Loading...
HomeMy WebLinkAboutREVISION, 5.20.21INDEX ABBREVIATIONS ELECTRICAL NOTES VICINITY MAP JURISDICTION NOTES REV BY DATE COMMENTS REV A NAME DATE COMMENTS **** **** **** **** LICENSE GENERAL NOTES 2' FSB 2' FSB2' FS B 2' FS B2' FSB 2' FSB 2' FSB2' FSB2' FSB 2' FS B2' FSB (E) DRIVEWAYPitch5/12MP1Pitch 5/12 MP2Pitch5/12MP3 Scale:1/16" = 1' SITE PLAN 01'32'16' LEGEND MP3 23 153 23 153 Comp Shingle 1 Story MP2 23 243 23 243 Comp Shingle 1 Story MP1 23 63 23 63 Comp Shingle 1 Story #SSTAMPFL #ESTAMPFL NTS TYPICAL PV SIDE VIEWSV Scale: 1 1/2" = 1' STANDOFFS1 #SSTAMPFL #SSTAMPFL LICENSEGENERAL NOTESMAIN PANEL SPECSGROUND SPECS AC Z N EGC L2 L18 X 7 6 L1NEGCL2 POI Z Y X 6 7 8 9 Y 9 #ESTAMPFL LICENSEMODULE SPECS INV 1 INVERTER SPECSGENERAL NOTES INV 2 INV 3 AC DC L2 L1 EGC/ GEC GND 240V Inverter 1 IND EGC DC- DC+ DC- DC+ DC- DC+ A DC- DC+ EGC DC- DC+ EGC DC- DC+ MP 1: 1x9 MP 3: 1x9 MP 2: 1x6 GD A PV 1 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC1 2 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC2 3 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC3 4 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC4 5 Vmp = VAC Imp= AAC 5 #ESTAMPFL CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 222 Ramie Ln OPERATING VOLTAGE = 240V JB-349292-00 LB-130089-10X Per Code: NEC 690.31.G.3 Label Location: (C)(CB)(JB) LB-050081-10X Per Code: NEC 690.13.B Label Location: (DC) (INV) LB-030042-10X Per Code: NEC 690.53 Label Location: (DC) (INV) LB-070004-10X Per Code: 690.41.B Label Location: (DC) (INV) LB-010001-10X Per Code: CEC 690.13.B Label Location: (DC) (CB) LB-050082-10X Per Code: NEC 690.13.B Label Location: (AC) (POI) LB-040007-10X Per Code: NEC 690.54 Label Location: (AC) (POI) LB-070005-10X Per Code: NEC 690.13.B Label Location: (AC)(POI) LB-070039-10X Per Code: NEC 705.12.B.2.3.b Label Location: (POI) LB-040008-10X Per Code: NEC 690.64.B.4 Label Location: (D) (POI) LB-040009-10X Per Code: NEC 705.12.B.3 Label Location: (POI) LB-060046-10X Per Code: CEC 690.13.B Label Location: (POI) LB-070016-10X Label Location: (DC) (INV) (POI): Point of Interconnection (M): Utility Meter (LC): Load Center (INV): Inverter With Integrated DC Disconnect (IC): Interior Run Conduit (DC): DC Disconnect (D): Distribution Panel (CB): Combiner Box (C): Conduit (AC): AC Disconnect Label Set LB-040137-10X Per Code: NEC 408.4 Label Location: (BLC) LB-040144-10X Per Code: NEC 220 Label Location: (BLC) LB-200025-10X Per Code: NEC 312.8.A(3) Label Location: (MP) LB-030142-10X Per Code: NEC 705.12(B)(3) Label Location: (MP) LB-040141-10X Per Code: Label Location: (MP) LB-040139-10X Per Code: Label Location: (MP) LB-040140-10X Per Code: Label Location: (MP) LB-040138-10X Per Code: Label Location: (MP) LB-200011-10X Per Code: NEC 705.12(B)(3) Label Location: (MP) LB_200127_10X Per Code: NEC 705.12.B.2.3.c Label Location: (MP) LB-200110-10X Per Code: Per 706.7(D) label to be marked in field Label Location: (MP) (MP): Main Panel (BLC): Backup Load Center (AC): AC Disconnect Label Set TESLA.COM/ENERGY POWERWALL Tesla Powerwall is a fully-integrated AC battery system for residential or light commercial use. Its rechargeable lithium-ion battery pack provides energy storage for solar self-consumption, time-based