(LC 8) Max Uplift 2=-825(LC 10), 10=-825(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3315/2113, 3-5=-2515/1641, 5-6=-2524/1699, 6-7=-2672/1734, 7-9=-5246/3199, 9-10=-5687/3567 BOT CHORD 2-15=-1849/3111, 14-15=-1849/3111, 13-14=-1217/2314, 12-13=-2804/5025, 10-12=-3257/5414 WEBS 3-15=0/300, 3-14=-954/692, 5-13=-206/561, 6-13=-357/632, 7-13=-2796/1678, 7-12=-1082/1957, 9-12=-479/463 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 10. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss A3 Truss Type SPECIAL Qty 1 Ply 1 THE ROYALE Job Reference (optional) T22730708 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:29 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-gc?ihJthaNHLJUsv0YJF9uWCN_GllMiLwOfScazoWfK Scale = 1:61.3 1 2 3 4 5 6 7 8 9 13 12 11 10 20 21 4x6 3x5 5x6 3x12 3x4 2x3 5x6 3x8 3x8 6x10 MT18HS 2x3 8-0-1 8-0-1 13-7-8 5-7-7 21-0-0 7-4-8 23-11-12 2-11-12 35-0-0 11-0-4 -1-0-0 1-0-0 8-0-1 8-0-1 14-0-0 5-11-15 21-0-0 7-0-0 23-11-12 2-11-12 26-9-10 2-9-14 35-0-0 8-2-6 36-0-0 1-0-0 0-3-154-11-150-3-151-8-114-11-154.00 12 2.00 12 Plate Offsets (X,Y)-- [2:0-1-2,Edge], [8:0-1-15,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MS 0.69 0.98 0.74 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.72 -0.98 0.35 (loc) 10 10-19 8 l/defl >582 >427 n/a L/d 360 240 n/a PLATES MT20 MT18HS Weight: 158 lb FT = 0% GRIP 244/190 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-5-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS.(lb/size)2=1349/0-8-0, 8=1349/0-8-0 Max Horz 2=-181(LC 8) Max Uplift 2=-825(LC 10), 8=-825(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3286/2122, 3-4=-2556/1711, 4-5=-3161/2095, 5-6=-3304/2150, 6-7=-5214/3232, 7-8=-5695/3643 BOT CHORD 2-13=-1853/3079, 12-13=-1853/3079, 11-12=-1338/2410, 10-11=-2826/4982, 8-10=-3331/5422 WEBS 3-13=0/293, 3-12=-854/595, 4-11=-480/959, 5-11=-360/724, 6-11=-2280/1355, 6-10=-1118/1934, 7-10=-530/515 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 8. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss A4 Truss Type SPECIAL Qty 1 Ply 1 THE ROYALE Job Reference (optional) T22730709 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:31 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-c_7S6?ux6?X3Yn0H7zLjEJbX4nxPDFoeOi8ZhSzoWfI Scale = 1:61.3 1 2 3 4 5 6 7 8 9 10 14 13 12 11 21 22 5x6 5x8 3x6 5x6 3x12 3x4 2x3 3x4 3x4 2x3 6x10 MT18HS 2x3 8-8-2 8-8-2 13-7-8 4-11-6 17-6-0 3-10-8 23-11-12 6-5-12 35-0-0 11-0-4 -1-0-0 1-0-0 6-5-8 6-5-8 12-0-0 5-6-8 17-8-4 5-8-4 23-0-0 5-3-12 23-11-12 0-11-12 26-9-9 2-9-13 35-0-0 8-2-7 36-0-0 1-0-0 0-3-154-3-150-3-151-8-114-3-154.00 12 2.00 12 Plate Offsets (X,Y)-- [2:0-0-6,Edge], [6:0-4-0,0-2-3], [9:0-1-15,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MS 0.67 0.96 0.77 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.73 -0.98 0.36 (loc) 11-12 11-20 9 l/defl >572 >429 n/a L/d 360 240 n/a PLATES MT20 MT18HS Weight: 160 lb FT = 0% GRIP 244/190 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-5-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS.(lb/size)2=1349/0-8-0, 9=1349/0-8-0 Max Horz 2=157(LC 9) Max Uplift 2=-825(LC 10), 9=-825(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3367/2256, 3-4=-3093/2069, 4-5=-2645/1853, 5-6=-3425/2347, 6-7=-5165/3301, 7-8=-5219/3301, 8-9=-5704/3714 BOT CHORD 2-14=-2000/3170, 13-14=-1488/2537, 12-13=-2065/3480, 11-12=-2440/4196, 9-11=-3399/5431 WEBS 3-14=-429/415, 4-14=-323/584, 4-13=-142/386, 5-13=-1125/697, 5-12=-141/467, 6-12=-861/437, 6-11=-1145/2016, 8-11=-542/518 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 9. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss A6 Truss Type HIP Qty 1 Ply 1 THE ROYALE Job Reference (optional) T22730710 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:32 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-4BhqJLvZtIfwAxaUhgsynX8hBBLZyqAocMu7DuzoWfH Scale = 1:60.3 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 23 24 25 26 27 28 5x8 5x8 4x5 4x6 3x4 2x3 3x4 2x3 2x3 3x4 3x4 2x3 4x6 4x5 10-0-0 10-0-0 13-8-0 3-8-0 21-4-0 7-8-0 25-0-0 3-8-0 35-0-0 10-0-0 -1-0-0 1-0-0 6-7-15 6-7-15 10-0-0 3-4-1 13-8-0 3-8-0 21-4-0 7-8-0 25-0-0 3-8-0 28-4-1 3-4-1 35-0-0 6-7-15 36-0-0 1-0-0 0-3-153-7-150-3-153-7-154.00 12 Plate Offsets (X,Y)-- [2:0-1-14,Edge], [4:0-5-4,0-2-8], [7:0-5-4,0-2-8], [9:0-1-14,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MS 0.71 0.71 0.31 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.60 -0.78 0.11 (loc) 11-13 13 9 l/defl >424 >328 n/a L/d 360 240 n/a PLATES MT20 Weight: 153 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-6-3 oc bracing. REACTIONS.