Loading...
HomeMy WebLinkAbout11097 s ird fa�'t� �T g" STATE OF FLORIDA � � ��� DEPARTMENT OF HEALTH c • ' �u.Q' ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL coo u� �4"� . APPLICANT: Gary Williams AGENT: Pace 2000, InC PROPERTY ADDREss: 11097 S Indian River Dr Fort Pierce, FL 34982 APPLICATION #:AP15O$76S PERMIT #:56-SF-2089461 DOCUMENT # : FI 1624578 DATE PAID : 06/08/2020 FEE PAID:545.00 RECEIPT #:56-PID-4444734 LOT: SUBDIVISION: BLOCK: 2 ID#: 3532-503-0020-000-3 CHECKED (X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [O1] TANK SIZE [1] 1090.00 [2] [ ] [27] SURFACE WATER 230 FT ( ] [02] TANK MATERIAL Polypropylene [ ] [28] DITCHES FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS gg FT [ ] [04] MULTI -CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER POlylok PL-68 [ ] [31] IRRIGATION WELLS FT [ ] (06] LEGEND 1, 70-143-11DC4 2. [ ] [32] POTABLE WATER 5$ FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 16 FT [ ] [OB] LEVEL [ ] [34] PROPERTY LINES 21 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 384 [2] SQFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X L l [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 4.00 2. [ ] [38] SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION [ ] [14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 2,00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS ( ] [42] r.r.nRMc [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ J [21] AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [22] FILL AMOUNT [ ] [47] CONTRACTOR Jeff Nelson (JEFFREY K NEL [ ] [23] FILL TEXTURE [ ] [48] OTHER INFILTRATOR Quick4 EQ36 (single c [ ] [29] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED � FILLED Comments: Comments are on page 2. / �v vy Q� St. Lucie CHD DATE : 05/05/2021 CONSTRUCTION I APPROVED DISAPPROVED � � ' E v�ir/o�nm�,.eQn�tal Spec'alist I onta a (Flo 'da Department of He FINAL SYSTEM [ APPROVED / DISAPPROVED `>L�v"�' � St. Lucie CHD DATE: O5/O5/2021 Environmental Spec alist II 'tole Montan (F ride Department of He (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1508768 EID2089461 �,�� �,}� STATE OF FLORIDA - .f DEPARTMENT OF HEALTH ��`�s` ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM pry CONSTRUCTION INSPECTION AND FINAL APPROVAL �i wE s Violation Number Comment Comments APPLICATION #:AP15p8768 PERMIT #:56-SF-2089461 DOCUMENT #:F116p24578 DATE PAID:O6�O8�2020 FEE PAID:545.00 RECEIPT #:56-PID-4444734 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd. New ST, filter, and 4x8 long TRENCH DF installed. No violations, system ok to cover. Contractor notified by phone. Final system approved. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1608768 EID2089461