control, and backup. Powerwall’s electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market-leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal)120/240 V Feed-In Type Split Phase Grid Frequency 60 Hz Total Energy1 14 kWh Usable Energy1 13.5 kWh Real Power, max continuous2 5 kW (charge and discharge) Real Power, peak (10 s, off-grid/backup)2 7 kW (charge and discharge) Apparent Power, max continuous 5.8 kVA (charge and discharge) Apparent Power, peak (10 s, off-grid/backup)7.2 kVA (charge and discharge) Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Overcurrent Protection Device 30 A Imbalance for Split-Phase Loads 100% Power Factor Output Range +/– 1.0 adjustable Power Factor Range (full-rated power)+/– 0.85 Internal Battery DC Voltage 50 V Round Trip Efficiency1,3 90% Warranty 10 years ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F) Recommended Temperature 0°C to 30°C (32°F to 86°F) Operating Humidity (RH)Up to 100%, condensing Storage Conditions –20°C to 30°C (–4°F to 86°F) Up to 95% RH, non-condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP56 (Wiring Compartment) Wet Location Rating Yes Noise Level @ 1m < 40 dBA at 30°C (86°F) MECHANICAL SPECIFICATIONS Dimensions1 1150 mm x 753 mm x 147 mm (45.3 in x 29.6 in x 5.75 in) Weight1 114 kg (251.3 lbs) Mounting options Floor or wall mount 1 Dimensions and weight differ slightly if manufactured before March 2019. 1 Values provided for 25°C (77°F), 3.3 kW charge/discharge power. 2 In Backup mode, grid charge power is limited to 3.3 kW. 3 AC to battery to AC, at beginning of life. COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, UL 1973, UL 9540, IEEE 1547, UN 38.3 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003 Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) 753 mm (29.6 in) 147 mm (5.75 in) 1150 mm (45.3 in) Contact Tesla for additional information. TESLA.COM/ENERGY TYPICAL SYSTEM LAYOUTS PARTIAL HOME BACKUP WHOLE HOME BACKUP Main panelSub panel Solar Home loads Solar inverter Utility meter GridBackup Gateway Powerwall Backup loads Optional NA - BACKUP - 2019-06-11 Utility meter Grid Backup Gateway including service disconnect Main panel Solar Whole home backup Solar inverter Powerwall Optional TESLA.COM/ENERGY Backup Gateway 2 POWERWALL 660 411 149 The Backup Gateway 2 for Tesla Powerwall provides energy management and monitoring for solar self-consumption, time-based control, and backup. The Backup Gateway 2 controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a main circuit breaker, the Backup Gateway 2 can be installed at the service entrance. When the optional internal panelboard is installed, the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R PERFORMANCE SPECIFICATIONS AC Voltage (Nominal)120/240V Feed-In Type Split Phase Grid Frequency 60 Hz Current Rating 200 A Maximum Input Short Circuit Current 10 kA1 Overcurrent Protection Device 100-200A; Service Entrance Rated1 Overvoltage Category Category IV AC Meter Revenue accurate (+/– 0.2 %) Primary Connectivity Ethernet, Wi-Fi Secondary Connectivity Cellular (3G, LTE/4G)2 User Interface Tesla App Operating Modes Support for solar self-consumption, time-based control, backup, and off-grid Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC-coupled