(lb/size)2=1118/0-8-0, 14=379/0-8-0, 9=1201/0-8-0 Max Horz 2=-133(LC 8) Max Uplift 2=-692(LC 10), 14=-219(LC 10), 9=-739(LC 10) Max Grav 2=1118(LC 1), 14=454(LC 19), 9=1206(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2600/2341, 3-4=-2215/1960, 4-5=-2527/2290, 5-6=-2527/2290, 6-7=-2527/2290, 7-8=-2531/2224, 8-9=-2880/2572 BOT CHORD 2-16=-2074/2444, 14-16=-1569/2065, 13-14=-1968/2527, 11-13=-1833/2382, 9-11=-2290/2707 WEBS 3-16=-495/599, 4-16=-206/347, 4-14=-541/820, 5-14=-526/591, 6-13=-234/311, 7-13=-182/282, 7-11=-355/492, 8-11=-444/551 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 16-9-7, Interior(1) 16-9-7 to 18-2-9, Exterior(2) 18-2-9 to 25-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 692 lb uplift at joint 2, 219 lb uplift at joint 14 and 739 lb uplift at joint 9. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss B Truss Type COMMON Qty 3 Ply 1 THE ROYALE Job Reference (optional) T22730711 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:33 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-YNECWhwCdcnno59gFONBJkhyKbnrhKRxr0dglLzoWfG Scale: 1/2"=1' 1 2 3 4 5 3x4 3x4 2x3 4x6 6-11-0 6-11-0 13-10-0 6-11-0 -1-0-0 1-0-0 6-11-0 6-11-0 13-10-0 6-11-0 0-3-152-7-100-3-154.00 12 Plate Offsets (X,Y)-- [2:0-2-10,Edge], [4:0-2-10,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MS 0.37 0.33 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.10 -0.13 0.01 (loc) 5-8 5-8 4 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 47 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-7-1 oc bracing. REACTIONS.(lb/size)4=510/0-8-0, 2=568/0-8-0 Max Horz 2=93(LC 9) Max Uplift 4=-292(LC 10), 2=-377(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-967/954, 3-4=-966/952 BOT CHORD 2-5=-785/883, 4-5=-785/883 WEBS 3-5=-84/315 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 292 lb uplift at joint 4 and 377 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss BH7 Truss Type BOSTON HIP Qty 1 Ply 1 THE ROYALE Job Reference (optional) T22730712 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:34 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-0Zobk1wqOwvePFksp5uQsyD1Z?4OQh344gNDHnzoWfF Scale = 1:62.6 1 2 3 4 6 8 9 12 14 16 19 22 24 26 27 28 29 5 7 10 11 13 15 17 18 20 21 23 25 35 34 33 32 31 30 42 43 44 45 3x5 4x6 3x6 5x6 3x6 5x12 5x6 5x12 3x8 3x4 3x4 4x6 3x6 7-0-0 7-0-0 14-0-0 7-0-0 21-0-0 7-0-0 28-0-0 7-0-0 35-0-0 7-0-0 -1-0-0 1-0-0 7-0-0 7-0-0 9-6-0 2-6-0 11-6-0 2-0-0 13-6-0 2-0-0 14-0-0 0-6-0 15-6-0 1-6-0 17-6-0 2-0-0 19-6-0 2-0-0 21-0-0 1-6-0 21-6-0 0-6-0 23-6-0 2-0-0 25-6-0 2-0-0 28-0-0 2-6-0 35-0-0 7-0-0 36-0-0 1-0-0 0-3-152-7-156-1-150-3-152-7-154.00 12 Plate Offsets (X,Y)-- [2:0-1-2,Edge], [28:0-0-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MS 0.72 0.56 0.48 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.51 -0.67 0.14 (loc) 32-33 32-33 28 l/defl >826 >628 n/a L/d 360 240 n/a PLATES MT20 Weight: 208 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-6-1 oc bracing. JOINTS 1 Brace at Jt(s): 11, 18, 15, 7, 23 REACTIONS.(lb/size)2=1349/0-8-0, 28=1349/0-8-0 Max Horz 2=-223(LC 8) Max Uplift 2=-825(LC 10), 28=-825(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3392/2640, 3-4=-1213/956, 4-8=-1157/946, 8-9=-1145/979, 9-12=-1122/1028, 12-14=-1125/1090, 14-16=-1124/1089, 16-19=-1121/1028, 19-22=-1145/979, 22-26=-1157/946, 26-27=-1214/956, 27-28=-3393/2641, 3-5=-2373/2046, 5-7=-2376/2050, 7-10=-2376/2050, 10-11=-2376/2050, 11-13=-2376/2050, 13-15=-2376/2050, 15-17=-2376/2050, 17-18=-2376/2050, 18-20=-2368/2046, 20-23=-2368/2046, 23-25=-2368/2046, 25-27=-2364/2041 BOT CHORD 2-35=-2358/3190, 33-35=-2360/3166, 32-33=-2652/3448, 30-32=-2361/3167, 28-30=-2358/3191 WEBS 3-35=0/284, 27-30=0/285, 3-33=-317/378, 18-33=-466/474, 27-32=-312/353, 14-15=-405/437 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 10-8-9, Exterior(2) 10-8-9 to 17-6-0, Interior(1) 24-3-7 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 28. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. TOP CHORD MUST BE BRACED BY END JACKS, ROOF DIAPHRAGM, OR PROPERLY CONNECTED PURLINS AS SPECIFIED. TRUSS DESIGNED FOR WIND LOADS IN THE PLANE OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND (NORMAL TO THE FACE), SEE STANDARD INDUSTRY GABLE END DETAILS AS APPLICABLE, OR CONSULT QUALIFIED BUILDING DESIGNER AS PER ANSI/TPI 1. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss GRA Truss Type SPECIAL Qty 1 Ply 1 THE ROYALE Job Reference (optional) T22730713 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:36 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-zywL9jy4wX9MfZuFwWxuxNJWVopiui3NX_sKMgzoWfD Scale = 1:26.6 1 2 3 4 5 6 7 8 12 11 10 9 19 20 21 22 23 24 4x10 4x4 4x4 4x10 3x4 3x4 2x3 3x4 3x4 2x3 4-1-8 4-1-8 5-7-3 1-5-11 8-2-13 2-7-9 9-8-8 1-5-11 13-10-0 4-1-8 -1-0-0 1-0-0 4-1-8 4-1-8 5-7-3 1-5-11 8-2-13 2-7-9 9-8-8 1-5-11 13-10-0 4-1-8 14-10-0 1-0-0 0-3-151-8-71-11-150-3-151-11-154.00 12 2.37 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-MS 0.18 0.32 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.08 -0.10 0.03 (loc) 11 10 7 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 58 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-0-4 oc bracing. REACTIONS.(lb/size)2=770/0-8-0, 7=770/0-8-0 Max Horz 2=-65(LC 6) Max Uplift 2=-523(LC 8), 7=-523(LC 8) Max Grav 2=787(LC 17), 7=787(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1798/1192, 3-4=-1761/1197, 4-5=-1724/1169, 5-6=-1761/1190, 6-7=-1798/1137 BOT CHORD 2-12=-1083/1685, 11-12=-1082/1692, 10-11=-1112/1724, 9-10=-1024/1692, 7-9=-1028/1685 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 523 lb uplift at joint 2 and 523 lb uplift at joint 7. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 63 lb down and 114 lb up at 4-1-8, 85 lb down and 124 lb up at 5-0-0, 113 lb down and 146 lb up at 5-7-3, 60 lb down and 129 lb up at 5-11-0, 60 lb down and 129 lb up at 7-11-0, 113 lb down and 146 lb up at 8-2-13, and 85 lb down and 124 lb up at 8-10-0, and 63 lb down and 139 lb up at 9-8-8 on top chord, and 6 lb down and 7 lb up at 4-1-8, 18 lb down and 15 lb up at 5-0-0, 33 lb down at 5-7-3, 39 lb down at 5-11-0 , 39 lb down at 7-11-0, 33 lb down at 8-2-13, and 18 lb down and 15 lb up at 8-10-0, and 6 lb down and 7 lb up at 9-8-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-4=-54, 4-5=-54, 5-6=-54, 6-8=-54, 13-16=-20 Concentrated Loads (lb) Vert: 3=7(B) 4=-64(B) 5=-64(B) 6=7(B) 12=-6(B) 11=-35(B) 10=-35(B) 9=-6(B) 19=-28(B) 20=-60(B) 21=-60(B) 22=-28(B) 23=-18(B) 24=-18(B) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss GRB Truss Type SPECIAL Qty 1 Ply 1 THE ROYALE Job Reference (optional) T22730714 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:37 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-R8UjM2zihrHDGiTRUDS7UardkC8?d1xXmebuu6zoWfC Scale = 1:62.4 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 4x8 3x6 4x4 4x4 3x4 3x6 2x3 3x4 3x4 5x6 2x3 2x3 3x4 3x4 3x6 3x4 5-0-0 5-0-0 10-3-0 5-3-0 15-6-0 5-3-0 21-6-0 6-0-0 28-1-0 6-7-0 35-0-0 6-11-0 -1-0-0 1-0-0 5-0-0 5-0-0 10-3-0 5-3-0 15-6-0 5-3-0 21-6-0 6-0-0 26-2-0 4-8-0 28-1-0 1-11-0 35-0-0 6-11-0 36-0-0 1-0-0 0-3-151-11-152-7-100-3-151-11-154.00 12 Plate Offsets (X,Y)-- [3:0-5-4,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-MS 0.41 0.38 0.53 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.11 -0.14 0.03 (loc) 17-18 17-18 10 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 146 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-15 REACTIONS.All bearings 0-8-0. (lb) - Max Horz 2=96(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 2=-536(LC 8), 15=-846(LC 8), 14=-555(LC 8), 10=-314(LC 8) Max Grav All reactions 250 lb or less at joint(s) except 2=787(LC 17), 15=1322(LC 1), 14=927(LC 1), 10=506(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1773/1106, 3-4=-1406/944, 4-6=-304/595, 6-7=-304/595, 7-8=-304/595, 8-9=-702/344, 9-10=-719/323 BOT CHORD 2-18=-962/1659, 17-18=-958/1675, 15-17=-843/1406, 14-15=-595/429, 12-14=-158/622, 10-12=-196/636 WEBS 3-18=0/331, 3-17=-297/158, 4-17=0/362, 4-15=-2076/1313, 6-15=-505/480, 7-14=-431/408, 8-14=-1063/625, 8-12=-115/265 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 536 lb uplift at joint 2, 846 lb uplift at joint 15, 555 lb uplift at joint 14 and 314 lb uplift at joint 10. