HomeMy WebLinkAboutRevisions x_� M; ' tt BRADEN & BRADEN, A . I . A . P. A . CO �_RA �_OR COPY ' 5-19-21 417 COCONUT AVENUE, STUART, FLORIDA 34996 TELEPHONE: (772) 287-8258 FAX: (772) 287-8283 REMEWED FOR CODE COMPLIANCE St. Lucie County Building Dept. ST. LUCE COUNTY RE: Wynne Developpment WHOCC ,1Z61-2f Permit #: 2011-05N To whom it may concern: This detail shall apply to the soffit installation for the aforementioned permit number. If you have any questions please feel free to call me at 7 12-287-8258. Sincerely, Digitally signed by Daniel R.Braden e` Date:2021.05.1914:05:18 -04'00' Daniel R. Braden AIA Braden t Braden AIA PA Aluminum Drip Edge E Fascia 117 2" x 6" Sub—Fascia Install 1" x 4" FT nailer long wall using 3/16" dia. tapcons with Attach soffit to bottom of �� min. I" embedment into wall at 24" o.c. fascia_ using trim nails at 16" 12 max. O.C. max. Staple soffit to Attach Channel to nailer using staples fascia at nail hem and in valleys. at nail hem and in valleys. Attach Channel to wall using 0.091" dia. x 1.5" T=nails at Kagcan LTD 12" Triple 4 FULL—O—VENT 12" o.c. into wall. vingl soffit max. open = 12" with max pressure t 55.L TYPICAL SOFFIT DETAIL NTS