Powerwalls Optional Internal Panelboard 200A 6-space / 12 circuit Eaton BR Circuit Breakers Warranty 10 years COMPLIANCE INFORMATION Certifications UL 67, UL 869A, UL 916, UL 1741 PCS CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, ICES 003 NA 2020-05-23 1 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 2 The customer is expected to provide internet connectivity for Backup Gateway 2; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. MECHANICAL SPECIFICATIONS Dimensions 660 mm x 411 mm x 149 mm (26 in x 16 in x 6 in) Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi-flush mount YIELD SECURITY ANTI PID TECHNOLOGY (APT) HOT-SPOT PROTECT (HSP) TRACEABLE QUALITY (TRA.QTM) ANTI LID TECHNOLOGY (ALT) Product and Performance Warranty Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.5 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID and Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. ZEP COMPATIBLETM FRAME DESIGN High-tech black Zep CompatibleTM frame, for improved aesthetics, easy installation and increased safety. A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h) 2 See data sheet on rear for further information THE IDEAL SOLUTION FOR: Rooftop arrays on commercial and industrial buildings Q.PEAK DUO BLK-G6+ / SC 330-345 ENDURING HIGH PERFORMANCE Į [% / K] + 0.04 ȕ [% / K] − 0.27 Ȗ [% / K] − 0.36 NMOT [°F] 109 ± 5.4 (43 ± 3 °C) 330 335 340 345 [W] 330 335 340 345 [A] 10.41 10.47 10.52 10.58 [V] 40.15 40.41 40.66 40.92 [A] 9.91 9.97 10.02 10.07 [V] 33.29 33.62 33.94 34.25 [%] ≥ 18.4 ≥ 18.7 ≥ 19.0 ≥ 19.3 [W] 247.0 250.7 254.5 258.2 [A] 8.39 8.43 8.48 8.52 [V] 37.86 38.10 38.34 38.59 [A] 7.80 7.84 7.89 7.93 [V] 31.66 31.97 32.27 32.57 [V] 1000 (IEC) / 1000 (UL)II [A DC] 20 C (IEC) / TYPE 2 (UL) [lbs / ft2] 50 (2400 Pa) / 50 (2400 Pa) − 40 °F up to + 185 °F (− 40 °C up to + 85 °C)[lbs / ft2] 75 (3600 Pa) / 75 (3600 Pa) 3 See Installation Manual Certified UL 1703 (254141) Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us MECHANICAL SPECIFICATION Format 68.5 × 40.6 × 1.57 in (including frame) (1740 × 1030 × 40 mm) Weight 47.4 lbs (21.5 kg) Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 × 20 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 × 1.26-2.36 × 0.59-0.71 in (53-101 × 32-60 × 15-18 mm), Protection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 43.3 in (1100 mm), (−) ≥ 43.3 in (1100 mm) Connector Stäubli MC4; IP68 Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product.Specifications subject to technical changes © Q CELLS Q.PEAK DUO BLK-G6+/SC_330-345_2019-11_Rev01_NAELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)MinimumPower at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 Ș MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 MinimumPower at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1 Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power during first year. Thereafter max. 0.54 % degradation per year. At least 93.1 % of nominal power up to 10 years. At least 85 % of nominal power up to 25 years. All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organization of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m²) TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Normal Module