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 257 lb down and 341 lb up at 5-0-0, 100 lb down and 129 lb up at 7-0-12, 100 lb down and 129 lb up at 9-0-12, 100 lb down and 129 lb up at 11-0-12, 100 lb down and 129 lb up at 13-0-12, 100 lb down and 129 lb up at 15-0-12, 100 lb down and 129 lb up at 17-0-12, and 100 lb down and 129 lb up at 19-0-12, and 100 lb down and 129 lb up at 21-1-4 on top chord, and 83 lb down at 5-0-0, 39 lb down at 7-0-12, 39 lb down at 9-0-12, 39 lb down at 11-0-12, 39 lb down at 13-0-12, 39 lb down at 15-0-12, 39 lb down at 17-0-12, and 39 lb down at 19-0-12, and 39 lb down at 21-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Continued on page 2 This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss GRB Truss Type SPECIAL Qty 1 Ply 1 THE ROYALE Job Reference (optional) T22730714 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:37 2021 Page 2 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-R8UjM2zihrHDGiTRUDS7UardkC8?d1xXmebuu6zoWfC LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-54, 8-9=-54, 9-11=-54, 19-22=-20 Concentrated Loads (lb) Vert: 3=-160(F) 18=-45(F) 25=-60(F) 26=-60(F) 27=-60(F) 29=-60(F) 30=-60(F) 31=-60(F) 32=-60(F) 33=-60(F) 36=-13(F) 37=-13(F) 38=-13(F) 39=-13(F) 40=-13(F) 41=-13(F) 42=-13(F) 43=-13(F) Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss GRC Truss Type HIP Qty 1 Ply 1 THE ROYALE Job Reference (optional) T22730715 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:39 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-NXcUnk_yDSXxW0dqbeUbZ?wuR0ls5tPpDy4_z?zoWfA Scale = 1:60.3 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 5x8 MT18HS 3x6 5x8 MT18HS 3x5 3x6 2x3 6x10 2x3 3x8 2x3 6x10 2x3 3x6 3x5 8-0-0 8-0-0 13-8-0 5-8-0 21-4-0 7-8-0 27-0-0 5-8-0 35-0-0 8-0-0 -1-0-0 1-0-0 8-0-0 8-0-0 13-8-0 5-8-0 17-6-0 3-10-0 21-4-0 3-10-0 27-0-0 5-8-0 35-0-0 8-0-0 36-0-0 1-0-0 0-3-152-11-150-3-152-11-154.00 12 Plate Offsets (X,Y)-- [3:0-5-4,0-2-8], [8:0-5-4,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-MS 0.71 0.67 0.79 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.22 -0.31 0.05 (loc) 11-22 13-14 9 l/defl >999 >830 n/a L/d 360 240 n/a PLATES MT20 MT18HS Weight: 157 lb FT = 0% GRIP 244/190 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 4-14,7-13: 2x6 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-9-3 oc bracing. WEBS 1 Row at midpt 3-14, 5-14 REACTIONS.(lb/size)2=412/0-8-0, 14=3582/0-8-0, 9=1192/0-8-0 Max Horz 2=-109(LC 6) Max Uplift 2=-299(LC 8), 14=-2133(LC 8), 9=-764(LC 8) Max Grav 2=423(LC 17), 14=3582(LC 1), 9=1194(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-377/225, 3-4=-1093/1954, 4-5=-1093/1954, 5-7=-1943/1220, 7-8=-1943/1220, 8-9=-2776/1671 BOT CHORD 2-16=-154/317, 14-16=-160/350, 11-13=-1475/2624, 9-11=-1464/2591 WEBS 3-16=-200/679, 3-14=-2514/1528, 4-14=-641/586, 5-14=-2674/1707, 5-13=-1124/2080, 7-13=-592/548, 8-13=-760/483, 8-11=-201/684 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 299 lb uplift at joint 2, 2133 lb uplift at joint 14 and 764 lb uplift at joint 9. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 182 lb down and 312 lb up at 8-0-0, 107 lb down and 173 lb up at 10-0-12, 107 lb down and 173 lb up at 12-0-12, 107 lb down and 173 lb up at 14-0-12, 107 lb down and 173 lb up at 16-0-12, 107 lb down and 173 lb up at 16-11-4, 107 lb down and 173 lb up at 18-11-4, 107 lb down and 173 lb up at 20-11-4, 107 lb down and 173 lb up at 22-11-4, and 107 lb down and 173 lb up at 24-11-4, and 182 lb down and 312 lb up at 27-0-0 on top chord, and 411 lb down and 242 lb up at 8-0-0, 79 lb down and 1 lb up at 10-0-12, 79 lb down and 1 lb up at 12-0-12, 79 lb down and 1 lb up at 14-0-12, 79 lb down and 1 lb up at 16-0-12, 79 lb down and 1 lb up at 16-11-4, 79 lb down and 1 lb up at 18-11-4, 79 lb down and 1 lb up at 20-11-4, 79 lb down and 1 lb up at 22-11-4, and 79 lb down and 1 lb up at 24-11-4, and 411 lb down and 242 lb up at 26-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Continued on page 2 This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss GRC Truss Type HIP Qty 1 Ply 1 THE ROYALE Job Reference (optional) T22730715 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:39 2021 Page 2 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-NXcUnk_yDSXxW0dqbeUbZ?wuR0ls5tPpDy4_z?zoWfA LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-54, 8-10=-54, 17-20=-20 Concentrated Loads (lb) Vert: 3=-126(B) 6=-107(B) 8=-126(B) 15=-50(B) 16=-411(B) 11=-411(B) 12=-50(B) 23=-107(B) 25=-107(B) 26=-107(B) 27=-107(B) 28=-107(B) 29=-107(B) 30=-107(B) 32=-107(B) 33=-50(B) 34=-50(B) 35=-50(B) 36=-50(B) 37=-50(B) 38=-50(B) 39=-50(B) Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss J1 Truss Type MONO TRUSS Qty 2 Ply 1 THE ROYALE Job Reference (optional) T22730716 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:39 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-NXcUnk_yDSXxW0dqbeUbZ?w1p0v353npDy4_z?zoWfA Scale = 1:6.1 1 2 3 4 3x4 1-0-0 1-0-0 -1-0-0 1-0-0 1-0-0 1-0-0 0-3-150-7-154.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MP 0.18 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 5 5 4 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 5 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=9/Mechanical, 2=118/0-8-0, 4=0/Mechanical Max Horz 2=48(LC 10) Max Uplift 3=-4(LC 7), 2=-140(LC 10) Max Grav 3=11(LC 15), 2=118(LC 1), 4=17(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss J2 Truss Type MONO TRUSS Qty 4 Ply 1 THE ROYALE Job Reference (optional) T22730717 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:40 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-rj9s_4?b_mgo7AC09M?q5DTCYQEUqW0zScqYVRzoWf9 Scale = 1:7.8 1 2 3 43x4 2-0-0 2-0-0 -1-0-0 1-0-0 2-0-0 2-0-0 0-3-150-11-150-7-150-11-154.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MP 0.18 0.07 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 7 7 3 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 8 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=37/Mechanical, 2=141/0-8-0, 4=23/Mechanical Max Horz 2=67(LC 10) Max Uplift 3=-28(LC 10), 2=-136(LC 10), 4=-3(LC 7) Max Grav 3=42(LC 15), 2=141(LC 1), 4=31(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 lb uplift at joint 2 and 3 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss J3 Truss Type MONO TRUSS Qty 2 Ply 1 THE ROYALE Job Reference (optional) T22730718 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:41 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-JvjECQ0Dl3oelKnCj3W3eQ0NIpZ9ZzG6hGZ51tzoWf8 Scale = 1:9.4 1 2 3 4 3x4 3-0-0 3-0-0 -1-0-0 1-0-0 3-0-0 3-0-0 0-3-151-3-154.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MP 0.18 0.17 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.01 -0.01 -0.00 (loc) 4-7 4-7 3 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 11 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=64/Mechanical, 2=173/0-8-0, 4=37/Mechanical Max Horz 2=85(LC 10) Max Uplift 3=-54(LC 10), 2=-147(LC 10), 4=-4(LC 10) Max Grav 3=70(LC 15), 2=173(LC 1), 4=50(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint 2 and 4 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss J4 Truss Type MONO TRUSS Qty 4 Ply 1 THE ROYALE Job Reference (optional) T22730719 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:42 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-n6HcPm1rWNwVNULPHn2IBeYUkDsEIPWGwwJeZJzoWf7 Scale = 1:11.1 1 2 3 43x4 4-0-0 4-0-0 -1-0-0 1-0-0 4-0-0 4-0-0 0-3-151-7-151-3-151-7-154.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MP 0.39 0.37 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.02 -0.02 -0.00 (loc) 4-7 4-7 3 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 14 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=89/Mechanical, 2=206/0-8-0, 4=50/Mechanical Max Horz 2=104(LC 10) Max Uplift 3=-79(LC 10), 2=-161(LC 10), 4=-8(LC 10) Max Grav 3=97(LC 15), 2=206(LC 1), 4=67(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 3, 161 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss J5 Truss Type MONO TRUSS Qty 11 Ply 1 THE ROYALE Job Reference (optional) T22730720 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:42 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-n6HcPm1rWNwVNULPHn2IBeYQqDo4IPWGwwJeZJzoWf7 Scale = 1:12.7 1 2 3 4 3x4 5-0-0 5-0-0 -1-0-0 1-0-0 5-0-0 5-0-0 0-3-151-11-154.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MP 0.70 0.64 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.06 -0.06 -0.00 (loc) 4-7 4-7 3 l/defl >939 >964 n/a L/d 360 240 n/a PLATES MT20 Weight: 17 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=115/Mechanical, 2=243/0-8-0, 4=63/Mechanical Max Horz 2=123(LC 10) Max Uplift 3=-104(LC 10), 2=-177(LC 10), 4=-9(LC 10) Max Grav 3=125(LC 15), 2=243(LC 1), 4=87(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at joint 2 and 9 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss J6 Truss Type MONO TRUSS Qty 4 Ply 1 THE ROYALE Job Reference (optional) T22730721 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:43 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-FIr_d61THh2M_dwbqUZXjr5gAd4l1smP8a2C6mzoWf6 Scale = 1:14.6 1 2 3 43x4 6-0-0 6-0-0 -1-0-0 1-0-0 6-0-0 6-0-0 0-3-152-3-154.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MP 0.34 0.80 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.11 -0.11 -0.00 (loc) 4-7 4-7 3 l/defl >664 >652 n/a L/d 360 240 n/a PLATES MT20 Weight: 20 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=142/Mechanical, 2=275/0-8-0, 4=70/Mechanical Max Horz 2=140(LC 10) Max Uplift 3=-129(LC 10), 2=-192(LC 10), 4=-8(LC 10) Max Grav 3=155(LC 15), 2=276(LC 15), 4=100(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 lb uplift at joint 3, 192 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss J8 Truss Type MONO TRUSS Qty 11 Ply 1 THE ROYALE Job Reference (optional) T22730722 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:44 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:kFvnsn0wY4I9ZhO_nM3Ic6yIJ9g-kUPNqS252_ADcnVnOC4mG3enn1V9mJ0ZNEoleCzoWf5 Scale = 1:17.4 1 2 8 3 43x4 7-0-0 7-0-0 8-0-0 1-0-0 -1-0-0 1-0-0 8-0-0 8-0-0 0-3-152-11-154.00 12 Plate Offsets (X,Y)-- [2:0-3-14,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MP 0.61 0.47 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.14 -0.30 -0.00 0.26 (loc) 4-7 4-7 3 4-7 l/defl >676 >310 n/a >368 L/d 360 240 n/a 240 PLATES MT20 Weight: 26 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=188/Mechanical, 2=348/0-8-0, 4=99/Mechanical Max Horz 2=178(LC 12) Max Uplift 3=-174(LC 12), 2=-226(LC 12), 4=-13(LC 12) Max Grav 3=195(LC 17), 2=348(LC 1), 4=141(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(1) 2-7-3 to 7-10-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 3, 226 lb uplift at joint 2 and 13 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss JA Truss Type MONO TRUSS Qty 2 Ply 1 THE ROYALE Job Reference (optional) T22730723 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:44 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-kUPNqS252_ADcnVnOC4mG3euY1b3mJ0ZNEoleCzoWf5 Scale = 1:8.3 1 2 3 43x4 2-4-3 2-4-3 -1-0-0 1-0-0 2-4-3 2-4-3 0-3-151-1-54.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MP 0.18 0.09 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 7 7 3 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 9 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=45/Mechanical, 2=150/0-8-0, 4=28/Mechanical Max Horz 2=73(LC 10) Max Uplift 3=-37(LC 10), 2=-139(LC 10), 4=-4(LC 7) Max Grav 3=50(LC 15), 2=150(LC 1), 4=37(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 37 lb uplift at joint 3, 139 lb uplift at joint 2 and 4 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss JB Truss Type MONO TRUSS Qty 2 Ply 1 THE ROYALE Job Reference (optional) T22730724 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:45 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-Chzl2o3jpII4Ex4_yvb?oGA?2RloVmGicuXJAezoWf4 Scale = 1:12.5 1 2 3 43x4 5-5-11 5-5-11 -1-2-5 1-2-5 5-5-11 5-5-11 0-3-151-10-53.35 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MP 0.38 0.89 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.10 -0.07 -0.00 (loc) 4-7 4-7 3 l/defl >645 >898 n/a L/d 360 240 n/a PLATES MT20 Weight: 19 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-0-0 oc bracing. REACTIONS.