Operating Temperature PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS Protection Class Maximum Series Fuse Rating Fire Rating based on ANSI / UL 1703 Max. Design Load, Push / Pull (UL)3 Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull (UL)3 QUALIFICATIONS AND CERTIFICATES UL 1703, CE-compliant, IEC 61215:2016, IEC 61730:2016, Application Class II, U.S. Patent No. 9,893,215 (solar cells) 200 400 600 800 1000 110 100 90 80RELATIVE EFFICIENCY [%]IRRADIANCE [W/m²]RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]100 95 90 85 80 75 1552520010 YEARS 98 Q CELLS Industry standard for tiered warranties* Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) 37.4" (950 mm) 68.5" (1740 mm) 4 × Fastening points (DETAIL A) Frame 6.06" (154 mm) 40.55" (1030 mm) 38.6" (981 mm) 1.57" (40 mm) 8 × Drainage opening 0.14" × 3.1" (3.6 mm × 8 mm) 6 × Grounding points ø 0.16" (4 mm) Label DETAIL A 0,472" (12 mm) 0.354" (9 mm)1.063" (27 mm) 15.6“ (395 mm) 7.09" (180 mm) 4 × Drainage opening ≥ 43.3" (11 00 m m) ≥ 43. 3" (11 00 m m) DC- DC+ 1 GD · · · · · DC1 · · · · · DC1 DC- DC+ 1 GD TESLA.COM/ENERGY SOLAR SHUTDOWN DEVICESOLAR INVERTER 411 mm 660 mm 158 mm The Tesla Solar Shutdown Device is part of the PV system rapid shutdown (RSD) function in accordance with Article 690 of the applicable NEC. When paired with the Tesla Solar Inverter, the PVRSS is initiated by any loss of AC power. 650 mm 150 mm 125 mm 250 mm M4 Screw M8 Bolt Nail / Wood Screw 22 mm Tesla Solar Inverter provides DC to AC conversion and integrates with the Tesla ecosystem, including Solar Panels, Solar Roof, Powerwall, and vehicle charging, to provide a seamless sustainable energy experience. KEY FEATURES • Integrated rapid shutdown, arc fault, and ground fault protection • No neutral wire simplifies installation • 2x the standard number of MPPTs for high production on complex roofs NA 2021-4-21 ENVIRONMENTAL SPECIFICATIONS Ambient Temperature -40°C to 50°C (-40°F to 122°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) Enclosure Rating NEMA 4 / IP65 ELECTRICAL SPECIFICATIONS Nominal Input DC Current Rating (IMP)12 A Maximum Input Short Circuit Current (ISC)15 A Maximum System Voltage 600 V DC COMPLIANCE INFORMATION Certifications UL 1741 PVRSS PVRSA (Photovoltaic Rapid Shutdown Array) MECHANICAL SPECIFICATIONS Electrical Connections MC4 Connector Housing Plastic Dimensions 125 mm x 150 mm x 22 mm (5 in x 6 in x 1 in) Weight 350 g (0.77 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw RSD MODULE PERFORMANCE Maximum Number of Devices per String 5 Control Power Line Excitation Passive State Normally open Maximum Power Consumption 7 W Warranty 25 years PVRSS RSD Initiation Method Loss of AC power Compatible Equipment Tesla Solar Inverter SOLAR SHUTDOWN DEVICE REQUIREMENTS PER MODULE The following modules have been certified as part of a PV Rapid Shutdown Array (PVRSA) when installed together with the Tesla Solar Inverter and Tesla Solar Shutdown Devices. See the Tesla Solar Inverter Installation Manual for guidance on installing Tesla Solar Inverter and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G6+1 Solar Shutdown Device per 3 modules ENVIRONMENTAL SPECIFICATIONS Operating Temperature5 –30°C to 45°C (–22°F to 