(lb/size)3=127/Mechanical, 2=269/0-8-0, 4=63/Mechanical Max Horz 2=114(LC 10) Max Uplift 3=-109(LC 10), 2=-206(LC 10), 4=-6(LC 10) Max Grav 3=127(LC 15), 2=269(LC 1), 4=90(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 109 lb uplift at joint 3, 206 lb uplift at joint 2 and 6 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss JC Truss Type MONO TRUSS Qty 2 Ply 1 THE ROYALE Job Reference (optional) T22730725 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:46 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-gtX7F74LacQxr5fAWc6ELUjD2qIiEDWrqYHsi5zoWf3 Scale = 1:6.2 1 2 3 4 3x4 1-1-4 1-1-4 -1-0-0 1-0-0 1-1-4 1-1-4 0-3-150-8-64.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-MP 0.18 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 5 5 4 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 5 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-1-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=11/Mechanical, 2=119/0-8-0, 4=4/Mechanical Max Horz 2=50(LC 10) Max Uplift 3=-6(LC 7), 2=-138(LC 10) Max Grav 3=14(LC 15), 2=119(LC 1), 4=14(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 6 lb uplift at joint 3 and 138 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss KJ5 Truss Type MONO TRUSS Qty 1 Ply 1 THE ROYALE Job Reference (optional) T22730726 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:47 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-835VST5_KvYoTFEM3KdTuhGLCEa6zgl?3C0PFXzoWf2 Scale = 1:15.7 1 2 3 43x4 7-0-2 7-0-2 -1-5-0 1-5-0 3-11-0 3-11-0 7-0-2 3-1-2 0-3-151-11-122.83 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-MP 0.34 0.26 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.09 -0.15 0.00 (loc) 4-7 4-7 2 l/defl >923 >563 n/a L/d 360 240 n/a PLATES MT20 Weight: 23 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=194/Mechanical, 2=233/0-11-5, 4=94/Mechanical Max Horz 2=109(LC 8) Max Uplift 3=-174(LC 8), 2=-191(LC 8) Max Grav 3=198(LC 13), 2=233(LC 1), 4=133(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 3 and 191 lb uplift at joint 2. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54 Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-to-3=-95(F=-20, B=-20), 5=0(F=10, B=10)-to-4=-35(F=-8, B=-8) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss KJ8 Truss Type MONO TRUSS Qty 2 Ply 1 THE ROYALE Job Reference (optional) T22730727 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:48 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-cGetgp5c5Dgf5PpYd18iQvoYyexWi2X8IsmznzzoWf1 Scale = 1:20.3 1 2 3 6 5 10 11 12 4 13 14 15 3x4 3x4 2x3 3x4 7-2-7 7-2-7 11-0-12 3-10-5 11-3-0 0-2-4 -1-5-0 1-5-0 7-2-7 7-2-7 11-3-0 4-0-9 0-3-152-11-122.83 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-MS 0.21 0.25 0.35 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.08 -0.10 0.01 (loc) 6-9 6-9 5 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 44 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 9-10-15 oc bracing. REACTIONS.