113°F) Operating Humidity (RH)Up to 100%, condensing Storage Temperature –30°C to 70°C (–22°F to 158°F) Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating Type 3R Ingress Rating IP55 (Wiring compartment) Pollution Rating PD2 for power electronics and terminal wiring compartment, PD3 for all other components Operating Noise @ 1 m < 40 db(A) nominal, < 50 db(A) maximum ELECTRICAL SPECIFICATIONS MODEL NUMBER 1534000-xx-y 1538000-xx-y OUTPUT (AC)3.8 kW 7.6 kW Nominal Power 3,800 W 7,600 W Maximum Apparent Power 3,328 VA at 208 V 3,840 VA at 240 V 6,656 VA at 208 V 7,680 VA at 240 V Maximum Continuous Current 16 A 32 A Breaker (Overcurrent Protection)20 A 40 A Nominal Power Factor 1 - 0.85 (leading / lagging) THD (at Nominal Power)<5% INPUT (DC) MPPT 2 4 Input Connectors per MPPT 1-2 1-2-1-2 Maximum Input Voltage 600 VDC DC Input Voltage Range 60 - 550 VDC DC MPPT Voltage Range1 60 - 480 VDC Maximum Current per MPPT (Imp)13 A Maximum Short Circuit Current per MPPT (Isc)15 A COMPLIANCE INFORMATION Grid Certifications UL 1741, UL 1741 SA, IEEE 1547, IEEE 1547.1 Safety Certifications UL 1699B, UL 1741, UL 1998 (US) Emissions EN 61000-6-3 (Residential), FCC 47CFR15.109 (a) 1 Maximum current. 2 Expected efficiency pending final CEC listing. 3 Cellular connectivity subject to network operator service coverage and signal strength. MECHANICAL SPECIFICATIONS Dimensions 660 mm x 411 mm x 158 mm (26 in x 16 in x 6 in) Weight 52 lb4 Mounting options Wall mount (bracket) PERFORMANCE SPECIFICATIONS Peak Efficiency2 97.5%98.0% CEC Efficiency2 97.5% Allowable DC/AC Ratio 1.4 Customer Interface Tesla Mobile App Internet Connectivity Wi-Fi (2.4 GHz, 802.11 b/g/n), Ethernet, Cellular (LTE/4G)3 AC Remote Metering Support Wi-Fi (2.4 GHz, 802.11 b/g/n), RS-485 Protections Integrated arc fault circuit interrupter (AFCI), Rapid Shutdown Supported Grid Types 60 Hz, 240 V Split Phase 60 Hz, 208 V Wye Required Number of Tesla Solar Shutdown Devices per Solar Module See Solar Shutdown Device Requirements per Module on page 3 Warranty 12.5 years 4 Door and bracket can be removed for a mounting weight of 37 lb. 5 For the 7.6 kW Solar Inverter, performance may be de-rated to 6.2 kW at 240 V or 5.37 kW at 208 V when operating at temperatures greater than 45°C. HDFKSURGXFW7KHHQGXVHUGRFXPHQWDWLRQVKLSSHGZLWK=HS6RODU ¶VSURGXFWVFRQVWLWXWHVWKHVROHVSHFL¿FDWLRQVUHIHUUHGWRLQWKHSURGXFWZDUUDQW\7KHFXVWRPHULVVROHO\ UHVSRQVLEOHIRUYHULI\LQJWKHVXLWDELOLW\RI=HS6RODU¶VSURGXFWVIRUHDFKXVH6SHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH3DWHQWVDQG$SSV]VSDWVFRP IRUFRPSRVLWLRQVKLQJOHURRIV DQ\PDQXIDFWXUHUFHUWL¿HGDV³7\SH´RU³7\SH´ 6SHFL¿FDWLRQV HDFKSURGXFW7KHHQGXVHUGRFXPHQWDWLRQVKLSSHGZLWK=HS6RODU¶VSURGXFWVFRQVWLWXWHVWKHVROHVSHFL¿FDWLRQVUHIHUUHGWRLQWKHSURGXFWZDUUDQW\7KHFXVWRPHULVVROHO\ UHVSRQVLEOHIRUYHULI\LQJWKHVXLWDELOLW\RI=HS6RODU¶VSURGXFWVIRUHDFKXVH6SHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH3DWHQWVDQG$SSV]VSDWVFRP 1H[W/HYHO390RXQWLQJ7HFKQRORJ\ ]HSVRODUFRP 3DUW1R /LVWHGWR8/ &DSWXUHG:DVKHU/DJ 3DUW1R       )ODVKLQJ,QVHUW 3DUW1R /LVWHGWR8/ $UUD\6NLUW 3DUW1RRU /LVWHGWR8/ 3DUW1RRU /LVWHGWR8/ (QG&DS 3DUW1R / RU 5 RU '&:LUH&OLS 3DUW1R /LVWHGWR8/ *URXQG=HS9 3DUW1R /LVWHGWR8/DQG8/ ,QWHUORFN 3DUW1RRU /LVWHGWR8/ /HYHOLQJ)RRW 3DUW1R /LVWHGWR8/