(lb/size)4=90/Mechanical, 2=465/0-11-5, 5=409/Mechanical Max Horz 2=178(LC 8) Max Uplift 4=-91(LC 8), 2=-332(LC 8), 5=-223(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-875/541 BOT CHORD 2-6=-535/842, 5-6=-535/842 WEBS 3-6=-1/287, 3-5=-923/587 NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 91 lb uplift at joint 4, 332 lb uplift at joint 2 and 223 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 38 lb down and 61 lb up at 2-11-0, 38 lb down and 61 lb up at 2-11-0, 8 lb down and 106 lb up at 5-8-15, 8 lb down and 106 lb up at 5-8-15, and 42 lb down and 145 lb up at 8-6-14, and 42 lb down and 145 lb up at 8-6-14 on top chord, and 31 lb up at 2-11-0, 31 lb up at 2-11-0, 11 lb down and 31 lb up at 5-8-15, 11 lb down and 31 lb up at 5-8-15, and 31 lb down and 14 lb up at 8-6-14, and 31 lb down and 14 lb up at 8-6-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 5-7=-20 Concentrated Loads (lb) Vert: 10=80(F=40, B=40) 11=-5(F=-3, B=-3) 12=-83(F=-42, B=-42) 13=14(F=7, B=7) 14=-21(F=-11, B=-11) 15=-50(F=-25, B=-25) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss KJA Truss Type MONO TRUSS Qty 2 Ply 1 THE ROYALE Job Reference (optional) T22730728 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:48 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-cGetgp5c5Dgf5PpYd18iQvoY1eyli7?8IsmznzzoWf1 Scale = 1:13.6 1 2 3 43x4 6-0-4 6-0-4 -1-2-9 1-2-9 6-0-4 6-0-4 0-3-151-11-133.30 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-MP 0.21 0.17 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.04 -0.07 0.00 (loc) 4-7 4-7 2 l/defl >999 >974 n/a L/d 360 240 n/a PLATES MT20 Weight: 20 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=142/Mechanical, 2=181/0-9-11, 4=69/Mechanical Max Horz 2=97(LC 8) Max Uplift 3=-129(LC 8), 2=-150(LC 8) Max Grav 3=145(LC 13), 2=181(LC 1), 4=104(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 lb uplift at joint 3 and 150 lb uplift at joint 2. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54 Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-to-3=-81(F=-14, B=-14), 5=0(F=10, B=10)-to-4=-30(F=-5, B=-5) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss KJB Truss Type MONO TRUSS Qty 2 Ply 1 THE ROYALE Job Reference (optional) T22730729 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:49 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-4SCGt96EsXoWiYOlBlgxz6LlL2I7RaFIXVVWJPzoWf0 Scale = 1:11.7 1 2 3 43x4 4-11-9 4-11-9 -1-2-9 1-2-9 4-11-9 4-11-9 0-3-151-8-53.30 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-MP 0.11 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 0.00 (loc) 4-7 4-7 2 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 17 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=95/Mechanical, 2=148/0-9-11, 4=46/Mechanical Max Horz 2=75(LC 8) Max Uplift 3=-84(LC 8), 2=-136(LC 8) Max Grav 3=95(LC 1), 2=148(LC 1), 4=77(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 84 lb uplift at joint 3 and 136 lb uplift at joint 2. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54 Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-to-3=-67(F=-7, B=-7), 5=0(F=10, B=10)-to-4=-25(F=-2, B=-2) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss MV2 Truss Type VALLEY Qty 1 Ply 1 THE ROYALE Job Reference (optional) T22730730 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:50 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-Yeme5V7sdqwNKizxlSBAVKux5SfbA1VRl9F4sszoWf? Scale = 1:6.1 1 2 3 3x4 2-0-0 2-0-0 0-8-04.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 2 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=41/2-0-0, 2=30/2-0-0, 3=11/2-0-0 Max Horz 1=21(LC 10) Max Uplift 1=-20(LC 10), 2=-30(LC 10) Max Grav 1=42(LC 15), 2=32(LC 15), 3=22(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 20 lb uplift at joint 1 and 30 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job M11324 Truss MV4 Truss Type VALLEY Qty 1 Ply 1 THE ROYALE Job Reference (optional) T22730731 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Feb 4 12:21:50 2021 Page 1 Chambers Truss, Inc., Fort Pierce, FL ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-Yeme5V7sdqwNKizxlSBAVKusxSdHA1VRl9F4sszoWf? Scale = 1:9.4 1 2 3 3x4 3x4 3x4 4-0-0 4-0-0 1-4-04.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-P 0.37 0.17 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 0% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=109/4-0-0, 3=109/4-0-0 Max Horz 1=56(LC 10) Max Uplift 1=-54(LC 10), 3=-72(LC 10) Max Grav 1=112(LC 15), 3=117(LC 15) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 1 and 72 lb uplift at joint 3. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. February 5,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths